[ 0.000000] Initializing cgroup subsys cpuset [ 0.000000] Initializing cgroup subsys cpu [ 0.000000] Linux version 3.0.8 (controls@master) (gcc version 4.4.3 (Gentoo 4.4.3-r2 p1.2) ) #1 SMP Mon Jun 17 16:45:04 JST 2013 [ 0.000000] Command line: ip=dhcp root=/dev/nfs nfsroot=10.68.10.100:/diskless/root BOOT_IMAGE=kernel-3.0.8-cs [ 0.000000] BIOS-provided physical RAM map: [ 0.000000] BIOS-e820: 0000000000000000 - 000000000009ec00 (usable) [ 0.000000] BIOS-e820: 000000000009ec00 - 00000000000a0000 (reserved) [ 0.000000] BIOS-e820: 00000000000e0000 - 0000000000100000 (reserved) [ 0.000000] BIOS-e820: 0000000000100000 - 00000000790c3000 (usable) [ 0.000000] BIOS-e820: 00000000790c3000 - 00000000799f9000 (reserved) [ 0.000000] BIOS-e820: 00000000799f9000 - 0000000079eb7000 (ACPI NVS) [ 0.000000] BIOS-e820: 0000000079eb7000 - 0000000090000000 (reserved) [ 0.000000] BIOS-e820: 00000000fed1c000 - 00000000fed45000 (reserved) [ 0.000000] BIOS-e820: 00000000ff000000 - 0000000100000000 (reserved) [ 0.000000] BIOS-e820: 0000000100000000 - 0000000880000000 (usable) [ 0.000000] NX (Execute Disable) protection: active [ 0.000000] DMI 3.0 present. [ 0.000000] DMI: Supermicro SYS-6028R-WTR/X10DRW-i, BIOS 3.1 06/07/2018 [ 0.000000] e820 update range: 0000000000000000 - 0000000000010000 (usable) ==> (reserved) [ 0.000000] e820 remove range: 00000000000a0000 - 0000000000100000 (usable) [ 0.000000] No AGP bridge found [ 0.000000] last_pfn = 0x880000 max_arch_pfn = 0x400000000 [ 0.000000] MTRR default type: write-back [ 0.000000] MTRR fixed ranges enabled: [ 0.000000] 00000-9FFFF write-back [ 0.000000] A0000-BFFFF uncachable [ 0.000000] C0000-FFFFF write-protect [ 0.000000] MTRR variable ranges enabled: [ 0.000000] 0 base 000080000000 mask 3FFF80000000 uncachable [ 0.000000] 1 base 380000000000 mask 3F8000000000 uncachable [ 0.000000] 2 disabled [ 0.000000] 3 disabled [ 0.000000] 4 disabled [ 0.000000] 5 disabled [ 0.000000] 6 disabled [ 0.000000] 7 disabled [ 0.000000] 8 disabled [ 0.000000] 9 disabled [ 0.000000] x86 PAT enabled: cpu 0, old 0x7040600070406, new 0x7010600070106 [ 0.000000] last_pfn = 0x790c3 max_arch_pfn = 0x400000000 [ 0.000000] found SMP MP-table at [ffff8800000fcf20] fcf20 [ 0.000000] initial memory mapped : 0 - 20000000 [ 0.000000] Base memory trampoline at [ffff880000099000] 99000 size 20480 [ 0.000000] Using GB pages for direct mapping [ 0.000000] init_memory_mapping: 0000000000000000-00000000790c3000 [ 0.000000] 0000000000 - 0040000000 page 1G [ 0.000000] 0040000000 - 0079000000 page 2M [ 0.000000] 0079000000 - 00790c3000 page 4k [ 0.000000] kernel direct mapping tables up to 790c3000 @ 1fffd000-20000000 [ 0.000000] init_memory_mapping: 0000000100000000-0000000880000000 [ 0.000000] 0100000000 - 0880000000 page 1G [ 0.000000] kernel direct mapping tables up to 880000000 @ 790c2000-790c3000 [ 0.000000] ACPI: RSDP 00000000000f05b0 00024 (v02 SUPERM) [ 0.000000] ACPI: XSDT 00000000799f9088 00094 (v01 01072009 AMI 00010013) [ 0.000000] ACPI: FACP 0000000079a2ad28 0010C (v05 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI Warning: FADT (revision 5) is longer than ACPI 2.0 version, truncating length 268 to 244 (20110413/tbfadt-288) [ 0.000000] ACPI: DSDT 00000000799f91b8 31B6C (v02 SUPERM SMCI--MB 01072009 INTL 20091013) [ 0.000000] ACPI: FACS 0000000079eb5f80 00040 [ 0.000000] ACPI: APIC 0000000079a2ae38 000D4 (v03 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: FPDT 0000000079a2af10 00044 (v01 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: FIDT 0000000079a2af58 0009C (v01 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: SPMI 0000000079a2aff8 00041 (v05 SUPERM SMCI--MB 00000000 AMI. 00000000) [ 0.000000] ACPI: MCFG 0000000079a2b040 0003C (v01 SUPERM SMCI--MB 01072009 MSFT 00000097) [ 0.000000] ACPI: UEFI 0000000079a2b080 00042 (v01 SUPERM SMCI--MB 01072009 00000000) [ 0.000000] ACPI: NFIT 0000000079a2b0c8 18028 (v01 00000000 00000000) [ 0.000000] ACPI: WDDT 0000000079a430f0 00040 (v01 SUPERM SMCI--MB 00000000 INTL 20091013) [ 0.000000] ACPI: SSDT 0000000079a43130 17141 (v02 SUPERM PmMgt 00000001 INTL 20120913) [ 0.000000] ACPI: NITR 0000000079a5a278 00071 (v02 SUPERM SMCI--MB 00000001 INTL 20091013) [ 0.000000] ACPI: SSDT 0000000079a5a2f0 0264C (v02 SUPERM SpsNm 00000002 INTL 20120913) [ 0.000000] ACPI: SSDT 0000000079a5c940 00064 (v02 SUPERM SpsNvs 00000002 INTL 20120913) [ 0.000000] ACPI: PRAD 0000000079a5c9a8 00102 (v02 SUPERM SMCI--MB 00000002 INTL 20120913) [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] No NUMA configuration found [ 0.000000] Faking a node at 0000000000000000-0000000880000000 [ 0.000000] Initmem setup node 0 0000000000000000-0000000880000000 [ 0.000000] NODE_DATA [000000087fffb000 - 000000087fffffff] [ 0.000000] [ffffea0000000000-ffffea001dbfffff] PMD -> [ffff88085f600000-ffff88087b5fffff] on node 0 [ 0.000000] Zone PFN ranges: [ 0.000000] DMA 0x00000010 -> 0x00001000 [ 0.000000] DMA32 0x00001000 -> 0x00100000 [ 0.000000] Normal 0x00100000 -> 0x00880000 [ 0.000000] Movable zone start PFN for each node [ 0.000000] early_node_map[3] active PFN ranges [ 0.000000] 0: 0x00000010 -> 0x0000009e [ 0.000000] 0: 0x00000100 -> 0x000790c3 [ 0.000000] 0: 0x00100000 -> 0x00880000 [ 0.000000] On node 0 totalpages: 8360017 [ 0.000000] DMA zone: 56 pages used for memmap [ 0.000000] DMA zone: 5 pages reserved [ 0.000000] DMA zone: 3921 pages, LIFO batch:0 [ 0.000000] DMA32 zone: 14280 pages used for memmap [ 0.000000] DMA32 zone: 477435 pages, LIFO batch:31 [ 0.000000] Normal zone: 107520 pages used for memmap [ 0.000000] Normal zone: 7756800 pages, LIFO batch:31 [ 0.000000] ACPI: PM-Timer IO Port: 0x408 [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] ACPI: LAPIC (acpi_id[0x00] lapic_id[0x00] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x02] lapic_id[0x02] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x04] lapic_id[0x04] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x06] lapic_id[0x06] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x10] lapic_id[0x10] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x12] lapic_id[0x12] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x14] lapic_id[0x14] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x16] lapic_id[0x16] enabled) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x00] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x02] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x04] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x06] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x10] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x12] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x14] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x16] high edge lint[0x1]) [ 0.000000] ACPI: IOAPIC (id[0x01] address[0xfec00000] gsi_base[0]) [ 0.000000] IOAPIC[0]: apic_id 1, version 32, address 0xfec00000, GSI 0-23 [ 0.000000] ACPI: IOAPIC (id[0x02] address[0xfec01000] gsi_base[24]) [ 0.000000] IOAPIC[1]: apic_id 2, version 32, address 0xfec01000, GSI 24-47 [ 0.000000] ACPI: IOAPIC (id[0x03] address[0xfec40000] gsi_base[48]) [ 0.000000] IOAPIC[2]: apic_id 3, version 32, address 0xfec40000, GSI 48-71 [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 0 global_irq 2 dfl dfl) [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 9 global_irq 9 high level) [ 0.000000] ACPI: IRQ0 used by override. [ 0.000000] ACPI: IRQ2 used by override. [ 0.000000] ACPI: IRQ9 used by override. [ 0.000000] Using ACPI (MADT) for SMP configuration information [ 0.000000] SMP: Allowing 8 CPUs, 0 hotplug CPUs [ 0.000000] nr_irqs_gsi: 88 [ 0.000000] PM: Registered nosave memory: 000000000009e000 - 000000000009f000 [ 0.000000] PM: Registered nosave memory: 000000000009f000 - 00000000000a0000 [ 0.000000] PM: Registered nosave memory: 00000000000a0000 - 00000000000e0000 [ 0.000000] PM: Registered nosave memory: 00000000000e0000 - 0000000000100000 [ 0.000000] PM: Registered nosave memory: 00000000790c3000 - 00000000799f9000 [ 0.000000] PM: Registered nosave memory: 00000000799f9000 - 0000000079eb7000 [ 0.000000] PM: Registered nosave memory: 0000000079eb7000 - 0000000090000000 [ 0.000000] PM: Registered nosave memory: 0000000090000000 - 00000000fed1c000 [ 0.000000] PM: Registered nosave memory: 00000000fed1c000 - 00000000fed45000 [ 0.000000] PM: Registered nosave memory: 00000000fed45000 - 00000000ff000000 [ 0.000000] PM: Registered nosave memory: 00000000ff000000 - 0000000100000000 [ 0.000000] Allocating PCI resources starting at 90000000 (gap: 90000000:6ed1c000) [ 0.000000] setup_percpu: NR_CPUS:64 nr_cpumask_bits:64 nr_cpu_ids:8 nr_node_ids:1 [ 0.000000] PERCPU: Embedded 25 pages/cpu @ffff88087fc00000 s69824 r8192 d24384 u262144 [ 0.000000] pcpu-alloc: s69824 r8192 d24384 u262144 alloc=1*2097152 [ 0.000000] pcpu-alloc: [0] 0 1 2 3 4 5 6 7 [ 0.000000] Built 1 zonelists in Zone order, mobility grouping on. Total pages: 8238156 [ 0.000000] Policy zone: Normal [ 0.000000] Kernel command line: ip=dhcp root=/dev/nfs nfsroot=10.68.10.100:/diskless/root BOOT_IMAGE=kernel-3.0.8-cs [ 0.000000] PID hash table entries: 4096 (order: 3, 32768 bytes) [ 0.000000] xsave/xrstor: enabled xstate_bv 0x7, cntxt size 0x340 [ 0.000000] Checking aperture... [ 0.000000] No AGP bridge found [ 0.000000] Calgary: detecting Calgary via BIOS EBDA area [ 0.000000] Calgary: Unable to locate Rio Grande table in EBDA - bailing! [ 0.000000] Memory: 32902000k/35651584k available (5398k kernel code, 2211516k absent, 538068k reserved, 5343k data, 628k init) [ 0.000000] SLUB: Genslabs=15, HWalign=64, Order=0-3, MinObjects=0, CPUs=8, Nodes=1 [ 0.000000] Hierarchical RCU implementation. [ 0.000000] NR_IRQS:4352 nr_irqs:1560 16 [ 0.000000] Extended CMOS year: 2000 [ 0.000000] Console: colour VGA+ 80x25 [ 0.000000] console [tty0] enabled [ 0.001000] Fast TSC calibration using PIT [ 0.002000] Detected 3000.056 MHz processor. [ 0.000004] Calibrating delay loop (skipped), value calculated using timer frequency.. 6000.11 BogoMIPS (lpj=3000056) [ 0.000682] pid_max: default: 32768 minimum: 301 [ 0.002959] Dentry cache hash table entries: 4194304 (order: 13, 33554432 bytes) [ 0.011710] Inode-cache hash table entries: 2097152 (order: 12, 16777216 bytes) [ 0.015754] Mount-cache hash table entries: 256 [ 0.016235] Initializing cgroup subsys cpuacct [ 0.016579] Initializing cgroup subsys freezer [ 0.016929] CPU: Physical Processor ID: 0 [ 0.017261] CPU: Processor Core ID: 0 [ 0.017603] mce: CPU supports 22 MCE banks [ 0.017963] CPU0: Thermal monitoring enabled (TM1) [ 0.018380] ACPI: Core revision 20110413 [ 0.040028] ..TIMER: vector=0x30 apic1=0 pin1=2 apic2=-1 pin2=-1 [ 0.050359] CPU0: Intel(R) Xeon(R) CPU E5-2623 v3 @ 3.00GHz stepping 02 [ 0.152193] Performance Events: no PEBS fmt2+, generic architected perfmon, Intel PMU driver. [ 0.152982] ... version: 3 [ 0.153316] ... bit width: 48 [ 0.153648] ... generic registers: 8 [ 0.153981] ... value mask: 0000ffffffffffff [ 0.154317] ... max period: 000000007fffffff [ 0.154653] ... fixed-purpose events: 3 [ 0.154986] ... event mask: 00000007000000ff [ 0.155447] Booting Node 0, Processors #1 [ 0.155577] smpboot cpu 1: start_ip = 99000 [ 0.246285] #2 [ 0.246350] smpboot cpu 2: start_ip = 99000 [ 0.337158] #3 [ 0.337223] smpboot cpu 3: start_ip = 99000 [ 0.428030] #4 [ 0.428096] smpboot cpu 4: start_ip = 99000 [ 0.518979] #5 [ 0.519042] smpboot cpu 5: start_ip = 99000 [ 0.609835] #6 [ 0.609899] smpboot cpu 6: start_ip = 99000 [ 0.700697] #7 Ok. [ 0.701025] smpboot cpu 7: start_ip = 99000 [ 0.791559] Brought up 8 CPUs [ 0.791890] Total of 8 processors activated (47994.03 BogoMIPS). [ 0.797070] kworker/u:0 used greatest stack depth: 5760 bytes left [ 0.797222] PM: Registering ACPI NVS region at 799f9000 (4972544 bytes) [ 0.797501] Time: 2:22:01 Date: 09/24/21 [ 0.797541] NET: Registered protocol family 16 [ 0.798662] ACPI FADT declares the system doesn't support PCIe ASPM, so disable it [ 0.806884] ACPI: bus type pci registered [ 0.807309] PCI: MMCONFIG for domain 0000 [bus 00-ff] at [mem 0x80000000-0x8fffffff] (base 0x80000000) [ 0.807924] PCI: MMCONFIG at [mem 0x80000000-0x8fffffff] reserved in E820 [ 0.818831] PCI: Using configuration type 1 for base access [ 0.826403] bio: create slab at 0 [ 0.834196] ACPI: EC: Look up EC in DSDT [ 0.852771] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored [ 0.912463] ACPI: Interpreter enabled [ 0.912797] ACPI: (supports S0 S4 S5) [ 0.913317] ACPI: BIOS offers _GTS [ 0.913650] ACPI: If "acpi.gts=1" improves suspend, please notify linux-acpi@vger.kernel.org [ 0.914257] ACPI: Using IOAPIC for interrupt routing [ 0.939122] ACPI: No dock devices found. [ 0.939459] PCI: Using host bridge windows from ACPI; if necessary, use "pci=nocrs" and report a bug [ 1.938338] ACPI: PCI Root Bridge [UNC1] (domain 0000 [bus ff]) [ 1.938767] pci 0000:ff:08.0: [8086:2f80] type 0 class 0x000880 [ 1.938804] pci 0000:ff:08.2: [8086:2f32] type 0 class 0x001101 [ 1.938835] pci 0000:ff:08.3: [8086:2f83] type 0 class 0x000880 [ 1.938868] pci 0000:ff:09.0: [8086:2f90] type 0 class 0x000880 [ 1.938898] pci 0000:ff:09.2: [8086:2f33] type 0 class 0x001101 [ 1.938927] pci 0000:ff:09.3: [8086:2f93] type 0 class 0x000880 [ 1.938960] pci 0000:ff:0b.0: [8086:2f81] type 0 class 0x000880 [ 1.938988] pci 0000:ff:0b.1: [8086:2f36] type 0 class 0x001101 [ 1.939019] pci 0000:ff:0b.2: [8086:2f37] type 0 class 0x001101 [ 1.939050] pci 0000:ff:0c.0: [8086:2fe0] type 0 class 0x000880 [ 1.939079] pci 0000:ff:0c.1: [8086:2fe1] type 0 class 0x000880 [ 1.939106] pci 0000:ff:0c.2: [8086:2fe2] type 0 class 0x000880 [ 1.939135] pci 0000:ff:0c.3: [8086:2fe3] type 0 class 0x000880 [ 1.939166] pci 0000:ff:0f.0: [8086:2ff8] type 0 class 0x000880 [ 1.939194] pci 0000:ff:0f.1: [8086:2ff9] type 0 class 0x000880 [ 1.939223] pci 0000:ff:0f.4: [8086:2ffc] type 0 class 0x000880 [ 1.939253] pci 0000:ff:0f.5: [8086:2ffd] type 0 class 0x000880 [ 1.939282] pci 0000:ff:0f.6: [8086:2ffe] type 0 class 0x000880 [ 1.939313] pci 0000:ff:10.0: [8086:2f1d] type 0 class 0x000880 [ 1.939341] pci 0000:ff:10.1: [8086:2f34] type 0 class 0x001101 [ 1.939371] pci 0000:ff:10.5: [8086:2f1e] type 0 class 0x000880 [ 1.939398] pci 0000:ff:10.6: [8086:2f7d] type 0 class 0x001101 [ 1.939425] pci 0000:ff:10.7: [8086:2f1f] type 0 class 0x000880 [ 1.939452] pci 0000:ff:12.0: [8086:2fa0] type 0 class 0x000880 [ 1.939487] pci 0000:ff:12.1: [8086:2f30] type 0 class 0x001101 [ 1.939523] pci 0000:ff:13.0: [8086:2fa8] type 0 class 0x000880 [ 1.939556] pci 0000:ff:13.1: [8086:2f71] type 0 class 0x000880 [ 1.939588] pci 0000:ff:13.2: [8086:2faa] type 0 class 0x000880 [ 1.939621] pci 0000:ff:13.3: [8086:2fab] type 0 class 0x000880 [ 1.939653] pci 0000:ff:13.4: [8086:2fac] type 0 class 0x000880 [ 1.939686] pci 0000:ff:13.5: [8086:2fad] type 0 class 0x000880 [ 1.939718] pci 0000:ff:13.6: [8086:2fae] type 0 class 0x000880 [ 1.939751] pci 0000:ff:13.7: [8086:2faf] type 0 class 0x000880 [ 1.939782] pci 0000:ff:14.0: [8086:2fb0] type 0 class 0x000880 [ 1.939815] pci 0000:ff:14.1: [8086:2fb1] type 0 class 0x000880 [ 1.939847] pci 0000:ff:14.2: [8086:2fb2] type 0 class 0x000880 [ 1.939880] pci 0000:ff:14.3: [8086:2fb3] type 0 class 0x000880 [ 1.939912] pci 0000:ff:14.4: [8086:2fbc] type 0 class 0x000880 [ 1.939943] pci 0000:ff:14.5: [8086:2fbd] type 0 class 0x000880 [ 1.939973] pci 0000:ff:14.6: [8086:2fbe] type 0 class 0x000880 [ 1.940006] pci 0000:ff:14.7: [8086:2fbf] type 0 class 0x000880 [ 1.940038] pci 0000:ff:15.0: [8086:2fb4] type 0 class 0x000880 [ 1.940071] pci 0000:ff:15.1: [8086:2fb5] type 0 class 0x000880 [ 1.940103] pci 0000:ff:15.2: [8086:2fb6] type 0 class 0x000880 [ 1.940136] pci 0000:ff:15.3: [8086:2fb7] type 0 class 0x000880 [ 1.940171] pci 0000:ff:16.0: [8086:2f68] type 0 class 0x000880 [ 1.940204] pci 0000:ff:16.6: [8086:2f6e] type 0 class 0x000880 [ 1.940235] pci 0000:ff:16.7: [8086:2f6f] type 0 class 0x000880 [ 1.940268] pci 0000:ff:17.0: [8086:2fd0] type 0 class 0x000880 [ 1.940300] pci 0000:ff:17.4: [8086:2fb8] type 0 class 0x000880 [ 1.940332] pci 0000:ff:17.5: [8086:2fb9] type 