Reports 1-1 of 1 Clear search Modify search
DetChar (General)
tatsuki.washimi - 9:52 Sunday 29 December 2019 (12341) Print this report
Lock segment dependence of BNS range in ER

During the ER, BNS range was changed for each lock segemnts (e.g. https://gwdet.icrr.u-tokyo.ac.jp/~controls/summary/day/20191223/plots/K1-LOCKED_LSC_13F4B6_TIMESERIES-1261094418-86400.png)

 

I compaire the DARM displacement for each segments, duration > 1 hour.

This is the list of such segments : 

startGPS duration[s] BNSrange[kpc]
1260604820 17569 8.5
1260622963 26998 6.8
1260650400 11489 6.4
1260674950 7101 5.7
1260762561 9237 7.5
1260773947 14300 7.7
1260796580 13043 7.8
1260809950 10552 6.8
1260823910 6598 7.3
1260830835 11625 7.8
1260848300 29884 6.4
1260879482 26693 6.2
1260906922 7297 7.6
1260914544 6622 8.3
1260921482 59417 7.0
1260981230 20481 8.6 (best)
1261002159 5954 7.8
1261008552 3786 7.1
1261012916 57505 6.6
1261074113 3705 7.7
1261079464 10627 7.3
1261096347 18624 6.2
1261119565 5461 7.9
1261125486 28536 6.4
1261172127 8690 5.7 (worst)

 


Here, I compaire the best and worst case.

 

 

the floor level is about factor 1.5

 

significant pleaks/bumps are 24-28Hz, 84Hz, 99-103Hz, 120Hz


the first 8 segments :

 

 

although some peaks & bumps are changing, the floor level looks more essential for the BNS range

Images attached to this report