:219: RuntimeWarning: scipy._lib.messagestream.MessageStream size changed, may indicate binary incompatibility. Expected 56 from C header, got 64 from PyObject gw_summary 2022-02-20 05:52:16 JST INFO: -- GW interferometer summary information system -- gw_summary 2022-02-20 05:52:16 JST DEBUG: This is process 1260435 gw_summary 2022-02-20 05:52:16 JST DEBUG: You have selected gps mode gw_summary 2022-02-20 05:52:16 JST DEBUG: Start time: 2022-02-17 18:46:40.000 (1329158818.0) gw_summary 2022-02-20 05:52:16 JST DEBUG: End time: 2022-02-17 20:33:20.000 (1329165218.0) gw_summary 2022-02-20 05:52:16 JST DEBUG: Output directory: /users/yuzu/work/0216_hveto/test-summary/1329158818-1 329165218 gw_summary 2022-02-20 05:52:16 JST INFO: Loading configuration gw_summary 2022-02-20 05:52:16 JST DEBUG: Loaded 0 units gw_summary 2022-02-20 05:52:16 JST DEBUG: Loaded 0 channels gw_summary 2022-02-20 05:52:16 JST DEBUG: Loaded 3 states gw_summary 2022-02-20 05:52:16 JST DEBUG: Loaded 0 rcParams gw_summary 2022-02-20 05:52:16 JST INFO: Loaded 2 tabs [2 parents overall] gw_summary 2022-02-20 05:52:21 JST DEBUG: Processing DetChar/GreenX Finding K-K1_M frames for [1329158818, 1329165218)... 3 found. Fetching data (from files) for 1 channels [K1_M]: [1329158760, 1329165240): |██████████████████████████████████████████████████████████| 3/3 (100%) ETA 00:00 post-processing... States finalised [1 total] all: 1 segments | 6362.0 seconds [DEFAULT] Processing 'all' state: Grabbing omicron triggers for K1:TMS-X_GR_PDA1_OUT_DQTraceback (most recent call last): File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/astropy/table/operations.py", line 1396, in _vstack col = col_cls.info.new_like(cols, n_rows, metadata_conflicts, out_name) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/astropy/table/column.py", line 372, in new_like attrs = self.merge_cols_attributes(cols, metadata_conflicts, name, File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/astropy/utils/data_info.py", l ine 716, in merge_cols_attributes out['dtype'] = metadata.common_dtype(cols) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/astropy/utils/metadata.py", li ne 64, in common_dtype raise tme astropy.utils.metadata.MergeConflictError: Arrays have incompatible types ['object', 'object', 'float64', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'objec t', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'o bject', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object' , 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'obj ect', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'float64', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'obje ct', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', ' object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'float6 4', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object'] The above exception was the direct cause of the following exception: Traceback (most recent call last): File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/bin/gw_summary", line 10, in sys.exit(main()) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/__main__.py", line 843, in main tab.process(config=config, nds=args.nds, File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/tabs/etg.py", line 262, in process super(EventTriggerTab, self).process(*args, **kwargs) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/tabs/data.py", line 376 , in process self.process_state(state, config=config, nproc=nproc, File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/tabs/etg.py", line 271, in process_state super(EventTriggerTab, self).process_state(state, *args, **kwargs) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/tabs/data.py", line 551 , in process_state get_triggers(channel, etg, state.active, config=config, File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/triggers.py", line 243, in get_triggers trigs = read_cache(segcache, SegmentList([segment]), etg, File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwsumm/triggers.py", line 438, in read_cache table = EventTable.read(cache, **kwargs) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwpy/table/table.py", line 265 , in read return io_read_multi(vstack, cls, source, *args, **kwargs) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/gwpy/io/mp.py", line 103, in r ead_multi return flatten(out) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/astropy/table/operations.py", line 651, in vstack out = _vstack(tables, join_type, col_name_map, metadata_conflicts) File "/home/controls/bin/miniconda2/envs/o4_dqr_proto_4/lib/python3.8/site-packages/astropy/table/operations.py", line 1400, in _vstack raise TableMergeError("The '{}' columns have incompatible types: {}" astropy.table.np_utils.TableMergeError: The 'peak' columns have incompatible types: ['object', 'object', 'float64', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'objec t', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'o bject', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object' , 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'obj ect', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'float64', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'obje ct', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', ' object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object ', 'float64', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object', 'object']