0 class 0x000880 [ 1.940363] pci 0000:ff:17.6: [8086:2fba] type 0 class 0x000880 [ 1.940394] pci 0000:ff:17.7: [8086:2fbb] type 0 class 0x000880 [ 1.940430] pci 0000:ff:1e.0: [8086:2f98] type 0 class 0x000880 [ 1.940458] pci 0000:ff:1e.1: [8086:2f99] type 0 class 0x000880 [ 1.940487] pci 0000:ff:1e.2: [8086:2f9a] type 0 class 0x000880 [ 1.940518] pci 0000:ff:1e.3: [8086:2fc0] type 0 class 0x000880 [ 1.940526] pci 0000:ff:1e.3: reg 10: [mem 0x00000010-0x0000001f 64bit pref] [ 1.940548] pci 0000:ff:1e.4: [8086:2f9c] type 0 class 0x000880 [ 1.940580] pci 0000:ff:1f.0: [8086:2f88] type 0 class 0x000880 [ 1.940610] pci 0000:ff:1f.2: [8086:2f8a] type 0 class 0x000880 [ 1.940644] ACPI: PCI Interrupt Routing Table [\_SB_.UNC1._PRT] [ 1.942644] pci0000:ff: Requesting ACPI _OSC control (0x1d) [ 1.943875] pci0000:ff: ACPI _OSC control (0x15) granted [ 2.945231] ACPI: PCI Root Bridge [UNC0] (domain 0000 [bus 7f]) [ 2.945664] pci 0000:7f:08.0: [8086:2f80] type 0 class 0x000880 [ 2.945692] pci 0000:7f:08.2: [8086:2f32] type 0 class 0x001101 [ 2.945718] pci 0000:7f:08.3: [8086:2f83] type 0 class 0x000880 [ 2.945747] pci 0000:7f:09.0: [8086:2f90] type 0 class 0x000880 [ 2.945776] pci 0000:7f:09.2: [8086:2f33] type 0 class 0x001101 [ 2.945802] pci 0000:7f:09.3: [8086:2f93] type 0 class 0x000880 [ 2.945831] pci 0000:7f:0b.0: [8086:2f81] type 0 class 0x000880 [ 2.945855] pci 0000:7f:0b.1: [8086:2f36] type 0 class 0x001101 [ 2.945880] pci 0000:7f:0b.2: [8086:2f37] type 0 class 0x001101 [ 2.945906] pci 0000:7f:0c.0: [8086:2fe0] type 0 class 0x000880 [ 2.945930] pci 0000:7f:0c.1: [8086:2fe1] type 0 class 0x000880 [ 2.945954] pci 0000:7f:0c.2: [8086:2fe2] type 0 class 0x000880 [ 2.945980] pci 0000:7f:0c.3: [8086:2fe3] type 0 class 0x000880 [ 2.946006] pci 0000:7f:0f.0: [8086:2ff8] type 0 class 0x000880 [ 2.946030] pci 0000:7f:0f.1: [8086:2ff9] type 0 class 0x000880 [ 2.946054] pci 0000:7f:0f.4: [8086:2ffc] type 0 class 0x000880 [ 2.946079] pci 0000:7f:0f.5: [8086:2ffd] type 0 class 0x000880 [ 2.946103] pci 0000:7f:0f.6: [8086:2ffe] type 0 class 0x000880 [ 2.946128] pci 0000:7f:10.0: [8086:2f1d] type 0 class 0x000880 [ 2.946152] pci 0000:7f:10.1: [8086:2f34] type 0 class 0x001101 [ 2.946182] pci 0000:7f:10.5: [8086:2f1e] type 0 class 0x000880 [ 2.946206] pci 0000:7f:10.6: [8086:2f7d] type 0 class 0x001101 [ 2.946229] pci 0000:7f:10.7: [8086:2f1f] type 0 class 0x000880 [ 2.946252] pci 0000:7f:12.0: [8086:2fa0] type 0 class 0x000880 [ 2.946280] pci 0000:7f:12.1: [8086:2f30] type 0 class 0x001101 [ 2.946312] pci 0000:7f:13.0: [8086:2fa8] type 0 class 0x000880 [ 2.946340] pci 0000:7f:13.1: [8086:2f71] type 0 class 0x000880 [ 2.946368] pci 0000:7f:13.2: [8086:2faa] type 0 class 0x000880 [ 2.946397] pci 0000:7f:13.3: [8086:2fab] type 0 class 0x000880 [ 2.946425] pci 0000:7f:13.4: [8086:2fac] type 0 class 0x000880 [ 2.946453] pci 0000:7f:13.5: [8086:2fad] type 0 class 0x000880 [ 2.946481] pci 0000:7f:13.6: [8086:2fae] type 0 class 0x000880 [ 2.946507] pci 0000:7f:13.7: [8086:2faf] type 0 class 0x000880 [ 2.946533] pci 0000:7f:14.0: [8086:2fb0] type 0 class 0x000880 [ 2.946560] pci 0000:7f:14.1: [8086:2fb1] type 0 class 0x000880 [ 2.946587] pci 0000:7f:14.2: [8086:2fb2] type 0 class 0x000880 [ 2.946618] pci 0000:7f:14.3: [8086:2fb3] type 0 class 0x000880 [ 2.946646] pci 0000:7f:14.4: [8086:2fbc] type 0 class 0x000880 [ 2.946672] pci 0000:7f:14.5: [8086:2fbd] type 0 class 0x000880 [ 2.946699] pci 0000:7f:14.6: [8086:2fbe] type 0 class 0x000880 [ 2.946725] pci 0000:7f:14.7: [8086:2fbf] type 0 class 0x000880 [ 2.946752] pci 0000:7f:15.0: [8086:2fb4] type 0 class 0x000880 [ 2.946780] pci 0000:7f:15.1: [8086:2fb5] type 0 class 0x000880 [ 2.946808] pci 0000:7f:15.2: [8086:2fb6] type 0 class 0x000880 [ 2.946838] pci 0000:7f:15.3: [8086:2fb7] type 0 class 0x000880 [ 2.946869] pci 0000:7f:16.0: [8086:2f68] type 0 class 0x000880 [ 2.946896] pci 0000:7f:16.6: [8086:2f6e] type 0 class 0x000880 [ 2.946922] pci 0000:7f:16.7: [8086:2f6f] type 0 class 0x000880 [ 2.946949] pci 0000:7f:17.0: [8086:2fd0] type 0 class 0x000880 [ 2.946975] pci 0000:7f:17.4: [8086:2fb8] type 0 class 0x000880 [ 2.947001] pci 0000:7f:17.5: [8086:2fb9] type 0 class 0x000880 [ 2.947027] pci 0000:7f:17.6: [8086:2fba] type 0 class 0x000880 [ 2.947057] pci 0000:7f:17.7: [8086:2fbb] type 0 class 0x000880 [ 2.947087] pci 0000:7f:1e.0: [8086:2f98] type 0 class 0x000880 [ 2.947112] pci 0000:7f:1e.1: [8086:2f99] type 0 class 0x000880 [ 2.947136] pci 0000:7f:1e.2: [8086:2f9a] type 0 class 0x000880 [ 2.947162] pci 0000:7f:1e.3: [8086:2fc0] type 0 class 0x000880 [ 2.947168] pci 0000:7f:1e.3: reg 10: [mem 0x00000010-0x0000001f 64bit pref] [ 2.947188] pci 0000:7f:1e.4: [8086:2f9c] type 0 class 0x000880 [ 2.947215] pci 0000:7f:1f.0: [8086:2f88] type 0 class 0x000880 [ 2.947239] pci 0000:7f:1f.2: [8086:2f8a] type 0 class 0x000880 [ 2.947266] ACPI: PCI Interrupt Routing Table [\_SB_.UNC0._PRT] [ 2.947765] pci0000:7f: Requesting ACPI _OSC control (0x1d) [ 2.948981] pci0000:7f: ACPI _OSC control (0x15) granted [ 3.951045] ACPI: PCI Root Bridge [PCI0] (domain 0000 [bus 00-7e]) [ 3.951463] pci_root PNP0A08:00: host bridge window [io 0x0000-0x0cf7] [ 3.951809] pci_root PNP0A08:00: host bridge window [io 0x1000-0x9fff] [ 3.952158] pci_root PNP0A08:00: host bridge window [mem 0x000a0000-0x000bffff] [ 3.952777] pci_root PNP0A08:00: host bridge window [mem 0xfedb0000-0xfedb000f] [ 3.953397] pci_root PNP0A08:00: host bridge window [mem 0xfedc0000-0xfedc000f] [ 3.954017] pci_root PNP0A08:00: host bridge window [mem 0x90000000-0xc7ffbfff] [ 3.954643] pci 0000:00:00.0: [8086:2f00] type 0 class 0x000600 [ 3.954681] pci 0000:00:01.0: [8086:2f02] type 1 class 0x000604 [ 3.954710] pci 0000:00:01.0: PME# supported from D0 D3hot D3cold [ 3.954712] pci 0000:00:01.0: PME# disabled [ 3.954728] pci 0000:00:02.0: [8086:2f04] type 1 class 0x000604 [ 3.954756] pci 0000:00:02.0: PME# supported from D0 D3hot D3cold [ 3.954758] pci 0000:00:02.0: PME# disabled [ 3.954774] pci 0000:00:02.2: [8086:2f06] type 1 class 0x000604 [ 3.954802] pci 0000:00:02.2: PME# supported from D0 D3hot D3cold [ 3.954804] pci 0000:00:02.2: PME# disabled [ 3.954822] pci 0000:00:03.0: [8086:2f08] type 1 class 0x000604 [ 3.954850] pci 0000:00:03.0: PME# supported from D0 D3hot D3cold [ 3.954852] pci 0000:00:03.0: PME# disabled [ 3.954866] pci 0000:00:05.0: [8086:2f28] type 0 class 0x000880 [ 3.954905] pci 0000:00:05.1: [8086:2f29] type 0 class 0x000880 [ 3.954947] pci 0000:00:05.2: [8086:2f2a] type 0 class 0x000880 [ 3.955001] pci 0000:00:05.4: [8086:2f2c] type 0 class 0x000800 [ 3.955007] pci 0000:00:05.4: reg 10: [mem 0xc7817000-0xc7817fff] [ 3.955057] pci 0000:00:11.0: [8086:8d7c] type 0 class 0x00ff00 [ 3.955164] pci 0000:00:16.0: [8086:8d3a] type 0 class 0x000780 [ 3.955181] pci 0000:00:16.0: reg 10: [mem 0xc7816000-0xc781600f 64bit] [ 3.955227] pci 0000:00:16.0: PME# supported from D0 D3hot D3cold [ 3.955230] pci 0000:00:16.0: PME# disabled [ 3.955247] pci 0000:00:16.1: [8086:8d3b] type 0 class 0x000780 [ 3.955264] pci 0000:00:16.1: reg 10: [mem 0xc7815000-0xc781500f 64bit] [ 3.955310] pci 0000:00:16.1: PME# supported from D0 D3hot D3cold [ 3.955313] pci 0000:00:16.1: PME# disabled [ 3.955340] pci 0000:00:1a.0: [8086:8d2d] type 0 class 0x000c03 [ 3.955359] pci 0000:00:1a.0: reg 10: [mem 0xc7813000-0xc78133ff] [ 3.955424] pci 0000:00:1a.0: PME# supported from D0 D3hot D3cold [ 3.955428] pci 0000:00:1a.0: PME# disabled [ 3.955446] pci 0000:00:1c.0: [8086:8d10] type 1 class 0x000604 [ 3.955493] pci 0000:00:1c.0: PME# supported from D0 D3hot D3cold [ 3.955496] pci 0000:00:1c.0: PME# disabled [ 3.955516] pci 0000:00:1c.4: [8086:8d18] type 1 class 0x000604 [ 3.955564] pci 0000:00:1c.4: PME# supported from D0 D3hot D3cold [ 3.955567] pci 0000:00:1c.4: PME# disabled [ 3.955593] pci 0000:00:1d.0: [8086:8d26] type 0 class 0x000c03 [ 3.955611] pci 0000:00:1d.0: reg 10: [mem 0xc7812000-0xc78123ff] [ 3.955676] pci 0000:00:1d.0: PME# supported from D0 D3hot D3cold [ 3.955680] pci 0000:00:1d.0: PME# disabled [ 3.955703] pci 0000:00:1f.0: [8086:8d44] type 0 class 0x000601 [ 3.955801] pci 0000:00:1f.3: [8086:8d22] type 0 class 0x000c05 [ 3.955814] pci 0000:00:1f.3: reg 10: [mem 0xc7811000-0xc78110ff 64bit] [ 3.955832] pci 0000:00:1f.3: reg 20: [io 0x0580-0x059f] [ 3.955886] pci 0000:01:00.0: [8086:1521] type 0 class 0x000200 [ 3.955895] pci 0000:01:00.0: reg 10: [mem 0xc7720000-0xc773ffff] [ 3.955907] pci 0000:01:00.0: reg 18: [io 0x8020-0x803f] [ 3.955914] pci 0000:01:00.0: reg 1c: [mem 0xc7744000-0xc7747fff] [ 3.955952] pci 0000:01:00.0: PME# supported from D0 D3hot D3cold [ 3.955954] pci 0000:01:00.0: PME# disabled [ 3.955982] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.955996] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.956020] pci 0000:01:00.1: [8086:1521] type 0 class 0x000200 [ 3.956029] pci 0000:01:00.1: reg 10: [mem 0xc7700000-0xc771ffff] [ 3.956042] pci 0000:01:00.1: reg 18: [io 0x8000-0x801f] [ 3.956048] pci 0000:01:00.1: reg 1c: [mem 0xc7740000-0xc7743fff] [ 3.956085] pci 0000:01:00.1: PME# supported from D0 D3hot D3cold [ 3.956088] pci 0000:01:00.1: PME# disabled [ 3.956112] pci 0000:01:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 3.956125] pci 0000:01:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 3.956142] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 3.956487] pci 0000:00:01.0: bridge window [io 0x8000-0x8fff] [ 3.956490] pci 0000:00:01.0: bridge window [mem 0xc7700000-0xc77fffff] [ 3.956493] pci 0000:00:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.956516] pci 0000:00:02.0: PCI bridge to [bus 02-02] [ 3.956861] pci 0000:00:02.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.956863] pci 0000:00:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.956866] pci 0000:00:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.956899] pci 0000:03:00.0: [10b5:8632] type 1 class 0x000604 [ 3.956908] pci 0000:03:00.0: reg 10: [mem 0xc7600000-0xc761ffff] [ 3.956944] pci 0000:03:00.0: PME# supported from D0 D3hot D3cold [ 3.956947] pci 0000:03:00.0: PME# disabled [ 3.956966] pci 0000:00:02.2: PCI bridge to [bus 03-23] [ 3.957311] pci 0000:00:02.2: bridge window [io 0x1000-0x6fff] [ 3.957314] pci 0000:00:02.2: bridge window [mem 0xc7100000-0xc76fffff] [ 3.957317] pci 0000:00:02.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.957361] pci 0000:04:01.0: [10b5:8632] type 1 class 0x000604 [ 3.957405] pci 0000:04:01.0: PME# supported from D0 D3hot D3cold [ 3.957408] pci 0000:04:01.0: PME# disabled [ 3.957430] pci 0000:04:02.0: [10b5:8632] type 1 class 0x000604 [ 3.957473] pci 0000:04:02.0: PME# supported from D0 D3hot D3cold [ 3.957476] pci 0000:04:02.0: PME# disabled [ 3.957497] pci 0000:04:03.0: [10b5:8632] type 1 class 0x000604 [ 3.957541] pci 0000:04:03.0: PME# supported from D0 D3hot D3cold [ 3.957544] pci 0000:04:03.0: PME# disabled [ 3.957568] pci 0000:04:04.0: [10b5:8632] type 1 class 0x000604 [ 3.957612] pci 0000:04:04.0: PME# supported from D0 D3hot D3cold [ 3.957615] pci 0000:04:04.0: PME# disabled [ 3.957636] pci 0000:04:05.0: [10b5:8632] type 1 class 0x000604 [ 3.957680] pci 0000:04:05.0: PME# supported from D0 D3hot D3cold [ 3.957683] pci 0000:04:05.0: PME# disabled [ 3.957713] pci 0000:03:00.0: PCI bridge to [bus 04-23] [ 3.958061] pci 0000:03:00.0: bridge window [io 0x1000-0x6fff] [ 3.958064] pci 0000:03:00.0: bridge window [mem 0xc7100000-0xc75fffff] [ 3.958069] pci 0000:03:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.958103] pci 0000:04:01.0: PCI bridge to [bus 05-05] [ 3.958448] pci 0000:04:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.958451] pci 0000:04:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.958456] pci 0000:04:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.958491] pci 0000:04:02.0: PCI bridge to [bus 06-06] [ 3.958838] pci 0000:04:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.958841] pci 0000:04:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.958846] pci 0000:04:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.958881] pci 0000:04:03.0: PCI bridge to [bus 07-07] [ 3.959228] pci 0000:04:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.959231] pci 0000:04:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.959236] pci 0000:04:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.959284] pci 0000:08:00.0: [111d:8032] type 1 class 0x000604 [ 3.959364] pci 0000:08:00.0: PME# supported from D0 D3hot D3cold [ 3.959369] pci 0000:08:00.0: PME# disabled [ 3.959394] pci 0000:04:04.0: PCI bridge to [bus 08-11] [ 3.959740] pci 0000:04:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.959743] pci 0000:04:04.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.959747] pci 0000:04:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.959811] pci 0000:09:02.0: [111d:8032] type 1 class 0x000604 [ 3.959898] pci 0000:09:02.0: PME# supported from D0 D3hot D3cold [ 3.959902] pci 0000:09:02.0: PME# disabled [ 3.959934] pci 0000:09:03.0: [111d:8032] type 1 class 0x000604 [ 3.960022] pci 0000:09:03.0: PME# supported from D0 D3hot D3cold [ 3.960026] pci 0000:09:03.0: PME# disabled [ 3.960059] pci 0000:09:04.0: [111d:8032] type 1 class 0x000604 [ 3.960146] pci 0000:09:04.0: PME# supported from D0 D3hot D3cold [ 3.960150] pci 0000:09:04.0: PME# disabled [ 3.960184] pci 0000:09:06.0: [111d:8032] type 1 class 0x000604 [ 3.960270] pci 0000:09:06.0: PME# supported from D0 D3hot D3cold [ 3.960275] pci 0000:09:06.0: PME# disabled [ 3.960307] pci 0000:09:07.0: [111d:8032] type 1 class 0x000604 [ 3.960393] pci 0000:09:07.0: PME# supported from D0 D3hot D3cold [ 3.960398] pci 0000:09:07.0: PME# disabled [ 3.960433] pci 0000:09:08.0: [111d:8032] type 1 class 0x000604 [ 3.960520] pci 0000:09:08.0: PME# supported from D0 D3hot D3cold [ 3.960525] pci 0000:09:08.0: PME# disabled [ 3.960558] pci 0000:09:0a.0: [111d:8032] type 1 class 0x000604 [ 3.960645] pci 0000:09:0a.0: PME# supported from D0 D3hot D3cold [ 3.960650] pci 0000:09:0a.0: PME# disabled [ 3.960682] pci 0000:09:0b.0: [111d:8032] type 1 class 0x000604 [ 3.960768] pci 0000:09:0b.0: PME# supported from D0 D3hot D3cold [ 3.960773] pci 0000:09:0b.0: PME# disabled [ 3.960817] pci 0000:08:00.0: PCI bridge to [bus 09-11] [ 3.961169] pci 0000:08:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.961174] pci 0000:08:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.961182] pci 0000:08:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.961241] pci 0000:09:02.0: PCI bridge to [bus 0a-0a] [ 3.961591] pci 0000:09:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.961596] pci 0000:09:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.961605] pci 0000:09:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.961665] pci 0000:09:03.0: PCI bridge to [bus 0b-0b] [ 3.962018] pci 0000:09:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.962023] pci 0000:09:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.962032] pci 0000:09:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.962092] pci 0000:09:04.0: PCI bridge to [bus 0c-0c] [ 3.962442] pci 0000:09:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.962447] pci 0000:09:04.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.962456] pci 0000:09:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.962516] pci 0000:09:06.0: PCI bridge to [bus 0d-0d] [ 3.962884] pci 0000:09:06.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.962889] pci 0000:09:06.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.962897] pci 0000:09:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.962957] pci 0000:09:07.0: PCI bridge to [bus 0e-0e] [ 3.963307] pci 0000:09:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.963312] pci 0000:09:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.963320] pci 0000:09:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.963381] pci 0000:09:08.0: PCI bridge to [bus 0f-0f] [ 3.963730] pci 0000:09:08.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.963735] pci 0000:09:08.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.963743] pci 0000:09:08.