;; This buffer is for text that is not saved, and for Lisp evaluation. ;; To create a file, visit it with C-x C-f and enter text in its buffer. # 1534 2025-11-04 09:46:40.187500 UTC ( 3103s) ['IMCL'] OBSERVATION_WITHOUT_LINES 1446284818.1875 2025-11-04_09:46:40.282404Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked Nearby earthquake 3HZ10, 10HZ30 had large ground motion, then locked loss IMC or PMC locked loss # 1535 2025-11-04 15:03:04.812500 UTC ( 17387s) ['AS_0CROSS'] OBSERVATION_WITHOUT_LINES 1446303802.8125 2025-11-04_15:03:04.892022Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion OMC DCPD saturation -> PMC/IMC locked loss Quite fast saturation OMC DCPD ~ 1 msec Interesting, but I cannot find any reason # 1536 2025-11-04 16:22:30.312500 UTC ( 1844s) [] OBSERVATION_WITHOUT_LINES 1446308568.3125 2025-11-04_16:22:30.385287Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion OMC DCPD saturation -> PMC/IMC locked loss Quite fast saturation OMC DCPD ~ 1 msec Sometimes, there are spike like signal in PRM TM H1 and H3 (P, Y, ) # 1537 2025-11-04 17:28:16.562500 UTC ( 842s) [] OBSERVATION_WITHOUT_LINES 1446312514.5625 2025-11-04_17:28:16.653802Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion Relatively faster OMC DCPD saturation 2~3 msec OMC DCPD saturation -> PMC/IMC locked loss # 1538 2025-11-04 18:09:59.562500 UTC ( 1078s) [] OBSERVATION_WITHOUT_LINES 1446315017.5625 2025-11-04_18:09:59.651676Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion OMC DCPD saturation -> PMC/IMC locked loss Quite fast saturation OMC DCPD ~ 1 msec # 1539 2025-11-04 20:21:21.437500 UTC ( 3078s) [] OBSERVATION_WITHOUT_LINES 1446322899.4375 2025-11-04_20:21:21.511553Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion1 Something became noisy before 2s of locked loss, OMC DCPD saturation -> PMC/IMC locked loss 10 ms drift to saturation # 1540 2025-11-04 21:43:41.562500 UTC ( 3232s) [] OBSERVATION_WITHOUT_LINES 1446327839.5625 2025-11-04_21:43:41.651006Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion OMC DCPD saturation -> PMC/IMC locked loss Quite fast saturation OMC DCPD ~ 1 msec # 1541 2025-11-04 22:07:41.187500 UTC ( 13s) ['AS_0CROSS'] OBSERVATION_WITHOUT_LINES 1446329279.1875 2025-11-04_22:07:41.282462Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked No significant ground motion OMC DCPD saturation -> PMC/IMC locked loss Quite fast saturation OMC DCPD ~ 1 msec # 1542 2025-11-04 23:34:04.937500 UTC ( 711s) ['1Hz'] OBSERVATION_WITHOUT_LINES 1446334462.9375 2025-11-04_23:34:05.024109Z LSC_LOCK [OBSERVATION_WITHOUT_LINES.run] USERMSG 0: IMC seems to be unlocked Large earthquake OMC DCPD saturation -> PMC/IMC locked loss Oscillation in many suspensions