Reports 1-1 of 1 Clear search Modify search
VIS (SRM)
tatsuki.washimi - 18:20 Thursday 28 May 2020 (14436) Print this report
F0 if SRM looks unhealthy

It's about 25000 counts. Is it OK?

Images attached to this report
Comments to this report:
fabian.arellano - 11:09 Friday 29 May 2020 (14440) Print this report

The commented entry reported that the feedback signal in F0 GAS filter was too high, namely, around 25,000 counts.

I fixed it by actuating on the keystone with the fishing rod thus reducing the amount of actuation needed to keep it in place.

According to the VIS wilki fishing rod page, this fishing rod does not suffer of any known problems.