Common Type-C(MCI,MCE,MCO,IMMT1,IMMT2) model.


Changed the name of PAYLOD_MASTER/PAYLOADTM to PAYLOADTM_OPLEV.
Copy TYPEC_MASTER/IMC to PAYLOAD_MASTER/PAYLOAD_MASTER_IMC and replaced TM with PAYLOADMASTER_OPLEV.
 As a result, there are differences in the following items.
 In order to input ShutDown to TM, PAY_SHUTDOWN is added, DACKILL_TYPEC, DACKILL is used as it is.
 The following process will be lost.
   TM/OPTICALALIGN
   TM/OSC, TM/OSC_CLOCK, TM/DEMOD_1
   TM/OLSET, TM/OLDCCTRL
   TM/OPLEV_BLRMS_P and Y

The following process has been modified to match with other models.
The output of DITHERINF_P and Y is modified to be input to DITHER2EUL.
TM/LINK_P and Y are now outside of TM.

The current build has been checked and is not installed.
 

Non-image files attached to this report
Comments to this report:
satoru.ikeda - 17:45 Monday 15 March 2021 (16261) Print this report

Installed new models to MCI, MCE, MCO, IMMT1 and IMMT2 and rebooted.

Foton:
{MCI,MCE,MCO,IMMT1,IMMT2}_TM_OPLEV_{PIT,YAW} -> MCI_TM_OPLEV_TILT_{PIT,YAW}
{MCI,MCE,MCO,IMMT1,IMMT2}_TM_WD_OSEMAC_BANDLIM_{H1,H2,H3,H4} -> MCI_TM_WD_OPLEVAC_BANDLIM_{TILT_SEG1,TILT_SEG2,TILT_SEG3,TILT_SEG4}

Only MCI has been implemented.
Others are still being worked on.

SDF:
New channel is set to MON.
The following values were transferred from safe.snap of the previous model before the change.
 K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_TM_WD_OPLEV_TILT_{PIT,YAW}_GAIN
 From the previous safe.snap
 The value of K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_TM_WD_OPLEV_{PIT,YAW}_GAIN is set.
 

Non-image files attached to this comment
satoru.ikeda - 15:45 Tuesday 16 March 2021 (16269) Print this report

DACKILL_TYPEC->PAY_SHUTDOWN_TRIGへ名称変更
 FLAG0とTM_WDBLOCKFLAG_Inのピン配置を接続に合わせて入れ替え
DACKILLー>PAY_DACKILへ名称変更

SDF:
 K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_PAY_DACKKILLをACCEPT&MON
 K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_PAY_SHUTDOWN_RAMPTにType-Aに合わせて5secを設定

Foton:
 K1VISMCE.txt
 MCE_TM_LKIN_P_DEMOD_{I,SIG} -> MCE_LKIN_P_DEMOD_{I,SIG}
 MCE_TM_LKIN_Y_DEMOD_{I,Q,SIG} -> MCE_LKIN_Y_DEMOD_{I,Q,SIG}

 MCE_TM_OPLEV_PIT -> MCE_TM_OPLEV_TILT_PIT
 MCE_TM_OPLEV_{SEG1,SEG2,SEG3,SEG4} -> MCE_TM_OPLEV_TILT_{SEG1,SEG2,SEG3,SEG4}
 MCE_TM_WD_OSEMAC_BANDLIM_{H1,H2,H3,H4} -> MCE_TM_WD_OPLEVAC_BANDLIM_{TILT_SEG1,TILT_SEG2,TILT_SEG3,TILT_SEG4}

K1VISMCO.txt
 MCO_TM_OPLEV_{PIT,YAW} -> MCO_TM_OPLEV_TILT_{PIT,YAW}
 MCO_TM_WD_OSEMAC_BANDLIM_{H1,H2,H3,H4} -> MCO_TM_WD_OPLEVAC_BANDLIM_{TILT_SEG1,TILT_SEG2,TILT_SEG3,TILT_SEG4}

K1VISIMMT1.txt
 IMMT1_TM_OLDCCTRL_{P,Y} -> 削除

K1VISIMMT2.txt
 IMMT2_TM_OLDCCTRL_{P,Y}-> 削除
Changed the name from DACKILL_TYPEC->PAY_SHUTDOWN_TRIG
 Changed the pin assignment of FLAG0 and TM_WDBLOCKFLAG_In to match the connection
Renamed to DACKILL->PAY_DACKIL

SDF:
 K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_PAY_DACKKILL is ACCEPT&MON
 Set K1:VIS-{MCI,MCE,MCO,IMMT1,IMMT2}_PAY_SHUTDOWN_RAMPT to 5sec to match Type-A.

Foton:
 K1VISMCE.txt
 MCE_TM_LKIN_P_DEMOD_{I,SIG} -> MCE_LKIN_P_DEMOD_{I,SIG}
 MCE_TM_LKIN_Y_DEMOD_{I,Q,SIG} -> MCE_LKIN_Y_DEMOD_{I,Q,SIG}

 MCE_TM_OPLEV_PIT -> MCE_TM_OPLEV_TILT_PIT
 MCE_TM_OPLEV_{SEG1,SEG2,SEG3,SEG4} -> MCE_TM_OPLEV_TILT_{SEG1,SEG2,SEG3,SEG4}
 MCE_TM_WD_OSEMAC_BANDLIM_{H1,H2,H3,H4} -> MCE_TM_WD_OPLEVAC_BANDLIM_{TILT_SEG1,TILT_SEG2,TILT_SEG3,TILT_SEG4}

K1VISMCO.txt
 MCO_TM_OPLEV_{PIT,YAW} -> MCO_TM_OPLEV_TILT_{PIT,YAW}
 MCO_TM_WD_OSEMAC_BANDLIM_{H1,H2,H3,H4} -> MCO_TM_WD_OPLEVAC_BANDLIM_{TILT_SEG1,TILT_SEG2,TILT_SEG3,TILT_SEG4}

K1VISIMMT1.txt
 IMMT1_TM_OLDCCTRL_{P,Y} -> delete

K1VISIMMT2.txt
 IMMT2_TM_OLDCCTRL_{P,Y}-> delete