Reports 1-1 of 1 Clear search Modify search
VIS (SR2)
fabian.arellano - 11:22 Friday 19 June 2020 (14574) Print this report
Comment to Decay time measurements. (14413)

Accordingly to the commented entry, yesterday I added a notch in the IP-L damping filter at 406 mHz. The notch has a quality factor of 10 and a depth of 40 dB.

  • I repeated the measurement and the decay time reduced 40 seconds! Now the decay time with the control system on is 5 seconds shorter than with the control system off.
  • The new mystery is the mode in IP-L at 671 mHz. The UGF is 85 mHz and, therefore, the control system should not be damping this mode. However, it seems it does: the decay time difference between having the control system on and off is 81 seconds.

I shoud add a notch at 671 mHz to check the behaviour.

Search Help
×