Reports 1-1 of 1 Clear search Modify search
VIS (IX)
satoru.ikeda - 17:49 Monday 08 March 2021 (16185) Print this report
Added MN/PF OpLev to k1visitmxp's Model file.

Added MN/PF OpLev to k1visitmxp's Model file.
I haven't confirmed the operation yet.
I will check the operation tomorrow.

I will describe the added channels in detail tomorrow.
K :VIS-ITMX_PF_OPLEV_{TILT,LEN}_{SEG1,SEG2,SEG3,SEG4}
K :VIS-ITMX_MN_OPLEV_{TILT,LEN,ROL,TRA,VER}_{SEG1,SEG2,SEG3,SEG4}
etc.
 

Non-image files attached to this report
Comments to this report:
satoru.ikeda - 17:55 Tuesday 09 March 2021 (16197) Print this report

I checked the EPICS channel of OpLev.

Select Optic:ITMX-PF/MN, IM/TM in sitemap-VIS-VIS_OVERVIEW
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_{SEG1,SEG2,SEG3,SEG4}_INMON
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_{SEG1,SEG2,SEG3,SEG4}_OUTPUT
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_{PIT,YAW,SUM,CRS}_OUTPUT
K1:VIS-ITMX_{PF,MN}_OPLEV_{TILT,LEN}_MTRX_x_x

K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_{SEG1,SEG2,SEG3,SEG4}_INMON
K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_{SEG1,SEG2,SEG3,SEG4}_OUTPUT
K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_{PIT,YAW,SUM,CRS}_OUTPUT
K1:VIS-ITMX_MN_OPLEV_{ROL,TRA,VER}_MTRX_x_x

ETMX and ETMY are also supported by the same OpLev.

The ADC of FLDACC and OpLev were duplicated, so the FLDACC side was corrected.
 Changed ADC2_16-18 to ADC0_20,21,22, and used ADC0_3 as ACC_H4_In.
 

Non-image files attached to this comment
satoru.ikeda - 20:44 Wednesday 10 March 2021 (16216) Print this report

K-Log#16185
I re-built and restarted the Tower and Payload model files for SRM, SR2, SR3, PRM, and PR2, which were touched by the common files in the OpLev addition process.
I changed the LowerLimit of the Saturation block to 10 and updated everything. (Type-A was done yesterday)
 

Non-image files attached to this comment
satoru.ikeda - 17:04 Wednesday 17 March 2021 (16278) Print this report

Added processing around OPLEV for Type-A(ITMX,ITMY,ETMX,ETMY).
 K1:VIS-{ITMX,ITMY,ETMX,ETMY}_MN_OLSENSALIGN_x_x
 K1:VIS-{ITMX,ITMY,ETMX,ETMY}_MN_OPLEV2EUL_x_x
 K1:VIS-{ITMX,ITMY,ETMX,ETMY}_MN_QPD2EUL_x_x
 

Non-image files attached to this comment
satoru.ikeda - 13:28 Friday 30 April 2021 (16638) Print this report

Fixed ADC connection for PF/MN OpLev. (ITMX, ITMY, ETMX, ETMY)

The connection is adapted from the attachment of K-Log#16173.
The original connection was based on this diagram, but it seems to have been changed to the one before the modification due to a mistake.

GitID: eb34ed890e1fb488dde5bb479e1d8a2f7be9b601
GpsTime: 1303791828

Non-image files attached to this comment