[ 0.000000] Initializing cgroup subsys cpuset [ 0.000000] Initializing cgroup subsys cpu [ 0.000000] Linux version 3.0.8 (controls@master) (gcc version 4.4.3 (Gentoo 4.4.3-r2 p1.2) ) #1 SMP Mon Jun 17 16:45:04 JST 2013 [ 0.000000] Command line: ip=dhcp root=/dev/nfs nfsroot=10.68.10.100:/diskless/root BOOT_IMAGE=kernel-3.0.8-cs [ 0.000000] BIOS-provided physical RAM map: [ 0.000000] BIOS-e820: 0000000000000000 - 000000000009e800 (usable) [ 0.000000] BIOS-e820: 000000000009e800 - 00000000000a0000 (reserved) [ 0.000000] BIOS-e820: 00000000000e0000 - 0000000000100000 (reserved) [ 0.000000] BIOS-e820: 0000000000100000 - 000000007deb2000 (usable) [ 0.000000] BIOS-e820: 000000007deb2000 - 000000007def1000 (reserved) [ 0.000000] BIOS-e820: 000000007def1000 - 000000007dff8000 (ACPI data) [ 0.000000] BIOS-e820: 000000007dff8000 - 000000007e20d000 (ACPI NVS) [ 0.000000] BIOS-e820: 000000007e20d000 - 000000007f36d000 (reserved) [ 0.000000] BIOS-e820: 000000007f36d000 - 000000007f800000 (ACPI NVS) [ 0.000000] BIOS-e820: 0000000080000000 - 0000000090000000 (reserved) [ 0.000000] BIOS-e820: 00000000fed1c000 - 00000000fed40000 (reserved) [ 0.000000] BIOS-e820: 00000000ff000000 - 0000000100000000 (reserved) [ 0.000000] BIOS-e820: 0000000100000000 - 0000000880000000 (usable) [ 0.000000] NX (Execute Disable) protection: active [ 0.000000] DMI 2.7 present. [ 0.000000] DMI: Supermicro X9SRW-F/X9SRW-F, BIOS 3.00 07/05/2013 [ 0.000000] e820 update range: 0000000000000000 - 0000000000010000 (usable) ==> (reserved) [ 0.000000] e820 remove range: 00000000000a0000 - 0000000000100000 (usable) [ 0.000000] No AGP bridge found [ 0.000000] last_pfn = 0x880000 max_arch_pfn = 0x400000000 [ 0.000000] MTRR default type: uncachable [ 0.000000] MTRR fixed ranges enabled: [ 0.000000] 00000-9FFFF write-back [ 0.000000] A0000-BFFFF uncachable [ 0.000000] C0000-FFFFF write-protect [ 0.000000] MTRR variable ranges enabled: [ 0.000000] 0 base 000000000000 mask 3FF800000000 write-back [ 0.000000] 1 base 000800000000 mask 3FFF80000000 write-back [ 0.000000] 2 base 000080000000 mask 3FFF80000000 uncachable [ 0.000000] 3 disabled [ 0.000000] 4 disabled [ 0.000000] 5 disabled [ 0.000000] 6 disabled [ 0.000000] 7 disabled [ 0.000000] 8 disabled [ 0.000000] 9 disabled [ 0.000000] x86 PAT enabled: cpu 0, old 0x7040600070406, new 0x7010600070106 [ 0.000000] e820 update range: 0000000080000000 - 0000000100000000 (usable) ==> (reserved) [ 0.000000] last_pfn = 0x7deb2 max_arch_pfn = 0x400000000 [ 0.000000] found SMP MP-table at [ffff8800000fda90] fda90 [ 0.000000] initial memory mapped : 0 - 20000000 [ 0.000000] Base memory trampoline at [ffff880000099000] 99000 size 20480 [ 0.000000] Using GB pages for direct mapping [ 0.000000] init_memory_mapping: 0000000000000000-000000007deb2000 [ 0.000000] 0000000000 - 0040000000 page 1G [ 0.000000] 0040000000 - 007de00000 page 2M [ 0.000000] 007de00000 - 007deb2000 page 4k [ 0.000000] kernel direct mapping tables up to 7deb2000 @ 1fffd000-20000000 [ 0.000000] init_memory_mapping: 0000000100000000-0000000880000000 [ 0.000000] 0100000000 - 0880000000 page 1G [ 0.000000] kernel direct mapping tables up to 880000000 @ 7deb1000-7deb2000 [ 0.000000] ACPI: RSDP 00000000000f04a0 00024 (v02 SUPERM) [ 0.000000] ACPI: XSDT 000000007df25080 0007C (v01 SUPERM SMCI--MB 00000001 AMI 00010013) [ 0.000000] ACPI: FACP 000000007df2f8d8 000F4 (v04 SUPERM SMCI--MB 00000001 AMI 00010013) [ 0.000000] ACPI: DSDT 000000007df25188 0A74A (v02 SUPERM SMCI--MB 00000000 INTL 20091112) [ 0.000000] ACPI: FACS 000000007e204080 00040 [ 0.000000] ACPI: APIC 000000007df2f9d0 000E4 (v03 00000001 AMI 00010013) [ 0.000000] ACPI: FPDT 000000007df2fab8 00044 (v01 00000001 AMI 00010013) [ 0.000000] ACPI: PRAD 000000007df2fb00 000BE (v02 PRADID PRADTID 00000001 MSFT 04000000) [ 0.000000] ACPI: SPMI 000000007df2fbc0 00040 (v05 A M I OEMSPMI 00000000 AMI. 00000000) [ 0.000000] ACPI: SSDT 000000007df2fc00 C7AE8 (v02 INTEL CpuPm 00004000 INTL 20091112) [ 0.000000] ACPI: EINJ 000000007dff76e8 00130 (v01 AMI AMI EINJ 00000000 00000000) [ 0.000000] ACPI: ERST 000000007dff7818 00230 (v01 AMIER AMI ERST 00000000 00000000) [ 0.000000] ACPI: HEST 000000007dff7a48 000A8 (v01 AMI AMI HEST 00000000 00000000) [ 0.000000] ACPI: BERT 000000007dff7af0 00030 (v01 AMI AMI BERT 00000000 00000000) [ 0.000000] ACPI: MCFG 000000007dff7b20 0003C (v01 SUPERM SMCI--MB 00000001 MSFT 00000097) [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] No NUMA configuration found [ 0.000000] Faking a node at 0000000000000000-0000000880000000 [ 0.000000] Initmem setup node 0 0000000000000000-0000000880000000 [ 0.000000] NODE_DATA [000000087fffb000 - 000000087fffffff] [ 0.000000] [ffffea0000000000-ffffea001dbfffff] PMD -> [ffff88085f600000-ffff88087b5fffff] on node 0 [ 0.000000] Zone PFN ranges: [ 0.000000] DMA 0x00000010 -> 0x00001000 [ 0.000000] DMA32 0x00001000 -> 0x00100000 [ 0.000000] Normal 0x00100000 -> 0x00880000 [ 0.000000] Movable zone start PFN for each node [ 0.000000] early_node_map[3] active PFN ranges [ 0.000000] 0: 0x00000010 -> 0x0000009e [ 0.000000] 0: 0x00000100 -> 0x0007deb2 [ 0.000000] 0: 0x00100000 -> 0x00880000 [ 0.000000] On node 0 totalpages: 8379968 [ 0.000000] DMA zone: 56 pages used for memmap [ 0.000000] DMA zone: 5 pages reserved [ 0.000000] DMA zone: 3921 pages, LIFO batch:0 [ 0.000000] DMA32 zone: 14280 pages used for memmap [ 0.000000] DMA32 zone: 497386 pages, LIFO batch:31 [ 0.000000] Normal zone: 107520 pages used for memmap [ 0.000000] Normal zone: 7756800 pages, LIFO batch:31 [ 0.000000] ACPI: PM-Timer IO Port: 0x408 [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] ACPI: LAPIC (acpi_id[0x00] lapic_id[0x00] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x01] lapic_id[0x02] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x02] lapic_id[0x04] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x03] lapic_id[0x06] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x04] lapic_id[0x08] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x05] lapic_id[0x10] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x06] lapic_id[0x12] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x07] lapic_id[0x14] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x08] lapic_id[0x16] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x09] lapic_id[0x18] enabled) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x00] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x01] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x02] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x03] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x04] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x05] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x06] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x07] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x08] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x09] high edge lint[0x1]) [ 0.000000] ACPI: IOAPIC (id[0x00] address[0xfec00000] gsi_base[0]) [ 0.000000] IOAPIC[0]: apic_id 0, version 32, address 0xfec00000, GSI 0-23 [ 0.000000] ACPI: IOAPIC (id[0x02] address[0xfec01000] gsi_base[24]) [ 0.000000] IOAPIC[1]: apic_id 2, version 32, address 0xfec01000, GSI 24-47 [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 0 global_irq 2 dfl dfl) [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 9 global_irq 9 high level) [ 0.000000] ACPI: IRQ0 used by override. [ 0.000000] ACPI: IRQ2 used by override. [ 0.000000] ACPI: IRQ9 used by override. [ 0.000000] Using ACPI (MADT) for SMP configuration information [ 0.000000] SMP: Allowing 10 CPUs, 0 hotplug CPUs [ 0.000000] nr_irqs_gsi: 64 [ 0.000000] PM: Registered nosave memory: 000000000009e000 - 000000000009f000 [ 0.000000] PM: Registered nosave memory: 000000000009f000 - 00000000000a0000 [ 0.000000] PM: Registered nosave memory: 00000000000a0000 - 00000000000e0000 [ 0.000000] PM: Registered nosave memory: 00000000000e0000 - 0000000000100000 [ 0.000000] PM: Registered nosave memory: 000000007deb2000 - 000000007def1000 [ 0.000000] PM: Registered nosave memory: 000000007def1000 - 000000007dff8000 [ 0.000000] PM: Registered nosave memory: 000000007dff8000 - 000000007e20d000 [ 0.000000] PM: Registered nosave memory: 000000007e20d000 - 000000007f36d000 [ 0.000000] PM: Registered nosave memory: 000000007f36d000 - 000000007f800000 [ 0.000000] PM: Registered nosave memory: 000000007f800000 - 0000000080000000 [ 0.000000] PM: Registered nosave memory: 0000000080000000 - 0000000090000000 [ 0.000000] PM: Registered nosave memory: 0000000090000000 - 00000000fed1c000 [ 0.000000] PM: Registered nosave memory: 00000000fed1c000 - 00000000fed40000 [ 0.000000] PM: Registered nosave memory: 00000000fed40000 - 00000000ff000000 [ 0.000000] PM: Registered nosave memory: 00000000ff000000 - 0000000100000000 [ 0.000000] Allocating PCI resources starting at 90000000 (gap: 90000000:6ed1c000) [ 0.000000] setup_percpu: NR_CPUS:64 nr_cpumask_bits:64 nr_cpu_ids:10 nr_node_ids:1 [ 0.000000] PERCPU: Embedded 25 pages/cpu @ffff88087f000000 s69824 r8192 d24384 u524288 [ 0.000000] pcpu-alloc: s69824 r8192 d24384 u524288 alloc=1*2097152 [ 0.000000] pcpu-alloc: [0] 00 01 02 03 [0] 04 05 06 07 [ 0.000000] pcpu-alloc: [0] 08 09 -- -- [ 0.000000] Built 1 zonelists in Zone order, mobility grouping on. Total pages: 8258107 [ 0.000000] Policy zone: Normal [ 0.000000] Kernel command line: ip=dhcp root=/dev/nfs nfsroot=10.68.10.100:/diskless/root BOOT_IMAGE=kernel-3.0.8-cs [ 0.000000] PID hash table entries: 4096 (order: 3, 32768 bytes) [ 0.000000] xsave/xrstor: enabled xstate_bv 0x7, cntxt size 0x340 [ 0.000000] Checking aperture... [ 0.000000] No AGP bridge found [ 0.000000] Calgary: detecting Calgary via BIOS EBDA area [ 0.000000] Calgary: Unable to locate Rio Grande table in EBDA - bailing! [ 0.000000] Memory: 32981600k/35651584k available (5398k kernel code, 2131712k absent, 538272k reserved, 5343k data, 628k init) [ 0.000000] SLUB: Genslabs=15, HWalign=64, Order=0-3, MinObjects=0, CPUs=10, Nodes=1 [ 0.000000] Hierarchical RCU implementation. [ 0.000000] NR_IRQS:4352 nr_irqs:1168 16 [ 0.000000] Extended CMOS year: 2000 [ 0.000000] Console: colour VGA+ 80x25 [ 0.000000] console [tty0] enabled [ 0.001000] Fast TSC calibration using PIT [ 0.002000] Detected 2799.715 MHz processor. [ 0.000002] Calibrating delay loop (skipped), value calculated using timer frequency.. 5599.43 BogoMIPS (lpj=2799715) [ 0.000523] pid_max: default: 32768 minimum: 301 [ 0.002960] Dentry cache hash table entries: 4194304 (order: 13, 33554432 bytes) [ 0.010692] Inode-cache hash table entries: 2097152 (order: 12, 16777216 bytes) [ 0.014207] Mount-cache hash table entries: 256 [ 0.014557] Initializing cgroup subsys cpuacct [ 0.014831] Initializing cgroup subsys freezer [ 0.015103] CPU: Physical Processor ID: 0 [ 0.015357] CPU: Processor Core ID: 0 [ 0.015617] ENERGY_PERF_BIAS: Set to 'normal', was 'performance' [ 0.015617] ENERGY_PERF_BIAS: View and update with x86_energy_perf_policy(8) [ 0.016147] mce: CPU supports 27 MCE banks [ 0.016438] CPU0: Thermal monitoring enabled (TM1) [ 0.016722] using mwait in idle threads. [ 0.017046] ACPI: Core revision 20110413 [ 0.037949] Switched APIC routing to physical flat. [ 0.038611] ..TIMER: vector=0x30 apic1=0 pin1=2 apic2=-1 pin2=-1 [ 0.048852] CPU0: Intel(R) Xeon(R) CPU E5-2680 v2 @ 2.80GHz stepping 04 [ 0.150542] Performance Events: PEBS fmt1+, generic architected perfmon, Intel PMU driver. [ 0.151141] ... version: 3 [ 0.151394] ... bit width: 48 [ 0.151649] ... generic registers: 8 [ 0.151902] ... value mask: 0000ffffffffffff [ 0.152162] ... max period: 000000007fffffff [ 0.152421] ... fixed-purpose events: 3 [ 0.152679] ... event mask: 00000007000000ff [ 0.153038] Booting Node 0, Processors #1 [ 0.153136] smpboot cpu 1: start_ip = 99000 [ 0.245561] #2 [ 0.245611] smpboot cpu 2: start_ip = 99000 [ 0.336336] #3 [ 0.336386] smpboot cpu 3: start_ip = 99000 [ 0.427100] #4 [ 0.427150] smpboot cpu 4: start_ip = 99000 [ 0.517961] #5 [ 0.518011] smpboot cpu 5: start_ip = 99000 [ 0.608733] #6 [ 0.608783] smpboot cpu 6: start_ip = 99000 [ 0.699605] #7 [ 0.699655] smpboot cpu 7: start_ip = 99000 [ 0.790372] #8 [ 0.790422] smpboot cpu 8: start_ip = 99000 [ 0.881127] #9 Ok. [ 0.886560] smpboot cpu 9: start_ip = 99000 [ 0.976872] Brought up 10 CPUs [ 0.977129] Total of 10 processors activated (55991.69 BogoMIPS). [ 0.985213] kworker/u:0 used greatest stack depth: 5760 bytes left [ 0.985334] PM: Registering ACPI NVS region at 7dff8000 (2183168 bytes) [ 0.985361] PM: Registering ACPI NVS region at 7f36d000 (4796416 bytes) [ 0.985495] Time: 14:28:45 Date: 01/28/22 [ 0.985520] NET: Registered protocol family 16 [ 0.986613] ACPI FADT declares the system doesn't support PCIe ASPM, so disable it [ 0.987082] ACPI: bus type pci registered [ 0.987391] PCI: MMCONFIG for domain 0000 [bus 00-ff] at [mem 0x80000000-0x8fffffff] (base 0x80000000) [ 0.987861] PCI: MMCONFIG at [mem 0x80000000-0x8fffffff] reserved in E820 [ 1.001692] PCI: Using configuration type 1 for base access [ 1.006353] bio: create slab at 0 [ 1.013397] ACPI: EC: Look up EC in DSDT [ 1.013660] \_SB_:_OSC invalid UUID [ 1.013661] _OSC request data:1 6 [ 1.019947] ACPI: Executed 1 blocks of module-level executable AML code [ 1.266605] ACPI: Interpreter enabled [ 1.266861] ACPI: (supports S0 S4 S5) [ 1.267259] ACPI: Using IOAPIC for interrupt routing [ 1.273157] ACPI: No dock devices found. [ 1.273418] PCI: Using host bridge windows from ACPI; if necessary, use "pci=nocrs" and report a bug [ 1.274041] ACPI: PCI Root Bridge [PCI0] (domain 0000 [bus 00-fe]) [ 1.274453] pci_root PNP0A08:00: host bridge window [io 0x0000-0x03af] [ 1.274719] pci_root PNP0A08:00: host bridge window [io 0x03e0-0x0cf7] [ 1.274981] pci_root PNP0A08:00: host bridge window [io 0x03b0-0x03df] [ 1.275247] pci_root PNP0A08:00: host bridge window [io 0x0d00-0xffff] [ 1.275509] pci_root PNP0A08:00: host bridge window [mem 0x000a0000-0x000bffff] [ 1.275980] pci_root PNP0A08:00: host bridge window [mem 0x000c0000-0x000dffff] [ 1.276453] pci_root PNP0A08:00: host bridge window [mem 0xfed08000-0xfed08fff] [ 1.276918] pci_root PNP0A08:00: host bridge window [mem 0xfed0e000-0xfed0ffff] [ 1.277378] pci_root PNP0A08:00: host bridge window [mem 0x80000000-0xfbffffff] [ 1.277847] pci 0000:00:00.0: [8086:0e00] type 0 class 0x000600 [ 1.277888] pci 0000:00:00.0: PME# supported from D0 D3hot D3cold [ 1.277891] pci 0000:00:00.0: PME# disabled [ 1.277911] pci 0000:00:01.0: [8086:0e02] type 1 class 0x000604 [ 1.277956] pci 0000:00:01.0: PME# supported from D0 D3hot D3cold [ 1.277959] pci 0000:00:01.0: PME# disabled [ 1.277983] pci 0000:00:02.0: [8086:0e04] type 1 class 0x000604 [ 1.278028] pci 0000:00:02.0: PME# supported from D0 D3hot D3cold [ 1.278030] pci 0000:00:02.0: PME# disabled [ 1.278051] pci 0000:00:02.2: [8086:0e06] type 1 class 0x000604 [ 1.278096] pci 0000:00:02.2: PME# supported from D0 D3hot D3cold [ 1.278099] pci 0000:00:02.2: PME# disabled [ 1.278121] pci 0000:00:03.0: [8086:0e08] type 1 class 0x000604 [ 1.278166] pci 0000:00:03.0: PME# supported from D0 D3hot D3cold [ 1.278169] pci 0000:00:03.0: PME# disabled [ 1.278190] pci 0000:00:03.2: [8086:0e0a] type 1 class 0x000604 [ 1.278235] pci 0000:00:03.2: PME# supported from D0 D3hot D3cold [ 1.278238] pci 0000:00:03.2: PME# disabled [ 1.278257] pci 0000:00:05.0: [8086:0e28] type 0 class 0x000880 [ 1.278316] pci 0000:00:05.2: [8086:0e2a] type 0 class 0x000880 [ 1.278374] pci 0000:00:05.4: [8086:0e2c] type 0 class 0x000800 [ 1.278383] pci 