Reports 1-1 of 1 Clear search Modify search
PEM (Center)
tatsuki.washimi - 12:32 Tuesday 03 March 2020 (13293) Print this report
PEM portable channel maintenance

[YokozaWashiMiyo]

Today we changed the portable PEM channels

  • K1:PEM-SENSOR_RACK_OMC1_DSUB0_OUT_DQ : ACC on OMC leg  ->  removed
  • K1:PEM-SENSOR_RACK_OMC1_DSUB1_OUT_DQ : ACC on OMC leg  ->  removed
  • K1:PEM-SENSOR_RACK_OMC1_DSUB2_OUT_DQ : ACC on OMC leg  ->  removed
  • K1:PEM-SENSOR_BOOTH_IMC_BNC1_OUT_DQ : ACC (TEAC710) in REFL table, Y-direction ->  ACC (TEAC710) on the ground, between ISS table and IMMT chamber (photo)
  • K1:PEM-SENSOR_BOOTH_IMC_BNC2_OUT_DQ : ACC (TEAC706) on REFL table periscope  ->  ACC (ICP M610) on the ground of MCF chamber  (photo)
  • K1:PEM-SENSOR_BOOTH_IMC_BNC3_OUT_DQ : MIC (ACO 7147A/4152) in REFL booth [No change]
  • K1:PEM-SENSOR_BOOTH_IMC_BNC4_OUT_DQ : Not used  ->     ACC (ICP M610) on PRM leg  (photo)

 

https://docs.google.com/spreadsheets/d/17zcVqZKSC7GaK5Y1_Y0xoedsXjhBfbqMfxlXC_gJ4dY/edit#gid=0

Images attached to this report
Search Help
×

Warning

×