Inserting benchmark module... Done inserting module... Running benchmark, please don't interrupt. Seconds left: 1 Removing benchmark module... ********************************* ***** ***** ***** Benchmark: FAIL ***** ***** ***** ********************************* rts_cpu_isolator: entering ligo_play_dead, cpu handler = 00000000a366090f rts_cpu_isolator: calling LIGO code smpboot: CPU 2 didn't die... Total loops: 2246922 Avg: 13647 ns, min: 5878 ns, max: 38216 ns, max_index: 646925, max_index_percent: 28%, rollover_count: 0, Over 0 ns: 0 Test Total Time (s) 35 Histogram Of All Latencies (ns) <3000 : 0 [3000, 4000) : 0 [4000, 5000) : 0 [5000, 6000) : 21071 [6000, 7000) : 0 [7000, 8000) : 0 [8000, 10000) : 46 [10000, 12000) : 41 [12000, 14000) : 2225531 [14000, 16000) : 0 [16000, 18000) : 0 [18000, 22000) : 1 [22000, 25000) : 6 >25000 : 226 BENCHMARK FAIL rts_cpu_isolator: LIGO code is done, calling regular shutdown code It took 9 ms for the RT code to exit. smpboot: Booting Node 0 Processor 2 APIC 0x4