##ETMY length sweep in PRFPMI ##2023.03.30 l i1 2.5 0.0 0.0 n0 s s_eo0 0.0 n0 n_eo1 mod eom1 16881000.0 0.3 3 pm 0.0 n_eo1 n_eo2 s s_eo1 0.0 n_eo2 n_eo3 mod eom2 45015900.0 0.3 3 pm 0.0 n_eo3 n_eo4 s s_eo2 0.0 n_eo4 n_eo5 bs REFL_dummy_mirror 0.0001 0.9999 0.0 0.0 n_eo5 dump REFL_dummy_space_in REFL_gouy_tuner_in s REFL_dummy_space 0.0 REFL_dummy_space_in REFL_dummy_space_out s REFL_gouy_tuner 0.0 REFL_gouy_tuner_in REFL bs IMMT1 0.9922 0.0078 0.0 3.6 REFL_dummy_space_out node2 dump dump attr IMMT1 Rcx -8.91 s simmt1 3.105 node2 node3 bs IMMT2 0.9922 0.0078 0.0 -3.6 node3 node4 dump dump attr IMMT2 Rcy 14.005 s simmt2 4.8416 node4 PRMDUMMY_in m PRMDUMMY 0.0 1.0 0.0 PRMDUMMY_in PRMDUMMY_1 attr PRMDUMMY Rcx 0.0 attr PRMDUMMY Rcy 0.0 s thick_PRM 0.1 1.45 PRMDUMMY_1 PRMDUMMY_out m PRM 0.8999550000000001 0.1 0.0 PRMDUMMY_out npr1 attr PRM Rcx -458.1285 attr PRM Rcy -458.1285 s sLpr1 14.7615 npr1 npr2 bs PR2 0.9994550000000001 0.0005 0.0 0.686 npr3 npr2 POP_gouy_tuner_in POP2_gouy_tuner_in attr PR2 Rcx -3.0764 attr PR2 Rcy -3.0764 s sLpr2 11.0661 npr3 npr4 bs PR3 0.999905 5e-05 0.0 0.686 dump dump npr4 npr5 attr PR3 Rcx -24.9165 attr PR3 Rcy -24.9165 s sLpr3 15.7638 npr5 npr6 s POP_gouy_tuner 0.0 POP_gouy_tuner_in POP s POP2_gouy_tuner 0.0 POP2_gouy_tuner_in POP2 bs MIBS 0.5 0.5 0.0 45.0 npr6 n2 n3 n4 attr MIBS Rcx 0.0 attr MIBS Rcy 0.0 s lx 26.4018 n3 nitx1 s ly 23.072 n2 nity1 m IXAR 0.0 1.0 0.0 nitx1 nitx2 attr IXAR Rcx 0.0 attr IXAR Rcy 0.0 s thick_IX 0.15 1.754 nitx2 nx1 m IYAR 0.0 1.0 0.0 nity1 nity2 attr IYAR Rcx 0.0 attr IYAR Rcy 0.0 s thick_IY 0.15 1.754 nity2 ny1 m ITMX 0.9955927 0.0044073 0.0 nx1 nx2 attr ITMX Rcx -1900.0 attr ITMX Rcy -1900.0 s sx1 3000.0 nx2 nx3 m ETMX 0.9999815 1.85e-05 0.0 nx3 netx1 attr ETMX Rcx 1900.0 attr ETMX Rcy 1900.0 s thick_EX 0.15 1.754 netx1 netx2 m EXAR 0.0 1.0 0.0 netx2 TMSX_gouy_tuner_in s TMSX_gouy_tuner 0.0 TMSX_gouy_tuner_in TMSX m ITMY 0.9951921 0.0048079 90.0 ny1 ny2 attr ITMY Rcx -1900.0 attr ITMY Rcy -1900.0 s sy1 3000.0 ny2 ny3 m ETMY 0.9999813 1.87e-05 90.0 ny3 nety1 attr ETMY Rcx 1900.0 attr ETMY Rcy 1900.0 s thick_EY 0.15 1.754 nety1 nety2 m EYAR 0.0 1.0 0.0 nety2 TMSY_gouy_tuner_in s TMSY_gouy_tuner 0.0 TMSY_gouy_tuner_in TMSY s sLsr3 15.7386 n4 nsr5 bs SR3 1.0 0.0 0.0 0.686 nsr5 nsr4 dump dump attr SR3 Rcx 24.9165 attr SR3 Rcy 24.9165 s sLsr2 11.1115 nsr4 nsr3 bs SR2 1.0 0.0 0.0 0.686 nsr2 nsr3 POS_gouy_tuner_in dump attr SR2 Rcx -2.9872 attr SR2 Rcy -2.9872 s POS_gouy_tuner 0.0 POS_gouy_tuner_in POS s sLsr1 14.7412 nsr2 nsr1 m SRM 0.0 1.0 0.0 nsr1 SRMDUMMY_1 attr SRM Rcx 458.1285 attr SRM Rcy 458.1285 s thick_SRM 0.1 1.45 SRMDUMMY_1 SRMDUMMY_out m SRMDUMMY 0.0 1.0 0.0 SRMDUMMY_out AS_gouy_tuner_in attr SRMDUMMY Rcx 0.0 attr SRMDUMMY Rcy 0.0 s AS_gouy_tuner 0.0 AS_gouy_tuner_in AS cav XARM ITMX nx2 ETMX nx3 cav YARM ITMY ny2 ETMY ny3 cav PRX PRM npr1 ITMX nx1 cav PRY PRM npr1 ITMY ny1 maxtem 1 yaxis lin abs:deg pd TMSX_dc_power TMSX pd TMSY_dc_power TMSY variable deltax 1 xaxis deltax abs lin -0.01 0.01 1000 put* ETMY phi $x1