Reports 1-1 of 1 Clear search Modify search
CRY (General)
tatsuki.washimi - 22:32 Monday 03 August 2020 (14855) Print this report
Violin mode analysis for O3GK data

I'm trying the analysis of the violin mode for O3GK data. [for ER -> klog13660]

This is fitted with Lorentzian function by eye.

FWHMs are about 0.014Hz

Images attached to this report
Comments to this report:
tatsuki.washimi - 13:21 Tuesday 04 August 2020 (14860) Print this report

I evaluated each peaks (not all) by fitting.

f0 [Hz] h [m/rtHz] FWHM [Hz]
173.0228 2.78e-16 0.01281
174.0358 1.14e-16 0.01443
176.5108 3.05e-16 0.01309
177.9286 2.06e-16 0.01451
178.2953 1.98e-16 0.01236
178.3876 2.08e-16 0.01790
178.5392 3.33e-16 0.01137
179.0519 1.08e-16 0.01130
179.2474 4.83e-17 0.01325
179.7613 3.06e-16 0.01648
179.8333 2.27e-16 0.01288
180.2531 2.87e-16 0.01203
180.6247 3.39e-16 0.01104
180.9624 2.32e-16 0.01195
181.6604 2.61e-16 0.01300
182.1391 1.18e-16 0.01498
182.5427 2.92e-16 0.01207
182.9588 6.69e-17 0.01045
183.4258 1.96e-16 0.01282
184.3132 1.15e-16 0.01224
184.3861 1.06e-16 0.01481

Images attached to this comment
tatsuki.washimi - 21:25 Saturday 08 August 2020 (14886) Print this report

Update

No.     f0 [Hz]         peak [m/rtHz]   FWHM [Hz]       Q-value         RMS [m]
0       180.625         3.41e-16        0.011           16703           4.44e-17
1       178.539         3.34e-16        0.011           15888           4.44e-17
2       176.511         3.09e-16        0.013           14015           4.34e-17
3       179.761         3.01e-16        0.017           10393           4.96e-17
4       182.543         2.89e-16        0.012           14734           4.03e-17
5       180.253         2.82e-16        0.013           13988           4.01e-17
6       181.661         2.66e-16        0.012           14719           3.70e-17
7       173.023         2.76e-16        0.013           13168           3.97e-17
8       180.963         2.30e-16        0.012           14941           3.17e-17
9       179.834         2.29e-16        0.012           15535           3.09e-17
10      180.903         2.11e-16        0.019            9315           3.68e-17
11      177.929         2.10e-16        0.014           13120           3.06e-17
12      178.387         2.06e-16        0.019            9464           3.54e-17
13      178.295         1.95e-16        0.012           14266           2.74e-17
14      181.615         2.00e-16        0.017           10800           3.25e-17
15      183.426         1.94e-16        0.013           13771           2.81e-17
16      180.061         1.33e-16        0.020            9034           2.35e-17
17      182.139         1.19e-16        0.014           12806           1.79e-17
18      184.313         1.17e-16        0.012           15704           1.59e-17
19      174.036         1.15e-16        0.014           12446           1.71e-17
20      184.386         1.09e-16        0.013           13663           1.58e-17
21      179.052         1.06e-16        0.012           15001           1.46e-17
22      180.092         8.42e-17        0.017           10596           1.38e-17
23      178.424         7.20e-17        0.010           17733           9.05e-18
24      182.959         6.71e-17        0.010           18140           8.45e-18
25      182.092         5.64e-17        0.013           14270           7.99e-18
26      179.247         4.83e-17        0.012           14775           6.67e-18
total RMS = 7.43e-16 [m]
Images attached to this comment
tatsuki.washimi - 13:20 Sunday 09 August 2020 (14888) Print this report

Sorry, "total RMS = 7.43e-16 [m]"  was wrong. it was a simple sum, not a quadratic sum.

The correct one is 1.58e-16 [m]

tatsuki.washimi - 14:39 Tuesday 01 September 2020 (14951) Print this report

I performed the same analysis for the 2nd violinmode

the total RMS is 2.1e-17 [m]

Images attached to this comment
Search Help
×