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.963803] pci 0000:09:0a.0: PCI bridge to [bus 10-10] [ 3.964153] pci 0000:09:0a.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.964158] pci 0000:09:0a.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.964167] pci 0000:09:0a.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.964227] pci 0000:09:0b.0: PCI bridge to [bus 11-11] [ 3.964576] pci 0000:09:0b.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.964581] pci 0000:09:0b.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.964589] pci 0000:09:0b.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.964706] pci 0000:12:00.0: [111d:8032] type 1 class 0x000604 [ 3.964786] pci 0000:12:00.0: PME# supported from D0 D3hot D3cold [ 3.964790] pci 0000:12:00.0: PME# disabled [ 3.964815] pci 0000:04:05.0: PCI bridge to [bus 12-23] [ 3.965161] pci 0000:04:05.0: bridge window [io 0x1000-0x6fff] [ 3.965164] pci 0000:04:05.0: bridge window [mem 0xc7100000-0xc75fffff] [ 3.965168] pci 0000:04:05.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.965231] pci 0000:13:02.0: [111d:8032] type 1 class 0x000604 [ 3.965317] pci 0000:13:02.0: PME# supported from D0 D3hot D3cold [ 3.965322] pci 0000:13:02.0: PME# disabled [ 3.965353] pci 0000:13:03.0: [111d:8032] type 1 class 0x000604 [ 3.965439] pci 0000:13:03.0: PME# supported from D0 D3hot D3cold [ 3.965443] pci 0000:13:03.0: PME# disabled [ 3.965475] pci 0000:13:04.0: [111d:8032] type 1 class 0x000604 [ 3.965561] pci 0000:13:04.0: PME# supported from D0 D3hot D3cold [ 3.965565] pci 0000:13:04.0: PME# disabled [ 3.965598] pci 0000:13:06.0: [111d:8032] type 1 class 0x000604 [ 3.965684] pci 0000:13:06.0: PME# supported from D0 D3hot D3cold [ 3.965688] pci 0000:13:06.0: PME# disabled [ 3.965722] pci 0000:13:07.0: [111d:8032] type 1 class 0x000604 [ 3.965808] pci 0000:13:07.0: PME# supported from D0 D3hot D3cold [ 3.965813] pci 0000:13:07.0: PME# disabled [ 3.965844] pci 0000:13:08.0: [111d:8032] type 1 class 0x000604 [ 3.965930] pci 0000:13:08.0: PME# supported from D0 D3hot D3cold [ 3.965935] pci 0000:13:08.0: PME# disabled [ 3.965968] pci 0000:13:0a.0: [111d:8032] type 1 class 0x000604 [ 3.966054] pci 0000:13:0a.0: PME# supported from D0 D3hot D3cold [ 3.966059] pci 0000:13:0a.0: PME# disabled [ 3.966090] pci 0000:13:0b.0: [111d:8032] type 1 class 0x000604 [ 3.966176] pci 0000:13:0b.0: PME# supported from D0 D3hot D3cold [ 3.966180] pci 0000:13:0b.0: PME# disabled [ 3.966223] pci 0000:12:00.0: PCI bridge to [bus 13-23] [ 3.966573] pci 0000:12:00.0: bridge window [io 0x1000-0x6fff] [ 3.966577] pci 0000:12:00.0: bridge window [mem 0xc7100000-0xc75fffff] [ 3.966586] pci 0000:12:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.966670] pci 0000:14:00.0: [104c:8231] type 1 class 0x000604 [ 3.966784] pci 0000:14:00.0: supports D1 D2 [ 3.966819] pci 0000:13:02.0: PCI bridge to [bus 14-15] [ 3.967169] pci 0000:13:02.0: bridge window [io 0x6000-0x6fff] [ 3.967173] pci 0000:13:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.967182] pci 0000:13:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.967284] pci 0000:15:00.0: [1221:8632] type 0 class 0x000480 [ 3.967310] pci 0000:15:00.0: reg 10: [io 0x6000-0x601f] [ 3.967496] pci 0000:14:00.0: PCI bridge to [bus 15-15] [ 3.967847] pci 0000:14:00.0: bridge window [io 0x6000-0x6fff] [ 3.967852] pci 0000:14:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.967862] pci 0000:14:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.967958] pci 0000:16:00.0: [104c:8231] type 1 class 0x000604 [ 3.968070] pci 0000:16:00.0: supports D1 D2 [ 3.968105] pci 0000:13:03.0: PCI bridge to [bus 16-17] [ 3.968454] pci 0000:13:03.0: bridge window [io 0x5000-0x5fff] [ 3.968459] pci 0000:13:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.968467] pci 0000:13:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.968568] pci 0000:17:00.0: [1221:86e2] type 0 class 0x000480 [ 3.968593] pci 0000:17:00.0: reg 10: [io 0x5000-0x501f] [ 3.968779] pci 0000:16:00.0: PCI bridge to [bus 17-17] [ 3.969131] pci 0000:16:00.0: bridge window [io 0x5000-0x5fff] [ 3.969136] pci 0000:16:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.969146] pci 0000:16:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.969244] pci 0000:18:00.0: [10b5:8111] type 1 class 0x000604 [ 3.969363] pci 0000:18:00.0: supports D1 [ 3.969365] pci 0000:18:00.0: PME# supported from D0 D1 D3hot [ 3.969370] pci 0000:18:00.0: PME# disabled [ 3.969405] pci 0000:13:04.0: PCI bridge to [bus 18-19] [ 3.969753] pci 0000:13:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.969758] pci 0000:13:04.0: bridge window [mem 0xc7500000-0xc75fffff] [ 3.969766] pci 0000:13:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.969888] pci 0000:19:04.0: [10b5:9056] type 0 class 0x001180 [ 3.969930] pci 0000:19:04.0: reg 10: [mem 0xc7501000-0xc75011ff] [ 3.969964] pci 0000:19:04.0: reg 18: [mem 0xc7500000-0xc75001ff] [ 3.970164] pci 0000:18:00.0: PCI bridge to [bus 19-19] [ 3.970511] pci 0000:18:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.970517] pci 0000:18:00.0: bridge window [mem 0xc7500000-0xc75fffff] [ 3.970523] pci 0000:18:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.970620] pci 0000:1a:00.0: [10b5:8112] type 1 class 0x000604 [ 3.970739] pci 0000:1a:00.0: supports D1 [ 3.970740] pci 0000:1a:00.0: PME# supported from D0 D1 D3hot [ 3.970746] pci 0000:1a:00.0: PME# disabled [ 3.970780] pci 0000:13:06.0: PCI bridge to [bus 1a-1b] [ 3.971130] pci 0000:13:06.0: bridge window [io 0xfff000-0x0000] (disabled) [ 3.971135] pci 0000:13:06.0: bridge window [mem 0xc7400000-0xc74fffff] [ 3.971143] pci 0000:13:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.971263] pci 0000:1b:00.0: [10b5:9056] type 0 class 0x000680 [ 3.971304] pci 0000:1b:00.0: reg 10: [mem 0xc7401000-0xc74011ff] [ 3.971338] pci 0000:1b:00.0: reg 18: [mem 0xc7400000-0xc74001ff] [ 3.971544] pci 0000:1a:00.0: PCI bridge to [bus 1b-1b] [ 3.971891] pci 0000:1a:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.971897] pci 0000:1a:00.0: bridge window [mem 0xc7400000-0xc74fffff] [ 3.971902] pci 0000:1a:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.972001] pci 0000:1c:00.0: [104c:8240] type 1 class 0x000604 [ 3.972114] pci 0000:1c:00.0: supports D1 D2 [ 3.972152] pci 0000:13:07.0: PCI bridge to [bus 1c-1d] [ 3.972502] pci 0000:13:07.0: bridge window [io 0x4000-0x4fff] [ 3.972507] pci 0000:13:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.972515] pci 0000:13:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.972619] pci 0000:1d:00.0: [1221:8682] type 0 class 0x000480 [ 3.972645] pci 0000:1d:00.0: reg 10: [io 0x4000-0x401f] [ 3.972851] pci 0000:1c:00.0: PCI bridge to [bus 1d-1d] [ 3.973202] pci 0000:1c:00.0: bridge window [io 0x4000-0x4fff] [ 3.973207] pci 0000:1c:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.973217] pci 0000:1c:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.973319] pci 0000:1e:00.0: [10b5:8111] type 1 class 0x000604 [ 3.973437] pci 0000:1e:00.0: supports D1 [ 3.973438] pci 0000:1e:00.0: PME# supported from D0 D1 D3hot [ 3.973444] pci 0000:1e:00.0: PME# disabled [ 3.973479] pci 0000:13:08.0: PCI bridge to [bus 1e-1f] [ 3.973827] pci 0000:13:08.0: bridge window [io 0x3000-0x3fff] [ 3.973832] pci 0000:13:08.0: bridge window [mem 0xc7300000-0xc73fffff] [ 3.973840] pci 0000:13:08.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.973960] pci 0000:1f:04.0: [10b5:9056] type 0 class 0x001180 [ 3.974002] pci 0000:1f:04.0: reg 10: [mem 0xc7301000-0xc73011ff] [ 3.974019] pci 0000:1f:04.0: reg 14: [io 0x3000-0x30ff] [ 3.974037] pci 0000:1f:04.0: reg 18: [mem 0xc7300000-0xc73001ff] [ 3.974234] pci 0000:1e:00.0: PCI bridge to [bus 1f-1f] [ 3.974581] pci 0000:1e:00.0: bridge window [io 0x3000-0x3fff] [ 3.974586] pci 0000:1e:00.0: bridge window [mem 0xc7300000-0xc73fffff] [ 3.974597] pci 0000:1e:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.974695] pci 0000:20:00.0: [10b5:8111] type 1 class 0x000604 [ 3.974814] pci 0000:20:00.0: supports D1 [ 3.974815] pci 0000:20:00.0: PME# supported from D0 D1 D3hot [ 3.974821] pci 0000:20:00.0: PME# disabled [ 3.974855] pci 0000:13:0a.0: PCI bridge to [bus 20-21] [ 3.975204] pci 0000:13:0a.0: bridge window [io 0x2000-0x2fff] [ 3.975209] pci 0000:13:0a.0: bridge window [mem 0xc7200000-0xc72fffff] [ 3.975217] pci 0000:13:0a.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.975337] pci 0000:21:04.0: [10b5:9056] type 0 class 0x001180 [ 3.975378] pci 0000:21:04.0: reg 10: [mem 0xc7201000-0xc72011ff] [ 3.975396] pci 0000:21:04.0: reg 14: [io 0x2000-0x20ff] [ 3.975414] pci 0000:21:04.0: reg 18: [mem 0xc7200000-0xc72001ff] [ 3.975610] pci 0000:20:00.0: PCI bridge to [bus 21-21] [ 3.975957] pci 0000:20:00.0: bridge window [io 0x2000-0x2fff] [ 3.975962] pci 0000:20:00.0: bridge window [mem 0xc7200000-0xc72fffff] [ 3.975973] pci 0000:20:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.976070] pci 0000:22:00.0: [10b5:8111] type 1 class 0x000604 [ 3.976188] pci 0000:22:00.0: supports D1 [ 3.976190] pci 0000:22:00.0: PME# supported from D0 D1 D3hot [ 3.976195] pci 0000:22:00.0: PME# disabled [ 3.976230] pci 0000:13:0b.0: PCI bridge to [bus 22-23] [ 3.976578] pci 0000:13:0b.0: bridge window [io 0x1000-0x1fff] [ 3.976582] pci 0000:13:0b.0: bridge window [mem 0xc7100000-0xc71fffff] [ 3.976590] pci 0000:13:0b.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.976710] pci 0000:23:04.0: [10b5:9056] type 0 class 0x001180 [ 3.976752] pci 0000:23:04.0: reg 10: [mem 0xc7101000-0xc71011ff] [ 3.976769] pci 0000:23:04.0: reg 14: [io 0x1000-0x10ff] [ 3.976787] pci 0000:23:04.0: reg 18: [mem 0xc7100000-0xc71001ff] [ 3.976984] pci 0000:22:00.0: PCI bridge to [bus 23-23] [ 3.977331] pci 0000:22:00.0: bridge window [io 0x1000-0x1fff] [ 3.977337] pci 0000:22:00.0: bridge window [mem 0xc7100000-0xc71fffff] [ 3.977347] pci 0000:22:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.977468] pci 0000:00:03.0: PCI bridge to [bus 24-24] [ 3.977811] pci 0000:00:03.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.977814] pci 0000:00:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.977817] pci 0000:00:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.977851] pci 0000:00:1c.0: PCI bridge to [bus 25-25] [ 3.978195] pci 0000:00:1c.0: bridge window [io 0xf000-0x0000] (disabled) [ 3.978198] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 3.978203] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.978254] pci 0000:26:00.0: [1a03:1150] type 1 class 0x000604 [ 3.978343] pci 0000:26:00.0: supports D1 D2 [ 3.978344] pci 0000:26:00.0: PME# supported from D0 D1 D2 D3hot D3cold [ 3.978348] pci 0000:26:00.0: PME# disabled [ 3.978377] pci 0000:00:1c.4: PCI bridge to [bus 26-27] [ 3.978721] pci 0000:00:1c.4: bridge window [io 0x7000-0x7fff] [ 3.978724] pci 0000:00:1c.4: bridge window [mem 0xc6000000-0xc70fffff] [ 3.978728] pci 0000:00:1c.4: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.978811] pci 0000:27:00.0: [1a03:2000] type 0 class 0x000300 [ 3.978837] pci 0000:27:00.0: reg 10: [mem 0xc6000000-0xc6ffffff] [ 3.978851] pci 0000:27:00.0: reg 14: [mem 0xc7000000-0xc701ffff] [ 3.978864] pci 0000:27:00.0: reg 18: [io 0x7000-0x707f] [ 3.978943] pci 0000:27:00.0: supports D1 D2 [ 3.978944] pci 0000:27:00.0: PME# supported from D0 D1 D2 D3hot D3cold [ 3.978948] pci 0000:27:00.0: PME# disabled [ 3.979013] pci 0000:26:00.0: PCI bridge to [bus 27-27] [ 3.979361] pci 0000:26:00.0: bridge window [io 0x7000-0x7fff] [ 3.979366] pci 0000:26:00.0: bridge window [mem 0xc6000000-0xc70fffff] [ 3.979373] pci 0000:26:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 3.979398] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0._PRT] [ 3.979509] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP05._PRT] [ 3.979522] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP05.BR6F._PRT] [ 3.979550] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR3A._PRT] [ 3.979600] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR1A._PRT] [ 3.979661] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR2A._PRT] [ 3.979695] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR2C._PRT] [ 3.979948] pci0000:00: Requesting ACPI _OSC control (0x1d) [ 3.980858] pci0000:00: ACPI _OSC control (0x15) granted [ 4.988910] ACPI: PCI Root Bridge [PCI1] (domain 0000 [bus 80-fe]) [ 4.989337] pci_root PNP0A08:01: host bridge window [io 0xa000-0xffff] [ 4.989685] pci_root PNP0A08:01: host bridge window [mem 0xc8000000-0xfbffbfff] [ 4.990314] pci 0000:80:02.0: [8086:2f04] type 1 class 0x000604 [ 4.990348] pci 0000:80:02.0: PME# supported from D0 D3hot D3cold [ 4.990350] pci 0000:80:02.0: PME# disabled [ 4.990368] pci 0000:80:02.2: [8086:2f06] type 1 class 0x000604 [ 4.990400] pci 0000:80:02.2: PME# supported from D0 D3hot D3cold [ 4.990402] pci 0000:80:02.2: PME# disabled [ 4.990424] pci 0000:80:03.0: [8086:2f08] type 1 class 0x000604 [ 4.990456] pci 0000:80:03.0: PME# supported from D0 D3hot D3cold [ 4.990458] pci 0000:80:03.0: PME# disabled [ 4.990476] pci 0000:80:03.2: [8086:2f0a] type 1 class 0x000604 [ 4.990507] pci 0000:80:03.2: PME# supported from D0 D3hot D3cold [ 4.990509] pci 0000:80:03.2: PME# disabled [ 4.990527] pci 0000:80:05.0: [8086:2f28] type 0 class 0x000880 [ 4.990570] pci 0000:80:05.1: [8086:2f29] type 0 class 0x000880 [ 4.990617] pci 0000:80:05.2: [8086:2f2a] type 0 class 0x000880 [ 4.990661] pci 0000:80:05.4: [8086:2f2c] type 0 class 0x000800 [ 4.990667] pci 0000:80:05.4: reg 10: [mem 0xf8200000-0xf8200fff] [ 4.990741] pci 0000:80:02.0: PCI bridge to [bus 81-81] [ 4.991087] pci 0000:80:02.0: bridge window [io 0xf000-0x0000] (disabled) [ 4.991089] pci 0000:80:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 4.991093] pci 0000:80:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 4.991133] pci 0000:82:00.0: [1ad7:8000] type 0 class 0x001110 [ 4.991147] pci 0000:82:00.0: reg 10: [mem 0xf8100000-0xf81001ff] [ 4.991247] pci 0000:80:02.2: PCI bridge to [bus 82-82] [ 4.991592] pci 0000:80:02.2: bridge window [io 0xf000-0x0000] (disabled) [ 4.991594] pci 0000:80:02.2: bridge window [mem 0xf8100000-0xf81fffff] [ 4.991598] pci 0000:80:02.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 4.991624] pci 0000:80:03.0: PCI bridge to [bus 83-83] [ 4.991969] pci 0000:80:03.0: bridge window [io 0xf000-0x0000] (disabled) [ 4.991971] pci 0000:80:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 4.991975] pci 0000:80:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 4.992007] pci 0000:84:00.0: [8086:032d] type 1 class 0x000604 [ 4.992044] pci 0000:84:00.0: PME# supported from D0 D3hot D3cold [ 4.992047] pci 0000:84:00.0: PME# disabled [ 4.992065] pci 0000:80:03.2: PCI bridge to [bus 84-85] [ 4.992410] pci 0000:80:03.2: bridge window [io 0xf000-0xffff] [ 4.992412] pci 0000:80:03.2: bridge window [mem 0xf0000000-0xf80fffff] [ 4.992416] pci 0000:80:03.