Concerning the IP mode at 406 mHz (measured in IP-L) in which the decay time was longer with the control system on, I checked the value of the unity gain frequency. It's 85 mHz as shown in the figure.
If the anomaly comes from the control system I should try to prove it by putting a notch at 406 mHz in the control filter and then repeating the measurement.