Reports 1-1 of 1 Clear search Modify search
VIS (IY)
satoru.ikeda - 17:51 Friday 26 February 2021 (16106) Print this report
Comment to Monitoring of IP by ITMY venting (16091)

Continuing the IY Venting work from yesterday, I moved the IP stepper motor so that the IP would not exceed ±1000 [um].
At 17:45, the values were as follows

K1:VIS-ITMY_IP_DAMP_L_INMON:-15
K1:VIS-ITMY_IP_DAMP_P_INMON:90
K1:VIS-ITMY_IP_DAMP_Y_INMON:-96
K1:VAC-PRESSURE_Y_IYA: 57000

After that, I handed over to miyo-san.

Images attached to this comment