0000:00:05.4: reg 10: [mem 0xf8105000-0xf8105fff] [ 1.278448] pci 0000:00:11.0: [8086:1d3e] type 1 class 0x000604 [ 1.278511] pci 0000:00:11.0: PME# supported from D0 D3hot D3cold [ 1.278514] pci 0000:00:11.0: PME# disabled [ 1.278542] pci 0000:00:16.0: [8086:1d3a] type 0 class 0x000780 [ 1.278560] pci 0000:00:16.0: reg 10: [mem 0xfed0e000-0xfed0e00f 64bit] [ 1.278606] pci 0000:00:16.0: PME# supported from D0 D3hot D3cold [ 1.278609] pci 0000:00:16.0: PME# disabled [ 1.278624] pci 0000:00:16.1: [8086:1d3b] type 0 class 0x000780 [ 1.278642] pci 0000:00:16.1: reg 10: [mem 0xfed0f000-0xfed0f00f 64bit] [ 1.278689] pci 0000:00:16.1: PME# supported from D0 D3hot D3cold [ 1.278691] pci 0000:00:16.1: PME# disabled [ 1.278718] pci 0000:00:1a.0: [8086:1d2d] type 0 class 0x000c03 [ 1.278737] pci 0000:00:1a.0: reg 10: [mem 0xf8103000-0xf81033ff] [ 1.278803] pci 0000:00:1a.0: PME# supported from D0 D3hot D3cold [ 1.278806] pci 0000:00:1a.0: PME# disabled [ 1.278824] pci 0000:00:1c.0: [8086:1d10] type 1 class 0x000604 [ 1.278881] pci 0000:00:1c.0: PME# supported from D0 D3hot D3cold [ 1.278884] pci 0000:00:1c.0: PME# disabled [ 1.278914] pci 0000:00:1d.0: [8086:1d26] type 0 class 0x000c03 [ 1.278932] pci 0000:00:1d.0: reg 10: [mem 0xf8102000-0xf81023ff] [ 1.278999] pci 0000:00:1d.0: PME# supported from D0 D3hot D3cold [ 1.279002] pci 0000:00:1d.0: PME# disabled [ 1.279018] pci 0000:00:1e.0: [8086:244e] type 1 class 0x000604 [ 1.279068] pci 0000:00:1f.0: [8086:1d41] type 0 class 0x000601 [ 1.279173] pci 0000:00:1f.2: [8086:1d02] type 0 class 0x000106 [ 1.279189] pci 0000:00:1f.2: reg 10: [io 0xf050-0xf057] [ 1.279196] pci 0000:00:1f.2: reg 14: [io 0xf040-0xf043] [ 1.279202] pci 0000:00:1f.2: reg 18: [io 0xf030-0xf037] [ 1.279209] pci 0000:00:1f.2: reg 1c: [io 0xf020-0xf023] [ 1.279216] pci 0000:00:1f.2: reg 20: [io 0xf000-0xf01f] [ 1.279222] pci 0000:00:1f.2: reg 24: [mem 0xf8101000-0xf81017ff] [ 1.279251] pci 0000:00:1f.2: PME# supported from D3hot [ 1.279253] pci 0000:00:1f.2: PME# disabled [ 1.279267] pci 0000:00:1f.3: [8086:1d22] type 0 class 0x000c05 [ 1.279281] pci 0000:00:1f.3: reg 10: [mem 0xf8100000-0xf81000ff 64bit] [ 1.279299] pci 0000:00:1f.3: reg 20: [io 0x1180-0x119f] [ 1.279327] pci 0000:00:1f.6: [8086:1d24] type 0 class 0x001180 [ 1.279346] pci 0000:00:1f.6: reg 10: [mem 0xfed08000-0xfed08fff 64bit] [ 1.279435] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 1.279700] pci 0000:00:01.0: bridge window [io 0xf000-0x0000] (disabled) [ 1.279703] pci 0000:00:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.279708] pci 0000:00:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.279750] pci 0000:02:00.0: [10b5:8632] type 1 class 0x000604 [ 1.279758] pci 0000:02:00.0: reg 10: [mem 0xf9400000-0xf941ffff] [ 1.279789] pci 0000:02:00.0: PME# supported from D0 D3hot D3cold [ 1.279792] pci 0000:02:00.0: PME# disabled [ 1.279809] pci 0000:00:02.0: PCI bridge to [bus 02-1d] [ 1.280070] pci 0000:00:02.0: bridge window [io 0xe000-0xefff] [ 1.280073] pci 0000:00:02.0: bridge window [mem 0xf9200000-0xf94fffff] [ 1.280077] pci 0000:00:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.280114] pci 0000:03:01.0: [10b5:8632] type 1 class 0x000604 [ 1.280154] pci 0000:03:01.0: PME# supported from D0 D3hot D3cold [ 1.280156] pci 0000:03:01.0: PME# disabled [ 1.280174] pci 0000:03:02.0: [10b5:8632] type 1 class 0x000604 [ 1.280212] pci 0000:03:02.0: PME# supported from D0 D3hot D3cold [ 1.280214] pci 0000:03:02.0: PME# disabled [ 1.280232] pci 0000:03:03.0: [10b5:8632] type 1 class 0x000604 [ 1.280270] pci 0000:03:03.0: PME# supported from D0 D3hot D3cold [ 1.280272] pci 0000:03:03.0: PME# disabled [ 1.280290] pci 0000:03:04.0: [10b5:8632] type 1 class 0x000604 [ 1.280328] pci 0000:03:04.0: PME# supported from D0 D3hot D3cold [ 1.280331] pci 0000:03:04.0: PME# disabled [ 1.280348] pci 0000:03:05.0: [10b5:8632] type 1 class 0x000604 [ 1.280386] pci 0000:03:05.0: PME# supported from D0 D3hot D3cold [ 1.280389] pci 0000:03:05.0: PME# disabled [ 1.280414] pci 0000:02:00.0: PCI bridge to [bus 03-1d] [ 1.280676] pci 0000:02:00.0: bridge window [io 0xe000-0xefff] [ 1.280678] pci 0000:02:00.0: bridge window [mem 0xf9200000-0xf93fffff] [ 1.280682] pci 0000:02:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.280712] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 1.280972] pci 0000:03:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.280975] pci 0000:03:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.280979] pci 0000:03:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.281009] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 1.281271] pci 0000:03:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.281274] pci 0000:03:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.281278] pci 0000:03:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.281311] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 1.281573] pci 0000:03:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.281576] pci 0000:03:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.281580] pci 0000:03:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.281623] pci 0000:07:00.0: [111d:8032] type 1 class 0x000604 [ 1.281698] pci 0000:07:00.0: PME# supported from D0 D3hot D3cold [ 1.281702] pci 0000:07:00.0: PME# disabled [ 1.281725] pci 0000:03:04.0: PCI bridge to [bus 07-11] [ 1.281985] pci 0000:03:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.281988] pci 0000:03:04.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.281992] pci 0000:03:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.282049] pci 0000:08:02.0: [111d:8032] type 1 class 0x000604 [ 1.282131] pci 0000:08:02.0: PME# supported from D0 D3hot D3cold [ 1.282135] pci 0000:08:02.0: PME# disabled [ 1.282165] pci 0000:08:03.0: [111d:8032] type 1 class 0x000604 [ 1.282246] pci 0000:08:03.0: PME# supported from D0 D3hot D3cold [ 1.282250] pci 0000:08:03.0: PME# disabled [ 1.282279] pci 0000:08:04.0: [111d:8032] type 1 class 0x000604 [ 1.282361] pci 0000:08:04.0: PME# supported from D0 D3hot D3cold [ 1.282365] pci 0000:08:04.0: PME# disabled [ 1.282395] pci 0000:08:06.0: [111d:8032] type 1 class 0x000604 [ 1.282476] pci 0000:08:06.0: PME# supported from D0 D3hot D3cold [ 1.282481] pci 0000:08:06.0: PME# disabled [ 1.282509] pci 0000:08:07.0: [111d:8032] type 1 class 0x000604 [ 1.282590] pci 0000:08:07.0: PME# supported from D0 D3hot D3cold [ 1.282594] pci 0000:08:07.0: PME# disabled [ 1.282623] pci 0000:08:08.0: [111d:8032] type 1 class 0x000604 [ 1.282705] pci 0000:08:08.0: PME# supported from D0 D3hot D3cold [ 1.282709] pci 0000:08:08.0: PME# disabled [ 1.282739] pci 0000:08:0a.0: [111d:8032] type 1 class 0x000604 [ 1.282820] pci 0000:08:0a.0: PME# supported from D0 D3hot D3cold [ 1.282824] pci 0000:08:0a.0: PME# disabled [ 1.282854] pci 0000:08:0b.0: [111d:8032] type 1 class 0x000604 [ 1.282935] pci 0000:08:0b.0: PME# supported from D0 D3hot D3cold [ 1.282940] pci 0000:08:0b.0: PME# disabled [ 1.282980] pci 0000:07:00.0: PCI bridge to [bus 08-11] [ 1.283249] pci 0000:07:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.283253] pci 0000:07:00.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.283261] pci 0000:07:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.283315] pci 0000:08:02.0: PCI bridge to [bus 09-09] [ 1.283583] pci 0000:08:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.283588] pci 0000:08:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.283595] pci 0000:08:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.283675] pci 0000:0a:00.0: [10b5:8111] type 1 class 0x000604 [ 1.283789] pci 0000:0a:00.0: supports D1 [ 1.283791] pci 0000:0a:00.0: PME# supported from D0 D1 D3hot [ 1.283796] pci 0000:0a:00.0: PME# disabled [ 1.283829] pci 0000:08:03.0: PCI bridge to [bus 0a-0b] [ 1.284097] pci 0000:08:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.284101] pci 0000:08:03.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.284109] pci 0000:08:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.284227] pci 0000:0b:04.0: [10b5:9056] type 0 class 0x000680 [ 1.284266] pci 0000:0b:04.0: reg 10: [mem 0xf9301000-0xf93011ff] [ 1.284299] pci 0000:0b:04.0: reg 18: [mem 0xf9300000-0xf93001ff] [ 1.284488] pci 0000:0a:00.0: PCI bridge to [bus 0b-0b] [ 1.284756] pci 0000:0a:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 1.284762] pci 0000:0a:00.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.284767] pci 0000:0a:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.284835] pci 0000:08:04.0: PCI bridge to [bus 0c-0c] [ 1.285102] pci 0000:08:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.285107] pci 0000:08:04.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.285114] pci 0000:08:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.285171] pci 0000:08:06.0: PCI bridge to [bus 0d-0d] [ 1.285438] pci 0000:08:06.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.285442] pci 0000:08:06.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.285450] pci 0000:08:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.285506] pci 0000:08:07.0: PCI bridge to [bus 0e-0e] [ 1.285776] pci 0000:08:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.285780] pci 0000:08:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.285788] pci 0000:08:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.285844] pci 0000:08:08.0: PCI bridge to [bus 0f-0f] [ 1.286110] pci 0000:08:08.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.286114] pci 0000:08:08.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.286122] pci 0000:08:08.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.286180] pci 0000:08:0a.0: PCI bridge to [bus 10-10] [ 1.286442] pci 0000:08:0a.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.286447] pci 0000:08:0a.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.286455] pci 0000:08:0a.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.286511] pci 0000:08:0b.0: PCI bridge to [bus 11-11] [ 1.286779] pci 0000:08:0b.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.286784] pci 0000:08:0b.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.286792] pci 0000:08:0b.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.286898] pci 0000:12:00.0: [111d:8032] type 1 class 0x000604 [ 1.286973] pci 0000:12:00.0: PME# supported from D0 D3hot D3cold [ 1.286978] pci 0000:12:00.0: PME# disabled [ 1.287001] pci 0000:03:05.0: PCI bridge to [bus 12-1d] [ 1.287262] pci 0000:03:05.0: bridge window [io 0xe000-0xefff] [ 1.287264] pci 0000:03:05.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.287268] pci 0000:03:05.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.287326] pci 0000:13:02.0: [111d:8032] type 1 class 0x000604 [ 1.287408] pci 0000:13:02.0: PME# supported from D0 D3hot D3cold [ 1.287412] pci 0000:13:02.0: PME# disabled [ 1.287441] pci 0000:13:03.0: [111d:8032] type 1 class 0x000604 [ 1.287522] pci 0000:13:03.0: PME# supported from D0 D3hot D3cold [ 1.287526] pci 0000:13:03.0: PME# disabled [ 1.287555] pci 0000:13:04.0: [111d:8032] type 1 class 0x000604 [ 1.287637] pci 0000:13:04.0: PME# supported from D0 D3hot D3cold [ 1.287642] pci 0000:13:04.0: PME# disabled [ 1.287672] pci 0000:13:06.0: [111d:8032] type 1 class 0x000604 [ 1.287753] pci 0000:13:06.0: PME# supported from D0 D3hot D3cold [ 1.287757] pci 0000:13:06.0: PME# disabled [ 1.287787] pci 0000:13:07.0: [111d:8032] type 1 class 0x000604 [ 1.287868] pci 0000:13:07.0: PME# supported from D0 D3hot D3cold [ 1.287873] pci 0000:13:07.0: PME# disabled [ 1.287901] pci 0000:13:08.0: [111d:8032] type 1 class 0x000604 [ 1.287983] pci 0000:13:08.0: PME# supported from D0 D3hot D3cold [ 1.287988] pci 0000:13:08.0: PME# disabled [ 1.288018] pci 0000:13:0a.0: [111d:8032] type 1 class 0x000604 [ 1.288099] pci 0000:13:0a.0: PME# supported from D0 D3hot D3cold [ 1.288103] pci 0000:13:0a.0: PME# disabled [ 1.288132] pci 0000:13:0b.0: [111d:8032] type 1 class 0x000604 [ 1.288215] pci 0000:13:0b.0: PME# supported from D0 D3hot D3cold [ 1.288219] pci 0000:13:0b.0: PME# disabled [ 1.288259] pci 0000:12:00.0: PCI bridge to [bus 13-1d] [ 1.288523] pci 0000:12:00.0: bridge window [io 0xe000-0xefff] [ 1.288528] pci 0000:12:00.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.288536] pci 0000:12:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.288614] pci 0000:14:00.0: [104c:8231] type 1 class 0x000604 [ 1.288721] pci 0000:14:00.0: supports D1 D2 [ 1.288754] pci 0000:13:02.0: PCI bridge to [bus 14-15] [ 1.289021] pci 0000:13:02.0: bridge window [io 0xe000-0xefff] [ 1.289026] pci 0000:13:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.289034] pci 0000:13:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.289129] pci 0000:15:00.0: [1221:8632] type 0 class 0x000480 [ 1.289154] pci 0000:15:00.0: reg 10: [io 0xe000-0xe01f] [ 1.289332] pci 0000:14:00.0: PCI bridge to [bus 15-15] [ 1.289598] pci 0000:14:00.0: bridge window [io 0xe000-0xefff] [ 1.289603] pci 0000:14:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.289612] pci 0000:14:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.289678] pci 0000:13:03.0: PCI bridge to [bus 16-16] [ 1.289946] pci 0000:13:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.289951] pci 0000:13:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.289959] pci 0000:13:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.290015] pci 0000:13:04.0: PCI bridge to [bus 17-17] [ 1.290279] pci 0000:13:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.290284] pci 0000:13:04.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.290291] pci 0000:13:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.290348] pci 0000:13:06.0: PCI bridge to [bus 18-18] [ 1.290609] pci 0000:13:06.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.290614] pci 0000:13:06.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.290622] pci 0000:13:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.290701] pci 0000:19:00.0: [10b5:8111] type 1 class 0x000604 [ 1.290816] pci 0000:19:00.0: supports D1 [ 1.290818] pci 0000:19:00.0: PME# supported from D0 D1 D3hot [ 1.290823] pci 0000:19:00.0: PME# disabled [ 1.290856] pci 0000:13:07.0: PCI bridge to [bus 19-1a] [ 1.291122] pci 0000:13:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.291128] pci 0000:13:07.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.291136] pci 0000:13:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.291250] pci 0000:1a:04.0: [10b5:9056] type 0 class 0x000680 [ 1.291290] pci 0000:1a:04.0: reg 10: [mem 0xf9201000-0xf92011ff] [ 1.291323] pci 0000:1a:04.0: reg 18: [mem 0xf9200000-0xf92001ff] [ 1.291512] pci 0000:19:00.0: PCI bridge to [bus 1a-1a] [ 1.291771] pci 0000:19:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 1.291777] pci 0000:19:00.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.291783] pci 0000:19:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.291850] pci 0000:13:08.0: PCI bridge to [bus 1b-1b] [ 1.292111] pci 0000:13:08.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.292116] pci 0000:13:08.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.292124] pci 0000:13:08.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.292181] pci 0000:13:0a.0: PCI bridge to [bus 1c-1c] [ 1.292442] pci 0000:13:0a.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.292447] pci 0000:13:0a.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.292454] pci 0000:13:0a.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.292510] pci 0000:13:0b.0: PCI bridge to [bus 1d-1d] [ 1.292775] pci 0000:13:0b.