Reports 1-1 of 1 Clear search Modify search
VIS (General)
satoru.ikeda - 17:45 Monday 15 March 2021 (16261) Print this report
Comment to Common Type-C(MCI,MCE,MCO,IMMT1,IMMT2) model. (16234)

Installed new models to MCI, MCE, MCO, IMMT1 and IMMT2 and rebooted.

Foton:
{MCI,MCE,MCO,IMMT1,IMMT2}_TM_OPLEV_{PIT,YAW} -> MCI_TM_OPLEV_TILT_{PIT,YAW}
{MCI,MCE,MCO,IMMT1,IMMT2}_TM_WD_OSEMAC_BANDLIM_{H1,H2,H3,H4} -> MCI_TM_WD_OPLEVAC_BANDLIM_{TILT_SEG1,TILT_SEG2,TILT_SEG3,TILT_SEG4}

Only MCI has been implemented.
Others are still being worked on.

SDF:
New channel is set to MON.
The following values were transferred from safe.snap of the previous model before the change.
 K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_TM_WD_OPLEV_TILT_{PIT,YAW}_GAIN
 From the previous safe.snap
 The value of K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_TM_WD_OPLEV_{PIT,YAW}_GAIN is set.
 

Non-image files attached to this comment
Search Help
×

Warning

×