Reports 1-1 of 1 Clear search Modify search
VIS (General)
satoru.ikeda - 17:09 Friday 12 March 2021 (16252) Print this report
Common Type-C(OMMT1,OMMT2,OSTM) model.

I created PAYLOAD_OSEM by copying PAYLOAD_MASTER/PAYLOADTM_OPLEV.
Replaced the OPLEV inside with OSEMINF, and modified the WD to use LIB/WD1.
Also fixed all OPLEV names to OSEM.
The DAQ channel has also been modified accordingly.
Next, I copied TYPEC_MASTER/OMC to PAYLOAD_MASTER/PAYLOAD_MASTER_OMC and replaced TM with PAYLOADMASTER_OSEM.
 As a result, there are differences in the following items.
 In order to input ShutDown to TM, PAY_SHUTDOWN is added, DACKILL_TYPEC, DACKILL is used as it is.
 The following process will be lost.
   TM/OPTICALALIGN
   TM/OSC, TM/OSC_CLOCK, TM/DEMOD_1

The following processes have been modified to match with other models.
The output of DITHERINF_P and Y is modified to be input to DITHER2EUL.
TM/LINK_P and Y are now outside of TM.

Non-image files attached to this report
Comments to this report:
satoru.ikeda - 19:39 Monday 15 March 2021 (16262) Print this report

Installed new models to OMMT1, OMMT2 and OSTM and rebooted.

SDF:
New channel set to MON.

Foton:

I haven't been able to respond to anything yet, so I'll check the diffs later.

 

Non-image files attached to this comment
satoru.ikeda - 15:44 Tuesday 16 March 2021 (16268) Print this report

Changed the name from DACKILL_TYPEC->PAY_SHUTDOWN_TRIG
 Changed the pin assignment of FLAG0 and TM_WDBLOCKFLAG_In to match the connection
Renamed to DACKILL->PAY_DACKIL

SDF:
 K1:VIS-{OMMT1,OMMT2,OSTM}_PAY_DACKKILL to ACCEPT&MON
 Set K1:VIS-{OMMT1,OMMT2,OSTM}_PAY_SHUTDOWN_RAMPT to 5sec to match Type-A.
  
Foton:
 K1VISOMMT1.txt
 OMMT1_TM_OPLEV_{SEG1,SEG2,SEG3,SEG4} -> delete

 K1VISOMMT2.txt
 OMMT2_TM_OPLEV_{SEG1,SEG2,SEG3,SEG4} -> delete

 K1VISOSTM.txt
 OSTM_TM_LKIN_P_DEMOD_{I,Q} -> OSTM_LKIN_P_DEMOD_{I,Q}
 OSTM_TM_OPLEV_{SEG1,SEG2,SEG3,SEG4} -> delete

 

Non-image files attached to this comment