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.292780] pci 0000:13:0b.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.292788] pci 0000:13:0b.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.292918] pci 0000:1e:00.0: [1ad7:8000] type 0 class 0x001110 [ 1.292931] pci 0000:1e:00.0: reg 10: [mem 0xf9600000-0xf96001ff] [ 1.293026] pci 0000:00:02.2: PCI bridge to [bus 1e-1e] [ 1.293291] pci 0000:00:02.2: bridge window [io 0xf000-0x0000] (disabled) [ 1.293293] pci 0000:00:02.2: bridge window [mem 0xf9600000-0xf96fffff] [ 1.293298] pci 0000:00:02.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.293333] pci 0000:00:03.0: PCI bridge to [bus 1f-1f] [ 1.293596] pci 0000:00:03.0: bridge window [io 0xf000-0x0000] (disabled) [ 1.293599] pci 0000:00:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.293603] pci 0000:00:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.293647] pci 0000:20:00.0: [9902:0101] type 0 class 0x000680 [ 1.293656] pci 0000:20:00.0: reg 10: [mem 0xf8000000-0xf803ffff] [ 1.293668] pci 0000:20:00.0: reg 18: [mem 0xf4000000-0xf7ffffff] [ 1.293674] pci 0000:20:00.0: reg 1c: [mem 0xf0000000-0xf3ffffff] [ 1.293681] pci 0000:20:00.0: reg 20: [mem 0xec000000-0xefffffff] [ 1.293687] pci 0000:20:00.0: reg 24: [mem 0xe8000000-0xebffffff] [ 1.293712] pci 0000:20:00.0: PME# supported from D0 D3hot [ 1.293714] pci 0000:20:00.0: PME# disabled [ 1.293732] pci 0000:20:00.1: [9902:0102] type 1 class 0x000604 [ 1.293773] pci 0000:20:00.1: PME# supported from D0 D3hot D3cold [ 1.293776] pci 0000:20:00.1: PME# disabled [ 1.293794] pci 0000:00:03.2: PCI bridge to [bus 20-29] [ 1.294057] pci 0000:00:03.2: bridge window [io 0xf000-0x0000] (disabled) [ 1.294060] pci 0000:00:03.2: bridge window [mem 0xe8000000-0xf80fffff] [ 1.294064] pci 0000:00:03.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.294105] pci 0000:21:00.0: [9902:0102] type 1 class 0x000604 [ 1.294154] pci 0000:21:00.0: PME# supported from D0 D3hot D3cold [ 1.294156] pci 0000:21:00.0: PME# disabled [ 1.294177] pci 0000:21:01.0: [9902:0102] type 1 class 0x000604 [ 1.294225] pci 0000:21:01.0: PME# supported from D0 D3hot D3cold [ 1.294228] pci 0000:21:01.0: PME# disabled [ 1.294248] pci 0000:21:02.0: [9902:0102] type 1 class 0x000604 [ 1.294296] pci 0000:21:02.0: PME# supported from D0 D3hot D3cold [ 1.294298] pci 0000:21:02.0: PME# disabled [ 1.294319] pci 0000:21:03.0: [9902:0102] type 1 class 0x000604 [ 1.294367] pci 0000:21:03.0: PME# supported from D0 D3hot D3cold [ 1.294369] pci 0000:21:03.0: PME# disabled [ 1.294389] pci 0000:21:04.0: [9902:0102] type 1 class 0x000604 [ 1.294437] pci 0000:21:04.0: PME# supported from D0 D3hot D3cold [ 1.294440] pci 0000:21:04.0: PME# disabled [ 1.294461] pci 0000:21:05.0: [9902:0102] type 1 class 0x000604 [ 1.294509] pci 0000:21:05.0: PME# supported from D0 D3hot D3cold [ 1.294511] pci 0000:21:05.0: PME# disabled [ 1.294532] pci 0000:21:06.0: [9902:0102] type 1 class 0x000604 [ 1.294579] pci 0000:21:06.0: PME# supported from D0 D3hot D3cold [ 1.294582] pci 0000:21:06.0: PME# disabled [ 1.294602] pci 0000:21:07.0: [9902:0102] type 1 class 0x000604 [ 1.294650] pci 0000:21:07.0: PME# supported from D0 D3hot D3cold [ 1.294653] pci 0000:21:07.0: PME# disabled [ 1.294680] pci 0000:20:00.1: PCI bridge to [bus 21-29] [ 1.294943] pci 0000:20:00.1: bridge window [io 0xfff000-0x0000] (disabled) [ 1.294946] pci 0000:20:00.1: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.294950] pci 0000:20:00.1: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.294988] pci 0000:21:00.0: PCI bridge to [bus 22-22] [ 1.295255] pci 0000:21:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.295258] pci 0000:21:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.295262] pci 0000:21:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.295301] pci 0000:21:01.0: PCI bridge to [bus 23-23] [ 1.295564] pci 0000:21:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.295567] pci 0000:21:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.295572] pci 0000:21:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.295611] pci 0000:21:02.0: PCI bridge to [bus 24-24] [ 1.295876] pci 0000:21:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.295879] pci 0000:21:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.295883] pci 0000:21:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.295922] pci 0000:21:03.0: PCI bridge to [bus 25-25] [ 1.296188] pci 0000:21:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.296191] pci 0000:21:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.296196] pci 0000:21:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.296235] pci 0000:21:04.0: PCI bridge to [bus 26-26] [ 1.296499] pci 0000:21:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.296502] pci 0000:21:04.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.296507] pci 0000:21:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.296545] pci 0000:21:05.0: PCI bridge to [bus 27-27] [ 1.296809] pci 0000:21:05.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.296812] pci 0000:21:05.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.296817] pci 0000:21:05.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.296855] pci 0000:21:06.0: PCI bridge to [bus 28-28] [ 1.297121] pci 0000:21:06.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.297125] pci 0000:21:06.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.297129] pci 0000:21:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.297168] pci 0000:21:07.0: PCI bridge to [bus 29-29] [ 1.297431] pci 0000:21:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 1.297434] pci 0000:21:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.297439] pci 0000:21:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.297516] pci 0000:00:11.0: PCI bridge to [bus 2a-2a] [ 1.297780] pci 0000:00:11.0: bridge window [io 0xf000-0x0000] (disabled) [ 1.297784] pci 0000:00:11.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 1.297790] pci 0000:00:11.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.297854] pci 0000:2b:00.0: [8086:1521] type 0 class 0x000200 [ 1.297871] pci 0000:2b:00.0: reg 10: [mem 0xf9520000-0xf953ffff] [ 1.297895] pci 0000:2b:00.0: reg 18: [io 0xd020-0xd03f] [ 1.297908] pci 0000:2b:00.0: reg 1c: [mem 0xf95c4000-0xf95c7fff] [ 1.297983] pci 0000:2b:00.0: PME# supported from D0 D3hot D3cold [ 1.297987] pci 0000:2b:00.0: PME# disabled [ 1.298039] pci 0000:2b:00.0: reg 184: [mem 0xf95a0000-0xf95a3fff] [ 1.298072] pci 0000:2b:00.0: reg 190: [mem 0xf9580000-0xf9583fff] [ 1.298120] pci 0000:2b:00.1: [8086:1521] type 0 class 0x000200 [ 1.298137] pci 0000:2b:00.1: reg 10: [mem 0xf9500000-0xf951ffff] [ 1.298161] pci 0000:2b:00.1: reg 18: [io 0xd000-0xd01f] [ 1.298174] pci 0000:2b:00.1: reg 1c: [mem 0xf95c0000-0xf95c3fff] [ 1.298249] pci 0000:2b:00.1: PME# supported from D0 D3hot D3cold [ 1.298254] pci 0000:2b:00.1: PME# disabled [ 1.298299] pci 0000:2b:00.1: reg 184: [mem 0xf9560000-0xf9563fff] [ 1.298331] pci 0000:2b:00.1: reg 190: [mem 0xf9540000-0xf9543fff] [ 1.298377] pci 0000:00:1c.0: PCI bridge to [bus 2b-2c] [ 1.298640] pci 0000:00:1c.0: bridge window [io 0xd000-0xdfff] [ 1.298643] pci 0000:00:1c.0: bridge window [mem 0xf9500000-0xf95fffff] [ 1.298648] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 1.298679] pci 0000:2d:04.0: [102b:0532] type 0 class 0x000300 [ 1.298694] pci 0000:2d:04.0: reg 10: [mem 0xfa000000-0xfaffffff pref] [ 1.298703] pci 0000:2d:04.0: reg 14: [mem 0xf9000000-0xf9003fff] [ 1.298711] pci 0000:2d:04.0: reg 18: [mem 0xf8800000-0xf8ffffff] [ 1.298790] pci 0000:00:1e.0: PCI bridge to [bus 2d-2d] (subtractive decode) [ 1.299055] pci 0000:00:1e.0: bridge window [io 0xf000-0x0000] (disabled) [ 1.299058] pci 0000:00:1e.0: bridge window [mem 0xf8800000-0xf90fffff] [ 1.299063] pci 0000:00:1e.0: bridge window [mem 0xfa000000-0xfaffffff 64bit pref] [ 1.299064] pci 0000:00:1e.0: bridge window [io 0x0000-0x03af] (subtractive decode) [ 1.299066] pci 0000:00:1e.0: bridge window [io 0x03e0-0x0cf7] (subtractive decode) [ 1.299067] pci 0000:00:1e.0: bridge window [io 0x03b0-0x03df] (subtractive decode) [ 1.299069] pci 0000:00:1e.0: bridge window [io 0x0d00-0xffff] (subtractive decode) [ 1.299070] pci 0000:00:1e.0: bridge window [mem 0x000a0000-0x000bffff] (subtractive decode) [ 1.299072] pci 0000:00:1e.0: bridge window [mem 0x000c0000-0x000dffff] (subtractive decode) [ 1.299074] pci 0000:00:1e.0: bridge window [mem 0xfed08000-0xfed08fff] (subtractive decode) [ 1.299075] pci 0000:00:1e.0: bridge window [mem 0xfed0e000-0xfed0ffff] (subtractive decode) [ 1.299077] pci 0000:00:1e.0: bridge window [mem 0x80000000-0xfbffffff] (subtractive decode) [ 1.299107] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0._PRT] [ 1.299178] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.P0P9._PRT] [ 1.299197] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.PEX0._PRT] [ 1.299221] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.P0PA._PRT] [ 1.299232] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.NPE1._PRT] [ 1.299247] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.NPE3._PRT] [ 1.299264] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.NPE5._PRT] [ 1.299279] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.NPE7._PRT] [ 1.299294] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.NPE9._PRT] [ 1.299362] pci0000:00: Requesting ACPI _OSC control (0x1d) [ 1.299747] pci0000:00: ACPI _OSC control (0x11) granted [ 1.305674] ACPI: PCI Root Bridge [UNC0] (domain 0000 [bus ff]) [ 1.305978] pci 0000:ff:08.0: [8086:0e80] type 0 class 0x000880 [ 1.306007] pci 0000:ff:09.0: [8086:0e90] type 0 class 0x000880 [ 1.306036] pci 0000:ff:0a.0: [8086:0ec0] type 0 class 0x000880 [ 1.306058] pci 0000:ff:0a.1: [8086:0ec1] type 0 class 0x000880 [ 1.306079] pci 0000:ff:0a.2: [8086:0ec2] type 0 class 0x000880 [ 1.306103] pci 0000:ff:0a.3: [8086:0ec3] type 0 class 0x000880 [ 1.306126] pci 0000:ff:0b.0: [8086:0e1e] type 0 class 0x000880 [ 1.306145] pci 0000:ff:0b.3: [8086:0e1f] type 0 class 0x000880 [ 1.306165] pci 0000:ff:0c.0: [8086:0ee0] type 0 class 0x000880 [ 1.306184] pci 0000:ff:0c.1: [8086:0ee2] type 0 class 0x000880 [ 1.306204] pci 0000:ff:0c.2: [8086:0ee4] type 0 class 0x000880 [ 1.306223] pci 0000:ff:0c.3: [8086:0ee6] type 0 class 0x000880 [ 1.306243] pci 0000:ff:0c.4: [8086:0ee8] type 0 class 0x000880 [ 1.306263] pci 0000:ff:0d.0: [8086:0ee1] type 0 class 0x000880 [ 1.306282] pci 0000:ff:0d.1: [8086:0ee3] type 0 class 0x000880 [ 1.306302] pci 0000:ff:0d.2: [8086:0ee5] type 0 class 0x000880 [ 1.306321] pci 0000:ff:0d.3: [8086:0ee7] type 0 class 0x000880 [ 1.306340] pci 0000:ff:0d.4: [8086:0ee9] type 0 class 0x000880 [ 1.306362] pci 0000:ff:0e.0: [8086:0ea0] type 0 class 0x000880 [ 1.306385] pci 0000:ff:0e.1: [8086:0e30] type 0 class 0x001101 [ 1.306412] pci 0000:ff:0f.0: [8086:0ea8] type 0 class 0x000880 [ 1.306441] pci 0000:ff:0f.1: [8086:0e71] type 0 class 0x000880 [ 1.306470] pci 0000:ff:0f.2: [8086:0eaa] type 0 class 0x000880 [ 1.306499] pci 0000:ff:0f.3: [8086:0eab] type 0 class 0x000880 [ 1.306528] pci 0000:ff:0f.4: [8086:0eac] type 0 class 0x000880 [ 1.306556] pci 0000:ff:0f.5: [8086:0ead] type 0 class 0x000880 [ 1.306587] pci 0000:ff:10.0: [8086:0eb0] type 0 class 0x000880 [ 1.306617] pci 0000:ff:10.1: [8086:0eb1] type 0 class 0x000880 [ 1.306646] pci 0000:ff:10.2: [8086:0eb2] type 0 class 0x000880 [ 1.306675] pci 0000:ff:10.3: [8086:0eb3] type 0 class 0x000880 [ 1.306704] pci 0000:ff:10.4: [8086:0eb4] type 0 class 0x000880 [ 1.306734] pci 0000:ff:10.5: [8086:0eb5] type 0 class 0x000880 [ 1.306764] pci 0000:ff:10.6: [8086:0eb6] type 0 class 0x000880 [ 1.306793] pci 0000:ff:10.7: [8086:0eb7] type 0 class 0x000880 [ 1.306823] pci 0000:ff:13.0: [8086:0e1d] type 0 class 0x000880 [ 1.306843] pci 0000:ff:13.1: [8086:0e34] type 0 class 0x001101 [ 1.306863] pci 0000:ff:13.4: [8086:0e81] type 0 class 0x000880 [ 1.306883] pci 0000:ff:13.5: [8086:0e36] type 0 class 0x001101 [ 1.306906] pci 0000:ff:16.0: [8086:0ec8] type 0 class 0x000880 [ 1.306925] pci 0000:ff:16.1: [8086:0ec9] type 0 class 0x000880 [ 1.306945] pci 0000:ff:16.2: [8086:0eca] type 0 class 0x000880 [ 1.306977] pci0000:ff: Requesting ACPI _OSC control (0x1d) [ 1.307245] pci0000:ff: ACPI _OSC control (0x1d) granted [ 1.308606] ACPI: PCI Interrupt Link [LNKA] (IRQs 3 4 5 6 7 10 *11 12 14 15) [ 1.309427] ACPI: PCI Interrupt Link [LNKB] (IRQs 3 4 5 6 7 *10 11 12 14 15) [ 1.310248] ACPI: PCI Interrupt Link [LNKC] (IRQs 3 4 *5 6 10 11 12 14 15) [ 1.311021] ACPI: PCI Interrupt Link [LNKD] (IRQs *3 4 5 6 10 11 12 14 15) [ 1.311794] ACPI: PCI Interrupt Link [LNKE] (IRQs 3 4 5 6 7 10 11 12 14 15) *0 [ 1.312867] ACPI: PCI Interrupt Link [LNKF] (IRQs 3 4 5 6 7 10 11 12 14 15) *0 [ 1.313940] ACPI: PCI Interrupt Link [LNKG] (IRQs 3 4 5 6 7 10 11 12 14 15) *0 [ 1.315007] ACPI: PCI Interrupt Link [LNKH] (IRQs 3 4 5 6 *7 10 11 12 14 15) [ 1.315900] vgaarb: device added: PCI:0000:2d:04.0,decodes=io+mem,owns=io+mem,locks=none [ 1.316384] vgaarb: loaded [ 1.316639] vgaarb: bridge control possible 0000:2d:04.0 [ 1.316985] SCSI subsystem initialized [ 1.317305] libata version 3.00 loaded. [ 1.317409] usbcore: registered new interface driver usbfs [ 1.317689] usbcore: registered new interface driver hub [ 1.317974] usbcore: registered new device driver usb [ 1.318368] Advanced Linux Sound Architecture Driver Version 1.0.24. [ 1.318630] PCI: Using ACPI for IRQ routing [ 1.323876] PCI: pci_cache_line_size set to 64 bytes [ 1.324114] reserve RAM buffer: 000000000009e800 - 000000000009ffff [ 1.324116] reserve RAM buffer: 000000007deb2000 - 000000007fffffff [ 1.324275] cfg80211: Calling CRDA to update world regulatory domain [ 1.324739] pnp: PnP ACPI init [ 1.325001] ACPI: bus type pnp registered [ 1.325344] pnp 00:00: [bus 00-fe] [ 1.325346] pnp 00:00: [io 0x0cf8-0x0cff] [ 1.325347] pnp 00:00: [io 0x0000-0x03af window] [ 1.325348] pnp 00:00: [io 0x03e0-0x0cf7 window] [ 1.325350] pnp 00:00: [io 0x03b0-0x03df window] [ 1.325351] pnp 00:00: [io 0x0d00-0xffff window] [ 1.325352] pnp 00:00: [mem 0x000a0000-0x000bffff window] [ 1.325354] pnp 00:00: [mem 0x000c0000-0x000dffff window] [ 1.325355] pnp 00:00: [mem 0xfed08000-0xfed08fff window] [ 1.325356] pnp 00:00: [mem 0xfed0e000-0xfed0ffff window] [ 1.325358] pnp 00:00: [mem 0x80000000-0xfbffffff window] [ 1.325359] pnp 00:00: [mem 0x00000000 window] [ 1.325401] pnp 00:00: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 1.325407] pnp 00:01: [mem 0xfc000000-0xfcffffff] [ 1.325409] pnp 00:01: [mem 0xfd000000-0xfdffffff] [ 1.325410] pnp 00:01: [mem 0xfe000000-0xfeafffff] [ 1.325413] pnp 00:01: [mem 0xfeb00000-0xfebfffff] [ 1.325466] system 00:01: [mem 0xfc000000-0xfcffffff] has been reserved [ 1.325726] system 00:01: [mem 0xfd000000-0xfdffffff] has been reserved [ 1.325990] system 00:01: [mem 0xfe000000-0xfeafffff] has been reserved [ 1.326255] system 00:01: [mem 0xfeb00000-0xfebfffff] has been reserved [ 1.326515] system 00:01: Plug and Play ACPI device, IDs PNP0c01 (active) [ 1.326533] pnp 00:02: [dma 4] [ 1.326534] pnp 00:02: [io 0x0000-0x000f] [ 1.326536] pnp 00:02: [io 0x0081-0x0083] [ 1.326537] pnp 00:02: [io 0x0087] [ 1.326538] pnp 00:02: [io 0x0089-0x008b] [ 1.326539] pnp 00:02: [io 0x008f] [ 1.326540] pnp 00:02: [io 0x00c0-0x00df] [ 1.326561] pnp 00:02: Plug and Play ACPI device, IDs PNP0200 (active) [ 1.326567] pnp 00:03: [io 0x0070-0x0071] [ 1.326573] pnp 00:03: [irq 8] [ 1.326597] pnp 00:03: Plug and Play