takahiro.yamamoto - 03:26, Saturday 31 August 2019 (10203)Get code to link to this report
nightly Bruco was started
I automated Bruco every 10 minutes only during nightly silent run.
This process checks K1:MIF-WE_ARE_DOING_NOTHING==ON

DOF was judged from the 1st word in K1:MIF-STATUS.
- MICH, DRMI -> MICH
- DARM, FPMI -> DARM

Include file is used from /users/DET/tools/Bruco/share/nightly_$(DOF).txt and results are saved in /users/DET/Result/Bruco/nightly/YYYYMMDD/
You can see the results by executing "firefox file:///users/DET/Result/Bruco/nightly/YYYYMMDD/" or opening [sitemap -> DetChar -> Bruco -> nightly]
Comments related to this report
tatsuki.washimi - 13:26, Wednesday 04 September 2019 (10320)

I make a symbolic link to this page in public_html.

http://k1sum0/~controls/Bruco/

 

this page is also linked from PEM wiki