モデルファイルの更新 [K1OMC0] model: k1omc DAQチャンネルの変更 削除: K1:OMC-OMMT2_TRANS_QPDA1_DC_SUM_OUT 32768 変更: K1:OMC-AS_PDA1_DC_OUT 32768 -> 16384 追加: K1:OMC-OMMT2_TRANS_PDA1_DC_OUT 16384 追加: K1:OMC-POS_{SPOL,PPOL}_DC_OUT 16384 OMC_TRIG_SIGの修正 adc_3_18: OMMT2_TRANS_PDA1_DCの入力とFilterBank追加 K1:LSC2_OMC_POS_{SPOL1,PPOL1}の受信とFilterBank追加 TRIG_MTRXを追加 LSC_TRIG: K1:OMC-LSC_TRIG_THRESHOLD_HIは、K1:OMC-LSC_TRIG_THRESHOLD_HI_{TRANS,AS}へ変更 ASPOWとTRANSとのOR判定を追加 [K1LSC0] model: k1lsc2 OMCモデルへの送信を追加 adc_0_{22,23}: K1:LSC2_OMC_POS_{SPOL1,PPOL1} --- Update model files Request from Ushiba-san and Aso-san [K1OMC0] model: k1omc Change of DAQ channel Deletion: K1:OMC-OMMT2_TRANS_QPDA1_DC_SUM_OUT 32768 Change: K1:OMC-AS_PDA1_DC_OUT 32768 -> 16384 Added: K1:OMC-OMMT2_TRANS_PDA1_DC_OUT 16384 Added: K1:OMC-POS_{SPOL,PPOL}_DC_OUT 16384 Correction of OMC_TRIG_SIG adc_3_18: add: OMMT2_TRANS_PDA1_DC input and FilterBank Received K1:LSC2_OMC_POS_{SPOL1,PPOL1} and added FilterBank Added TRIG_MTRX LSC_TRIG:. K1:OMC-LSC_TRIG_THRESHOLD_HI changed to K1:OMC-LSC_TRIG_THRESHOLD_HI_{TRANS,AS} Added OR decision between ASPOW and TRANS [K1LSC0] model: k1lsc2 Added transmission to OMC model adc_0_{22,23}: K1:LSC2_OMC_POS_{SPOL1,PPOL1}