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 4.992462] pci 0000:85:0c.0: [114a:5565] type 0 class 0x000280 [ 4.992474] pci 0000:85:0c.0: reg 10: [mem 0xf8001000-0xf80011ff] [ 4.992482] pci 0000:85:0c.0: reg 14: [io 0xf000-0xf0ff] [ 4.992489] pci 0000:85:0c.0: reg 18: [mem 0xf8000000-0xf800003f] [ 4.992496] pci 0000:85:0c.0: reg 1c: [mem 0xf0000000-0xf7ffffff] [ 4.992548] pci 0000:84:00.0: PCI bridge to [bus 85-85] [ 4.992893] pci 0000:84:00.0: bridge window [io 0xf000-0xffff] [ 4.992896] pci 0000:84:00.0: bridge window [mem 0xf0000000-0xf80fffff] [ 4.992900] pci 0000:84:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 4.992915] ACPI: PCI Interrupt Routing Table [\_SB_.PCI1._PRT] [ 4.992982] ACPI: PCI Interrupt Routing Table [\_SB_.PCI1.QR2A._PRT] [ 4.993031] ACPI: PCI Interrupt Routing Table [\_SB_.PCI1.QR2C._PRT] [ 4.993067] ACPI: PCI Interrupt Routing Table [\_SB_.PCI1.QR3A._PRT] [ 4.993102] ACPI: PCI Interrupt Routing Table [\_SB_.PCI1.QR3C._PRT] [ 4.993376] pci0000:80: Requesting ACPI _OSC control (0x1d) [ 4.994290] pci0000:80: ACPI _OSC control (0x15) granted [ 4.996607] ACPI: PCI Interrupt Link [LNKA] (IRQs 3 4 5 6 7 10 *11 12 14 15) [ 4.997718] ACPI: PCI Interrupt Link [LNKB] (IRQs 3 4 5 6 7 *10 11 12 14 15) [ 4.998826] ACPI: PCI Interrupt Link [LNKC] (IRQs 3 4 *5 6 10 11 12 14 15) [ 4.999873] ACPI: PCI Interrupt Link [LNKD] (IRQs *3 4 5 6 10 11 12 14 15) [ 5.000918] ACPI: PCI Interrupt Link [LNKE] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 5.002435] ACPI: PCI Interrupt Link [LNKF] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 5.003934] ACPI: PCI Interrupt Link [LNKG] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 5.005432] ACPI: PCI Interrupt Link [LNKH] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 5.007114] vgaarb: device added: PCI:0000:27:00.0,decodes=io+mem,owns=io+mem,locks=none [ 5.007735] vgaarb: loaded [ 5.008074] vgaarb: bridge control possible 0000:27:00.0 [ 5.008629] SCSI subsystem initialized [ 5.009109] libata version 3.00 loaded. [ 5.009355] usbcore: registered new interface driver usbfs [ 5.009748] usbcore: registered new interface driver hub [ 5.010155] usbcore: registered new device driver usb [ 5.010833] Advanced Linux Sound Architecture Driver Version 1.0.24. [ 5.011178] PCI: Using ACPI for IRQ routing [ 5.014835] PCI: pci_cache_line_size set to 64 bytes [ 5.015070] pci 0000:ff:1e.3: no compatible bridge window for [mem 0x00000010-0x0000001f 64bit pref] [ 5.015726] pci 0000:7f:1e.3: no compatible bridge window for [mem 0x00000010-0x0000001f 64bit pref] [ 5.016466] reserve RAM buffer: 000000000009ec00 - 000000000009ffff [ 5.016468] reserve RAM buffer: 00000000790c3000 - 000000007bffffff [ 5.016816] cfg80211: Calling CRDA to update world regulatory domain [ 5.017286] pnp: PnP ACPI init [ 5.017645] ACPI: bus type pnp registered [ 5.018116] pnp 00:00: [bus ff] [ 5.018449] pnp 00:00: Plug and Play ACPI device, IDs PNP0a03 (active) [ 5.018476] pnp 00:01: [bus 7f] [ 5.018606] pnp 00:01: Plug and Play ACPI device, IDs PNP0a03 (active) [ 5.018948] pnp 00:02: [bus 00-7e] [ 5.018949] pnp 00:02: [io 0x0cf8-0x0cff] [ 5.018951] pnp 00:02: [io 0x0000-0x0cf7 window] [ 5.018952] pnp 00:02: [io 0x1000-0x9fff window] [ 5.018954] pnp 00:02: [mem 0x000a0000-0x000bffff window] [ 5.018955] pnp 00:02: [mem 0xfedb0000-0xfedb000f window] [ 5.018956] pnp 00:02: [mem 0xfedc0000-0xfedc000f window] [ 5.018958] pnp 00:02: [mem 0x90000000-0xc7ffbfff window] [ 5.018959] pnp 00:02: [mem 0x00000000 window] [ 5.019100] pnp 00:02: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 5.019106] pnp 00:03: [mem 0xfec00000-0xfecfffff] [ 5.019148] pnp 00:03: Plug and Play ACPI device, IDs PNP0003 (active) [ 5.019161] pnp 00:04: [io 0x0000-0x000f] [ 5.019162] pnp 00:04: [io 0x0081-0x0083] [ 5.019163] pnp 00:04: [io 0x0087] [ 5.019164] pnp 00:04: [io 0x0089-0x008b] [ 5.019165] pnp 00:04: [io 0x008f] [ 5.019166] pnp 00:04: [io 0x00c0-0x00df] [ 5.019168] pnp 00:04: [dma 4] [ 5.019213] pnp 00:04: Plug and Play ACPI device, IDs PNP0200 (active) [ 5.019219] pnp 00:05: [io 0x0070-0x0071] [ 5.019220] pnp 00:05: [io 0x0074-0x0077] [ 5.019228] pnp 00:05: [irq 8] [ 5.019276] pnp 00:05: Plug and Play ACPI device, IDs PNP0b00 (active) [ 5.019282] pnp 00:06: [io 0x00f0] [ 5.019286] pnp 00:06: [irq 13] [ 5.019329] pnp 00:06: Plug and Play ACPI device, IDs PNP0c04 (active) [ 5.019334] pnp 00:07: [io 0x0061] [ 5.019378] pnp 00:07: Plug and Play ACPI device, IDs PNP0800 (active) [ 5.019394] pnp 00:08: [io 0x0500-0x057f] [ 5.019395] pnp 00:08: [io 0x0400-0x047f] [ 5.019397] pnp 00:08: [io 0x0092] [ 5.019397] pnp 00:08: [io 0x0010-0x001f] [ 5.019399] pnp 00:08: [io 0x0072-0x0073] [ 5.019400] pnp 00:08: [io 0x0080] [ 5.019401] pnp 00:08: [io 0x0084-0x0086] [ 5.019402] pnp 00:08: [io 0x0088] [ 5.019403] pnp 00:08: [io 0x008c-0x008e] [ 5.019404] pnp 00:08: [io 0x0090-0x009f] [ 5.019405] pnp 00:08: [io 0x0580-0x059f] [ 5.019406] pnp 00:08: [io 0x0600-0x061f] [ 5.019407] pnp 00:08: [io 0x0880-0x0883] [ 5.019408] pnp 00:08: [io 0x0800-0x081f] [ 5.019410] pnp 00:08: [mem 0xfed1c000-0xfed3ffff] [ 5.019411] pnp 00:08: [mem 0xfed45000-0xfed8bfff] [ 5.019412] pnp 00:08: [mem 0xff000000-0xffffffff] [ 5.019417] pnp 00:08: [mem 0xfee00000-0xfeefffff] [ 5.019418] pnp 00:08: [mem 0xfed12000-0xfed1200f] [ 5.019419] pnp 00:08: [mem 0xfed12010-0xfed1201f] [ 5.019420] pnp 00:08: [mem 0xfed1b000-0xfed1bfff] [ 5.019604] system 00:08: [io 0x0500-0x057f] has been reserved [ 5.019965] system 00:08: [io 0x0400-0x047f] has been reserved [ 5.020324] system 00:08: [io 0x0580-0x059f] has been reserved [ 5.020682] system 00:08: [io 0x0600-0x061f] has been reserved [ 5.021042] system 00:08: [io 0x0880-0x0883] has been reserved [ 5.021399] system 00:08: [io 0x0800-0x081f] has been reserved [ 5.021759] system 00:08: [mem 0xfed1c000-0xfed3ffff] has been reserved [ 5.022120] system 00:08: [mem 0xfed45000-0xfed8bfff] has been reserved [ 5.022480] system 00:08: [mem 0xff000000-0xffffffff] has been reserved [ 5.022841] system 00:08: [mem 0xfee00000-0xfeefffff] has been reserved [ 5.023201] system 00:08: [mem 0xfed12000-0xfed1200f] has been reserved [ 5.023560] system 00:08: [mem 0xfed12010-0xfed1201f] has been reserved [ 5.023922] system 00:08: [mem 0xfed1b000-0xfed1bfff] has been reserved [ 5.024282] system 00:08: Plug and Play ACPI device, IDs PNP0c02 (active) [ 5.024419] pnp 00:09: [io 0x0000-0xffffffffffffffff disabled] [ 5.024420] pnp 00:09: [io 0x0a00-0x0a0f] [ 5.024422] pnp 00:09: [io 0x0a10-0x0a1f] [ 5.024423] pnp 00:09: [io 0x0a20-0x0a2f] [ 5.024424] pnp 00:09: [io 0x0a30-0x0a3f] [ 5.024425] pnp 00:09: [io 0x0a40-0x0a4f] [ 5.024546] system 00:09: [io 0x0a00-0x0a0f] has been reserved [ 5.024906] system 00:09: [io 0x0a10-0x0a1f] has been reserved [ 5.025264] system 00:09: [io 0x0a20-0x0a2f] has been reserved [ 5.025623] system 00:09: [io 0x0a30-0x0a3f] has been reserved [ 5.025982] system 00:09: [io 0x0a40-0x0a4f] has been reserved [ 5.026341] system 00:09: Plug and Play ACPI device, IDs PNP0c02 (active) [ 5.026557] pnp 00:0a: [io 0x0ca2] [ 5.026558] pnp 00:0a: [io 0x0ca3] [ 5.026614] pnp 00:0a: Plug and Play ACPI device, IDs IPI0001 (active) [ 5.026988] pnp 00:0b: [bus 80-fe] [ 5.026989] pnp 00:0b: [mem 0x00000000 window] [ 5.026991] pnp 00:0b: [io 0xa000-0xffff window] [ 5.026992] pnp 00:0b: [io 0x5758-0x0000 window] [ 5.026993] pnp 00:0b: [io 0x5858-0x0000 window] [ 5.026995] pnp 00:0b: [mem 0xc8000000-0xfbffbfff window] [ 5.026996] pnp 00:0b: [mem 0x00000000 window] [ 5.027125] pnp 00:0b: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 5.027451] pnp: PnP ACPI: found 12 devices [ 5.027805] ACPI: ACPI bus type pnp unregistered [ 5.036114] Switching to clocksource acpi_pm [ 5.036647] Switched to NOHz mode on CPU #0 [ 5.036651] PCI: max bus depth: 6 pci_try_num: 7 [ 5.036669] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.036677] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.036687] pci 0000:01:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.036696] pci 0000:01:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.036732] Switched to NOHz mode on CPU #6 [ 5.036735] Switched to NOHz mode on CPU #3 [ 5.036743] Switched to NOHz mode on CPU #7 [ 5.036754] Switched to NOHz mode on CPU #2 [ 5.036761] Switched to NOHz mode on CPU #5 [ 5.036784] Switched to NOHz mode on CPU #1 [ 5.036808] Switched to NOHz mode on CPU #4 [ 5.037155] pci 0000:ff:1e.3: BAR 0: trying firmware assignment [mem 0x00000010-0x0000001f 64bit pref] [ 5.037158] pci 0000:ff:1e.3: BAR 0: [mem 0x00000010-0x0000001f 64bit pref] conflicts with reserved [mem 0x00000000-0x0000ffff] [ 5.037159] pci 0000:ff:1e.3: BAR 0: can't assign mem pref (size 0x10) [ 5.037175] pci 0000:7f:1e.3: BAR 0: trying firmware assignment [mem 0x00000010-0x0000001f 64bit pref] [ 5.037177] pci 0000:7f:1e.3: BAR 0: [mem 0x00000010-0x0000001f 64bit pref] conflicts with reserved [mem 0x00000000-0x0000ffff] [ 5.037178] pci 0000:7f:1e.3: BAR 0: can't assign mem pref (size 0x10) [ 5.037187] pci 0000:00:01.0: BAR 15: assigned [mem 0x90000000-0x900fffff 64bit pref] [ 5.037195] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037204] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037212] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037220] pci 0000:01:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037229] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037237] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037245] pci 0000:01:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037253] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037262] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037270] pci 0000:01:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037278] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037286] pci 0000:01:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037288] pci 0000:01:00.0: BAR 7: assigned [mem 0x90000000-0x9001ffff 64bit pref] [ 5.037293] pci 0000:01:00.0: BAR 7: set to [mem 0x90000000-0x9001ffff 64bit pref] (PCI address [0x90000000-0x9001ffff]) [ 5.037301] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037309] pci 0000:01:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037311] pci 0000:01:00.0: BAR 10: assigned [mem 0x90020000-0x9003ffff 64bit pref] [ 5.037315] pci 0000:01:00.0: BAR 10: set to [mem 0x90020000-0x9003ffff 64bit pref] (PCI address [0x90020000-0x9003ffff]) [ 5.037324] pci 0000:01:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037332] pci 0000:01:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037334] pci 0000:01:00.1: BAR 7: assigned [mem 0x90040000-0x9005ffff 64bit pref] [ 5.037338] pci 0000:01:00.1: BAR 7: set to [mem 0x90040000-0x9005ffff 64bit pref] (PCI address [0x90040000-0x9005ffff]) [ 5.037346] pci 0000:01:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037355] pci 0000:01:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 5.037357] pci 0000:01:00.1: BAR 10: assigned [mem 0x90060000-0x9007ffff 64bit pref] [ 5.037361] pci 0000:01:00.1: BAR 10: set to [mem 0x90060000-0x9007ffff 64bit pref] (PCI address [0x90060000-0x9007ffff]) [ 5.037362] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 5.037364] pci 0000:00:01.0: bridge window [io 0x8000-0x8fff] [ 5.037367] pci 0000:00:01.0: bridge window [mem 0xc7700000-0xc77fffff] [ 5.037369] pci 0000:00:01.0: bridge window [mem 0x90000000-0x900fffff 64bit pref] [ 5.037372] pci 0000:00:02.0: PCI bridge to [bus 02-02] [ 5.037373] pci 0000:00:02.0: bridge window [io disabled] [ 5.037375] pci 0000:00:02.0: bridge window [mem disabled] [ 5.037377] pci 0000:00:02.0: bridge window [mem pref disabled] [ 5.037382] pci 0000:04:05.0: BAR 15: can't assign mem pref (size 0x200000) [ 5.037383] pci 0000:04:01.0: BAR 14: can't assign mem (size 0x200000) [ 5.037385] pci 0000:04:01.0: BAR 15: can't assign mem pref (size 0x200000) [ 5.037386] pci 0000:04:01.0: BAR 13: can't assign io (size 0x1000) [ 5.037387] pci 0000:04:01.0: PCI bridge to [bus 05-05] [ 5.037388] pci 0000:04:01.0: bridge window [io disabled] [ 5.037391] pci 0000:04:01.0: bridge window [mem disabled] [ 5.037394] pci 0000:04:01.0: bridge window [mem pref disabled] [ 5.037398] pci 0000:04:02.0: PCI bridge to [bus 06-06] [ 5.037399] pci 0000:04:02.0: bridge window [io disabled] [ 5.037402] pci 0000:04:02.0: bridge window [mem disabled] [ 5.037404] pci 0000:04:02.0: bridge window [mem pref disabled] [ 5.037408] pci 0000:04:03.0: PCI bridge to [bus 07-07] [ 5.037409] pci 0000:04:03.0: bridge window [io disabled] [ 5.037412] pci 0000:04:03.0: bridge window [mem disabled] [ 5.037415] pci 0000:04:03.0: bridge window [mem pref disabled] [ 5.037420] pci 0000:09:02.0: PCI bridge to [bus 0a-0a] [ 5.037421] pci 0000:09:02.0: bridge window [io disabled] [ 5.037427] pci 0000:09:02.0: bridge window [mem disabled] [ 5.037432] pci 0000:09:02.0: bridge window [mem pref disabled] [ 5.037440] pci 0000:09:03.0: PCI bridge to [bus 0b-0b] [ 5.037441] pci 0000:09:03.0: bridge window [io disabled] [ 5.037448] pci 0000:09:03.0: bridge window [mem disabled] [ 5.037452] pci 0000:09:03.0: bridge window [mem pref disabled] [ 5.037461] pci 0000:09:04.0: PCI bridge to [bus 0c-0c] [ 5.037462] pci 0000:09:04.0: bridge window [io disabled] [ 5.037468] pci 0000:09:04.0: bridge window [mem disabled] [ 5.037473] pci 0000:09:04.0: bridge window [mem pref disabled] [ 5.037482] pci 0000:09:06.0: PCI bridge to [bus 0d-0d] [ 5.037483] pci 0000:09:06.0: bridge window [io disabled] [ 5.037489] pci 0000:09:06.0: bridge window [mem disabled] [ 5.037494] pci 0000:09:06.0: bridge window [mem pref disabled] [ 5.037502] pci 0000:09:07.0: PCI bridge to [bus 0e-0e] [ 5.037503] pci 0000:09:07.0: bridge window [io disabled] [ 5.037510] pci 0000:09:07.0: bridge window [mem disabled] [ 5.037514] pci 0000:09:07.0: bridge window [mem pref disabled] [ 5.037523] pci 0000:09:08.0: PCI bridge to [bus 0f-0f] [ 5.037524] pci 0000:09:08.0: bridge window [io disabled] [ 5.037530] pci 0000:09:08.0: bridge window [mem disabled] [ 5.037535] pci 0000:09:08.0: bridge window [mem pref disabled] [ 5.037544] pci 0000:09:0a.0: PCI bridge to [bus 10-10] [ 5.037545] pci 0000:09:0a.0: bridge window [io disabled] [ 5.037551] pci 0000:09:0a.0: bridge window [mem disabled] [ 5.037556] pci 0000:09:0a.0: bridge window [mem pref disabled] [ 5.037565] pci 0000:09:0b.0: PCI bridge to [bus 11-11] [ 5.037566] pci 0000:09:0b.0: bridge window [io disabled] [ 5.037572] pci 0000:09:0b.0: bridge window [mem disabled] [ 5.037577] pci 0000:09:0b.0: bridge window [mem pref disabled] [ 5.037585] pci 0000:08:00.0: PCI bridge to [bus 09-11] [ 5.037586] pci 0000:08:00.0: bridge window [io disabled] [ 5.037593] pci 0000:08:00.0: bridge window [mem disabled] [ 5.037598] pci 0000:08:00.0: bridge window [mem pref disabled] [ 5.037606] pci 0000:04:04.0: PCI bridge to [bus 08-11] [ 5.037607] pci 0000:04:04.0: bridge window [io disabled] [ 5.037610] pci 0000:04:04.0: bridge window [mem disabled] [ 5.037612] pci 0000:04:04.0: bridge window [mem pref disabled] [ 5.037618] pci 0000:14:00.0: PCI bridge to [bus 15-15] [ 5.037621] pci 0000:14:00.0: bridge window [io 0x6000-0x6fff] [ 5.037628] pci 0000:14:00.0: bridge window [mem disabled] [ 5.037633] pci 0000:14:00.0: bridge window [mem pref disabled] [ 5.037642] pci 0000:13:02.0: PCI bridge to [bus 14-15] [ 5.037645] pci 0000:13:02.0: bridge window [io 0x6000-0x6fff] [ 5.037651] pci 0000:13:02.0: bridge window [mem disabled] [ 5.037656] pci 0000:13:02.0: bridge window [mem pref disabled] [ 5.037664] pci 0000:16:00.0: PCI bridge to [bus 17-17] [ 5.037667] pci 0000:16:00.0: bridge window [io 0x5000-0x5fff] [ 5.037674] pci 0000:16:00.0: bridge window [mem disabled] [ 5.037679] pci 0000:16:00.0: bridge window [mem pref disabled] [ 5.037688] pci 0000:13:03.0: PCI bridge to [bus 16-17] [ 5.037691] pci 0000:13:03.0: bridge window [io 0x5000-0x5fff] [ 5.037697] pci 0000:13:03.0: bridge window [mem disabled] [ 5.037702] pci 0000:13:03.0: bridge window [mem pref disabled] [ 5.037711] pci 0000:18:00.0: PCI bridge to [bus 19-19] [ 5.037712] pci 0000:18:00.0: bridge window [io disabled] [ 5.037720] pci 0000:18:00.0: bridge window [mem 0xc7500000-0xc75fffff] [ 5.037725] pci 0000:18:00.0: bridge window [mem pref disabled] [ 5.037735] pci 0000:13:04.0: PCI bridge to [bus 18-19] [ 5.037736] pci 0000:13:04.0: bridge window [io disabled] [ 5.037743] pci 0000:13:04.0: bridge window [mem 0xc7500000-0xc75fffff] [ 5.037748] pci 0000:13:04.0: bridge window [mem pref disabled] [ 5.037757] pci 0000:1a:00.0: PCI bridge to [bus 1b-1b] [ 5.037757] pci 0000:1a:00.0: bridge window [io disabled] [ 5.037765] pci 0000:1a:00.0: bridge window [mem 0xc7400000-0xc74fffff] [ 5.037771] pci 0000:1a:00.0: bridge window [mem pref disabled] [ 5.037781] pci 0000:13:06.0: PCI bridge to [bus 1a-1b] [ 5.037782] pci 0000:13:06.0: bridge window [io disabled] [ 5.037789] pci 0000:13:06.0: bridge window [mem 0xc7400000-0xc74fffff] [ 5.037793] pci 0000:13:06.0: bridge window [mem pref disabled] [ 5.037802] pci 0000:1c:00.0: PCI bridge to [bus 1d-1d] [ 5.037805] pci 0000:1c:00.0: bridge window [io 0x4000-0x4fff] [ 5.037812] pci 0000:1c:00.0: bridge window [mem disabled] [ 5.037817] pci 0000:1c:00.0: bridge window [mem pref disabled] [ 5.037826] pci 0000:13:07.0: PCI bridge to [bus 1c-1d] [ 5.037829] pci 0000:13:07.0: bridge window [io 0x4000-0x4fff] [ 5.037836] pci 0000:13:07.0: bridge window [mem disabled] [ 5.037840] pci 0000:13:07.0: bridge window [mem pref disabled] [ 5.037849] pci 0000:1e:00.0: PCI bridge to [bus 1f-1f] [ 5.037853] pci 0000:1e:00.0: bridge window [io 0x3000-0x3fff] [ 5.037860] pci 0000:1e:00.0: bridge window [mem 0xc7300000-0xc73fffff] [ 5.037866] pci 0000:1e:00.0: bridge window [mem pref disabled] [ 5.037876] pci 0000:13:08.0: PCI bridge to [bus 1e-1f] [ 5.037879] pci 0000:13:08.0: bridge window [io 0x3000-0x3fff] [ 5.037885] pci 0000:13:08.0: bridge window [mem 0xc7300000-0xc73fffff] [ 5.037890] pci 0000:13:08.0: bridge window [mem pref disabled] [ 5.037899] pci 0000:20:00.0: PCI bridge to [bus 21-21] [ 5.037902] pci 0000:20:00.0: bridge window [io 0x2000-0x2fff] [ 5.037910] pci 0000:20:00.0: bridge window [mem 0xc7200000-0xc72fffff] [ 5.037916] pci 0000:20:00.0: bridge window [mem pref disabled] [ 5.037926] pci 0000:13:0a.0: PCI bridge to [bus 20-21] [ 5.037929] pci 0000:13:0a.0: bridge window [io 0x2000-0x2fff] [ 5.037935] pci 0000:13:0a.0: bridge window [mem 0xc7200000-0xc72fffff] [ 5.037940] pci 0000:13:0a.0: bridge window [mem pref disabled] [ 5.037948] pci 0000:22:00.0: PCI bridge to [bus 23-23] [ 5.037952] pci 0000:22:00.0: bridge window [io 0x1000-0x1fff] [ 5.037960] pci 0000:22:00.0: bridge window [mem 0xc7100000-0xc71fffff] [ 5.037965] pci 0000:22:00.0: bridge window [mem pref disabled] [ 5.037975] pci 0000:13:0b.0: PCI bridge to [bus 22-23] [ 5.037978] pci 0000:13:0b.0: bridge window [io 0x1000-0x1fff] [ 5.037985] pci 0000:13:0b.0: bridge window [mem 0xc7100000-0xc71fffff] [ 5.037989] pci 0000:13:0b.0: bridge window [mem pref disabled] [ 5.037998] pci 0000:12:00.0: PCI bridge to [bus 13-23] [ 5.038001] pci 0000:12:00.0: bridge window [io 0x1000-0x6fff] [ 5.038007] pci 0000:12:00.0: bridge window [mem 0xc7100000-0xc75fffff] [ 5.038012] pci 0000:12:00.0: bridge window [mem pref disabled] [ 5.038021] pci 0000:04:05.0: PCI bridge to [bus 12-23] [ 5.038023] pci 0000:04:05.0: bridge window [io 0x1000-0x6fff] [ 5.038026] pci 0000:04:05.0: bridge window [mem 0xc7100000-0xc75fffff] [ 5.038028] pci 0000:04:05.0: bridge window [mem pref disabled] [ 5.038032] pci 0000:03:00.0: PCI bridge to [bus 04-23] [ 5.038034] pci 0000:03:00.0: bridge window [io 0x1000-0x6fff] [ 5.038037] pci 0000:03:00.0: bridge window [mem 0xc7100000-0xc75fffff] [ 5.038040] pci 0000:03:00.0: bridge window [mem pref disabled] [ 5.038044] pci 0000:00:02.2: PCI bridge to [bus 03-23] [ 5.038045] pci 0000:00:02.2: bridge window [io 0x1000-0x6fff] [ 5.038048] pci 0000:00:02.2: bridge window [mem 0xc7100000-0xc76fffff] [ 5.038050] pci 0000:00:02.2: bridge window [mem pref disabled] [ 5.038053] pci 0000:00:03.0: PCI bridge to [bus 24-24] [ 5.038054] pci 0000:00:03.0: bridge window [io disabled] [ 5.038056] pci 0000:00:03.0: bridge window [mem disabled] [ 5.038058] pci 0000:00:03.0: bridge window [mem pref disabled] [ 5.038061] pci 0000:00:1c.0: PCI bridge to [bus 25-25] [ 5.038062] pci 0000:00:1c.0: bridge window [io disabled] [ 5.038065] pci 0000:00:1c.0: bridge window [mem disabled] [ 5.038074] pci 0000:00:1c.0: bridge window [mem pref disabled] [ 5.038082] pci 0000:26:00.0: PCI bridge to [bus 27-27] [ 5.038086] pci 0000:26:00.0: bridge window [io 0x7000-0x7fff] [ 5.038094] pci 0000:26:00.0: bridge window [mem 0xc6000000-0xc70fffff] [ 5.038099] pci 0000:26:00.0: bridge window [mem pref disabled] [ 5.038110] pci 0000:00:1c.4: PCI bridge to [bus 26-27] [ 5.038112] pci 0000:00:1c.4: bridge window [io 0x7000-0x7fff] [ 5.038117] pci 0000:00:1c.4: bridge window [mem 0xc6000000-0xc70fffff] [ 5.038121] pci 0000:00:1c.4: bridge window [mem pref disabled] [ 5.038131] pci 0000:80:02.0: PCI bridge to [bus 81-81] [ 5.038132] pci 0000:80:02.0: bridge window [io disabled] [ 5.038135] pci 0000:80:02.0: bridge window [mem disabled] [ 5.038137] pci 0000:80:02.0: bridge window [mem pref disabled] [ 5.038140] pci 0000:80:02.2: PCI bridge to [bus 82-82] [ 5.038141] pci 0000:80:02.2: bridge window [io disabled] [ 5.038144] pci 0000:80:02.2: bridge window [mem 0xf8100000-0xf81fffff] [ 5.038146] pci 0000:80:02.2: bridge window [mem pref disabled] [ 5.038149] pci 0000:80:03.0: PCI bridge to [bus 83-83] [ 5.038150] pci 0000:80:03.0: bridge window [io disabled] [ 5.038152] pci 0000:80:03.0: bridge window [mem disabled] [ 5.038154] pci 0000:80:03.0: bridge window [mem pref disabled] [ 5.038158] pci 0000:84:00.0: PCI bridge to [bus 85-85] [ 5.038159] pci 0000:84:00.0: bridge window [io 0xf000-0xffff] [ 5.038162] pci 0000:84:00.0: bridge window [mem 0xf0000000-0xf80fffff] [ 5.038165] pci 0000:84:00.0: bridge window [mem pref disabled] [ 5.038169] pci 0000:80:03.2: PCI bridge to [bus 84-85] [ 5.038170] pci 0000:80:03.2: bridge window [io 0xf000-0xffff] [ 5.038173] pci 0000:80:03.2: bridge window [mem 0xf0000000-0xf80fffff] [ 5.038175] pci 0000:80:03.2: bridge window [mem pref disabled] [ 5.038201] pci 0000:00:01.0: PCI INT A -> GSI 27 (level, low) -> IRQ 27 [ 5.038204] pci 0000:00:01.0: setting latency timer to 64 [ 5.038225] pci 0000:00:02.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 5.038227] pci 0000:00:02.0: setting latency timer to 64 [ 5.038231] pci 0000:00:02.2: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 5.038233] pci 0000:00:02.2: setting latency timer to 64 [ 5.038241] pci 0000:03:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 5.038243] pci 0000:03:00.0: setting latency timer to 64 [ 5.038252] pci 0000:04:01.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 5.038254] pci 0000:04:01.0: setting latency timer to 64 [ 5.038262] pci 0000:04:02.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 5.038265] pci 0000:04:02.0: setting latency timer to 64 [ 5.038273] pci 0000:04:03.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 5.038275] pci 0000:04:03.0: setting latency timer to 64 [ 5.038280] pci 0000:04:04.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 5.038282] pci 0000:04:04.0: setting latency timer to 64 [ 5.038291] pci 0000:08:00.0: setting latency timer to 64 [ 5.038301] pci 0000:09:02.0: setting latency timer to 64 [ 5.038311] pci 0000:09:03.0: setting latency timer to 64 [ 5.038320] pci 0000:09:04.0: setting latency timer to 64 [ 5.038330] pci 0000:09:06.0: setting latency timer to 64 [ 5.038340] pci 0000:09:07.0: setting latency timer to 64 [ 5.038354] pci 0000:09:08.0: setting latency timer to 64 [ 5.038364] pci 0000:09:0a.0: setting latency timer to 64 [ 5.038374] pci 0000:09:0b.0: setting latency timer to 64 [ 5.038380] pci 0000:04:05.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 5.038383] pci 0000:04:05.0: setting latency timer to 64 [ 5.038392] pci 0000:12:00.0: setting latency timer to 64 [ 5.038401] pci 0000:13:02.0: setting latency timer to 64 [ 5.038413] pci 0000:14:00.0: setting latency timer to 64 [ 5.038423] pci 0000:13:03.0: setting latency timer to 64 [ 5.038434] pci 0000:16:00.0: setting latency timer to 64 [ 5.038444] pci 0000:13:04.0: setting latency timer to 64 [ 5.038455] pci 0000:18:00.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 5.038460] pci 0000:18:00.0: setting latency timer to 64 [ 5.038471] pci 0000:13:06.0: setting latency timer to 64 [ 5.038482] pci 0000:1a:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 5.038487] pci 0000:1a:00.0: setting latency timer to 64 [ 5.038498] pci 0000:13:07.0: setting latency timer to 64 [ 5.038509] pci 0000:1c:00.0: setting latency timer to 64 [ 5.038519] pci 0000:13:08.0: setting latency timer to 64 [ 5.038530] pci 0000:1e:00.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 5.038536] pci 0000:1e:00.0: setting latency timer to 64 [ 5.038546] pci 0000:13:0a.0: setting latency timer to 64 [ 5.038557] pci 0000:20:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 5.038562] pci 0000:20:00.0: setting latency timer to 64 [ 5.038572] pci 0000:13:0b.0: setting latency timer to 64 [ 5.038583] pci 0000:22:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 5.038589] pci 0000:22:00.0: setting latency timer to 64 [ 5.038598] pci 0000:00:03.0: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 5.038600] pci 0000:00:03.0: setting latency timer to 64 [ 5.038608] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 5.038612] pci 0000:00:1c.0: setting latency timer to 64 [ 5.038618] pci 0000:00:1c.4: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 5.038623] pci 0000:00:1c.4: setting latency timer to 64 [ 5.038635] pci 0000:26:00.0: setting latency timer to 64 [ 5.038644] pci 0000:80:02.0: PCI INT A -> GSI 56 (level, low) -> IRQ 56 [ 5.038647] pci 0000:80:02.0: setting latency timer to 64 [ 5.038651] pci 0000:80:02.2: PCI INT A -> GSI 56 (level, low) -> IRQ 56 [ 5.038653] pci 0000:80:02.2: setting latency timer to 64 [ 5.038677] pci 0000:80:03.0: PCI INT A -> GSI 64 (level, low) -> IRQ 64 [ 5.038679] pci 0000:80:03.0: setting latency timer to 64 [ 5.038684] pci 0000:80:03.2: PCI INT A -> GSI 64 (level, low) -> IRQ 64 [ 5.038686] pci 0000:80:03.2: setting latency timer to 64 [ 5.038691] pci 0000:84:00.0: setting latency timer to 64 [ 5.038697] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 5.038698] pci_bus 0000:00: resource 5 [io 0x1000-0x9fff] [ 5.038699] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 5.038700] pci_bus 0000:00: resource 7 [mem 0xfedb0000-0xfedb000f] [ 5.038702] pci_bus 0000:00: resource 8 [mem 0xfedc0000-0xfedc000f] [ 5.038703] pci_bus 0000:00: resource 9 [mem 0x90000000-0xc7ffbfff] [ 5.038704] pci_bus 0000:01: resource 0 [io 0x8000-0x8fff] [ 5.038705] pci_bus 0000:01: resource 1 [mem 0xc7700000-0xc77fffff] [ 5.038706] pci_bus 0000:01: resource 2 [mem 0x90000000-0x900fffff 64bit pref] [ 5.038708] pci_bus 0000:03: resource 0 [io 0x1000-0x6fff] [ 5.038709] pci_bus 0000:03: resource 1 [mem 0xc7100000-0xc76fffff] [ 5.038710] pci_bus 0000:04: resource 0 [io 0x1000-0x6fff] [ 5.038711] pci_bus 0000:04: resource 1 [mem 0xc7100000-0xc75fffff] [ 5.038713] pci_bus 0000:12: resource 0 [io 0x1000-0x6fff] [ 5.038714] pci_bus 0000:12: resource 1 [mem 0xc7100000-0xc75fffff] [ 5.038715] pci_bus 0000:13: resource 0 [io 0x1000-0x6fff] [ 5.038716] pci_bus 0000:13: resource 1 [mem 0xc7100000-0xc75fffff] [ 5.038718] pci_bus 0000:14: resource 0 [io 0x6000-0x6fff] [ 5.038719] pci_bus 0000:15: resource 0 [io 0x6000-0x6fff] [ 5.038720] pci_bus 0000:16: resource 0 [io 0x5000-0x5fff] [ 5.038721] pci_bus 0000:17: resource 0 [io 0x5000-0x5fff] [ 5.038722] pci_bus 0000:18: resource 1 [mem 0xc7500000-0xc75fffff] [ 5.038723] pci_bus 0000:19: resource 1 [mem 0xc7500000-0xc75fffff] [ 5.038725] pci_bus 0000:1a: resource 1 [mem 0xc7400000-0xc74fffff] [ 5.038726] pci_bus 0000:1b: resource 1 [mem 0xc7400000-0xc74fffff] [ 5.038727] pci_bus 0000:1c: resource 0 [io 0x4000-0x4fff] [ 5.038728] pci_bus 0000:1d: resource 0 [io 0x4000-0x4fff] [ 5.038730] pci_bus 0000:1e: resource 0 [io 0x3000-0x3fff] [ 5.038731] pci_bus 0000:1e: resource 1 [mem 0xc7300000-0xc73fffff] [ 5.038732] pci_bus 0000:1f: resource 0 [io 0x3000-0x3fff] [ 5.038733] pci_bus 0000:1f: resource 1 [mem 0xc7300000-0xc73fffff] [ 5.038734] pci_bus 0000:20: resource 0 [io 0x2000-0x2fff] [ 5.038735] pci_bus 0000:20: resource 1 [mem 0xc7200000-0xc72fffff] [ 5.038736] pci_bus 0000:21: resource 0 [io 0x2000-0x2fff] [ 5.038738] pci_bus 0000:21: resource 1 [mem 0xc7200000-0xc72fffff] [ 5.038739] pci_bus 0000:22: resource 0 [io 0x1000-0x1fff] [ 5.038740] pci_bus 0000:22: resource 1 [mem 0xc7100000-0xc71fffff] [ 5.038741] pci_bus 0000:23: resource 0 [io 0x1000-0x1fff] [ 5.038742] pci_bus 0000:23: resource 1 [mem 0xc7100000-0xc71fffff] [ 5.038744] pci_bus 0000:26: resource 0 [io 0x7000-0x7fff] [ 5.038745] pci_bus 0000:26: resource 1 [mem 0xc6000000-0xc70fffff] [ 5.038746] pci_bus 0000:27: resource 0 [io 0x7000-0x7fff] [ 5.038747] pci_bus 0000:27: resource 1 [mem 0xc6000000-0xc70fffff] [ 5.038749] pci_bus 0000:80: resource 4 [io 0xa000-0xffff] [ 5.038750] pci_bus 0000:80: resource 5 [mem 0xc8000000-0xfbffbfff] [ 5.038751] pci_bus 0000:82: resource 1 [mem 0xf8100000-0xf81fffff] [ 5.038753] pci_bus 0000:84: resource 0 [io 0xf000-0xffff] [ 5.038754] pci_bus 0000:84: resource 1 [mem 0xf0000000-0xf80fffff] [ 5.038755] pci_bus 0000:85: resource 0 [io 0xf000-0xffff] [ 5.038756] pci_bus 0000:85: resource 1 [mem 0xf0000000-0xf80fffff] [ 5.038799] NET: Registered protocol family 2 [ 5.039171] IP route cache hash table entries: 524288 (order: 10, 4194304 bytes) [ 5.040886] TCP established hash table entries: 524288 (order: 11, 8388608 bytes) [ 5.043381] TCP bind hash table entries: 65536 (order: 8, 1048576 bytes) [ 5.043687] TCP: Hash tables configured (established 524288 bind 65536) [ 5.043688] TCP reno registered [ 5.043734] UDP hash table entries: 16384 (order: 7, 524288 bytes) [ 5.043919] UDP-Lite hash table entries: 16384 (order: 7, 524288 bytes) [ 5.044178] NET: Registered protocol family 1 [ 5.135992] RPC: Registered named UNIX socket transport module. [ 5.136340] RPC: Registered udp transport module. [ 5.136675] RPC: Registered tcp transport module. [ 5.137011] RPC: Registered tcp NFSv4.1 backchannel transport module. [ 5.137535] pci 0000:00:1a.0: EHCI: BIOS handoff [ 5.148160] pci 0000:00:1d.0: EHCI: BIOS handoff [ 5.159193] pci 0000:14:00.0: TI XIO2000a quirk detected; secondary bus fast back-to-back transfers disabled [ 5.159815] pci 0000:16:00.0: TI XIO2000a quirk detected; secondary bus fast back-to-back transfers disabled [ 5.160486] pci 0000:27:00.0: Boot video device [ 5.160505] PCI: CLS 64 bytes, default 64 [ 5.160539] PCI-DMA: Using software bounce buffering for IO (SWIOTLB) [ 5.160879] Placing 64MB software IO TLB between ffff8800750c3000 - ffff8800790c3000 [ 5.161492] software IO TLB at phys 0x750c3000 - 0x790c3000 [ 5.248537] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 5.252218] VFS: Disk quotas dquot_6.5.2 [ 5.252617] Dquot-cache hash table entries: 512 (order 0, 4096 bytes) [ 5.253704] Installing knfsd (copyright (C) 1996 okir@monad.swb.de). [ 5.254551] msgmni has been set to 32768 [ 5.255294] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 5.255900] io scheduler noop registered [ 5.256249] io scheduler deadline registered [ 5.256633] io scheduler cfq registered (default) [ 5.257355] pcieport 0000:00:01.0: setting latency timer to 64 [ 5.257379] pcieport 0000:00:01.0: irq 88 for MSI/MSI-X [ 5.257438] pcieport 0000:00:02.0: setting latency timer to 64 [ 5.257455] pcieport 0000:00:02.0: irq 89 for MSI/MSI-X [ 5.257513] pcieport 0000:00:02.2: setting latency timer to 64 [ 5.257530] pcieport 0000:00:02.2: irq 90 for MSI/MSI-X [ 5.257614] pcieport 0000:00:03.0: setting latency timer to 64 [ 5.257631] pcieport 0000:00:03.0: irq 91 for MSI/MSI-X [ 5.257688] pcieport 0000:00:1c.0: setting latency timer to 64 [ 5.257717] pcieport 0000:00:1c.0: irq 92 for MSI/MSI-X [ 5.257792] pcieport 0000:00:1c.4: setting latency timer to 64 [ 5.257820] pcieport 0000:00:1c.4: irq 93 for MSI/MSI-X [ 5.257895] pcieport 0000:03:00.0: setting latency timer to 64 [ 5.257924] pcieport 0000:03:00.0: irq 94 for MSI/MSI-X [ 5.258029] pcieport 0000:04:01.0: setting latency timer to 64 [ 5.258057] pcieport 0000:04:01.0: irq 95 for MSI/MSI-X [ 5.258166] pcieport 0000:04:02.0: setting latency timer to 64 [ 5.258195] pcieport 0000:04:02.0: irq 96 for MSI/MSI-X [ 5.258267] pcieport 0000:04:03.0: setting latency timer to 64 [ 5.258296] pcieport 0000:04:03.0: irq 97 for MSI/MSI-X [ 5.258368] pcieport 0000:04:04.0: setting latency timer to 64 [ 5.258397] pcieport 0000:04:04.0: irq 98 for MSI/MSI-X [ 5.258471] pcieport 0000:04:05.0: setting latency timer to 64 [ 5.258500] pcieport 0000:04:05.0: irq 99 for MSI/MSI-X [ 5.258606] pcieport 0000:08:00.0: setting latency timer to 64 [ 5.258768] pcieport 0000:09:02.0: setting latency timer to 64 [ 5.258837] pcieport 0000:09:02.0: irq 100 for MSI/MSI-X [ 5.258937] pcieport 0000:09:03.0: setting latency timer to 64 [ 5.259012] pcieport 0000:09:03.0: irq 101 for MSI/MSI-X [ 5.259109] pcieport 