ACPI device, IDs PNP0b00 (active) [ 1.326602] pnp 00:04: [io 0x0061] [ 1.326623] pnp 00:04: Plug and Play ACPI device, IDs PNP0800 (active) [ 1.326636] pnp 00:05: [io 0x0010-0x001f] [ 1.326637] pnp 00:05: [io 0x0022-0x003f] [ 1.326638] pnp 00:05: [io 0x0044-0x005f] [ 1.326639] pnp 00:05: [io 0x0062-0x0063] [ 1.326640] pnp 00:05: [io 0x0065-0x006f] [ 1.326641] pnp 00:05: [io 0x0072-0x007f] [ 1.326642] pnp 00:05: [io 0x0080] [ 1.326643] pnp 00:05: [io 0x0084-0x0086] [ 1.326644] pnp 00:05: [io 0x0088] [ 1.326645] pnp 00:05: [io 0x008c-0x008e] [ 1.326647] pnp 00:05: [io 0x0090-0x009f] [ 1.326648] pnp 00:05: [io 0x00a2-0x00bf] [ 1.326649] pnp 00:05: [io 0x00e0-0x00ef] [ 1.326650] pnp 00:05: [io 0x04d0-0x04d1] [ 1.326651] pnp 00:05: [mem 0x00000400-0x000004ff] [ 1.326708] system 00:05: [io 0x04d0-0x04d1] has been reserved [ 1.326971] system 00:05: [mem 0x00000400-0x000004ff] could not be reserved [ 1.327236] system 00:05: Plug and Play ACPI device, IDs PNP0c02 (active) [ 1.327241] pnp 00:06: [io 0x00f0-0x00ff] [ 1.327245] pnp 00:06: [irq 13] [ 1.327267] pnp 00:06: Plug and Play ACPI device, IDs PNP0c04 (active) [ 1.327287] pnp 00:07: [io 0x0000-0xffffffffffffffff disabled] [ 1.327289] pnp 00:07: [io 0x0000-0xffffffffffffffff disabled] [ 1.327343] system 00:07: Plug and Play ACPI device, IDs PNP0c02 (active) [ 1.327399] pnp 00:08: [io 0x0000-0xffffffffffffffff disabled] [ 1.327400] pnp 00:08: [io 0x0b00-0x0b7f] [ 1.327401] pnp 00:08: [io 0x0000-0xffffffffffffffff disabled] [ 1.327403] pnp 00:08: [io 0x0000-0xffffffffffffffff disabled] [ 1.327404] pnp 00:08: [io 0x0000-0xffffffffffffffff disabled] [ 1.327457] system 00:08: [io 0x0b00-0x0b7f] has been reserved [ 1.327716] system 00:08: Plug and Play ACPI device, IDs PNP0c02 (active) [ 1.327876] pnp 00:09: [io 0x0ca2] [ 1.327877] pnp 00:09: [io 0x0ca3] [ 1.327900] pnp 00:09: Plug and Play ACPI device, IDs IPI0001 (active) [ 1.327979] pnp 00:0a: [io 0x0400-0x0453] [ 1.327980] pnp 00:0a: [io 0x0458-0x047f] [ 1.327981] pnp 00:0a: [io 0x1180-0x119f] [ 1.327982] pnp 00:0a: [io 0x0500-0x057f] [ 1.327983] pnp 00:0a: [mem 0xfed1c000-0xfed1ffff] [ 1.327986] pnp 00:0a: [mem 0xfec00000-0xfecfffff] [ 1.327988] pnp 00:0a: [mem 0xff000000-0xffffffff] [ 1.328042] system 00:0a: [io 0x0400-0x0453] has been reserved [ 1.328308] system 00:0a: [io 0x0458-0x047f] has been reserved [ 1.328572] system 00:0a: [io 0x1180-0x119f] has been reserved [ 1.328833] system 00:0a: [io 0x0500-0x057f] has been reserved [ 1.329094] system 00:0a: [mem 0xfed1c000-0xfed1ffff] has been reserved [ 1.329353] system 00:0a: [mem 0xfec00000-0xfecfffff] could not be reserved [ 1.329613] system 00:0a: [mem 0xff000000-0xffffffff] has been reserved [ 1.329874] system 00:0a: Plug and Play ACPI device, IDs PNP0c01 (active) [ 1.329898] pnp 00:0b: [io 0x0454-0x0457] [ 1.329951] system 00:0b: [io 0x0454-0x0457] has been reserved [ 1.330214] system 00:0b: Plug and Play ACPI device, IDs INT3f0d PNP0c02 (active) [ 1.330307] pnp 00:0c: [bus ff] [ 1.330345] pnp 00:0c: Plug and Play ACPI device, IDs PNP0a03 (active) [ 1.330423] pnp 00:0d: [mem 0x00000000-0x0009ffff] [ 1.330487] system 00:0d: [mem 0x00000000-0x0009ffff] could not be reserved [ 1.330747] system 00:0d: Plug and Play ACPI device, IDs PNP0c01 (active) [ 1.330864] pnp: PnP ACPI: found 14 devices [ 1.331127] ACPI: ACPI bus type pnp unregistered [ 1.337485] Switching to clocksource acpi_pm [ 1.337776] PCI: max bus depth: 6 pci_try_num: 7 [ 1.338036] Switched to NOHz mode on CPU #0 [ 1.338106] Switched to NOHz mode on CPU #9 [ 1.338117] Switched to NOHz mode on CPU #3 [ 1.338119] Switched to NOHz mode on CPU #8 [ 1.338137] Switched to NOHz mode on CPU #5 [ 1.338158] Switched to NOHz mode on CPU #7 [ 1.338163] Switched to NOHz mode on CPU #2 [ 1.338173] Switched to NOHz mode on CPU #4 [ 1.338198] Switched to NOHz mode on CPU #6 [ 1.338199] Switched to NOHz mode on CPU #1 [ 1.340726] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 1.340994] pci 0000:00:01.0: bridge window [io disabled] [ 1.341255] pci 0000:00:01.0: bridge window [mem disabled] [ 1.341518] pci 0000:00:01.0: bridge window [mem pref disabled] [ 1.341785] pci 0000:03:05.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.342057] pci 0000:03:01.0: BAR 14: can't assign mem (size 0x200000) [ 1.342321] pci 0000:03:01.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.342586] pci 0000:03:01.0: BAR 13: can't assign io (size 0x1000) [ 1.342851] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 1.343117] pci 0000:03:01.0: bridge window [io disabled] [ 1.343383] pci 0000:03:01.0: bridge window [mem disabled] [ 1.343647] pci 0000:03:01.0: bridge window [mem pref disabled] [ 1.343915] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 1.344175] pci 0000:03:02.0: bridge window [io disabled] [ 1.344437] pci 0000:03:02.0: bridge window [mem disabled] [ 1.344700] pci 0000:03:02.0: bridge window [mem pref disabled] [ 1.344969] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 1.345229] pci 0000:03:03.0: bridge window [io disabled] [ 1.345490] pci 0000:03:03.0: bridge window [mem disabled] [ 1.345751] pci 0000:03:03.0: bridge window [mem pref disabled] [ 1.346022] pci 0000:08:02.0: PCI bridge to [bus 09-09] [ 1.346280] pci 0000:08:02.0: bridge window [io disabled] [ 1.346544] pci 0000:08:02.0: bridge window [mem disabled] [ 1.346808] pci 0000:08:02.0: bridge window [mem pref disabled] [ 1.347082] pci 0000:0a:00.0: PCI bridge to [bus 0b-0b] [ 1.347340] pci 0000:0a:00.0: bridge window [io disabled] [ 1.347606] pci 0000:0a:00.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.347879] pci 0000:0a:00.0: bridge window [mem pref disabled] [ 1.348148] pci 0000:08:03.0: PCI bridge to [bus 0a-0b] [ 1.348403] pci 0000:08:03.0: bridge window [io disabled] [ 1.348664] pci 0000:08:03.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.348930] pci 0000:08:03.0: bridge window [mem pref disabled] [ 1.349193] pci 0000:08:04.0: PCI bridge to [bus 0c-0c] [ 1.349448] pci 0000:08:04.0: bridge window [io disabled] [ 1.349709] pci 0000:08:04.0: bridge window [mem disabled] [ 1.349979] pci 0000:08:04.0: bridge window [mem pref disabled] [ 1.350248] pci 0000:08:06.0: PCI bridge to [bus 0d-0d] [ 1.350510] pci 0000:08:06.0: bridge window [io disabled] [ 1.350776] pci 0000:08:06.0: bridge window [mem disabled] [ 1.351047] pci 0000:08:06.0: bridge window [mem pref disabled] [ 1.351316] pci 0000:08:07.0: PCI bridge to [bus 0e-0e] [ 1.356763] pci 0000:08:07.0: bridge window [io disabled] [ 1.357037] pci 0000:08:07.0: bridge window [mem disabled] [ 1.357301] pci 0000:08:07.0: bridge window [mem pref disabled] [ 1.357568] pci 0000:08:08.0: PCI bridge to [bus 0f-0f] [ 1.357828] pci 0000:08:08.0: bridge window [io disabled] [ 1.358100] pci 0000:08:08.0: bridge window [mem disabled] [ 1.358367] pci 0000:08:08.0: bridge window [mem pref disabled] [ 1.358638] pci 0000:08:0a.0: PCI bridge to [bus 10-10] [ 1.358906] pci 0000:08:0a.0: bridge window [io disabled] [ 1.359175] pci 0000:08:0a.0: bridge window [mem disabled] [ 1.359441] pci 0000:08:0a.0: bridge window [mem pref disabled] [ 1.359710] pci 0000:08:0b.0: PCI bridge to [bus 11-11] [ 1.359976] pci 0000:08:0b.0: bridge window [io disabled] [ 1.360244] pci 0000:08:0b.0: bridge window [mem disabled] [ 1.360508] pci 0000:08:0b.0: bridge window [mem pref disabled] [ 1.360777] pci 0000:07:00.0: PCI bridge to [bus 08-11] [ 1.361044] pci 0000:07:00.0: bridge window [io disabled] [ 1.361313] pci 0000:07:00.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.361579] pci 0000:07:00.0: bridge window [mem pref disabled] [ 1.361853] pci 0000:03:04.0: PCI bridge to [bus 07-11] [ 1.362114] pci 0000:03:04.0: bridge window [io disabled] [ 1.362376] pci 0000:03:04.0: bridge window [mem 0xf9300000-0xf93fffff] [ 1.362635] pci 0000:03:04.0: bridge window [mem pref disabled] [ 1.362901] pci 0000:14:00.0: PCI bridge to [bus 15-15] [ 1.363157] pci 0000:14:00.0: bridge window [io 0xe000-0xefff] [ 1.363419] pci 0000:14:00.0: bridge window [mem disabled] [ 1.363678] pci 0000:14:00.0: bridge window [mem pref disabled] [ 1.363947] pci 0000:13:02.0: PCI bridge to [bus 14-15] [ 1.364210] pci 0000:13:02.0: bridge window [io 0xe000-0xefff] [ 1.364477] pci 0000:13:02.0: bridge window [mem disabled] [ 1.364743] pci 0000:13:02.0: bridge window [mem pref disabled] [ 1.365017] pci 0000:13:03.0: PCI bridge to [bus 16-16] [ 1.365278] pci 0000:13:03.0: bridge window [io disabled] [ 1.365545] pci 0000:13:03.0: bridge window [mem disabled] [ 1.365809] pci 0000:13:03.0: bridge window [mem pref disabled] [ 1.366083] pci 0000:13:04.0: PCI bridge to [bus 17-17] [ 1.366346] pci 0000:13:04.0: bridge window [io disabled] [ 1.366615] pci 0000:13:04.0: bridge window [mem disabled] [ 1.366886] pci 0000:13:04.0: bridge window [mem pref disabled] [ 1.367157] pci 0000:13:06.0: PCI bridge to [bus 18-18] [ 1.367418] pci 0000:13:06.0: bridge window [io disabled] [ 1.367682] pci 0000:13:06.0: bridge window [mem disabled] [ 1.367955] pci 0000:13:06.0: bridge window [mem pref disabled] [ 1.368226] pci 0000:19:00.0: PCI bridge to [bus 1a-1a] [ 1.368486] pci 0000:19:00.0: bridge window [io disabled] [ 1.368754] pci 0000:19:00.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.369029] pci 0000:19:00.0: bridge window [mem pref disabled] [ 1.369301] pci 0000:13:07.0: PCI bridge to [bus 19-1a] [ 1.369561] pci 0000:13:07.0: bridge window [io disabled] [ 1.369836] pci 0000:13:07.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.370102] pci 0000:13:07.0: bridge window [mem pref disabled] [ 1.370373] pci 0000:13:08.0: PCI bridge to [bus 1b-1b] [ 1.370634] pci 0000:13:08.0: bridge window [io disabled] [ 1.370907] pci 0000:13:08.0: bridge window [mem disabled] [ 1.371172] pci 0000:13:08.0: bridge window [mem pref disabled] [ 1.371443] pci 0000:13:0a.0: PCI bridge to [bus 1c-1c] [ 1.371703] pci 0000:13:0a.0: bridge window [io disabled] [ 1.371976] pci 0000:13:0a.0: bridge window [mem disabled] [ 1.372241] pci 0000:13:0a.0: bridge window [mem pref disabled] [ 1.372512] pci 0000:13:0b.0: PCI bridge to [bus 1d-1d] [ 1.372773] pci 0000:13:0b.0: bridge window [io disabled] [ 1.373047] pci 0000:13:0b.0: bridge window [mem disabled] [ 1.373312] pci 0000:13:0b.0: bridge window [mem pref disabled] [ 1.373583] pci 0000:12:00.0: PCI bridge to [bus 13-1d] [ 1.373852] pci 0000:12:00.0: bridge window [io 0xe000-0xefff] [ 1.374120] pci 0000:12:00.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.374389] pci 0000:12:00.0: bridge window [mem pref disabled] [ 1.374659] pci 0000:03:05.0: PCI bridge to [bus 12-1d] [ 1.374927] pci 0000:03:05.0: bridge window [io 0xe000-0xefff] [ 1.375192] pci 0000:03:05.0: bridge window [mem 0xf9200000-0xf92fffff] [ 1.375457] pci 0000:03:05.0: bridge window [mem pref disabled] [ 1.375724] pci 0000:02:00.0: PCI bridge to [bus 03-1d] [ 1.375990] pci 0000:02:00.0: bridge window [io 0xe000-0xefff] [ 1.376256] pci 0000:02:00.0: bridge window [mem 0xf9200000-0xf93fffff] [ 1.376521] pci 0000:02:00.0: bridge window [mem pref disabled] [ 1.376780] pci 0000:00:02.0: PCI bridge to [bus 02-1d] [ 1.377041] pci 0000:00:02.0: bridge window [io 0xe000-0xefff] [ 1.377300] pci 0000:00:02.0: bridge window [mem 0xf9200000-0xf94fffff] [ 1.377559] pci 0000:00:02.0: bridge window [mem pref disabled] [ 1.377824] pci 0000:00:02.2: PCI bridge to [bus 1e-1e] [ 1.378078] pci 0000:00:02.2: bridge window [io disabled] [ 1.378341] pci 0000:00:02.2: bridge window [mem 0xf9600000-0xf96fffff] [ 1.378606] pci 0000:00:02.2: bridge window [mem pref disabled] [ 1.378877] pci 0000:00:03.0: PCI bridge to [bus 1f-1f] [ 1.379138] pci 0000:00:03.0: bridge window [io disabled] [ 1.379402] pci 0000:00:03.0: bridge window [mem disabled] [ 1.379667] pci 0000:00:03.0: bridge window [mem pref disabled] [ 1.379941] pci 0000:21:07.0: BAR 14: can't assign mem (size 0x200000) [ 1.380205] pci 0000:21:07.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.380469] pci 0000:21:07.0: BAR 13: can't assign io (size 0x1000) [ 1.380733] pci 0000:21:06.0: BAR 14: can't assign mem (size 0x200000) [ 1.381000] pci 0000:21:06.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.381264] pci 0000:21:06.0: BAR 13: can't assign io (size 0x1000) [ 1.381528] pci 0000:21:05.0: BAR 14: can't assign mem (size 0x200000) [ 1.381791] pci 0000:21:05.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.382061] pci 0000:21:05.0: BAR 13: can't assign io (size 0x1000) [ 1.382324] pci 0000:21:04.0: BAR 14: can't assign mem (size 0x200000) [ 1.382588] pci 0000:21:04.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.382858] pci 0000:21:04.0: BAR 13: can't assign io (size 0x1000) [ 1.383120] pci 0000:21:03.0: BAR 14: can't assign mem (size 0x200000) [ 1.383384] pci 0000:21:03.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.383650] pci 0000:21:03.0: BAR 13: can't assign io (size 0x1000) [ 1.383919] pci 0000:21:02.0: BAR 14: can't assign mem (size 0x200000) [ 1.384184] pci 0000:21:02.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.384449] pci 0000:21:02.0: BAR 13: can't assign io (size 0x1000) [ 1.384713] pci 0000:21:01.0: BAR 14: can't assign mem (size 0x200000) [ 1.384986] pci 0000:21:01.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.385250] pci 0000:21:01.0: BAR 13: can't assign io (size 0x1000) [ 1.385515] pci 0000:21:00.0: BAR 14: can't assign mem (size 0x200000) [ 1.385777] pci 0000:21:00.0: BAR 15: can't assign mem pref (size 0x200000) [ 1.386048] pci 0000:21:00.0: BAR 13: can't assign io (size 0x1000) [ 1.386312] pci 0000:21:00.0: PCI bridge to [bus 22-22] [ 1.386573] pci 0000:21:00.0: bridge window [io disabled] [ 1.386842] pci 0000:21:00.0: bridge window [mem disabled] [ 1.387106] pci 0000:21:00.0: bridge window [mem pref disabled] [ 1.387371] pci 0000:21:01.0: PCI bridge to [bus 23-23] [ 1.387631] pci 0000:21:01.0: bridge window [io disabled] [ 1.387900] pci 0000:21:01.0: bridge window [mem disabled] [ 1.388163] pci 0000:21:01.0: bridge window [mem pref disabled] [ 1.388431] pci 0000:21:02.0: PCI bridge to [bus 24-24] [ 1.388692] pci 0000:21:02.0: bridge window [io disabled] [ 1.388963] pci 0000:21:02.0: bridge window [mem disabled] [ 1.389225] pci 0000:21:02.0: bridge window [mem pref disabled] [ 1.389490] pci 0000:21:03.0: PCI bridge to [bus 25-25] [ 1.389752] pci 0000:21:03.0: bridge window [io disabled] [ 1.390022] pci 0000:21:03.0: bridge window [mem disabled] [ 1.390284] pci 0000:21:03.0: bridge window [mem pref disabled] [ 1.390549] pci 0000:21:04.0: PCI bridge to [bus 26-26] [ 1.390815] pci 0000:21:04.0: bridge window [io disabled] [ 1.391072] pci 0000:21:04.0: bridge window [mem disabled] [ 1.391329] pci 0000:21:04.0: bridge window [mem pref disabled] [ 1.391588] pci 0000:21:05.0: PCI bridge to [bus 27-27] [ 1.391848] pci 0000:21:05.0: bridge window [io disabled] [ 1.392106] pci 0000:21:05.0: bridge window [mem disabled] [ 1.392362] pci 0000:21:05.0: bridge window [mem pref disabled] [ 1.392628] pci 0000:21:06.0: PCI bridge to [bus 28-28] [ 1.392896] pci 0000:21:06.0: bridge window [io disabled] [ 1.393158] pci 0000:21:06.0: bridge window [mem disabled] [ 1.393422] pci 0000:21:06.0: bridge window [mem pref disabled] [ 1.393686] pci 0000:21:07.0: PCI bridge to [bus 29-29] [ 1.393954] pci 0000:21:07.0: bridge window [io disabled] [ 1.394217] pci 0000:21:07.0: bridge window [mem disabled] [ 1.394482] pci 0000:21:07.0: bridge window [mem pref disabled] [ 1.394747] pci 0000:20:00.1: PCI bridge to [bus 21-29] [ 1.395014] pci 0000:20:00.1: bridge window [io disabled] [ 1.395277] pci 0000:20:00.1: bridge window [mem disabled] [ 1.395539] pci 0000:20:00.1: bridge window [mem pref disabled] [ 1.395810] pci 0000:00:03.2: PCI bridge to [bus 20-29] [ 1.396069] pci 0000:00:03.2: bridge window [io disabled] [ 1.396334] pci 0000:00:03.2: bridge window [mem 0xe8000000-0xf80fffff] [ 1.396599] pci 0000:00:03.2: bridge window [mem pref disabled] [ 1.396872] pci 0000:00:11.0: PCI bridge to [bus 2a-2a] [ 1.397135] pci 0000:00:11.0: bridge window [io disabled] [ 1.397400] pci 0000:00:11.0: bridge window [mem disabled] [ 1.397665] pci 0000:00:11.0: bridge window [mem pref disabled] [ 1.397939] pci 0000:00:1c.0: PCI bridge to [bus 2b-2c] [ 1.398201] pci 0000:00:1c.0: bridge window [io 0xd000-0xdfff] [ 1.398465] pci 0000:00:1c.0: bridge window [mem 0xf9500000-0xf95fffff] [ 1.398729] pci 0000:00:1c.0: bridge window [mem pref disabled] [ 1.399003] pci 0000:00:1e.0: PCI bridge to [bus 2d-2d] [ 1.399264] pci 0000:00:1e.0: bridge window [io disabled] [ 1.399525] pci 0000:00:1e.0: bridge window [mem 0xf8800000-0xf90fffff] [ 1.399796] pci 0000:00:1e.0: bridge window [mem 0xfa000000-0xfaffffff 64bit pref] [ 1.400281] pci 0000:00:01.0: PCI INT A -> GSI 26 (level, low) -> IRQ 26 [ 1.400548] pci 0000:00:01.0: setting latency timer to 64 [ 1.400555] pci 0000:00:02.