[Oshino-san, YamaT-san(SDF etc), Ikeda] K-Log#33560の続き https://klog.icrr.u-tokyo.ac.jp/osl/?r=33560 概要 K1TEST0のIOシャーシを新IOシャーシに交換しました。 手順 1. PCとIOシャーシの電源をOFF 2. 古いIOシャーシから新しいIOシャーシへカードを移動 ADCカード2枚は、認識順番が変わらないように新しいIOシャーシへ移動した。 S1402721 S1402739 3. PCから不要なカードを取り除き、Adnacoカードをインストールした K1TEST0に刺さっていたHIBカードとDolphinカードは不要なので取り外した。 そして、それぞれ計算機室のケースに格納しました。 HIB card: S/N QS13491186  端子にサビ状の跡が見える Dolphin: AD014513014 4. IOシャーシとDC電源を接続。電源は24V(limit:9.5A)に設定 5. IOシャーシとPCの電源をON 6. dmesgでADCカードを2枚認識していることを確認、medmでエラーがないことを確認 ラック配置 C3 Rack 10-11: K1TEST0 9: Empty 5-8: New IO Chassis S2416128 https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=16128 1-4: KIKUSUI PAN35-10A DC24V-10A C4 Rack 14-18: Old IO Chassis S1605837 https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5837 --- [Oshino-san, YamaT-san(SDF etc), Ikeda] Continuation from K-Log #33560 https://klog.icrr.u-tokyo.ac.jp/osl/?r=33560 Summary We replaced the IO chassis of K1TEST0 with a new IO chassis. Procedure 1. Turned off the power to both the PC and the IO chassis. 2. Transferred the cards from the old IO chassis to the new IO chassis. The two ADC cards were installed in the new IO chassis in the same order to maintain their recognition sequence: S1402721 S1402739 3. Removed unnecessary cards from the PC and installed the Adnaco card. The HIB card and Dolphin card, which were previously installed in K1TEST0, were no longer needed and were removed. They were stored in the storage case in the computer room. HIB card: S/N QS13491186  Rust-like marks are visible on terminals. Dolphin card: AD014513014 4. Connected the IO chassis to the DC power supply. The power supply was set to 24V (current limit: 9.5A). 5. Powered on both the IO chassis and the PC. 6. Confirmed that both ADC cards were detected using dmesg and verified there were no errors in medm. Rack Layout C3 Rack 10-11: K1TEST0 9: Empty 5-8: New IO Chassis S2416128 https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=16128 1-4: KIKUSUI PAN35-10A DC24V-10A C4 Rack 14-18: Old IO Chassis S1605837 https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=5837