0000:09:04.0: setting latency timer to 64 [ 5.259178] pcieport 0000:09:04.0: irq 102 for MSI/MSI-X [ 5.259295] pcieport 0000:09:06.0: setting latency timer to 64 [ 5.259365] pcieport 0000:09:06.0: irq 103 for MSI/MSI-X [ 5.259461] pcieport 0000:09:07.0: setting latency timer to 64 [ 5.259531] pcieport 0000:09:07.0: irq 104 for MSI/MSI-X [ 5.259627] pcieport 0000:09:08.0: setting latency timer to 64 [ 5.259696] pcieport 0000:09:08.0: irq 105 for MSI/MSI-X [ 5.259795] pcieport 0000:09:0a.0: setting latency timer to 64 [ 5.259864] pcieport 0000:09:0a.0: irq 106 for MSI/MSI-X [ 5.259969] pcieport 0000:09:0b.0: setting latency timer to 64 [ 5.260054] pcieport 0000:09:0b.0: irq 107 for MSI/MSI-X [ 5.260192] pcieport 0000:12:00.0: setting latency timer to 64 [ 5.260328] pcieport 0000:13:02.0: setting latency timer to 64 [ 5.260399] pcieport 0000:13:02.0: irq 108 for MSI/MSI-X [ 5.260496] pcieport 0000:13:03.0: setting latency timer to 64 [ 5.260565] pcieport 0000:13:03.0: irq 109 for MSI/MSI-X [ 5.260667] pcieport 0000:13:04.0: setting latency timer to 64 [ 5.260735] pcieport 0000:13:04.0: irq 110 for MSI/MSI-X [ 5.260835] pcieport 0000:13:06.0: setting latency timer to 64 [ 5.260903] pcieport 0000:13:06.0: irq 111 for MSI/MSI-X [ 5.261018] pcieport 0000:13:07.0: setting latency timer to 64 [ 5.261087] pcieport 0000:13:07.0: irq 112 for MSI/MSI-X [ 5.261188] pcieport 0000:13:08.0: setting latency timer to 64 [ 5.261256] pcieport 0000:13:08.0: irq 113 for MSI/MSI-X [ 5.261357] pcieport 0000:13:0a.0: setting latency timer to 64 [ 5.261425] pcieport 0000:13:0a.0: irq 114 for MSI/MSI-X [ 5.261532] pcieport 0000:13:0b.0: setting latency timer to 64 [ 5.261600] pcieport 0000:13:0b.0: irq 115 for MSI/MSI-X [ 5.261737] pcieport 0000:80:02.0: setting latency timer to 64 [ 5.261756] pcieport 0000:80:02.0: irq 116 for MSI/MSI-X [ 5.261818] pcieport 0000:80:02.2: setting latency timer to 64 [ 5.261838] pcieport 0000:80:02.2: irq 117 for MSI/MSI-X [ 5.261899] pcieport 0000:80:03.0: setting latency timer to 64 [ 5.261918] pcieport 0000:80:03.0: irq 118 for MSI/MSI-X [ 5.261980] pcieport 0000:80:03.2: setting latency timer to 64 [ 5.262009] pcieport 0000:80:03.2: irq 119 for MSI/MSI-X [ 5.262430] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input0 [ 5.263052] ACPI: Power Button [PWRB] [ 5.263446] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input1 [ 5.264061] ACPI: Power Button [PWRF] [ 5.264563] ACPI: acpi_idle registered with cpuidle [ 5.270770] Serial: 8250/16550 driver, 4 ports, IRQ sharing enabled [ 5.332626] Non-volatile memory driver v1.3 [ 5.332980] Linux agpgart interface v0.103 [ 5.333561] [drm] Initialized drm 1.1.0 20060810 [ 5.333908] [drm:i915_init] *ERROR* drm/i915 can't work without intel_agp module! [ 5.336415] brd: module loaded [ 5.337536] loop: module loaded [ 5.338661] e1000: Intel(R) PRO/1000 Network Driver - version 7.3.21-k8-NAPI [ 5.339021] e1000: Copyright (c) 1999-2006 Intel Corporation. [ 5.339433] e1000e: Intel(R) PRO/1000 Network Driver - 1.3.10-k2 [ 5.339782] e1000e: Copyright(c) 1999 - 2011 Intel Corporation. [ 5.340203] Intel(R) Gigabit Ethernet Network Driver - version 3.0.6-k2 [ 5.340554] Copyright (c) 2007-2011 Intel Corporation. [ 5.340965] igb 0000:01:00.0: PCI INT A -> GSI 26 (level, low) -> IRQ 26 [ 5.341324] igb 0000:01:00.0: setting latency timer to 64 [ 5.341564] igb 0000:01:00.0: irq 120 for MSI/MSI-X [ 5.341568] igb 0000:01:00.0: irq 121 for MSI/MSI-X [ 5.341571] igb 0000:01:00.0: irq 122 for MSI/MSI-X [ 5.341575] igb 0000:01:00.0: irq 123 for MSI/MSI-X [ 5.341578] igb 0000:01:00.0: irq 124 for MSI/MSI-X [ 5.341581] igb 0000:01:00.0: irq 125 for MSI/MSI-X [ 5.341586] igb 0000:01:00.0: irq 126 for MSI/MSI-X [ 5.341590] igb 0000:01:00.0: irq 127 for MSI/MSI-X [ 5.341604] igb 0000:01:00.0: irq 128 for MSI/MSI-X [ 5.341621] igb 0000:01:00.0: 0 vfs allocated [ 5.393520] igb 0000:01:00.0: Intel(R) Gigabit Ethernet Network Connection [ 5.393880] igb 0000:01:00.0: eth0: (PCIe:5.0Gb/s:Width x4) 0c:c4:7a:6c:16:f2 [ 5.394305] igb 0000:01:00.0: eth0: PBA No: 070C00-000 [ 5.394654] igb 0000:01:00.0: Using MSI-X interrupts. 8 rx queue(s), 8 tx queue(s) [ 5.395312] igb 0000:01:00.1: PCI INT B -> GSI 28 (level, low) -> IRQ 28 [ 5.395678] igb 0000:01:00.1: setting latency timer to 64 [ 5.395899] igb 0000:01:00.1: irq 129 for MSI/MSI-X [ 5.395902] igb 0000:01:00.1: irq 130 for MSI/MSI-X [ 5.395906] igb 0000:01:00.1: irq 131 for MSI/MSI-X [ 5.395909] igb 0000:01:00.1: irq 132 for MSI/MSI-X [ 5.395913] igb 0000:01:00.1: irq 133 for MSI/MSI-X [ 5.395916] igb 0000:01:00.1: irq 134 for MSI/MSI-X [ 5.395920] igb 0000:01:00.1: irq 135 for MSI/MSI-X [ 5.395924] igb 0000:01:00.1: irq 136 for MSI/MSI-X [ 5.395927] igb 0000:01:00.1: irq 137 for MSI/MSI-X [ 5.395942] igb 0000:01:00.1: 0 vfs allocated [ 5.448714] igb 0000:01:00.1: Intel(R) Gigabit Ethernet Network Connection [ 5.449077] igb 0000:01:00.1: eth1: (PCIe:5.0Gb/s:Width x4) 0c:c4:7a:6c:16:f3 [ 5.449503] igb 0000:01:00.1: eth1: PBA No: 070C00-000 [ 5.449857] igb 0000:01:00.1: Using MSI-X interrupts. 8 rx queue(s), 8 tx queue(s) [ 5.450544] e100: Intel(R) PRO/100 Network Driver, 3.5.24-k2-NAPI [ 5.450904] e100: Copyright(c) 1999-2006 Intel Corporation [ 5.451394] sky2: driver version 1.28 [ 5.451942] console [netcon0] enabled [ 5.452289] netconsole: network logging started [ 5.452829] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 5.453183] ehci_hcd: block sizes: qh 112 qtd 96 itd 192 sitd 96 [ 5.453214] ehci_hcd 0000:00:1a.0: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 5.453579] ehci_hcd 0000:00:1a.0: setting latency timer to 64 [ 5.453582] ehci_hcd 0000:00:1a.0: EHCI Host Controller [ 5.453950] drivers/usb/core/inode.c: creating file 'devices' [ 5.453964] drivers/usb/core/inode.c: creating file '001' [ 5.454024] ehci_hcd 0000:00:1a.0: new USB bus registered, assigned bus number 1 [ 5.454660] ehci_hcd 0000:00:1a.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 5.454663] ehci_hcd 0000:00:1a.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 5.454678] ehci_hcd 0000:00:1a.0: support lpm [ 5.454687] ehci_hcd 0000:00:1a.0: debug port 2 [ 5.455045] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 5.458926] ehci_hcd 0000:00:1a.0: cache line size of 64 is not supported [ 5.458928] ehci_hcd 0000:00:1a.0: supports USB remote wakeup [ 5.458941] ehci_hcd 0000:00:1a.0: irq 18, io mem 0xc7813000 [ 5.459309] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 5.463191] ehci_hcd 0000:00:1a.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 5.468811] ehci_hcd 0000:00:1a.0: USB 2.0 started, EHCI 1.00 [ 5.469198] usb usb1: default language 0x0409 [ 5.469207] usb usb1: udev 1, busnum 1, minor = 0 [ 5.469210] usb usb1: New USB device found, idVendor=1d6b, idProduct=0002 [ 5.469578] usb usb1: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 5.470213] usb usb1: Product: EHCI Host Controller [ 5.470562] usb usb1: Manufacturer: Linux 3.0.8 ehci_hcd [ 5.470916] usb usb1: SerialNumber: 0000:00:1a.0 [ 5.471335] usb usb1: usb_probe_device [ 5.471337] usb usb1: configuration #1 chosen from 1 choice [ 5.471341] usb usb1: adding 1-0:1.0 (config #1, interface 0) [ 5.471394] hub 1-0:1.0: usb_probe_interface [ 5.471395] hub 1-0:1.0: usb_probe_interface - got id [ 5.471397] hub 1-0:1.0: USB hub found [ 5.471745] hub 1-0:1.0: 2 ports detected [ 5.472099] hub 1-0:1.0: standalone hub [ 5.472100] hub 1-0:1.0: no power switching (usb 1.0) [ 5.472101] hub 1-0:1.0: individual port over-current protection [ 5.472103] hub 1-0:1.0: power on to power good time: 20ms [ 5.472105] hub 1-0:1.0: local power source is good [ 5.472107] hub 1-0:1.0: trying to enable port power on non-switchable hub [ 5.472119] drivers/usb/core/inode.c: creating file '001' [ 5.472195] ehci_hcd 0000:00:1d.0: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 5.472559] ehci_hcd 0000:00:1d.0: setting latency timer to 64 [ 5.472561] ehci_hcd 0000:00:1d.0: EHCI Host Controller [ 5.472919] drivers/usb/core/inode.c: creating file '002' [ 5.472980] ehci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 5.473614] ehci_hcd 0000:00:1d.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 5.473617] ehci_hcd 0000:00:1d.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 5.473629] ehci_hcd 0000:00:1d.0: support lpm [ 5.473637] ehci_hcd 0000:00:1d.0: debug port 2 [ 5.473995] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 5.477887] ehci_hcd 0000:00:1d.0: cache line size of 64 is not supported [ 5.477890] ehci_hcd 0000:00:1d.0: supports USB remote wakeup [ 5.477894] ehci_hcd 0000:00:1d.0: irq 18, io mem 0xc7812000 [ 5.478246] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 5.482123] ehci_hcd 0000:00:1d.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 5.487789] ehci_hcd 0000:00:1d.0: USB 2.0 started, EHCI 1.00 [ 5.488166] usb usb2: default language 0x0409 [ 5.488169] usb usb2: udev 1, busnum 2, minor = 128 [ 5.488170] usb usb2: New USB device found, idVendor=1d6b, idProduct=0002 [ 5.488524] usb usb2: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 5.489160] usb usb2: Product: EHCI Host Controller [ 5.489509] usb usb2: Manufacturer: Linux 3.0.8 ehci_hcd [ 5.489863] usb usb2: SerialNumber: 0000:00:1d.0 [ 5.490273] usb usb2: usb_probe_device [ 5.490274] usb usb2: configuration #1 chosen from 1 choice [ 5.490277] usb usb2: adding 2-0:1.0 (config #1, interface 0) [ 5.490331] hub 2-0:1.0: usb_probe_interface [ 5.490332] hub 2-0:1.0: usb_probe_interface - got id [ 5.490333] hub 2-0:1.0: USB hub found [ 5.490681] hub 2-0:1.0: 2 ports detected [ 5.491035] hub 2-0:1.0: standalone hub [ 5.491036] hub 2-0:1.0: no power switching (usb 1.0) [ 5.491037] hub 2-0:1.0: individual port over-current protection [ 5.491038] hub 2-0:1.0: power on to power good time: 20ms [ 5.491040] hub 2-0:1.0: local power source is good [ 5.491041] hub 2-0:1.0: trying to enable port power on non-switchable hub [ 5.491052] drivers/usb/core/inode.c: creating file '001' [ 5.491152] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 5.491504] ohci_hcd: block sizes: ed 80 td 96 [ 5.491564] uhci_hcd: USB Universal Host Controller Interface driver [ 5.492058] usbcore: registered new interface driver usblp [ 5.492409] Initializing USB Mass Storage driver... [ 5.492823] usbcore: registered new interface driver usb-storage [ 5.493174] USB Mass Storage support registered. [ 5.493570] usbcore: registered new interface driver libusual [ 5.494097] i8042: PNP: No PS/2 controller found. Probing ports directly. [ 5.495318] i8042: No controller found [ 5.495718] mousedev: PS/2 mouse device common for all mice [ 5.496280] rtc_cmos 00:05: RTC can wake from S4 [ 5.496734] rtc_cmos 00:05: rtc core: registered rtc_cmos as rtc0 [ 5.497113] rtc0: alarms up to one month, y3k, 114 bytes nvram [ 5.497783] device-mapper: ioctl: 4.20.0-ioctl (2011-02-02) initialised: dm-devel@redhat.com [ 5.498483] cpuidle: using governor ladder [ 5.498839] cpuidle: using governor menu [ 5.499186] EFI Variables Facility v0.08 2004-May-17 [ 5.500780] usbcore: registered new interface driver usbhid [ 5.501130] usbhid: USB HID core driver [ 5.501816] ALSA device list: [ 5.502160] No soundcards found. [ 5.502540] Netfilter messages via NETLINK v0.30. [ 5.502918] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 5.503398] ctnetlink v0.93: registering with nfnetlink. [ 5.503969] TCP cubic registered [ 5.504313] Initializing XFRM netlink socket [ 5.504918] NET: Registered protocol family 10 [ 5.505794] IPv6 over IPv4 tunneling driver [ 5.506498] NET: Registered protocol family 17 [ 5.506865] Registering the dns_resolver key type [ 5.507369] PM: Hibernation image not present or could not be loaded. [ 5.509067] Magic number: 5:853:359 [ 5.595515] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 5.595518] hub 1-0:1.0: port 1: status 0501 change 0001 [ 5.595526] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 5.595528] hub 2-0:1.0: port 1: status 0501 change 0001 [ 5.597587] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 5.680654] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 5.694596] hub 1-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 5.694607] hub 1-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 5.745816] ehci_hcd 0000:00:1a.0: port 1 high speed [ 5.745819] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 5.796493] usb 1-1: new high speed USB device number 2 using ehci_hcd [ 5.847717] ehci_hcd 0000:00:1a.0: port 1 high speed [ 5.847721] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 5.910541] ehci_hcd 0000:00:1a.0: set dev address 2 for port 1 [ 5.910546] ehci_hcd 0000:00:1a.0: LPM: no device attached [ 5.910802] usb 1-1: udev 2, busnum 1, minor = 1 [ 5.910804] usb 1-1: New USB device found, idVendor=8087, idProduct=800a [ 5.911152] usb 1-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 5.911587] usb 1-1: usb_probe_device [ 5.911590] usb 1-1: configuration #1 chosen from 1 choice [ 5.911677] usb 1-1: adding 1-1:1.0 (config #1, interface 0) [ 5.911727] hub 1-1:1.0: usb_probe_interface [ 5.911729] hub 1-1:1.0: usb_probe_interface - got id [ 5.911731] hub 1-1:1.0: USB hub found [ 5.912160] hub 1-1:1.0: 6 ports detected [ 5.912511] hub 1-1:1.0: standalone hub [ 5.912513] hub 1-1:1.0: individual port power switching [ 5.912514] hub 1-1:1.0: individual port over-current protection [ 5.912515] hub 1-1:1.0: Single TT [ 5.912517] hub 1-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 5.912518] hub 1-1:1.0: power on to power good time: 0ms [ 5.912784] hub 1-1:1.0: local power source is good [ 5.912786] hub 1-1:1.0: enabling power on all ports [ 5.913551] drivers/usb/core/inode.c: creating file '002' [ 5.913590] hub 2-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 5.913598] hub 2-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 5.964603] ehci_hcd 0000:00:1d.0: port 1 high speed [ 5.964609] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 6.014069] usb 1-1: link qh256-0001/ffff88087be5d380 start 1 [1/0 us] [ 6.015287] usb 2-1: new high speed USB device number 2 using ehci_hcd [ 6.066503] ehci_hcd 0000:00:1d.0: port 1 high speed [ 6.066508] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 6.129327] ehci_hcd 0000:00:1d.0: set dev address 2 for port 1 [ 6.129332] ehci_hcd 0000:00:1d.0: LPM: no device attached [ 6.129577] usb 2-1: udev 2, busnum 2, minor = 129 [ 6.129580] usb 2-1: New USB device found, idVendor=8087, idProduct=8002 [ 6.129936] usb 2-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 6.130382] usb 2-1: usb_probe_device [ 6.130384] usb 2-1: configuration #1 chosen from 1 choice [ 6.130450] usb 2-1: adding 2-1:1.0 (config #1, interface 0) [ 6.130499] hub 2-1:1.0: usb_probe_interface [ 6.130500] hub 2-1:1.0: usb_probe_interface - got id [ 6.130501] hub 2-1:1.0: USB hub found [ 6.130946] hub 2-1:1.0: 8 ports detected [ 6.131297] hub 2-1:1.0: standalone hub [ 6.131298] hub 2-1:1.0: individual port power switching [ 6.131299] hub 2-1:1.0: individual port over-current protection [ 6.131301] hub 2-1:1.0: Single TT [ 6.131302] hub 2-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 6.131303] hub 2-1:1.0: power on to power good time: 0ms [ 6.131570] hub 2-1:1.0: local power source is good [ 6.131571] hub 2-1:1.0: enabling power on all ports [ 6.132583] drivers/usb/core/inode.c: creating file '002' [ 6.132593] hub 1-1:1.0: state 7 ports 6 chg 0000 evt 0000 [ 6.162144] Refined TSC clocksource calibration: 2999.998 MHz. [ 6.162509] Switching to clocksource tsc [ 6.232349] hub 2-1:1.0: port 3: status 0101 change 0001 [ 6.232970] hub 2-1:1.0: port 7: status 0101 change 0001 [ 6.332962] usb 2-1: link qh256-0001/ffff88087be5d900 start 1 [1/0 us] [ 6.332978] hub 2-1:1.0: state 7 ports 8 chg 0088 evt 0000 [ 6.333131] hub 2-1:1.0: port 3, status 0101, change 0000, 12 Mb/s [ 6.344113] hub 2-1:1.0: port 3 not reset yet, waiting 10ms [ 6.405935] usb 2-1.3: new low speed USB device number 3 using ehci_hcd [ 6.418041] hub 2-1:1.0: port 3 not reset yet, waiting 10ms [ 6.495473] usb 2-1.3: skipped 1 descriptor after