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 1.400827] pci 0000:00:02.0: setting latency timer to 64 [ 1.400831] pci 0000:02:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 1.401097] pci 0000:02:00.0: setting latency timer to 64 [ 1.401104] pci 0000:03:01.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 1.401368] pci 0000:03:01.0: setting latency timer to 64 [ 1.401374] pci 0000:03:02.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 1.401640] pci 0000:03:02.0: setting latency timer to 64 [ 1.401646] pci 0000:03:03.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 1.401916] pci 0000:03:03.0: setting latency timer to 64 [ 1.401920] pci 0000:03:04.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 1.402185] pci 0000:03:04.0: setting latency timer to 64 [ 1.402194] pci 0000:07:00.0: setting latency timer to 64 [ 1.402203] pci 0000:08:02.0: setting latency timer to 64 [ 1.402212] pci 0000:08:03.0: setting latency timer to 64 [ 1.402221] pci 0000:0a:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 1.402490] pci 0000:0a:00.0: setting latency timer to 64 [ 1.402500] pci 0000:08:04.0: setting latency timer to 64 [ 1.402509] pci 0000:08:06.0: setting latency timer to 64 [ 1.402519] pci 0000:08:07.0: setting latency timer to 64 [ 1.402528] pci 0000:08:08.0: setting latency timer to 64 [ 1.402537] pci 0000:08:0a.0: setting latency timer to 64 [ 1.402547] pci 0000:08:0b.0: setting latency timer to 64 [ 1.402551] pci 0000:03:05.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 1.402821] pci 0000:03:05.0: setting latency timer to 64 [ 1.402829] pci 0000:12:00.0: setting latency timer to 64 [ 1.402839] pci 0000:13:02.0: setting latency timer to 64 [ 1.402849] pci 0000:14:00.0: setting latency timer to 64 [ 1.402859] pci 0000:13:03.0: setting latency timer to 64 [ 1.402868] pci 0000:13:04.0: setting latency timer to 64 [ 1.402877] pci 0000:13:06.0: setting latency timer to 64 [ 1.402887] pci 0000:13:07.0: setting latency timer to 64 [ 1.402895] pci 0000:19:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 1.403163] pci 0000:19:00.0: setting latency timer to 64 [ 1.403173] pci 0000:13:08.0: setting latency timer to 64 [ 1.403182] pci 0000:13:0a.0: setting latency timer to 64 [ 1.403191] pci 0000:13:0b.0: setting latency timer to 64 [ 1.403197] pci 0000:00:02.2: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 1.403462] pci 0000:00:02.2: setting latency timer to 64 [ 1.403469] pci 0000:00:03.0: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 1.403735] pci 0000:00:03.0: setting latency timer to 64 [ 1.403739] pci 0000:00:03.2: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 1.404010] pci 0000:00:03.2: setting latency timer to 64 [ 1.404015] pci 0000:20:00.1: setting latency timer to 64 [ 1.404022] pci 0000:21:00.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 [ 1.404285] pci 0000:21:00.0: setting latency timer to 64 [ 1.404291] pci 0000:21:01.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 1.404556] pci 0000:21:01.0: setting latency timer to 64 [ 1.404563] pci 0000:21:02.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 1.409972] pci 0000:21:02.0: setting latency timer to 64 [ 1.409979] pci 0000:21:03.0: PCI INT A -> GSI 46 (level, low) -> IRQ 46 [ 1.410245] pci 0000:21:03.0: setting latency timer to 64 [ 1.410249] pci 0000:21:04.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 [ 1.410516] pci 0000:21:04.0: setting latency timer to 64 [ 1.410521] pci 0000:21:05.0: PCI INT A -> GSI 45 (level, low) -> IRQ 45 [ 1.410789] pci 0000:21:05.0: setting latency timer to 64 [ 1.410794] pci 0000:21:06.0: PCI INT A -> GSI 44 (level, low) -> IRQ 44 [ 1.411055] pci 0000:21:06.0: setting latency timer to 64 [ 1.411059] pci 0000:21:07.0: PCI INT A -> GSI 46 (level, low) -> IRQ 46 [ 1.411320] pci 0000:21:07.0: setting latency timer to 64 [ 1.411327] pci 0000:00:11.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 1.411594] pci 0000:00:11.0: setting latency timer to 64 [ 1.411601] pci 0000:00:1c.0: PCI INT A -> GSI 17 (level, low) -> IRQ 17 [ 1.411871] pci 0000:00:1c.0: setting latency timer to 64 [ 1.411876] pci 0000:00:1e.0: setting latency timer to 64 [ 1.411880] pci_bus 0000:00: resource 4 [io 0x0000-0x03af] [ 1.411881] pci_bus 0000:00: resource 5 [io 0x03e0-0x0cf7] [ 1.411882] pci_bus 0000:00: resource 6 [io 0x03b0-0x03df] [ 1.411884] pci_bus 0000:00: resource 7 [io 0x0d00-0xffff] [ 1.411885] pci_bus 0000:00: resource 8 [mem 0x000a0000-0x000bffff] [ 1.411886] pci_bus 0000:00: resource 9 [mem 0x000c0000-0x000dffff] [ 1.411888] pci_bus 0000:00: resource 10 [mem 0xfed08000-0xfed08fff] [ 1.411889] pci_bus 0000:00: resource 11 [mem 0xfed0e000-0xfed0ffff] [ 1.411891] pci_bus 0000:00: resource 12 [mem 0x80000000-0xfbffffff] [ 1.411892] pci_bus 0000:02: resource 0 [io 0xe000-0xefff] [ 1.411894] pci_bus 0000:02: resource 1 [mem 0xf9200000-0xf94fffff] [ 1.411895] pci_bus 0000:03: resource 0 [io 0xe000-0xefff] [ 1.411896] pci_bus 0000:03: resource 1 [mem 0xf9200000-0xf93fffff] [ 1.411898] pci_bus 0000:07: resource 1 [mem 0xf9300000-0xf93fffff] [ 1.411899] pci_bus 0000:08: resource 1 [mem 0xf9300000-0xf93fffff] [ 1.411901] pci_bus 0000:0a: resource 1 [mem 0xf9300000-0xf93fffff] [ 1.411902] pci_bus 0000:0b: resource 1 [mem 0xf9300000-0xf93fffff] [ 1.411904] pci_bus 0000:12: resource 0 [io 0xe000-0xefff] [ 1.411905] pci_bus 0000:12: resource 1 [mem 0xf9200000-0xf92fffff] [ 1.411906] pci_bus 0000:13: resource 0 [io 0xe000-0xefff] [ 1.411908] pci_bus 0000:13: resource 1 [mem 0xf9200000-0xf92fffff] [ 1.411909] pci_bus 0000:14: resource 0 [io 0xe000-0xefff] [ 1.411910] pci_bus 0000:15: resource 0 [io 0xe000-0xefff] [ 1.411912] pci_bus 0000:19: resource 1 [mem 0xf9200000-0xf92fffff] [ 1.411913] pci_bus 0000:1a: resource 1 [mem 0xf9200000-0xf92fffff] [ 1.411915] pci_bus 0000:1e: resource 1 [mem 0xf9600000-0xf96fffff] [ 1.411916] pci_bus 0000:20: resource 1 [mem 0xe8000000-0xf80fffff] [ 1.411918] pci_bus 0000:2b: resource 0 [io 0xd000-0xdfff] [ 1.411919] pci_bus 0000:2b: resource 1 [mem 0xf9500000-0xf95fffff] [ 1.411921] pci_bus 0000:2d: resource 1 [mem 0xf8800000-0xf90fffff] [ 1.411922] pci_bus 0000:2d: resource 2 [mem 0xfa000000-0xfaffffff 64bit pref] [ 1.411924] pci_bus 0000:2d: resource 4 [io 0x0000-0x03af] [ 1.411925] pci_bus 0000:2d: resource 5 [io 0x03e0-0x0cf7] [ 1.411926] pci_bus 0000:2d: resource 6 [io 0x03b0-0x03df] [ 1.411928] pci_bus 0000:2d: resource 7 [io 0x0d00-0xffff] [ 1.411929] pci_bus 0000:2d: resource 8 [mem 0x000a0000-0x000bffff] [ 1.411930] pci_bus 0000:2d: resource 9 [mem 0x000c0000-0x000dffff] [ 1.411932] pci_bus 0000:2d: resource 10 [mem 0xfed08000-0xfed08fff] [ 1.411933] pci_bus 0000:2d: resource 11 [mem 0xfed0e000-0xfed0ffff] [ 1.411934] pci_bus 0000:2d: resource 12 [mem 0x80000000-0xfbffffff] [ 1.411953] NET: Registered protocol family 2 [ 1.412504] IP route cache hash table entries: 524288 (order: 10, 4194304 bytes) [ 1.413809] TCP established hash table entries: 524288 (order: 11, 8388608 bytes) [ 1.415478] TCP bind hash table entries: 65536 (order: 8, 1048576 bytes) [ 1.415906] TCP: Hash tables configured (established 524288 bind 65536) [ 1.416173] TCP reno registered [ 1.416468] UDP hash table entries: 16384 (order: 7, 524288 bytes) [ 1.416852] UDP-Lite hash table entries: 16384 (order: 7, 524288 bytes) [ 1.417254] NET: Registered protocol family 1 [ 1.417580] RPC: Registered named UNIX socket transport module. [ 1.417852] RPC: Registered udp transport module. [ 1.418113] RPC: Registered tcp transport module. [ 1.418375] RPC: Registered tcp NFSv4.1 backchannel transport module. [ 1.418671] pci 0000:00:1a.0: EHCI: BIOS handoff [ 1.434728] pci 0000:00:1d.0: EHCI: BIOS handoff [ 1.449733] pci 0000:14:00.0: TI XIO2000a quirk detected; secondary bus fast back-to-back transfers disabled [ 1.450244] pci 0000:2d:04.0: Boot video device [ 1.450279] PCI: CLS 64 bytes, default 64 [ 1.450308] PCI-DMA: Using software bounce buffering for IO (SWIOTLB) [ 1.450573] Placing 64MB software IO TLB between ffff880079eb2000 - ffff88007deb2000 [ 1.451049] software IO TLB at phys 0x79eb2000 - 0x7deb2000 [ 1.508599] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 1.511214] VFS: Disk quotas dquot_6.5.2 [ 1.511528] Dquot-cache hash table entries: 512 (order 0, 4096 bytes) [ 1.512295] Installing knfsd (copyright (C) 1996 okir@monad.swb.de). [ 1.512799] msgmni has been set to 32768 [ 1.513333] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 1.513820] io scheduler noop registered [ 1.514081] io scheduler deadline registered [ 1.514380] io scheduler cfq registered (default) [ 1.515061] pcieport 0000:02:00.0: setting latency timer to 64 [ 1.515093] pcieport 0000:02:00.0: irq 64 for MSI/MSI-X [ 1.515154] pcieport 0000:03:01.0: setting latency timer to 64 [ 1.515181] pcieport 0000:03:01.0: irq 65 for MSI/MSI-X [ 1.515263] pcieport 0000:03:02.0: setting latency timer to 64 [ 1.515289] pcieport 0000:03:02.0: irq 66 for MSI/MSI-X [ 1.515345] pcieport 0000:03:03.0: setting latency timer to 64 [ 1.515373] pcieport 0000:03:03.0: irq 67 for MSI/MSI-X [ 1.515430] pcieport 0000:03:04.0: setting latency timer to 64 [ 1.515456] pcieport 0000:03:04.0: irq 68 for MSI/MSI-X [ 1.515514] pcieport 0000:03:05.0: setting latency timer to 64 [ 1.515551] pcieport 0000:03:05.0: irq 69 for MSI/MSI-X [ 1.515638] pcieport 0000:07:00.0: setting latency timer to 64 [ 1.515739] pcieport 0000:08:02.0: setting latency timer to 64 [ 1.515804] pcieport 0000:08:02.0: irq 70 for MSI/MSI-X [ 1.515892] pcieport 0000:08:03.0: setting latency timer to 64 [ 1.515958] pcieport 0000:08:03.0: irq 71 for MSI/MSI-X [ 1.516044] pcieport 0000:08:04.0: setting latency timer to 64 [ 1.516110] pcieport 0000:08:04.0: irq 72 for MSI/MSI-X [ 1.516196] pcieport 0000:08:06.0: setting latency timer to 64 [ 1.516262] pcieport 0000:08:06.0: irq 73 for MSI/MSI-X [ 1.516349] pcieport 0000:08:07.0: setting latency timer to 64 [ 1.516415] pcieport 0000:08:07.0: irq 74 for MSI/MSI-X [ 1.516501] pcieport 0000:08:08.0: setting latency timer to 64 [ 1.516576] pcieport 0000:08:08.0: irq 75 for MSI/MSI-X [ 1.516664] pcieport 0000:08:0a.0: setting latency timer to 64 [ 1.516729] pcieport 0000:08:0a.0: irq 76 for MSI/MSI-X [ 1.516816] pcieport 0000:08:0b.0: setting latency timer to 64 [ 1.516883] pcieport 0000:08:0b.0: irq 77 for MSI/MSI-X [ 1.516976] pcieport 0000:12:00.0: setting latency timer to 64 [ 1.517073] pcieport 0000:13:02.0: setting latency timer to 64 [ 1.517139] pcieport 0000:13:02.0: irq 78 for MSI/MSI-X [ 1.517225] pcieport 0000:13:03.0: setting latency timer to 64 [ 1.517291] pcieport 0000:13:03.0: irq 79 for MSI/MSI-X [ 1.517377] pcieport 0000:13:04.0: setting latency timer to 64 [ 1.517444] pcieport 0000:13:04.0: irq 80 for MSI/MSI-X [ 1.517530] pcieport 0000:13:06.0: setting latency timer to 64 [ 1.517604] pcieport 0000:13:06.0: irq 81 for MSI/MSI-X [ 1.517693] pcieport 0000:13:07.0: setting latency timer to 64 [ 1.517758] pcieport 0000:13:07.0: irq 82 for MSI/MSI-X [ 1.517844] pcieport 0000:13:08.0: setting latency timer to 64 [ 1.517910] pcieport 0000:13:08.0: irq 83 for MSI/MSI-X [ 1.517999] pcieport 0000:13:0a.0: setting latency timer to 64 [ 1.518064] pcieport 0000:13:0a.0: irq 84 for MSI/MSI-X [ 1.518152] pcieport 0000:13:0b.0: setting latency timer to 64 [ 1.518218] pcieport 0000:13:0b.0: irq 85 for MSI/MSI-X [ 1.518338] pcieport 0000:21:00.0: setting latency timer to 64 [ 1.518370] pcieport 0000:21:00.0: irq 86 for MSI/MSI-X [ 1.518432] pcieport 0000:21:01.0: setting latency timer to 64 [ 1.518463] pcieport 0000:21:01.0: irq 87 for MSI/MSI-X [ 1.518525] pcieport 0000:21:02.0: setting latency timer to 64 [ 1.518565] pcieport 0000:21:02.0: irq 88 for MSI/MSI-X [ 1.518628] pcieport 0000:21:03.0: setting latency timer to 64 [ 1.518660] pcieport 0000:21:03.0: irq 89 for MSI/MSI-X [ 1.518722] pcieport 0000:21:04.0: setting latency timer to 64 [ 1.518753] pcieport 0000:21:04.0: irq 90 for MSI/MSI-X [ 1.518818] pcieport 0000:21:05.0: setting latency timer to 64 [ 1.518849] pcieport 0000:21:05.0: irq 91 for MSI/MSI-X [ 1.518911] pcieport 0000:21:06.0: setting latency timer to 64 [ 1.518942] pcieport 0000:21:06.0: irq 92 for MSI/MSI-X [ 1.519005] pcieport 0000:21:07.0: setting latency timer to 64 [ 1.519036] pcieport 0000:21:07.0: irq 93 for MSI/MSI-X [ 1.519320] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input0 [ 1.519795] ACPI: Power Button [PWRB] [ 1.520092] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input1 [ 1.520563] ACPI: Power Button [PWRF] [ 1.520924] ACPI: acpi_idle registered with cpuidle [ 1.522176] Monitor-Mwait will be used to enter C-1 state [ 1.535200] Serial: 8250/16550 driver, 4 ports, IRQ sharing enabled [ 1.575719] Non-volatile memory driver v1.3 [ 1.575977] Linux agpgart interface v0.103 [ 1.576375] [drm] Initialized drm 1.1.0 20060810 [ 1.576638] [drm:i915_init] *ERROR* drm/i915 can't work without intel_agp module! [ 1.578225] brd: module loaded [ 1.579042] loop: module loaded [ 1.579484] ahci 0000:00:1f.2: version 3.0 [ 1.579497] ahci 0000:00:1f.2: PCI INT A -> GSI 18 (level, low) -> IRQ 18 [ 1.579798] ahci 0000:00:1f.2: irq 94 for MSI/MSI-X [ 1.590408] ahci 0000:00:1f.2: AHCI 0001.0300 32 slots 6 ports 6 Gbps 0x20 impl SATA mode [ 1.590871] ahci 0000:00:1f.2: flags: 64bit ncq sntf led clo pio slum part ems apst [ 1.591332] ahci 0000:00:1f.2: setting latency timer to 64 [ 1.591948] scsi0 : ahci [ 1.592286] scsi1 : ahci [ 1.592630] scsi2 : ahci [ 1.592950] scsi3 : ahci [ 1.593272] scsi4 : ahci [ 1.593610] scsi5 : ahci [ 1.593972] ata1: DUMMY [ 1.594227] ata2: DUMMY [ 1.594494] ata3: DUMMY [ 1.594751] ata4: DUMMY [ 1.595009] ata5: DUMMY [ 1.595263] ata6: SATA max UDMA/133 abar m2048@0xf8101000 port 0xf8101380 irq 94 [ 1.596033] e1000: Intel(R) PRO/1000 Network Driver - version 7.3.21-k8-NAPI [ 1.596297] e1000: Copyright (c) 1999-2006 Intel Corporation. [ 1.596612] e1000e: Intel(R) PRO/1000 Network Driver - 1.3.10-k2 [ 1.596869] e1000e: Copyright(c) 1999 - 2011 Intel Corporation. [ 1.597164] Intel(R) Gigabit Ethernet Network Driver - version 3.0.6-k2 [ 1.597436] Copyright (c) 2007-2011 Intel Corporation. [ 1.597713] igb 0000:2b:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 1.597984] igb 0000:2b:00.0: setting latency timer to 64 [ 1.598272] igb 0000:2b:00.0: irq 95 for MSI/MSI-X [ 1.598275] igb 0000:2b:00.0: irq 96 for MSI/MSI-X [ 1.598278] igb 0000:2b:00.0: irq 97 for MSI/MSI-X [ 1.598282] igb 0000:2b:00.0: irq 98 for MSI/MSI-X [ 1.598285] igb 0000:2b:00.0: irq 99 for MSI/MSI-X [ 1.598288] igb 0000:2b:00.0: irq 100 for MSI/MSI-X [ 1.598291] igb 0000:2b:00.0: irq 101 for MSI/MSI-X [ 1.598294] igb 0000:2b:00.0: irq 102 for MSI/MSI-X [ 1.598297] igb 0000:2b:00.0: irq 103 for MSI/MSI-X [ 1.598323] igb 0000:2b:00.0: 0 vfs allocated [ 1.650034] igb 0000:2b:00.0: Intel(R) Gigabit Ethernet Network Connection [ 1.650306] igb 0000:2b:00.0: eth0: (PCIe:5.0Gb/s:Width x4) 0c:c4:7a:07:d7:58 [ 1.650639] igb 0000:2b:00.0: eth0: PBA No: 104900-000 [ 1.650899] igb 0000:2b:00.0: Using MSI-X interrupts. 