Reports 1-1 of 1 Clear search Modify search
VIS (EX)
satoru.ikeda - 19:30 Monday 21 December 2020 (15672) Print this report
Support for common Payload model files: Payload of Type-A (ETMX) is supported to PAYLOAD_MASTER.
Support for ETMX
 Replace MN,IM,TM with MN,IM,TM of PAYLOAD_MASTER
 
Model:
 
Modified to use PAYLOAD_MASTER as well as ETMY.
See ETMY for details.
 
To remove WD and DK, set the following values:
 K1:VIS-ETMX_TM_WD_OPLEVAC_RMS_MAX: 0 -> 10000
 K1:VIS-ETMX_IM_WD_OSEMAC_RMS_MAX: 0 -> 10000
 K1:VIS-ETMX_MN_WD_OSEMAC_RMS_MAX: 0 -> 10000
 
The parameters of DITHER were changed to match the original connection as follows
 K1:VIS-SRM_DITHER{P,Y}2EUL_{1,2}_1: {IM,TM}_DTHER_{PIT,YAW}
 Since the combination was connected
 Change K1:VIS-ETMX_DITHER{P,Y}2EUL_{1,2}_1 to 1.0 as well.
 
SDF:
 CHANS NOT FOUND: SDF RESTORE-LOAD
 CHANS NOT INIT: MON(ACCEPT) - CONFIRM 
 SETTINGS DIFFS: K1:VIS-ETMX_MN_COILOUTF_V3 DIFFERNCE:F1 ACCEPT 
 
Foton:
 Please refer to #15662 as it is almost the same as ETMY. 
 
Increase/decrease of EPICS channel :
 Please refer to #15662 as it is almost the same as ETMY.
 
 
k1visetmymon:
 Modify VISMON_MASTER to create TYPEAMON and link to it.
 
k1visetmymon:
 Model:
  k1visetmymon: Fix to link TYPEAMON to VISMON_MASTER
 Remove the following SHMEM
  K1:VIS-ETMX_PREQUA_EXC
 
 Foton:
  Renamed the original file to _beforePAYLOAD_MASTER and left the body almost as it was.
 
 SDF:
  CHANS NOT FOUND: SDF RESTORE-LOAD
  CHANS NOT INIT: MON(ACCEPT) - CONFIRM 
 
k1modaletmy:
 /opt/rtcds/kamioka/k1/target/fb/master
  I commented out the next two lines and did killk1modaletmx.
  /opt/rtcds/kamioka/k1/chans/daq/K1MODALETMX.ini
  /opt/rtcds/kamioka/k1/chans/daq/tpchn?k1modaletmx.par
Support for ETMX
Replace MN,IM,TM with MN,IM,TM of PAYLOAD_MASTER
 
Model:
 
Modified to use PAYLOAD_MASTER as well as ETMY.
See ETMY for details.#15662
 
  • To remove WD and DK, set the following values:
 K1:VIS-ETMX_TM_WD_OPLEVAC_RMS_MAX: 0 -> 10000
 K1:VIS-ETMX_IM_WD_OSEMAC_RMS_MAX: 0 -> 10000
 K1:VIS-ETMX_MN_WD_OSEMAC_RMS_MAX: 0 -> 10000
  • The parameters of DITHER were changed to match the original connection as follows
 K1:VIS-SRM_DITHER{P,Y}2EUL_{1,2}_1: {IM,TM}_DTHER_{PIT,YAW}
 Since the combination was connected
 Change K1:VIS-ETMX_DITHER{P,Y}2EUL_{1,2}_1 to 1.0 as well.
  • SDF:
 CHANS NOT FOUND: SDF RESTORE-LOAD
 CHANS NOT INIT: MON(ACCEPT) - CONFIRM
SETTINGS DIFFS: K1:VIS-ETMX_MN_COILOUTF_V3 DIFFERNCE:F1 ACCEPT
 
Foton:
 
Please refer to #15662 as it is almost the same as ETMY.
 
Increase/decrease of EPICS channel :
 
Please refer to #15662 as it is almost the same as ETMY.

k1visetmymon:
 
Modify VISMON_MASTER to create TYPEAMON and link to it.
 
k1visetmymon:
  • Model:
k1visetmymon: Fix to link TYPEAMON to VISMON_MASTER
  • Remove the following SHMEM
K1:VIS-ETMX_PREQUA_EXC
  • Foton:
Renamed the original file to _beforePAYLOAD_MASTER and left the body almost as it was.
  • SDF:
CHANS NOT FOUND: SDF RESTORE-LOAD
CHANS NOT INIT: MON(ACCEPT) - CONFIRM
 
k1modaletmy:
 
  • /opt/rtcds/kamioka/k1/target/fb/master
 
I commented out the next two lines and did killk1modaletmx.
/opt/rtcds/kamioka/k1/chans/daq/K1MODALETMX.ini
/opt/rtcds/kamioka/k1/chans/daq/tpchn?k1modaletmx.par
 
Non-image files attached to this report