interface [ 6.495477] usb 2-1.3: skipped 1 descriptor after interface [ 6.495969] usb 2-1.3: default language 0x0409 [ 6.499842] usb 2-1.3: udev 3, busnum 2, minor = 130 [ 6.499845] usb 2-1.3: New USB device found, idVendor=0557, idProduct=2221 [ 6.500208] usb 2-1.3: New USB device strings: Mfr=1, Product=2, SerialNumber=3 [ 6.500828] usb 2-1.3: Product: UC-10KM V1.3.124 [ 6.501170] usb 2-1.3: Manufacturer: ATEN [ 6.501511] usb 2-1.3: SerialNumber: USB Composite device [ 6.501925] usb 2-1.3: usb_probe_device [ 6.501926] usb 2-1.3: configuration #1 chosen from 1 choice [ 6.503587] usb 2-1.3: adding 2-1.3:1.0 (config #1, interface 0) [ 6.504912] usbhid 2-1.3:1.0: usb_probe_interface [ 6.504915] usbhid 2-1.3:1.0: usb_probe_interface - got id [ 6.509661] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.3/2-1.3:1.0/input/input2 [ 6.510308] usb 2-1.3: link qh8-0601/ffff88087bedc180 start 2 [1/2 us] [ 6.510405] generic-usb 0003:0557:2221.0001: input,hidraw0: USB HID v1.10 Keyboard [ATEN UC-10KM V1.3.124] on usb-0000:00:1d.0-1.3/input0 [ 6.511043] usb 2-1.3: adding 2-1.3:1.1 (config #1, interface 1) [ 6.512147] usbhid 2-1.3:1.1: usb_probe_interface [ 6.512150] usbhid 2-1.3:1.1: usb_probe_interface - got id [ 6.516225] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.3/2-1.3:1.1/input/input3 [ 6.516987] generic-usb 0003:0557:2221.0002: input,hidraw1: USB HID v1.10 Mouse [ATEN UC-10KM V1.3.124] on usb-0000:00:1d.0-1.3/input1 [ 6.517621] drivers/usb/core/inode.c: creating file '003' [ 6.517695] hub 2-1:1.0: port 7, status 0101, change 0000, 12 Mb/s [ 6.528949] hub 2-1:1.0: port 7 not reset yet, waiting 10ms [ 6.590756] usb 2-1.7: new high speed USB device number 4 using ehci_hcd [ 6.601861] hub 2-1:1.0: port 7 not reset yet, waiting 10ms [ 6.676043] usb 2-1.7: udev 4, busnum 2, minor = 131 [ 6.676047] usb 2-1.7: New USB device found, idVendor=0557, idProduct=7000 [ 6.684250] usb 2-1.7: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 6.684943] usb 2-1.7: usb_probe_device [ 6.684945] usb 2-1.7: configuration #1 chosen from 1 choice [ 6.685033] usb 2-1.7: adding 2-1.7:1.0 (config #1, interface 0) [ 6.685074] hub 2-1.7:1.0: usb_probe_interface [ 6.685075] hub 2-1.7:1.0: usb_probe_interface - got id [ 6.685076] hub 2-1.7:1.0: USB hub found [ 6.685530] hub 2-1.7:1.0: 4 ports detected [ 6.685873] hub 2-1.7:1.0: standalone hub [ 6.685874] hub 2-1.7:1.0: ganged power switching [ 6.685875] hub 2-1.7:1.0: global over-current protection [ 6.685876] hub 2-1.7:1.0: Single TT [ 6.685878] hub 2-1.7:1.0: TT requires at most 8 FS bit times (666 ns) [ 6.685879] hub 2-1.7:1.0: power on to power good time: 0ms [ 6.686154] hub 2-1.7:1.0: local power source is lost (inactive) [ 6.686155] hub 2-1.7:1.0: no over-current condition exists [ 6.686156] hub 2-1.7:1.0: enabling power on all ports [ 6.686671] drivers/usb/core/inode.c: creating file '004' [ 6.786690] hub 2-1.7:1.0: port 1: status 0101 change 0001 [ 6.886421] usb 2-1.7: link qh256-0001/ffff88087bedc300 start 3 [1/0 us] [ 6.886433] hub 2-1.7:1.0: state 7 ports 4 chg 0002 evt 0000 [ 6.886595] hub 2-1.7:1.0: port 1, status 0101, change 0000, 12 Mb/s [ 6.968511] usb 2-1.7.1: new low speed USB device number 5 using ehci_hcd [ 7.070033] usb 2-1.7.1: skipped 1 descriptor after interface [ 7.070037] usb 2-1.7.1: skipped 1 descriptor after interface [ 7.070041] usb 2-1.7.1: udev 5, busnum 2, minor = 132 [ 7.070044] usb 2-1.7.1: New USB device found, idVendor=0557, idProduct=2419 [ 7.070410] usb 2-1.7.1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 7.071082] usb 2-1.7.1: usb_probe_device [ 7.071084] usb 2-1.7.1: configuration #1 chosen from 1 choice [ 7.071159] usb 2-1.7.1: adding 2-1.7.1:1.0 (config #1, interface 0) [ 7.071208] usbhid 2-1.7.1:1.0: usb_probe_interface [ 7.071209] usbhid 2-1.7.1:1.0: usb_probe_interface - got id [ 7.071891] input: HID 0557:2419 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.7/2-1.7.1/2-1.7.1:1.0/input/input4 [ 7.072546] usb 2-1.7.1: link qh8-0601/ffff88087bedc480 start 4 [1/2 us] [ 7.072648] generic-usb 0003:0557:2419.0003: input,hidraw2: USB HID v1.00 Keyboard [HID 0557:2419] on usb-0000:00:1d.0-1.7.1/input0 [ 7.073288] usb 2-1.7.1: adding 2-1.7.1:1.1 (config #1, interface 1) [ 7.073337] usbhid 2-1.7.1:1.1: usb_probe_interface [ 7.073339] usbhid 2-1.7.1:1.1: usb_probe_interface - got id [ 7.074256] input: HID 0557:2419 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.7/2-1.7.1/2-1.7.1:1.1/input/input5 [ 7.075032] generic-usb 0003:0557:2419.0004: input,hidraw3: USB HID v1.00 Mouse [HID 0557:2419] on usb-0000:00:1d.0-1.7.1/input1 [ 7.075668] drivers/usb/core/inode.c: creating file '005' [ 9.162562] igb: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 9.166035] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 9.174179] Sending DHCP requests . [ 9.335381] igb: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 9.338798] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 12.223193] ., OK [ 12.234185] IP-Config: Got DHCP answer from 10.68.10.100, my address is 10.68.10.220 [ 12.283204] IP-Config: Complete: [ 12.283545] device=eth0, addr=10.68.10.220, mask=255.255.255.0, gw=10.68.10.1, [ 12.284079] host=k1ey0, domain=kagra.icrr.u-tokyo.ac.jp, nis-domain=(none), [ 12.284762] bootserver=10.68.10.100, rootserver=10.68.10.100, rootpath= [ 12.285668] md: Waiting for all devices to be available before autodetect [ 12.286014] md: If you don't use raid, use raid=noautodetect [ 12.286598] md: Autodetecting RAID arrays. [ 12.286939] md: Scanned 0 and added 0 devices. [ 12.287283] md: autorun ... [ 12.287621] md: ... autorun DONE. [ 12.290843] VFS: Mounted root (nfs filesystem) readonly on device 0:14. [ 12.292097] Freeing unused kernel memory: 628k freed [ 12.292663] Write protecting the kernel read-only data: 10240k [ 12.294595] Freeing unused kernel memory: 724k freed [ 12.297976] Freeing unused kernel memory: 1368k freed [ 12.390132] hostname used greatest stack depth: 4120 bytes left [ 12.445770] mount.nfs used greatest stack depth: 3848 bytes left [ 12.826182] depscan.sh used greatest stack depth: 3776 bytes left [ 13.512295] igb 0000:01:00.1: changing MTU from 1500 to 9000 [ 13.630539] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 13.664938] Open-MX 1.5.3 initializing... [ 13.665289] Open-MX: attaching interfaces listed in 'eth1'... [ 13.665629] Open-MX: Attaching Ethernet interface 'eth1' as #0, MTU=9000 [ 13.665972] Open-MX: Interface 'eth1' is PCI device '0000:01:00.1' managed by driver 'igb' [ 13.666584] Open-MX: attached 1 interfaces [ 13.667013] Open-MX initialized [ 17.029884] igb: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 17.032332] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 20.158441] eth0: no IPv6 routers present [ 27.095647] eth1: no IPv6 routers present [ 34.993293] Spectracom GPS card on bus 82; device 0 [ 34.993700] pci 0000:82:00.0: PCI INT A -> GSI 58 (level, low) -> IRQ 58 [ 34.994068] TSYNC PIC BASE 0 address = f8100000 [ 34.994453] Remapped 0xffffc900288fe000 [ 40.014382] TSYNC receiving YEAR info [ 40.014716] date = 167 days 2:17:1316485030 [ 40.015051] bcd time = 1316485030 sec 808 milliseconds 101 microseconds 808098830 nanosec [ 40.015657] Board sync = 1 [ 40.025983] TSYNC receiving YEAR info [ 40.026318] date = 267 days 2:17:1316485030 [ 40.026651] bcd time = 1316485030 sec 819 milliseconds 713 microseconds 819710670 nanosec [ 40.027257] Board sync = 1 [ 50.400299] k1iopey0: startup time is 1316485041 [ 50.400301] k1iopey0: cpu clock 3000056 [ 50.400303] k1iopey0: EPICSM at 0x28900000 [ 50.400593] k1iopey0: IPC at 0x2c98f000 [ 50.400594] k1iopey0: IOMEM at 0x2c993000 size 0x33410 [ 50.400595] k1iopey0: DAQSM at 0x1482a000 [ 50.400596] k1iopey0: configured to use 7 cards [ 50.400597] k1iopey0: Initializing PCI Modules [ 50.400632] k1iopey0: ADC card on bus 19; device 4 prim 19 [ 50.400633] k1iopey0: adc card on bus 19; device 4 prim 19 [ 50.400691] pci 0000:19:04.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 50.404465] k1iopey0: pci0 = 0xc7501000 [ 50.404503] k1iopey0: pci2 = 0xc7500000 [ 50.404508] k1iopey0: ADC I/O address=0xc7500000 0xffffc90013fdc000 [ 50.404512] k1iopey0: BCR = 0x84060 [ 50.404525] k1iopey0: RAG = 0x117d8 [ 50.404528] k1iopey0: BCR = 0x84260 [ 50.832513] k1iopey0: SSC = 0x16 [ 50.832516] k1iopey0: IDBC = 0x1f [ 50.832524] k1iopey0: ADC card on bus 1b; device 0 prim 1b [ 50.832525] k1iopey0: adc card on bus 1b; device 0 prim 1b [ 50.832537] pci 0000:1b:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 50.836204] k1iopey0: pci0 = 0xc7401000 [ 50.836211] k1iopey0: pci2 = 0xc7400000 [ 50.836215] k1iopey0: ADC I/O address=0xc7400000 0xffffc90013fe0000 [ 50.836218] k1iopey0: BCR = 0x84060 [ 50.836231] k1iopey0: RAG = 0x117d8 [ 50.836234] k1iopey0: BCR = 0x84260 [ 51.264217] k1iopey0: SSC = 0x16 [ 51.264221] k1iopey0: IDBC = 0x1f [ 51.264270] k1iopey0: DAC card on bus 1f; device 4 prim 1f [ 51.264272] k1iopey0: dac card on bus 1f; device 4 [ 51.264292] pci 0000:1f:04.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 51.265970] k1iopey0: pci0 = 0xc7301000 [ 51.265985] k1iopey0: dac pci2 = 0xc7300000 [ 51.265990] k1iopey0: DAC I/O address=0xc7300000 0xffffc90013fe4000 [ 51.265993] k1iopey0: DAC BCR = 0x810 [ 51.266118] k1iopey0: DAC BCR after init = 0x30080 [ 51.266121] k1iopey0: DAC CSR = 0xffff [ 51.266127] k1iopey0: DAC BOR = 0x3415 [ 51.266134] k1iopey0: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [ 51.266157] k1iopey0: DAC card on bus 21; device 4 prim 21 [ 51.266158] k1iopey0: dac card on bus 21; device 4 [ 51.266169] pci 0000:21:04.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 51.269850] k1iopey0: pci0 = 0xc7201000 [ 51.269857] k1iopey0: dac pci2 = 0xc7200000 [ 51.269862] k1iopey0: DAC I/O address=0xc7200000 0xffffc90013fe8000 [ 51.269865] k1iopey0: DAC BCR = 0x810 [ 51.269988] k1iopey0: DAC BCR after init = 0x30080 [ 51.269991] k1iopey0: DAC CSR = 0xffff [ 51.269998] k1iopey0: DAC BOR = 0x3415 [ 51.270003] k1iopey0: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [ 51.270024] k1iopey0: ADC card on bus 23; device 4 prim 23 [ 51.270025] k1iopey0: adc card on bus 23; device 4 prim 23 [ 51.270036] pci 0000:23:04.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 51.273716] k1iopey0: pci0 = 0xc7101000 [ 51.273723] k1iopey0: pci2 = 0xc7100000 [ 51.273727] k1iopey0: ADC I/O address=0xc7100000 0xffffc90013fec000 [ 51.273730] k1iopey0: BCR = 0x84060 [ 51.273743] k1iopey0: RAG = 0x117d8 [ 51.273746] k1iopey0: BCR = 0x84260 [ 51.701731] k1iopey0: SSC = 0x16 [ 51.701734] k1iopey0: IDBC = 0x1f [ 51.701779] k1iopey0: Contec 1616 DIO card on bus 15; device 0 [ 51.701789] pci 0000:15:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 51.703128] k1iopey0: contec 1616 dio pci2 = 0x6001 [ 51.703129] k1iopey0: contec 1616 diospace = 0x6000 [ 51.703132] k1iopey0: contec dio pci2 card number= 0x0 [ 51.703140] k1iopey0: Contec BO card on bus 17; device 0 [ 51.703149] pci 0000:17:00.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 51.712448] k1iopey0: contec dio pci2 = 0x5001 [ 51.712449] k1iopey0: contec32L diospace = 0x5000 [ 51.712452] k1iopey0: contec dio pci2 card number= 0xa [ 51.712461] k1iopey0: 5565 RFM card on bus 85; device c [ 51.712474] pci 0000:85:0c.0: PCI INT A -> GSI 66 (level, low) -> IRQ 66 [ 51.721326] k1iopey0: RFM address is 0x4026531840x [ 51.721327] k1iopey0: CSR address is 0xf8000000 [ 51.721336] k1iopey0: Board id = 0x65 [ 51.721338] k1iopey0: VMIC5565 set to single transfers [ 51.721340] k1iopey0: VMIC5565 ROGUE MASTER 1 = OFF [ 51.721341] k1iopey0: VMIC5565 ROGUE MASTER 0 = OFF [ 51.721343] k1iopey0: VMIC5565 Memory size = 128MBytes [ 51.721344] k1iopey0: DMA address is 0x4160753664x [ 51.721356] k1iopey0: 5565DMA at 0xffffc90013ff0000 [ 51.721358] k1iopey0: 5565 INTCR = 0x251724032x [ 51.721359] k1iopey0: 5565 INTCR = 0x251723776x [ 51.721361] k1iopey0: 5565 MODE = 0x132483x [ 51.721362] k1iopey0: 5565 DESC = 0x1x [ 51.721371] k1iopey0: TSYNC GPS card on bus 82; device 0 [ 51.721375] k1iopey0: TSYNC PIC BASE 0 address = f8100000 [ 51.721379] k1iopey0: Remapped 0xffffc90013ff2000 [ 56.737872] k1iopey0: TSYNC receiving YEAR info [ 56.737875] k1iopey0: date = 267 days 2:17:1316485047 [ 56.737876] k1iopey0: bcd time = 1316485047 sec 547 milliseconds 986 microseconds 547981470 nanosec [ 56.737877] k1iopey0: Board sync = 1 [ 56.747873] k1iopey0: TSYNC receiving YEAR info [ 56.747876] k1iopey0: date = 267 days 2:17:1316485047 [ 56.747877] k1iopey0: bcd time = 1316485047 sec 557 milliseconds 997 microseconds 557992970 nanosec [ 56.747878] k1iopey0: Board sync = 1 [ 56.747879] k1iopey0: 9 PCI cards found [ 56.747880] k1iopey0: *************************************************************************** [ 56.747881] k1iopey0: 3 ADC cards found [ 56.747882] k1iopey0: ADC 0 is a GSC_16AI64SSA module [ 56.747883] k1iopey0: Channels = 64 [ 56.747884] k1iopey0: Firmware Rev = 1 [ 56.747884] [ 56.747885] k1iopey0: ADC 1 is a GSC_16AI64SSA module [ 56.747886] k1iopey0: Channels = 64 [ 56.747886] k1iopey0: Firmware Rev = 545 [ 56.747887] [ 56.747887] k1iopey0: ADC 2 is a GSC_16AI64SSA module [ 56.747888] k1iopey0: Channels = 64 [ 56.747889] k1iopey0: Firmware Rev = 16 [ 56.747890] [ 56.747890] k1iopey0: *************************************************************************** [ 56.747892] k1iopey0: 2 DAC cards found [ 56.747892] k1iopey0: DAC 0 is a GSC_16AO16 module [ 56.747893] k1iopey0: Channels = 16 [ 56.747894] k1iopey0: Filters = None [ 56.747895] k1iopey0: Output Type = Differential [ 56.747895] k1iopey0: Firmware Rev = 18 [ 56.747896] [ 56.747897] k1iopey0: MASTER DAC SLOT 0 3 [ 56.747897] k1iopey0: DAC 1 is a GSC_16AO16 module [ 56.747898] k1iopey0: Channels = 16 [ 56.747899] k1iopey0: Filters = None [ 56.747899] k1iopey0: Output Type = Differential [ 56.747900] k1iopey0: Firmware Rev = 18 [ 56.747900] [ 56.747901] k1iopey0: MASTER DAC SLOT 1 4 [ 56.747902] k1iopey0: *************************************************************************** [ 56.747903] k1iopey0: 0 DIO cards found [ 56.747904] k1iopey0: *************************************************************************** [ 56.747905] k1iopey0: 0 IIRO-8 Isolated DIO cards found [ 56.747906] k1iopey0: *************************************************************************** [ 56.747907] k1iopey0: 0 IIRO-16 Isolated DIO cards found [ 56.747908] k1iopey0: *************************************************************************** [ 56.747909] k1iopey0: 1 Contec 32ch PCIe DO cards found [ 56.747910] k1iopey0: 1 Contec PCIe DIO1616 cards found [ 56.747911] k1iopey0: 0 Contec PCIe DIO6464 cards found [ 56.747912] k1iopey0: 2 DO cards found [ 56.747912] k1iopey0: TDS controller 0 is at 0 [ 56.747913] k1iopey0: Total of 7 I/O modules found and mapped [ 56.747914] k1iopey0: *************************************************************************** [ 56.747915] k1iopey0: 1 RFM cards found [ 56.747917] k1iopey0: RFM 0 is a VMIC_5565 module with Node ID 48 [ 56.747918] k1iopey0: address is 0xffffc9002ce00000 [ 56.747918] k1iopey0: *************************************************************************** [ 56.747920] k1iopey0: IRIG-B card found 2 [ 56.747920] k1iopey0: *************************************************************************** [ 56.747921] k1iopey0: Initializing space for daqLib buffers [ 56.849808] CPU 1 is now offline [ 56.849919] k1iopey0: Sync source = 4 [ 56.849920] k1iopey0: Waiting for EPICS BURT Restore = 1 [ 56.909851] k1iopey0: Waiting for EPICS BURT 0 [ 56.909852] k1iopey0: BURT Restore Complete [ 56.909860] k1iopey0: Initialized servo control parameters. [ 56.910860] k1iopey0: DAQ Ex Min/Max = 1 3 [ 56.910860] k1iopey0: DAQ XEx Min/Max = 3 53 [ 56.910861] k1iopey0: DAQ Tp Min/Max = 10001 10007 [ 56.910862] k1iopey0: DAQ XTp Min/Max = 10007 10507 [ 56.910881] k1iopey0: Have 346 CDS epics integer and 0 USR epics integer channels [ 56.910882] k1iopey0: DAQ EPICS INT DATA is at 0xffffc90028901028 with size 1384 [ 56.910883] k1iopey0: DAQ EPICS FLT DATA is at 