8 rx queue(s), 8 tx queue(s) [ 1.651386] igb 0000:2b:00.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 1.651660] igb 0000:2b:00.1: setting latency timer to 64 [ 1.651942] igb 0000:2b:00.1: irq 104 for MSI/MSI-X [ 1.651945] igb 0000:2b:00.1: irq 105 for MSI/MSI-X [ 1.651948] igb 0000:2b:00.1: irq 106 for MSI/MSI-X [ 1.651952] igb 0000:2b:00.1: irq 107 for MSI/MSI-X [ 1.651955] igb 0000:2b:00.1: irq 108 for MSI/MSI-X [ 1.651958] igb 0000:2b:00.1: irq 109 for MSI/MSI-X [ 1.651961] igb 0000:2b:00.1: irq 110 for MSI/MSI-X [ 1.651964] igb 0000:2b:00.1: irq 111 for MSI/MSI-X [ 1.651967] igb 0000:2b:00.1: irq 112 for MSI/MSI-X [ 1.651991] igb 0000:2b:00.1: 0 vfs allocated [ 1.707823] igb 0000:2b:00.1: Intel(R) Gigabit Ethernet Network Connection [ 1.708084] igb 0000:2b:00.1: eth1: (PCIe:5.0Gb/s:Width x4) 0c:c4:7a:07:d7:59 [ 1.708425] igb 0000:2b:00.1: eth1: PBA No: 104900-000 [ 1.708682] igb 0000:2b:00.1: Using MSI-X interrupts. 8 rx queue(s), 8 tx queue(s) [ 1.709185] e100: Intel(R) PRO/100 Network Driver, 3.5.24-k2-NAPI [ 1.709443] e100: Copyright(c) 1999-2006 Intel Corporation [ 1.709780] sky2: driver version 1.28 [ 1.710149] console [netcon0] enabled [ 1.710411] netconsole: network logging started [ 1.710768] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 1.711032] ehci_hcd: block sizes: qh 112 qtd 96 itd 192 sitd 96 [ 1.711043] ehci_hcd 0000:00:1a.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 1.711326] ehci_hcd 0000:00:1a.0: setting latency timer to 64 [ 1.711329] ehci_hcd 0000:00:1a.0: EHCI Host Controller [ 1.711599] drivers/usb/core/inode.c: creating file 'devices' [ 1.711606] drivers/usb/core/inode.c: creating file '001' [ 1.711642] ehci_hcd 0000:00:1a.0: new USB bus registered, assigned bus number 1 [ 1.712117] ehci_hcd 0000:00:1a.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 1.712120] ehci_hcd 0000:00:1a.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 1.712131] ehci_hcd 0000:00:1a.0: support lpm [ 1.712140] ehci_hcd 0000:00:1a.0: debug port 2 [ 1.712411] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 1.716283] ehci_hcd 0000:00:1a.0: cache line size of 64 is not supported [ 1.716284] ehci_hcd 0000:00:1a.0: supports USB remote wakeup [ 1.716295] ehci_hcd 0000:00:1a.0: irq 16, io mem 0xf8103000 [ 1.716560] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 1.720424] ehci_hcd 0000:00:1a.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 1.726133] ehci_hcd 0000:00:1a.0: USB 2.0 started, EHCI 1.00 [ 1.726405] usb usb1: default language 0x0409 [ 1.726409] usb usb1: udev 1, busnum 1, minor = 0 [ 1.726410] usb usb1: New USB device found, idVendor=1d6b, idProduct=0002 [ 1.726675] usb usb1: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 1.727155] usb usb1: Product: EHCI Host Controller [ 1.727417] usb usb1: Manufacturer: Linux 3.0.8 ehci_hcd [ 1.727677] usb usb1: SerialNumber: 0000:00:1a.0 [ 1.727983] usb usb1: usb_probe_device [ 1.727985] usb usb1: configuration #1 chosen from 1 choice [ 1.727989] usb usb1: adding 1-0:1.0 (config #1, interface 0) [ 1.728021] hub 1-0:1.0: usb_probe_interface [ 1.728022] hub 1-0:1.0: usb_probe_interface - got id [ 1.728023] hub 1-0:1.0: USB hub found [ 1.728288] hub 1-0:1.0: 2 ports detected [ 1.728545] hub 1-0:1.0: standalone hub [ 1.728546] hub 1-0:1.0: no power switching (usb 1.0) [ 1.728547] hub 1-0:1.0: individual port over-current protection [ 1.728548] hub 1-0:1.0: power on to power good time: 20ms [ 1.728551] hub 1-0:1.0: local power source is good [ 1.728552] hub 1-0:1.0: trying to enable port power on non-switchable hub [ 1.728566] drivers/usb/core/inode.c: creating file '001' [ 1.728607] ehci_hcd 0000:00:1d.0: PCI INT A -> GSI 23 (level, low) -> IRQ 23 [ 1.728878] ehci_hcd 0000:00:1d.0: setting latency timer to 64 [ 1.728880] ehci_hcd 0000:00:1d.0: EHCI Host Controller [ 1.729148] drivers/usb/core/inode.c: creating file '002' [ 1.729182] ehci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 1.729658] ehci_hcd 0000:00:1d.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 1.729661] ehci_hcd 0000:00:1d.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 1.729668] ehci_hcd 0000:00:1d.0: support lpm [ 1.729677] ehci_hcd 0000:00:1d.0: debug port 2 [ 1.729939] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 1.733827] ehci_hcd 0000:00:1d.0: cache line size of 64 is not supported [ 1.733828] ehci_hcd 0000:00:1d.0: supports USB remote wakeup [ 1.733838] ehci_hcd 0000:00:1d.0: irq 23, io mem 0xf8102000 [ 1.734094] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 1.737966] ehci_hcd 0000:00:1d.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 1.743100] ehci_hcd 0000:00:1d.0: USB 2.0 started, EHCI 1.00 [ 1.743368] usb usb2: default language 0x0409 [ 1.743371] usb usb2: udev 1, busnum 2, minor = 128 [ 1.743372] usb usb2: New USB device found, idVendor=1d6b, idProduct=0002 [ 1.743635] usb usb2: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 1.744111] usb usb2: Product: EHCI Host Controller [ 1.744373] usb usb2: Manufacturer: Linux 3.0.8 ehci_hcd [ 1.744633] usb usb2: SerialNumber: 0000:00:1d.0 [ 1.744938] usb usb2: usb_probe_device [ 1.744939] usb usb2: configuration #1 chosen from 1 choice [ 1.744943] usb usb2: adding 2-0:1.0 (config #1, interface 0) [ 1.744972] hub 2-0:1.0: usb_probe_interface [ 1.744973] hub 2-0:1.0: usb_probe_interface - got id [ 1.744974] hub 2-0:1.0: USB hub found [ 1.745244] hub 2-0:1.0: 2 ports detected [ 1.745500] hub 2-0:1.0: standalone hub [ 1.745501] hub 2-0:1.0: no power switching (usb 1.0) [ 1.745502] hub 2-0:1.0: individual port over-current protection [ 1.745503] hub 2-0:1.0: power on to power good time: 20ms [ 1.745505] hub 2-0:1.0: local power source is good [ 1.745506] hub 2-0:1.0: trying to enable port power on non-switchable hub [ 1.745516] drivers/usb/core/inode.c: creating file '001' [ 1.745579] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 1.745837] ohci_hcd: block sizes: ed 80 td 96 [ 1.745869] uhci_hcd: USB Universal Host Controller Interface driver [ 1.746207] usbcore: registered new interface driver usblp [ 1.746468] Initializing USB Mass Storage driver... [ 1.746761] usbcore: registered new interface driver usb-storage [ 1.747022] USB Mass Storage support registered. [ 1.747320] usbcore: registered new interface driver libusual [ 1.747682] i8042: PNP: No PS/2 controller found. Probing ports directly. [ 1.748803] i8042: No controller found [ 1.749095] mousedev: PS/2 mouse device common for all mice [ 1.749494] rtc_cmos 00:03: RTC can wake from S4 [ 1.749840] rtc_cmos 00:03: rtc core: registered rtc_cmos as rtc0 [ 1.750133] rtc0: alarms up to one month, y3k, 114 bytes nvram [ 1.750430] i801_smbus 0000:00:1f.3: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 1.751124] device-mapper: ioctl: 4.20.0-ioctl (2011-02-02) initialised: dm-devel@redhat.com [ 1.751634] cpuidle: using governor ladder [ 1.751890] cpuidle: using governor menu [ 1.752158] EFI Variables Facility v0.08 2004-May-17 [ 1.753182] usbcore: registered new interface driver usbhid [ 1.753446] usbhid: USB HID core driver [ 1.753928] ALSA device list: [ 1.754191] No soundcards found. [ 1.754470] Netfilter messages via NETLINK v0.30. [ 1.754741] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 1.755101] ctnetlink v0.93: registering with nfnetlink. [ 1.755585] TCP cubic registered [ 1.755841] Initializing XFRM netlink socket [ 1.756251] NET: Registered protocol family 10 [ 1.757022] IPv6 over IPv4 tunneling driver [ 1.757603] NET: Registered protocol family 17 [ 1.757869] Registering the dns_resolver key type [ 1.758226] PM: Hibernation image not present or could not be loaded. [ 1.759230] Magic number: 6:484:486 [ 1.843913] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 1.843916] hub 1-0:1.0: port 1: status 0501 change 0001 [ 1.844907] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 1.844909] hub 2-0:1.0: port 1: status 0501 change 0001 [ 1.845562] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 1.899805] ata6: SATA link up 1.5 Gbps (SStatus 113 SControl 300) [ 1.903389] ata6.00: ATAPI: TSSTcorp CDDVDW SN-208FB, JF01, max UDMA/100 [ 1.908050] ata6.00: configured for UDMA/100 [ 1.913582] scsi 5:0:0:0: CD-ROM TSSTcorp CDDVDW SN-208FB JF01 PQ: 0 ANSI: 5 [ 1.919249] sr0: scsi3-mmc drive: 24x/24x writer dvd-ram cd/rw xa/form2 cdda tray [ 1.919709] cdrom: Uniform CD-ROM driver Revision: 3.20 [ 1.920051] sr 5:0:0:0: Attached scsi CD-ROM sr0 [ 1.920105] sr 5:0:0:0: Attached scsi generic sg0 type 5 [ 1.927530] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 1.943712] hub 1-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 1.943718] hub 1-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 1.994915] ehci_hcd 0000:00:1a.0: port 1 high speed [ 1.994918] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 2.045513] usb 1-1: new high speed USB device number 2 using ehci_hcd [ 2.096714] ehci_hcd 0000:00:1a.0: port 1 high speed [ 2.096717] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 2.159346] ehci_hcd 0000:00:1a.0: set dev address 2 for port 1 [ 2.159350] ehci_hcd 0000:00:1a.0: LPM: no device attached [ 2.159597] usb 1-1: udev 2, busnum 1, minor = 1 [ 2.159598] usb 1-1: New USB device found, idVendor=8087, idProduct=0024 [ 2.159862] usb 1-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 2.160176] usb 1-1: usb_probe_device [ 2.160177] usb 1-1: configuration #1 chosen from 1 choice [ 2.160223] usb 1-1: adding 1-1:1.0 (config #1, interface 0) [ 2.160254] hub 1-1:1.0: usb_probe_interface [ 2.160256] hub 1-1:1.0: usb_probe_interface - got id [ 2.160257] hub 1-1:1.0: USB hub found [ 2.160593] hub 1-1:1.0: 6 ports detected [ 2.160854] hub 1-1:1.0: standalone hub [ 2.160855] hub 1-1:1.0: individual port power switching [ 2.160856] hub 1-1:1.0: individual port over-current protection [ 2.160857] hub 1-1:1.0: Single TT [ 2.160858] hub 1-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 2.160860] hub 1-1:1.0: power on to power good time: 100ms [ 2.161092] hub 1-1:1.0: local power source is good [ 2.161093] hub 1-1:1.0: enabling power on all ports [ 2.161848] drivers/usb/core/inode.c: creating file '002' [ 2.161856] hub 2-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 2.161860] hub 2-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 2.212361] ehci_hcd 0000:00:1d.0: port 1 high speed [ 2.212363] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 2.261646] hub 1-1:1.0: port 5: status 0101 change 0001 [ 2.263081] usb 2-1: new high speed USB device number 2 using ehci_hcd [ 2.314288] ehci_hcd 0000:00:1d.0: port 1 high speed [ 2.314290] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 2.360892] usb 1-1: link qh256-0001/ffff88085db96b00 start 1 [1/0 us] [ 2.376921] ehci_hcd 0000:00:1d.0: set dev address 2 for port 1 [ 2.376924] ehci_hcd 0000:00:1d.0: LPM: no device attached [ 2.377170] usb 2-1: udev 2, busnum 2, minor = 129 [ 2.377172] usb 2-1: New USB device found, idVendor=8087, idProduct=0024 [ 2.377434] usb 2-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 2.377735] usb 2-1: usb_probe_device [ 2.377737] usb 2-1: configuration #1 chosen from 1 choice [ 2.377799] usb 2-1: adding 2-1:1.0 (config #1, interface 0) [ 2.377829] hub 2-1:1.0: usb_probe_interface [ 2.377830] hub 2-1:1.0: usb_probe_interface - got id [ 2.377831] hub 2-1:1.0: USB hub found [ 2.383533] hub 2-1:1.0: 8 ports detected [ 2.383787] hub 2-1:1.0: standalone hub [ 2.383788] hub 2-1:1.0: individual port power switching [ 2.383789] hub 2-1:1.0: individual port over-current protection [ 2.383791] hub 2-1:1.0: Single TT [ 2.383792] hub 2-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 2.383793] hub 2-1:1.0: power on to power good time: 100ms [ 2.384031] hub 2-1:1.0: local power source is good [ 2.384033] hub 2-1:1.0: enabling power on all ports [ 2.385034] drivers/usb/core/inode.c: creating file '002' [ 2.385041] hub 1-1:1.0: state 7 ports 6 chg 0020 evt 0000 [ 2.385157] hub 1-1:1.0: port 5, status 0101, change 0000, 12 Mb/s [ 2.395885] hub 1-1:1.0: port 5 not reset yet, waiting 10ms [ 2.449720] Refined TSC clocksource calibration: 2799.999 MHz. [ 2.449983] Switching to clocksource tsc [ 2.457764] usb 1-1.5: new full speed USB device number 3 using ehci_hcd [ 2.468741] hub 1-1:1.0: port 5 not reset yet, waiting 10ms [ 2.484708] hub 2-1:1.0: port 1: status 0101 change 0001 [ 2.543221] usb 1-1.5: skipped 1 descriptor after interface [ 2.543223] usb 1-1.5: skipped 1 descriptor after interface [ 2.543469] usb 1-1.5: default language 0x0409 [ 2.543969] usb 1-1.5: udev 3, busnum 1, minor = 2 [ 2.543970] usb 1-1.5: New USB device found, idVendor=0557, idProduct=2221 [ 2.544235] usb 1-1.5: New USB device strings: Mfr=1, Product=2, SerialNumber=0 [ 2.544702] usb 1-1.5: Product: Hermon USB hidmouse Device [ 2.544962] usb 1-1.5: Manufacturer: Winbond Electronics Corp [ 2.545265] usb 1-1.5: usb_probe_device [ 2.545267] usb 1-1.5: configuration #1 chosen from 1 choice [ 2.545470] usb 1-1.5: adding 1-1.5:1.0 (config #1, interface 0) [ 2.545500] usbhid 1-1.5:1.0: usb_probe_interface [ 2.545501] usbhid 1-1.5:1.0: usb_probe_interface - got id [ 2.546053] input: Winbond Electronics Corp Hermon USB hidmouse Device as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.5/1-1.5:1.0/input/input2 [ 2.546597] generic-usb 0003:0557:2221.0001: input,hidraw0: USB HID v1.00 Mouse [Winbond Electronics Corp Hermon USB hidmouse Device] on usb-0000:00:1a.0-1.5/input0 [ 2.547277] usb 1-1.5: adding 1-1.5:1.1 (config #1, interface 1) [ 2.547306] usbhid 1-1.5:1.1: usb_probe_interface [ 2.547307] usbhid 1-1.5:1.1: usb_probe_interface - got id [ 2.547801] input: Winbond Electronics Corp Hermon USB hidmouse Device as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.5/1-1.5:1.1/input/input3 [ 2.548296] usb 1-1.5: link qh8-0601/ffff88085db96d00 start 2 [1/2 us] [ 2.548349] generic-usb 0003:0557:2221.0002: input,hidraw1: USB HID v1.00 Keyboard [Winbond Electronics Corp Hermon USB hidmouse Device] on usb-0000:00:1a.0-1.5/input1 [ 2.549054] drivers/usb/core/inode.c: creating file '003' [ 2.549062] hub 1-1:1.0: state 7 ports 6 chg 0000 evt 0020 [ 2.585446] usb 2-1: link qh256-0001/ffff88085db96d80 start 1 [1/0 us] [ 2.585454] hub 2-1:1.0: state 7 ports 8 chg 0002 evt 0000 [ 2.585514] hub 2-1:1.0: port 1, status 0101, change 0000, 12 Mb/s [ 2.596491] hub 2-1:1.0: port 1 not reset yet, waiting 10ms [ 2.658372] usb 2-1.1: new low speed USB device number 3 using ehci_hcd [ 2.670346] hub 2-1:1.0: port 1 not reset yet, waiting 10ms [ 2.748070] usb 2-1.1: skipped 1 descriptor after interface [ 2.748072] usb 2-1.1: skipped 1 descriptor after interface [ 2.748693] usb 2-1.1: default language 0x0409 [ 2.752686] usb 2-1.1: udev 3, busnum 2, minor = 130 [ 2.752687] usb 2-1.1: New USB device