Reports 1-1 of 1 Clear search Modify search
VIS (IX)
satoru.ikeda - 17:55 Tuesday 09 March 2021 (16197) Print this report
Comment to Added MN/PF OpLev to k1visitmxp's Model file. (16185)

I checked the EPICS channel of OpLev.

Select Optic:ITMX-PF/MN, IM/TM in sitemap-VIS-VIS_OVERVIEW
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_{SEG1,SEG2,SEG3,SEG4}_INMON
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_{SEG1,SEG2,SEG3,SEG4}_OUTPUT
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_{PIT,YAW,SUM,CRS}_OUTPUT
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_MTRX_x_x

K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_{SEG1,SEG2,SEG3,SEG4}_INMON
K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_{SEG1,SEG2,SEG3,SEG4}_OUTPUT
K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_{PIT,YAW,SUM,CRS}_OUTPUT
K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_MTRX_x_x

ETMX and ETMY are also supported by the same OpLev.

The ADC of FLDACC and OpLev were duplicated, so the FLDACC side was corrected.
 Changed ADC2_16-18 to ADC0_20,21,22, and used ADC0_3 as ACC_H4_In.
 

Non-image files attached to this comment