Reports 1-1 of 1 Clear search Modify search
FCL (Air)
tatsuki.washimi - 10:45 Wednesday 19 February 2020 (13038) Print this report
ITMX GAS drift & temperature

In this week, ITMX GAS filters' drift looks hard. (fig. 1)

IXV temperature is decreasing (fig. 2)

IXC temperature is stable (fig. 3)

Images attached to this report
Comments to this report:
shinji.miyoki - 11:11 Wednesday 19 February 2020 (13039) Print this report

I changed the heat power level of a heater in IXV from level2 -> 3 around 10:00. Washimi-kun will check later it. Actually, IXV temp starts increasing by 0.1 C around 11:00 am. 

tatsuki.washimi - 13:53 Wednesday 19 February 2020 (13048) Print this report

this is IXV heater

Images attached to this comment
tatsuki.washimi - 15:00 Wednesday 19 February 2020 (13050) Print this report

Finaly, the heating power brcame "3"