Reports 1-1 of 1 Clear search Modify search
VIS (EX)
fabian.arellano - 22:27 Wednesday 03 March 2021 (16139) Print this report
Comment to Remedy of F0 (16084)

With Hirata-san and Washimi-san.

Pictures and notebook notes at ETMX Remedying work.

  • We finished the coarse adjustment of the compression of the blades.
  • Blades 1,3, 4 and 5 require additional fine adjustment as the postion of the bases are still more 0.5 mm from the initial position before removal. See this notebook page for details.
  • In order to begin putting back together the keystone assembly we removed the cable tie attached to the suspension rod head we used to pull it up. According to Type-A team the rod won't unhook from F1.
  • Tomorrow we will move the keystone down to hook the suspension rod nail head into the receptacle and finish the assembly.
Search Help
×