found, idVendor=0557, idProduct=2221 [ 2.752952] usb 2-1.1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 [ 2.753425] usb 2-1.1: Product: UC-10KM V1.3.124 [ 2.753685] usb 2-1.1: Manufacturer: ATEN [ 2.753944] usb 2-1.1: SerialNumber: USB Composite device [ 2.754243] usb 2-1.1: usb_probe_device [ 2.754245] usb 2-1.1: configuration #1 chosen from 1 choice [ 2.755805] usb 2-1.1: adding 2-1.1:1.0 (config #1, interface 0) [ 2.757076] usbhid 2-1.1:1.0: usb_probe_interface [ 2.757077] usbhid 2-1.1:1.0: usb_probe_interface - got id [ 2.761642] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.1/2-1.1:1.0/input/input4 [ 2.762132] usb 2-1.1: link qh8-0601/ffff88085db96f00 start 2 [1/2 us] [ 2.762185] generic-usb 0003:0557:2221.0003: input,hidraw2: USB HID v1.10 Keyboard [ATEN UC-10KM V1.3.124] on usb-0000:00:1d.0-1.1/input0 [ 2.762671] usb 2-1.1: adding 2-1.1:1.1 (config #1, interface 1) [ 2.763688] usbhid 2-1.1:1.1: usb_probe_interface [ 2.763689] usbhid 2-1.1:1.1: usb_probe_interface - got id [ 2.767854] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.1/2-1.1:1.1/input/input5 [ 2.768407] generic-usb 0003:0557:2221.0004: input,hidraw3: USB HID v1.10 Mouse [ATEN UC-10KM V1.3.124] on usb-0000:00:1d.0-1.1/input1 [ 2.768892] drivers/usb/core/inode.c: creating file '003' [ 5.270604] igb: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 5.272095] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 5.282169] Sending DHCP requests . [ 5.432289] igb: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 5.433827] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 8.335189] . [ 10.084370] DHCP/BOOTP: Reply not for us, op[2] xid[79d13d33] [ 13.303464] ., OK [ 13.314445] IP-Config: Got DHCP answer from 10.68.10.100, my address is 10.68.10.179 [ 13.359483] IP-Config: Complete: [ 13.359739] device=eth0, addr=10.68.10.179, mask=255.255.255.0, gw=10.68.10.1, [ 13.360139] host=k1test0, domain=kagra.icrr.u-tokyo.ac.jp, nis-domain=(none), [ 13.360657] bootserver=10.68.10.100, rootserver=10.68.10.100, rootpath= [ 13.361338] md: Waiting for all devices to be available before autodetect [ 13.361600] md: If you don't use raid, use raid=noautodetect [ 13.361955] md: Autodetecting RAID arrays. [ 13.362215] md: Scanned 0 and added 0 devices. [ 13.362475] md: autorun ... [ 13.362730] md: ... autorun DONE. [ 13.366434] VFS: Mounted root (nfs filesystem) readonly on device 0:14. [ 13.367571] Freeing unused kernel memory: 628k freed [ 13.367897] Write protecting the kernel read-only data: 10240k [ 13.369763] Freeing unused kernel memory: 724k freed [ 13.372994] Freeing unused kernel memory: 1368k freed [ 13.478032] hostname used greatest stack depth: 4088 bytes left [ 13.532351] mount.nfs used greatest stack depth: 3848 bytes left [ 14.481471] dis_kosif: Poll provider thread started [ 14.541495] dis_dx: ================================================================ [ 14.541964] dis_dx: Dolphin DX Driver [ 14.542220] dis_dx: Vendor 9902, Device 0101 [ 14.542476] dis_dx: ================================================================ [ 14.542954] dis_dx 0000:20:00.0: PCI INT A -> GSI 42 (level, low) -> IRQ 42 [ 14.543221] Found write combining in PAT1 [ 14.543525] dis_dx: mapped BAR0 (len = 0x40000) to 0xffffc90014480000; gw_start = 0xf8000000 [ 14.544066] dis_dx: mapped pi4 segment to 0xffffc90014080000 (BAR5, len = 0x100000) [ 14.558308] dis_dx 0000:20:00.0: setting latency timer to 64 [ 14.558337] dis_dx 0000:20:00.0: irq 113 for MSI/MSI-X [ 14.558356] (_dx_request_interrupt:443):test intr attempt 1 for inst 0 [ 15.556106] dis_dx: driver registered and configured successfully [ 15.646770] Dolphin Driver : dis_irm.conf: Setting link watchdog period to 10 seconds [ 15.647245] Dolphin Driver : dis_irm.conf: Enabling resource outtage notes [ 15.647509] Dolphin Driver : dis_irm.conf: Setting driver page size to 1048576 bytes [ 15.647975] Dolphin Driver : Page Size is 1024K bytes [ 15.648234] Dolphin Driver : dis_irm.conf: Maximum segment size limited to 4 Megabytes [ 15.648705] Dolphin Driver : dis_irm.conf: Session probing disabled while heartbeat is ok [ 15.649174] Dolphin Driver : dis_irm.conf: IOMMU usage disabled [ 15.649438] Dolphin Driver : MTRR not used [ 15.649908] Dolphin Driver : 1 supported DXH adapter(s) found on the system [ 15.650167] Dolphin Driver : Found write combining in PAT1 [ 15.650422] Dolphin Driver : version Dolphin IRM (DX) 4.2.4 October 10th 2012 (rev 31563) initializing [ 15.650886] Dolphin Driver : 64 bit mode Compiled Jun 21 2013 : 18:55:29 [ 15.651158] Dolphin Driver : Requested to try to preallocate 160 MB memory [ 15.651416] Dolphin Driver : Somebody tried to allocate a too large segment (167772160 bytes) [ 15.651886] Dolphin Driver : Size limited to 4 Mbytes [ 15.652144] Dolphin Driver : Specified in dis_irm.conf [ 15.670366] DXH Adapter: Succeded in preallocating 160 MB memory in 40 subpools [ 15.670834] Dolphin Driver : =========================================================================== [ 15.671311] Dolphin Driver : Merge pools [ 15.671565] Dolphin Driver : =========================================================================== [ 15.672046] Dolphin Driver : Allocated 167772160 bytes,(160MB,163840KB) in 1 pools (Max = 167772160,160MB,163840KB) [ 15.672522] Dolphin Driver : Allocated 0 bytes,(0MB,0KB) in 0 pools (Max = 0,0MB,0KB) [ 15.672994] Dolphin Driver : (0 blocks Max = 0 blocks) [ 15.673257] Dolphin Driver : Pool 40 - size=167772160 - free=167772160 - block size=0 (160MB,163840KB) [ 15.673734] Dolphin Driver : Pool 40 - Virtual - start=[0xffff88006f800000] - end=[0xffff8800797fffff] [ 15.674211] Dolphin Driver : Pool 40 - Physical - start=[0x6f800000] - end=[0x797fffff] [ 15.674681] Dolphin Driver : Pool 40 - Base - start=[0xffff88006f800000] - end=[0xffff88006fbfffff] [ 15.675161] virtadap_init_pre: disable_automatic_rebuild = 0, task = 0xffff88085d4dbf80 [ 15.675637] DXH Instance 0 : Adapter configuration failed - not initialized [ 15.675979] DXH Instance 0 : Please run the dxconfig utility to initiate the adapter config information (Serial number is 0xad014513014) [ 15.676465] Dolphin Driver : successfully registered. Major number = 248 [ 15.681816] igb 0000:2b:00.1: changing MTU from 1500 to 9000 [ 15.799763] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 15.832679] Open-MX 1.5.3 initializing... [ 15.832947] Open-MX: attaching interfaces listed in 'eth1'... [ 15.833211] Open-MX: Attaching Ethernet interface 'eth1' as #0, MTU=9000 [ 15.833474] Open-MX: Interface 'eth1' is PCI device '0000:2b:00.1' managed by driver 'igb' [ 15.833956] Open-MX: attached 1 interfaces [ 15.834279] Open-MX initialized [ 16.196803] eth0: no IPv6 routers present [ 19.211319] igb: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 19.212633] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 26.934845] DXH Adapter 100 : Configured DXH Adapter to nodeId=4 (dxNodeId=0) [ 26.936155] DXH Adapter 0 : Driver attaching device 0 - instance 0 [ 26.936421] DXH Adapter 0 : Local adapter type: DXH510 [ 26.941849] DXH Adapter 0 : DX adapter chip version: 2 [ 26.942111] DXH Adapter 0 : Firmware version: 0x189 [ 26.942442] DXH Adapter 0 : SROM version: 0x1a1 [ 26.942703] DXH Adapter 0 : Assembly part revision: 0x1b1 [ 26.942963] DXH Adapter 0 : PCIe link width: x8 [ 26.943222] DXH Adapter 0 : _configGetTopology - Topology 'Switch' - Returning TOPOLOGY_SWITCH as default [ 26.943686] DXH Adapter 0 : NodeId is 4 - Serial no : 0xad014513014 [ 26.944812] DXH Adapter 0 : Enable DX port 0 [ 26.945072] DXH Adapter 0 : Enable DX port 1 [ 26.945330] Dolphin Driver : Using copy function sciMemCopy_No_FPU() [ 29.267218] eth1: no IPv6 routers present [ 39.118716] depscan.sh used greatest stack depth: 3776 bytes left [ 39.270848] Spectracom GPS card on bus 1e; device 0 [ 39.271131] pci 0000:1e:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 39.271395] TSYNC PIC BASE 0 address = f9600000 [ 39.271682] Remapped 0xffffc90013fb2000 [ 44.294436] TSYNC receiving YEAR info [ 44.294698] date = 328 days 5:29:1327382998 [ 44.294958] bcd time = 1327382998 sec 310 milliseconds 49 microseconds 310046230 nanosec [ 44.295429] Board sync = 1 [ 44.305668] TSYNC receiving YEAR info [ 44.305931] date = 28 days 5:29:1327382998 [ 44.306192] bcd time = 1327382998 sec 321 milliseconds 303 microseconds 321300510 nanosec [ 44.306669] Board sync = 1 [ 54.629347] k1ioptest0: startup time is 1327383008 [ 54.629349] k1ioptest0: cpu clock 2799715 [ 54.629351] k1ioptest0: EPICSM at 0x2d16f000 [ 54.629562] k1ioptest0: IPC at 0x144c1000 [ 54.629563] k1ioptest0: IOMEM at 0x144c5000 size 0x33410 [ 54.629565] k1ioptest0: DAQSM at 0x15169000 [ 54.629566] k1ioptest0: configured to use 2 cards [ 54.629566] k1ioptest0: Initializing PCI Modules [ 54.629573] k1ioptest0: ADC card on bus b; device 4 prim b [ 54.629574] k1ioptest0: adc card on bus b; device 4 prim b [ 54.629594] pci 0000:0b:04.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 54.632434] k1ioptest0: pci0 = 0xf9301000 [ 54.632457] k1ioptest0: pci2 = 0xf9300000 [ 54.632461] k1ioptest0: ADC I/O address=0xf9300000 0xffffc90013fbc000 [ 54.632464] k1ioptest0: BCR = 0x84060 [ 54.632476] k1ioptest0: RAG = 0x117d8 [ 54.632479] k1ioptest0: BCR = 0x84260 [ 55.060063] k1ioptest0: SSC = 0x16 [ 55.060066] k1ioptest0: IDBC = 0x1f [ 55.060078] k1ioptest0: ADC card on bus 1a; device 4 prim 1a [ 55.060102] k1ioptest0: Contec 1616 DIO card on bus 15; device 0 [ 55.060112] pci 0000:15:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 55.062951] k1ioptest0: contec 1616 dio pci2 = 0xe001 [ 55.062952] k1ioptest0: contec 1616 diospace = 0xe000 [ 55.062955] k1ioptest0: contec dio pci2 card number= 0x0 [ 55.062967] k1ioptest0: TSYNC GPS card on bus 1e; device 0 [ 55.062971] k1ioptest0: TSYNC PIC BASE 0 address = f9600000 [ 55.062981] k1ioptest0: Remapped 0xffffc90013fbe000 [ 60.082640] k1ioptest0: TSYNC receiving YEAR info [ 60.082644] k1ioptest0: date = 28 days 5:30:1327383014 [ 60.082645] k1ioptest0: bcd time = 1327383014 sec 128 milliseconds 501 microseconds 128497110 nanosec [ 60.082646] k1ioptest0: Board sync = 1 [ 60.092632] k1ioptest0: TSYNC receiving YEAR info [ 60.092635] k1ioptest0: date = 28 days 5:30:1327383014 [ 60.092636] k1ioptest0: bcd time = 1327383014 sec 138 milliseconds 512 microseconds 138507790 nanosec [ 60.092637] k1ioptest0: Board sync = 1 [ 60.092638] k1ioptest0: 3 PCI cards found [ 60.092639] k1ioptest0: *************************************************************************** [ 60.092640] k1ioptest0: 1 ADC cards found [ 60.092641] k1ioptest0: ADC 0 is a GSC_16AI64SSA module [ 60.092642] k1ioptest0: Channels = 64 [ 60.092642] k1ioptest0: Firmware Rev = 1 [ 60.092643] [ 60.092644] k1ioptest0: *************************************************************************** [ 60.092645] k1ioptest0: 0 DAC cards found [ 60.092646] k1ioptest0: *************************************************************************** [ 60.092647] k1ioptest0: 0 DIO cards found [ 60.092648] k1ioptest0: *************************************************************************** [ 60.092649] k1ioptest0: 0 IIRO-8 Isolated DIO cards found [ 60.092650] k1ioptest0: *************************************************************************** [ 60.092651] k1ioptest0: 0 IIRO-16 Isolated DIO cards found [ 60.092652] k1ioptest0: *************************************************************************** [ 60.092653] k1ioptest0: 0 Contec 32ch PCIe DO cards found [ 60.092654] k1ioptest0: 1 Contec PCIe DIO1616 cards found [ 60.092655] k1ioptest0: 0 Contec PCIe DIO6464 cards found [ 60.092656] k1ioptest0: 1 DO cards found [ 60.092657] k1ioptest0: TDS controller 0 is at 0 [ 60.092658] k1ioptest0: Total of 2 I/O modules found and mapped [ 60.092659] k1ioptest0: *************************************************************************** [ 60.092660] k1ioptest0: 0 RFM cards found [ 60.092661] k1ioptest0: *************************************************************************** [ 60.092662] k1ioptest0: IRIG-B card found 2 [ 60.092663] k1ioptest0: *************************************************************************** [ 60.092664] k1ioptest0: Initializing space for daqLib buffers [ 60.193973] CPU 1 is now offline [ 60.194015] k1ioptest0: Sync source = 4 [ 60.194016] k1ioptest0: Waiting for EPICS BURT Restore = 1 [ 60.253888] k1ioptest0: Waiting for EPICS BURT 0 [ 60.253889] k1ioptest0: BURT Restore Complete [ 60.253892] k1ioptest0: Initialized servo control parameters. [ 60.254891] k1ioptest0: DAQ Ex Min/Max = 1 3 [ 60.254892] k1ioptest0: DAQ XEx Min/Max = 3 53 [ 60.254893] k1ioptest0: DAQ Tp Min/Max = 10001 10007 [ 60.254893] k1ioptest0: DAQ XTp Min/Max = 10007 10507 [ 60.254902] k1ioptest0: Have 118 CDS epics integer and 0 USR epics integer channels [ 60.254903] k1ioptest0: DAQ EPICS INT DATA is at 0xffffc9002d170028 with size 472 [ 60.254905] k1ioptest0: DAQ EPICS FLT DATA is at 0xffffc9002d170200 [ 60.254906] k1ioptest0: DAQ EPICS: Int = 118 Flt = 33 Filters = 22 Total = 173 Fast = 0 [ 60.254907] k1ioptest0: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [ 60.254908] k1ioptest0: crc length epics = 692 [ 60.254909] k1ioptest0: xfer sizes = 4096 0 692 692 [ 60.254911] k1ioptest0: Calling feCode() to initialize [ 60.254912] k1ioptest0: ADC setup complete [ 60.254913] k1ioptest0: DAC setup complete [ 60.254916] k1ioptest0: writing BIO 0 [ 60.334753] k1ioptest0: Triggered the ADC [ 61.079110] mx_stream[1659]: segfault at 7fffffeee000 ip 00000000004021f5 sp 00007fffffeaae90 error 4 in mx_stream.rcg-3.1.1[400000+4000] [ 70.935842] k1prequa: startup time is 1327383025 [ 70.935844] k1prequa: cpu clock 2799715 [ 70.935845] k1prequa: EPICSM at 0x1916a000 [ 70.935846] k1prequa: IPC at 0x144c1000 [ 70.935847] k1prequa: IOMEM at 0x144c5000 size 0x33410 [ 70.939411] k1prequa: DAQSM at 0x1d16b000 [ 70.939412] k1prequa: configured to use 1 cards [ 70.939413] k1prequa: Initializing PCI Modules [ 70.939414] k1prequa: 3 PCI cards found [ 70.939415] k1prequa: Found ADC at 0 0 [ 70.939416] k1prequa: 1 PCI cards found [ 70.939417] k1prequa: *************************************************************************** [ 70.939418] k1prequa: 1 ADC cards found [ 70.939419] k1prequa: ADC 0 is a GSC_16AI64SSA module [ 70.939420] k1prequa: Channels = 64 [ 70.939420] k1prequa: Firmware Rev = 0 [ 70.939421] [ 70.939421] k1prequa: *************************************************************************** [ 70.939423] k1prequa: 0 DAC cards found [ 70.939423] k1prequa: *************************************************************************** [ 70.939425] k1prequa: 0 DIO cards found [ 70.939425] k1prequa: *************************************************************************** [ 70.939427] k1prequa: 0 IIRO-8 Isolated DIO cards found [ 70.939427] k1prequa: *************************************************************************** [ 70.939429] k1prequa: 0 IIRO-16 Isolated DIO cards found [ 70.939430] k1prequa: *************************************************************************** [ 70.939431] k1prequa: 0 Contec 32ch PCIe DO cards found [ 70.939432] k1prequa: 0 Contec PCIe DIO1616 cards found [ 70.939432] k1prequa: 0 Contec PCIe DIO6464 cards found [ 70.939433] k1prequa: 0 DO cards found [ 70.939434] k1prequa: *************************************************************************** [ 70.939435] k1prequa: 0 RFM cards found [ 70.939436] k1prequa: *************************************************************************** [ 70.939437] k1prequa: Initializing space for daqLib buffers [ 70.939438] k1prequa: Epics burt restore is 0 [ 71.937703] k1prequa: Epics burt restore is 0 [ 72.936748] k1prequa: Epics burt restore is 0 [ 73.935799] k1prequa: Epics burt restore is 0 [ 74.934836] k1prequa: Epics burt restore is 0 [ 75.933881] k1prequa: Epics burt restore is 0 [ 77.035013] CPU 2 is now offline [ 77.035068] k1prequa: Sync source = 8 [ 77.035070] k1prequa: Waiting for EPICS BURT Restore = 1 [ 77.094942] k1prequa: Waiting for EPICS BURT 0 [ 77.094943] k1prequa: BURT Restore Complete [ 77.094946] k1prequa: Initialized servo control parameters. [ 77.095946] k1prequa: DAQ Ex Min/Max = 20001 20003 [ 77.095946] k1prequa: DAQ XEx Min/Max = 20003 20053 [ 77.095947] k1prequa: DAQ Tp Min/Max = 30001 30007 [ 77.095948] k1prequa: DAQ XTp Min/Max = 30007 30507 [ 77.095961] k1prequa: Have 115 CDS epics integer and 0 USR epics integer channels [ 77.095962] k1prequa: Have int mem hole after CDS 460 0 [ 77.095963] k1prequa: DAQ EPICS INT DATA is at 0xffffc9001916b028 with size 460 [ 77.095964] k1prequa: DAQ EPICS FLT DATA is at 0xffffc9001916b1f8 [ 77.095966] k1prequa: DAQ EPICS: Int = 115 Flt = 9885 Filters = 401 Total = 10401 Fast = 0 [ 77.095967] k1prequa: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [ 77.095968] k1prequa: crc length epics = 41604 [ 77.095970] k1prequa: xfer sizes = 128 325 41604 41604 [ 77.095971] k1prequa: Calling feCode() to initialize [ 77.095973] k1prequa: waiting to sync 11392 [ 77.919977] k1prequa: Synched 825910 [ 89.140067] k1grdconfig: startup time is 1327383043 [ 89.140069] k1grdconfig: cpu clock 2799715 [ 89.140071] k1grdconfig: EPICSM at 0x2116c000 [ 89.140072] k1grdconfig: IPC at 0x144c1000 [ 89.140073] k1grdconfig: IOMEM at 0x144c5000 size 0x33410 [ 89.143577] k1grdconfig: DAQSM at 0x2516d000 [ 89.143578] k1grdconfig: configured to use 1 cards [ 89.143579] k1grdconfig: Initializing PCI Modules [ 89.143580] k1grdconfig: 3 PCI cards found [ 89.143581] k1grdconfig: Found ADC at 0 0 [ 89.143581] k1grdconfig: 1 PCI cards found [ 89.143582] k1grdconfig: *************************************************************************** [ 89.143584] k1grdconfig: 1 ADC cards found [ 89.143585] k1grdconfig: ADC 0 is a GSC_16AI64SSA module [ 89.143585] k1grdconfig: Channels = 64 [ 89.143586] k1grdconfig: Firmware Rev = 0 [ 89.143587] [ 89.143587] k1grdconfig: *************************************************************************** [ 89.143589] k1grdconfig: 0 DAC cards found [ 89.143589] k1grdconfig: *************************************************************************** [ 89.143591] k1grdconfig: 0 DIO cards found [ 89.143592] k1grdconfig: *************************************************************************** [ 89.143593] k1grdconfig: 0 IIRO-8 Isolated DIO cards found [ 89.143594] k1grdconfig: *************************************************************************** [ 89.143595] k1grdconfig: 0 IIRO-16 Isolated DIO cards found [ 89.143596] k1grdconfig: *************************************************************************** [ 89.143597] k1grdconfig: 0 Contec 32ch PCIe DO cards found [ 89.143598] k1grdconfig: 0 Contec PCIe DIO1616 cards found [ 89.143599] k1grdconfig: 0 Contec PCIe DIO6464 cards found [ 89.143600] k1grdconfig: 0 DO cards found [ 89.143601] k1grdconfig: *************************************************************************** [ 89.143602] k1grdconfig: 0 RFM cards found [ 89.143603] k1grdconfig: *************************************************************************** [ 89.143604] k1grdconfig: Initializing space for daqLib buffers [ 89.143605] k1grdconfig: Epics burt restore is 0 [ 90.142073] k1grdconfig: Epics burt restore is 0 [ 91.243223] CPU 3 is now offline [ 91.243273] k1grdconfig: Sync source = 8 [ 91.243274] k1grdconfig: Waiting for EPICS BURT Restore = 1 [ 91.303148] k1grdconfig: Waiting for EPICS BURT 0 [ 91.303149] k1grdconfig: BURT Restore Complete [ 91.303178] k1grdconfig: Initialized servo control parameters. [ 91.304177] k1grdconfig: DAQ Ex Min/Max = 20001 20033 [ 91.304178] k1grdconfig: DAQ XEx Min/Max = 20033 20083 [ 91.304179] k1grdconfig: DAQ Tp Min/Max = 30001 30097 [ 91.304180] k1grdconfig: DAQ XTp Min/Max = 30097 30597 [ 91.304193] k1grdconfig: Have 115 CDS epics integer and 56 USR epics integer channels [ 91.304194] k1grdconfig: Have int mem hole after CDS 460 224 [ 91.304195] k1grdconfig: Have mem holes after CDS 460 224 [ 91.304196] Need to cpy ints twice - size 1 = 460 size 2 = 224 [ 91.304197] k1grdconfig: DAQ EPICS INT DATA is at 0xffffc9002116d028 with size 684 [ 91.304199] k1grdconfig: DAQ EPICS FLT DATA is at 0xffffc9002116d2d8 [ 91.304200] k1grdconfig: DAQ EPICS: Int = 171 Flt = 2144 Filters = 352 Total = 2667 Fast = 0 [ 91.304202] k1grdconfig: DAQ EPICS: Number of Filter Module Xfers = 3 last = 32 [ 91.304203] k1grdconfig: crc length epics = 10668 [ 91.304204] k1grdconfig: xfer sizes = 128 83 10668 10668 [ 91.304206] k1grdconfig: Calling feCode() to initialize [ 91.304207] k1grdconfig: waiting to sync 26816 [ 91.893208] k1grdconfig: Synched 590361 [ 102.333685] k1detdq0: startup time is 1327383056 [ 102.333686] k1detdq0: cpu clock 2799715 [ 102.333687] k1detdq0: EPICSM at 0x31170000 [ 102.333688] k1detdq0: IPC at 0x144c1000 [ 102.333689] k1detdq0: IOMEM at 0x144c5000 size 0x33410 [ 102.337119] k1detdq0: DAQSM at 0x35171000 [ 102.337120] k1detdq0: configured to use 1 cards [ 102.337121] k1detdq0: Initializing PCI Modules [ 102.337122] k1detdq0: 3 PCI cards found [ 102.337123] k1detdq0: Found ADC at 0 0 [ 102.337124] k1detdq0: 1 PCI cards found [ 102.337125] k1detdq0: *************************************************************************** [ 102.337126] k1detdq0: 1 ADC cards found [ 102.337127] k1detdq0: ADC 0 is a GSC_16AI64SSA module [ 102.337127] k1detdq0: Channels = 64 [ 102.337128] k1detdq0: Firmware Rev = 0 [ 102.337129] [ 102.337129] k1detdq0: *************************************************************************** [ 102.337130] k1detdq0: 0 DAC cards found [ 102.337131] k1detdq0: *************************************************************************** [ 102.337132] k1detdq0: 0 DIO cards found [ 102.337133] k1detdq0: *************************************************************************** [ 102.337134] k1detdq0: 0 IIRO-8 Isolated DIO cards found [ 102.337135] k1detdq0: *************************************************************************** [ 102.337137] k1detdq0: 0 IIRO-16 Isolated DIO cards found [ 102.337137] k1detdq0: *************************************************************************** [ 102.337139] k1detdq0: 0 Contec 32ch PCIe DO cards found [ 102.337139] k1detdq0: 0 Contec PCIe DIO1616 cards found [ 102.337140] k1detdq0: 0 Contec PCIe DIO6464 cards found [ 102.337141] k1detdq0: 0 DO cards found [ 102.337142] k1detdq0: *************************************************************************** [ 102.337143] k1detdq0: 0 RFM cards found [ 102.337144] k1detdq0: *************************************************************************** [ 102.337145] k1detdq0: Initializing space for daqLib buffers [ 102.337146] k1detdq0: Epics burt restore is 0 [ 103.335250] k1detdq0: Epics burt restore is 0 [ 104.436522] CPU 4 is now offline [ 104.436582] k1detdq0: Sync source = 8 [ 104.436584] k1detdq0: Waiting for EPICS BURT Restore = 1 [ 104.496456] k1detdq0: Waiting for EPICS BURT 0 [ 104.496457] k1detdq0: BURT Restore Complete [ 104.496460] k1detdq0: Initialized servo control parameters. [ 104.497460] k1detdq0: DAQ Ex Min/Max = 20001 20003 [ 104.497461] k1detdq0: DAQ XEx Min/Max = 20003 20053 [ 104.497462] k1detdq0: DAQ Tp Min/Max = 30001 30007 [ 104.497463] k1detdq0: DAQ XTp Min/Max = 30007 30507 [ 104.497476] k1detdq0: Have 115 CDS epics integer and 2 USR epics integer channels [ 104.497478] k1detdq0: Have int mem hole after CDS 460 8 [ 104.497479] k1detdq0: Have mem holes after CDS 460 8 [ 104.497480] Need to cpy ints twice - size 1 = 460 size 2 = 8 [ 104.497481] k1detdq0: DAQ EPICS INT DATA is at 0xffffc90031171028 with size 468 [ 104.497482] k1detdq0: DAQ EPICS FLT DATA is at 0xffffc90031171200 [ 104.497483] k1detdq0: DAQ EPICS: Int = 117 Flt = 4 Filters = 22 Total = 143 Fast = 0 [ 104.497485] k1detdq0: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [ 104.497486] k1detdq0: crc length epics = 572 [ 104.497487] k1detdq0: xfer sizes = 128 4 572 572 [ 104.497489] k1detdq0: Calling feCode() to initialize [ 104.497490] k1detdq0: waiting to sync 41152 [ 104.868348] k1detdq0: Synched 371713 [ 115.645642] k1opssim: startup time is 1327383069 [ 115.645644] k1opssim: cpu clock 2799715 [ 115.645645] k1opssim: EPICSM at 0x39172000 [ 115.645646] k1opssim: IPC at 0x144c1000 [ 115.645647] k1opssim: IOMEM at 0x144c5000 size 0x33410 [ 115.649058] k1opssim: DAQSM at 0x3d173000 [ 115.649059] k1opssim: configured to use 1 cards [ 115.649060] k1opssim: Initializing PCI Modules [ 115.649060] k1opssim: 3 PCI cards found [ 115.649061] k1opssim: Found ADC at 0 0 [ 115.649062] k1opssim: 1 PCI cards found [ 115.649063] k1opssim: *************************************************************************** [ 115.649064] k1opssim: 1 ADC cards found [ 115.649065] k1opssim: ADC 0 is a GSC_16AI64SSA module [ 115.649066] k1opssim: Channels = 64 [ 115.649067] k1opssim: Firmware Rev = 0 [ 115.649067] [ 115.649068] k1opssim: *************************************************************************** [ 115.649069] k1opssim: 0 DAC cards found [ 115.649070] k1opssim: *************************************************************************** [ 115.649071] k1opssim: 0 DIO cards found [ 115.649072] k1opssim: *************************************************************************** [ 115.649073] k1opssim: 0 IIRO-8 Isolated DIO cards found [ 115.649074] k1opssim: *************************************************************************** [ 115.649075] k1opssim: 0 IIRO-16 Isolated DIO cards found [ 115.649076] k1opssim: *************************************************************************** [ 115.649077] k1opssim: 0 Contec 32ch PCIe DO cards found [ 115.649078] k1opssim: 0 Contec PCIe DIO1616 cards found [ 115.649079] k1opssim: 0 Contec PCIe DIO6464 cards found [ 115.649080] k1opssim: 0 DO cards found [ 115.649081] k1opssim: *************************************************************************** [ 115.649082] k1opssim: 0 RFM cards found [ 115.649083] k1opssim: *************************************************************************** [ 115.649084] k1opssim: Initializing space for daqLib buffers [ 115.649085] k1opssim: Epics burt restore is 0 [ 116.647194] k1opssim: Epics burt restore is 0 [ 117.748312] CPU 9 is now offline [ 117.748376] k1opssim: Sync source = 8 [ 117.748378] k1opssim: Waiting for EPICS BURT Restore = 1 [ 117.808250] k1opssim: Waiting for EPICS BURT 0 [ 117.808251] k1opssim: BURT Restore Complete [ 117.808263] k1opssim: Initialized servo control parameters. [ 117.809262] k1opssim: DAQ Ex Min/Max = 1 11 [ 117.809263] k1opssim: DAQ XEx Min/Max = 11 61 [ 117.809264] k1opssim: DAQ Tp Min/Max = 10001 10031 [ 117.809264] k1opssim: DAQ XTp Min/Max = 10031 10531 [ 117.809277] k1opssim: Have 115 CDS epics integer and 7 USR epics integer channels [ 117.809279] k1opssim: Have int mem hole after CDS 460 28 [ 117.809280] k1opssim: Have int mem hole after user 460 28 [ 117.809281] k1opssim: Have mem holes after CDS 460 28 [ 117.809282] Need to cpy ints twice - size 1 = 460 size 2 = 28 [ 117.809283] k1opssim: DAQ EPICS INT DATA is at 0xffffc90039173028 with size 488 [ 117.809284] k1opssim: DAQ EPICS FLT DATA is at 0xffffc90039173218 [ 117.809286] k1opssim: DAQ EPICS: Int = 122 Flt = 63 Filters = 110 Total = 295 Fast = 6 [ 117.809287] k1opssim: DAQ EPICS: Number of Filter Module Xfers = 3 last = 10 [ 117.809288] k1opssim: crc length epics = 1180 [ 117.809289] k1opssim: Found double 8 [ 117.809290] k1opssim: xfer sizes = 1024 29 29852 29852 [ 117.809292] k1opssim: Calling feCode() to initialize [ 117.809297] k1opssim: waiting to sync 63232 [ 117.843487] k1opssim: Synched 34267 [ 128.886063] k1sdfmanage: startup time is 1327383083 [ 128.886065] k1sdfmanage: cpu clock 2799715 [ 128.886066] k1sdfmanage: EPICSM at 0x41174000 [ 128.886067] k1sdfmanage: IPC at 0x144c1000 [ 128.886068] k1sdfmanage: IOMEM at 0x144c5000 size 0x33410 [ 128.889519] k1sdfmanage: DAQSM at 0x45175000 [ 128.889520] k1sdfmanage: configured to use 1 cards [ 128.889521] k1sdfmanage: Initializing PCI Modules [ 128.889522] k1sdfmanage: 3 PCI cards found [ 128.889523] k1sdfmanage: Found ADC at 0 0 [ 128.889524] k1sdfmanage: 1 PCI cards found [ 128.889525] k1sdfmanage: *************************************************************************** [ 128.889526] k1sdfmanage: 1 ADC cards found [ 128.889527] k1sdfmanage: ADC 0 is a GSC_16AI64SSA module [ 128.889528] k1sdfmanage: Channels = 64 [ 128.889529] k1sdfmanage: Firmware Rev = 0 [ 128.889529] [ 128.889530] k1sdfmanage: *************************************************************************** [ 128.889531] k1sdfmanage: 0 DAC cards found [ 128.889532] k1sdfmanage: *************************************************************************** [ 128.889533] k1sdfmanage: 0 DIO cards found [ 128.889534] k1sdfmanage: *************************************************************************** [ 128.889535] k1sdfmanage: 0 IIRO-8 Isolated DIO cards found [ 128.889536] k1sdfmanage: *************************************************************************** [ 128.889538] k1sdfmanage: 0 IIRO-16 Isolated DIO cards found [ 128.889538] k1sdfmanage: *************************************************************************** [ 128.889540] k1sdfmanage: 0 Contec 32ch PCIe DO cards found [ 128.889541] k1sdfmanage: 0 Contec PCIe DIO1616 cards found [ 128.889541] k1sdfmanage: 0 Contec PCIe DIO6464 cards found [ 128.889542] k1sdfmanage: 0 DO cards found [ 128.889543] k1sdfmanage: *************************************************************************** [ 128.889544] k1sdfmanage: 0 RFM cards found [ 128.889545] k1sdfmanage: *************************************************************************** [ 128.889546] k1sdfmanage: Initializing space for daqLib buffers [ 128.889548] k1sdfmanage: Epics burt restore is 0 [ 129.888275] k1sdfmanage: Epics burt restore is 0 [ 130.989386] CPU 5 is now offline [ 130.989453] k1sdfmanage: Sync source = 8 [ 130.989455] k1sdfmanage: Waiting for EPICS BURT Restore = 1 [ 131.049327] k1sdfmanage: Waiting for EPICS BURT 0 [ 131.049328] k1sdfmanage: BURT Restore Complete [ 131.049331] k1sdfmanage: Initialized servo control parameters. [ 131.050331] k1sdfmanage: DAQ Ex Min/Max = 20001 20003 [ 131.050331] k1sdfmanage: DAQ XEx Min/Max = 20003 20053 [ 131.050332] k1sdfmanage: DAQ Tp Min/Max = 30001 30007 [ 131.050333] k1sdfmanage: DAQ XTp Min/Max = 30007 30507 [ 131.050347] k1sdfmanage: Have 115 CDS epics integer and 0 USR epics integer channels [ 131.050348] k1sdfmanage: Have int mem hole after CDS 460 0 [ 131.050350] k1sdfmanage: DAQ EPICS INT DATA is at 0xffffc90041175028 with size 460 [ 131.050351] k1sdfmanage: DAQ EPICS FLT DATA is at 0xffffc900411751f8 [ 131.050352] k1sdfmanage: DAQ EPICS: Int = 115 Flt = 1293 Filters = 22 Total = 1430 Fast = 0 [ 131.050354] k1sdfmanage: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [ 131.050355] k1sdfmanage: crc length epics = 5720 [ 131.050356] k1sdfmanage: xfer sizes = 128 44 5720 5720 [ 131.050357] k1sdfmanage: Calling feCode() to initialize [ 131.050359] k1sdfmanage: waiting to sync 15168 [ 131.816716] k1sdfmanage: Synched 768128