0xffffc90028901590 [ 56.910885] k1iopey0: DAQ EPICS: Int = 346 Flt = 97 Filters = 22 Total = 465 Fast = 0 [ 56.910886] k1iopey0: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [ 56.910887] k1iopey0: crc length epics = 1860 [ 56.910889] k1iopey0: xfer sizes = 4096 0 1860 1860 [ 56.910890] k1iopey0: Calling feCode() to initialize [ 56.910895] k1iopey0: ADC setup complete [ 56.910897] k1iopey0: DAC setup complete [ 56.910900] k1iopey0: writing BIO 0 [ 56.990830] k1iopey0: writing DAC 0 [ 56.990841] k1iopey0: writing DAC 1 [ 56.990869] k1iopey0: Triggered the ADC [ 67.794251] k1tmsy: startup time is 1316485058 [ 67.794252] k1tmsy: cpu clock 3000056 [ 67.794254] k1tmsy: EPICSM at 0x34e01000 [ 67.794255] k1tmsy: IPC at 0x2c98f000 [ 67.794256] k1tmsy: IOMEM at 0x2c993000 size 0x33410 [ 67.794257] k1tmsy: DAQSM at 0x1884c000 [ 67.794258] k1tmsy: configured to use 3 cards [ 67.794259] k1tmsy: Initializing PCI Modules [ 67.794260] k1tmsy: 9 PCI cards found [ 67.794261] k1tmsy: Found ADC at 0 0 [ 67.794262] k1tmsy: Found ADC at 1 1 [ 67.794263] k1tmsy: Found ADC at 2 2 [ 67.794264] k1tmsy: 3 PCI cards found [ 67.794264] k1tmsy: *************************************************************************** [ 67.794265] k1tmsy: 3 ADC cards found [ 67.794266] k1tmsy: ADC 0 is a GSC_16AI64SSA module [ 67.794267] k1tmsy: Channels = 64 [ 67.794268] k1tmsy: Firmware Rev = 0 [ 67.794268] [ 67.794269] k1tmsy: ADC 1 is a GSC_16AI64SSA module [ 67.794269] k1tmsy: Channels = 64 [ 67.794270] k1tmsy: Firmware Rev = 1 [ 67.794271] [ 67.794271] k1tmsy: ADC 2 is a GSC_16AI64SSA module [ 67.794272] k1tmsy: Channels = 64 [ 67.794273] k1tmsy: Firmware Rev = 2 [ 67.794273] [ 67.794274] k1tmsy: *************************************************************************** [ 67.794275] k1tmsy: 0 DAC cards found [ 67.794275] k1tmsy: *************************************************************************** [ 67.794277] k1tmsy: 0 DIO cards found [ 67.794277] k1tmsy: *************************************************************************** [ 67.794278] k1tmsy: 0 IIRO-8 Isolated DIO cards found [ 67.794279] k1tmsy: *************************************************************************** [ 67.794280] k1tmsy: 0 IIRO-16 Isolated DIO cards found [ 67.794281] k1tmsy: *************************************************************************** [ 67.794282] k1tmsy: 0 Contec 32ch PCIe DO cards found [ 67.794283] k1tmsy: 0 Contec PCIe DIO1616 cards found [ 67.794284] k1tmsy: 0 Contec PCIe DIO6464 cards found [ 67.794285] k1tmsy: 0 DO cards found [ 67.794286] k1tmsy: *************************************************************************** [ 67.794287] k1tmsy: 1 RFM cards found [ 67.794288] k1tmsy: RFM 0 is a VMIC_0 module with Node ID 0 [ 67.794289] k1tmsy: address is 0xffffc9002ce00000 [ 67.794290] k1tmsy: *************************************************************************** [ 67.794291] k1tmsy: Initializing space for daqLib buffers [ 67.794292] k1tmsy: Epics burt restore is 0 [ 68.793858] k1tmsy: Epics burt restore is 0 [ 69.896002] CPU 2 is now offline [ 69.896105] k1tmsy: Sync source = 8 [ 69.896107] k1tmsy: Waiting for EPICS BURT Restore = 1 [ 69.956038] k1tmsy: Waiting for EPICS BURT 0 [ 69.956039] k1tmsy: BURT Restore Complete [ 69.956194] k1tmsy: Initialized servo control parameters. [ 69.957194] k1tmsy: DAQ Ex Min/Max = 1 49 [ 69.957195] k1tmsy: DAQ XEx Min/Max = 49 99 [ 69.957196] k1tmsy: DAQ Tp Min/Max = 10001 10145 [ 69.957197] k1tmsy: DAQ XTp Min/Max = 10145 10645 [ 69.957217] k1tmsy: Have 245 CDS epics integer and 28 USR epics integer channels [ 69.957218] k1tmsy: Have int mem hole after CDS 980 112 [ 69.957219] k1tmsy: Have mem holes after CDS 980 112 [ 69.957220] Need to cpy ints twice - size 1 = 980 size 2 = 112 [ 69.957221] k1tmsy: DAQ EPICS INT DATA is at 0xffffc90034e02028 with size 1092 [ 69.957223] k1tmsy: DAQ EPICS FLT DATA is at 0xffffc90034e02470 [ 69.957224] k1tmsy: DAQ EPICS: Int = 273 Flt = 70 Filters = 528 Total = 871 Fast = 21 [ 69.957225] k1tmsy: DAQ EPICS: Number of Filter Module Xfers = 3 last = 48 [ 69.957226] k1tmsy: crc length epics = 3484 [ 69.957228] k1tmsy: xfer sizes = 1024 11 12188 12188 [ 69.957232] k1tmsy: Calling feCode() to initialize [ 69.957234] k1tmsy: size of data block = 0x80000 [ 69.957235] k1tmsy: Dolphin num = 0 at 0x0 and 0x0 [ 69.957237] k1tmsy: waiting to sync 51136 [ 70.176724] k1tmsy: Synched 219701 [ 81.153758] k1vistmsy: startup time is 1316485071 [ 81.153760] k1vistmsy: cpu clock 3000056 [ 81.153764] k1vistmsy: EPICSM at 0x38e91000 [ 81.153765] k1vistmsy: IPC at 0x2c98f000 [ 81.153766] k1vistmsy: IOMEM at 0x2c993000 size 0x33410 [ 81.153767] k1vistmsy: DAQSM at 0x1c86e000 [ 81.153768] k1vistmsy: configured to use 8 cards [ 81.153769] k1vistmsy: Initializing PCI Modules [ 81.153770] k1vistmsy: 9 PCI cards found [ 81.153770] k1vistmsy: Found ADC at 0 0 [ 81.153771] k1vistmsy: Found ADC at 1 1 [ 81.153772] k1vistmsy: Found ADC at 2 2 [ 81.153773] k1vistmsy: Found DAC at 3 4 [ 81.153774] k1vistmsy: 4 PCI cards found [ 81.153775] k1vistmsy: ERROR **** Did not find correct number of cards! Expected 8 and Found 4 [ 81.153777] k1vistmsy: *************************************************************************** [ 81.153778] k1vistmsy: 3 ADC cards found [ 81.153778] k1vistmsy: ADC 0 is a GSC_16AI64SSA module [ 81.153779] k1vistmsy: Channels = 64 [ 81.153780] k1vistmsy: Firmware Rev = 0 [ 81.153780] [ 81.153781] k1vistmsy: ADC 1 is a GSC_16AI64SSA module [ 81.153782] k1vistmsy: Channels = 64 [ 81.153783] k1vistmsy: Firmware Rev = 1 [ 81.153783] [ 81.153784] k1vistmsy: ADC 2 is a GSC_16AI64SSA module [ 81.153784] k1vistmsy: Channels = 64 [ 81.153785] k1vistmsy: Firmware Rev = 2 [ 81.153785] [ 81.153786] k1vistmsy: *************************************************************************** [ 81.153787] k1vistmsy: 1 DAC cards found [ 81.153788] k1vistmsy: DAC 0 is a GSC_16AO16 module [ 81.153789] k1vistmsy: Channels = 64 [ 81.153789] k1vistmsy: Filters = None [ 81.153790] k1vistmsy: Firmware Rev = 4 [ 81.153791] [ 81.153791] k1vistmsy: *************************************************************************** [ 81.153792] k1vistmsy: 0 DIO cards found [ 81.153793] k1vistmsy: *************************************************************************** [ 81.153794] k1vistmsy: 0 IIRO-8 Isolated DIO cards found [ 81.153795] k1vistmsy: *************************************************************************** [ 81.153796] k1vistmsy: 0 IIRO-16 Isolated DIO cards found [ 81.153797] k1vistmsy: *************************************************************************** [ 81.153798] k1vistmsy: 0 Contec 32ch PCIe DO cards found [ 81.153799] k1vistmsy: 0 Contec PCIe DIO1616 cards found [ 81.153800] k1vistmsy: 0 Contec PCIe DIO6464 cards found [ 81.153801] k1vistmsy: 0 DO cards found [ 81.153802] k1vistmsy: *************************************************************************** [ 81.153803] k1vistmsy: 1 RFM cards found [ 81.153804] k1vistmsy: RFM 0 is a VMIC_0 module with Node ID 0 [ 81.153805] k1vistmsy: address is 0xffffc9002ce00000 [ 81.153806] k1vistmsy: *************************************************************************** [ 81.153807] k1vistmsy: Initializing space for daqLib buffers [ 81.153808] k1vistmsy: Epics burt restore is 0 [ 82.153791] k1vistmsy: Epics burt restore is 0 [ 83.153811] k1vistmsy: Epics burt restore is 0 [ 84.255941] CPU 3 is now offline [ 84.256045] k1vistmsy: Sync source = 8 [ 84.256047] k1vistmsy: Waiting for EPICS BURT Restore = 1 [ 84.315978] k1vistmsy: Waiting for EPICS BURT 0 [ 84.315979] k1vistmsy: BURT Restore Complete [ 84.316183] k1vistmsy: Initialized servo control parameters. [ 84.317184] k1vistmsy: DAQ Ex Min/Max = 20001 20066 [ 84.317185] k1vistmsy: DAQ XEx Min/Max = 20066 20116 [ 84.317186] k1vistmsy: DAQ Tp Min/Max = 30001 30196 [ 84.317187] k1vistmsy: DAQ XTp Min/Max = 30196 30696 [ 84.317207] k1vistmsy: Have 294 CDS epics integer and 42 USR epics integer channels [ 84.317209] k1vistmsy: DAQ EPICS INT DATA is at 0xffffc90038e92028 with size 1344 [ 84.317210] k1vistmsy: DAQ EPICS FLT DATA is at 0xffffc90038e92568 [ 84.317212] k1vistmsy: DAQ EPICS: Int = 336 Flt = 283 Filters = 715 Total = 1334 Fast = 18 [ 84.317213] k1vistmsy: DAQ EPICS: Number of Filter Module Xfers = 3 last = 65 [ 84.317214] k1vistmsy: crc length epics = 5336 [ 84.317216] k1vistmsy: xfer sizes = 128 113 14552 14552 [ 84.317219] k1vistmsy: Calling feCode() to initialize [ 84.317220] k1vistmsy: size of data block = 0x80000 [ 84.317221] k1vistmsy: Dolphin num = 0 at 0x0 and 0x0 [ 84.317224] k1vistmsy: Setting card local=0 global = 1 channel=8 dac usage [ 84.317225] k1vistmsy: Setting card local=0 global = 1 channel=9 dac usage [ 84.317226] k1vistmsy: Setting card local=0 global = 1 channel=11 dac usage [ 84.317227] k1vistmsy: Setting card local=0 global = 1 channel=12 dac usage [ 84.317229] k1vistmsy: Setting card local=0 global = 1 channel=13 dac usage [ 84.317230] k1vistmsy: Setting card local=0 global = 1 channel=14 dac usage [ 84.317231] k1vistmsy: waiting to sync 10112 [ 85.162034] k1vistmsy: Synched 845627 [ 96.416368] k1caley: startup time is 1316485087 [ 96.416370] k1caley: cpu clock 3000056 [ 96.416372] k1caley: EPICSM at 0x3cf34000 [ 96.416373] k1caley: IPC at 0x2c98f000 [ 96.416374] k1caley: IOMEM at 0x2c993000 size 0x33410 [ 96.416375] k1caley: DAQSM at 0x20890000 [ 96.416376] k1caley: configured to use 3 cards [ 96.416377] k1caley: Initializing PCI Modules [ 96.416378] k1caley: 9 PCI cards found [ 96.416379] k1caley: Found ADC at 0 0 [ 96.416380] k1caley: Found DAC at 1 3 [ 96.416381] k1caley: Found 32 DO CONTEC at 2 0x5000 [ 96.416383] k1caley: 3 PCI cards found [ 96.416383] k1caley: *************************************************************************** [ 96.416384] k1caley: 1 ADC cards found [ 96.416385] k1caley: ADC 0 is a GSC_16AI64SSA module [ 96.416386] k1caley: Channels = 64 [ 96.416387] k1caley: Firmware Rev = 0 [ 96.416387] [ 96.416388] k1caley: *************************************************************************** [ 96.416389] k1caley: 1 DAC cards found [ 96.416390] k1caley: DAC 0 is a GSC_16AO16 module [ 96.416390] k1caley: Channels = 64 [ 96.416391] k1caley: Filters = None [ 96.416392] k1caley: Firmware Rev = 3 [ 96.416392] [ 96.416393] k1caley: *************************************************************************** [ 96.416394] k1caley: 0 DIO cards found [ 96.416395] k1caley: *************************************************************************** [ 96.416396] k1caley: 0 IIRO-8 Isolated DIO cards found [ 96.416397] k1caley: *************************************************************************** [ 96.416398] k1caley: 0 IIRO-16 Isolated DIO cards found [ 96.416399] k1caley: *************************************************************************** [ 96.416400] k1caley: 1 Contec 32ch PCIe DO cards found [ 96.416401] k1caley: 0 Contec PCIe DIO1616 cards found [ 96.416402] k1caley: 0 Contec PCIe DIO6464 cards found [ 96.416402] k1caley: 1 DO cards found [ 96.416403] k1caley: *************************************************************************** [ 96.416405] k1caley: 1 RFM cards found [ 96.416405] k1caley: RFM 0 is a VMIC_0 module with Node ID 0 [ 96.416406] k1caley: address is 0xffffc9002ce00000 [ 96.416407] k1caley: *************************************************************************** [ 96.416408] k1caley: Initializing space for daqLib buffers [ 96.416410] k1caley: Epics burt restore is 0 [ 97.415865] k1caley: Epics burt restore is 0 [ 98.415886] k1caley: Epics burt restore is 0 [ 99.518104] CPU 4 is now offline [ 99.518209] k1caley: Sync source = 8 [ 99.518211] k1caley: Waiting for EPICS BURT Restore = 1 [ 99.519697] CPU 5 MCA banks CMCI:5 CMCI:6 CMCI:7 CMCI:9 CMCI:10 CMCI:11 CMCI:12 CMCI:17 CMCI:18 CMCI:19 CMCI:20 [ 99.575673] k1caley: Waiting for EPICS BURT 0 [ 99.575673] k1caley: BURT Restore Complete [ 99.576081] k1caley: Initialized servo control parameters. [ 99.577082] k1caley: DAQ Ex Min/Max = 1 134 [ 99.577083] k1caley: DAQ XEx Min/Max = 134 184 [ 99.577084] k1caley: DAQ Tp Min/Max = 10001 10400 [ 99.577085] k1caley: DAQ XTp Min/Max = 10400 10900 [ 99.577105] k1caley: Have 164 CDS epics integer and 23 USR epics integer channels [ 99.577106] k1caley: Have int mem hole after user 656 92 [ 99.577108] k1caley: DAQ EPICS INT DATA is at 0xffffc9003cf35028 with size 748 [ 99.577109] k1caley: DAQ EPICS FLT DATA is at 0xffffc9003cf35318 [ 99.577111] k1caley: DAQ EPICS: Int = 187 Flt = 386 Filters = 1463 Total = 2036 Fast = 20 [ 99.577112] k1caley: DAQ EPICS: Number of Filter Module Xfers = 4 last = 33 [ 99.577113] k1caley: crc length epics = 8144 [ 99.577115] k1caley: xfer sizes = 1024 32 33360 33360 [ 99.577121] k1caley: Calling feCode() to initialize [ 99.577122] k1caley: size of data block = 0x80000 [ 99.577123] k1caley: Dolphin num = 0 at 0x0 and 0x0 [ 99.577132] k1caley: Setting card local=0 global = 0 channel=0 dac usage [ 99.577134] k1caley: Setting card local=0 global = 0 channel=4 dac usage [ 99.577135] k1caley: Setting card local=0 global = 0 channel=5 dac usage [ 99.577136] k1caley: Setting card local=0 global = 0 channel=6 dac usage [ 99.577137] k1caley: Setting card local=0 global = 0 channel=7 dac usage [ 99.577138] k1caley: Setting card local=0 global = 0 channel=8 dac usage [ 99.577139] k1caley: waiting to sync 28096 [ 100.147344] k1caley: Synched 570760 [ 110.771739] k1pemey0: startup time is 1316485101 [ 110.771741] k1pemey0: cpu clock 3000056 [ 110.771743] k1pemey0: EPICSM at 0x41025000 [ 110.771744] k1pemey0: IPC at 0x2c98f000 [ 110.771745] k1pemey0: IOMEM at 0x2c993000 size 0x33410 [ 110.771746] k1pemey0: DAQSM at 0x248b2000 [ 110.771747] k1pemey0: configured to use 2 cards [ 110.771747] k1pemey0: Initializing PCI Modules [ 110.771749] k1pemey0: 9 PCI cards found [ 110.771750] k1pemey0: Found ADC at 0 0 [ 110.771750] k1pemey0: Found ADC at 1 1 [ 110.771751] k1pemey0: 2 PCI cards found [ 110.771752] k1pemey0: *************************************************************************** [ 110.771754] k1pemey0: 2 ADC cards found [ 110.771754] k1pemey0: ADC 0 is a GSC_16AI64SSA module [ 110.771755] k1pemey0: Channels = 64 [ 110.771756] k1pemey0: Firmware Rev = 0 [ 110.771756] [ 110.771757] k1pemey0: ADC 1 is a GSC_16AI64SSA module [ 110.771758] k1pemey0: Channels = 64 [ 110.771759] k1pemey0: Firmware Rev = 1 [ 110.771759] [ 110.771760] k1pemey0: *************************************************************************** [ 110.771761] k1pemey0: 0 DAC cards found [ 110.771762] k1pemey0: *************************************************************************** [ 110.771763] k1pemey0: 0 DIO cards found [ 110.771763] k1pemey0: *************************************************************************** [ 110.771765] k1pemey0: 0 IIRO-8 Isolated DIO cards found [ 110.771766] k1pemey0: *************************************************************************** [ 110.771767] k1pemey0: 0 IIRO-16 Isolated DIO cards found [ 110.771768] k1pemey0: *************************************************************************** [ 110.771769] k1pemey0: 0 Contec 32ch PCIe DO cards found [ 110.771770] k1pemey0: 0 Contec PCIe DIO1616 cards found [ 110.771770] k1pemey0: 0 Contec PCIe DIO6464 cards found [ 110.771771] k1pemey0: 0 DO cards found [ 110.771772] k1pemey0: *************************************************************************** [ 110.771773] k1pemey0: 1 RFM cards found [ 110.771774] k1pemey0: RFM 0 is a VMIC_0 module with Node ID 0 [ 110.771775] k1pemey0: address is 0xffffc9002ce00000 [ 110.771776] k1pemey0: *************************************************************************** [ 110.771777] k1pemey0: Initializing space for daqLib buffers [ 110.771778] k1pemey0: Epics burt restore is 0 [ 111.770821] k1pemey0: Epics burt restore is 0 [ 112.770843] k1pemey0: Epics burt restore is 0 [ 113.872978] CPU 5 is now offline [ 113.873086] k1pemey0: Sync source = 8 [ 113.873088] k1pemey0: Waiting for EPICS BURT Restore = 1 [ 113.874651] CPU 6 MCA banks CMCI:5 CMCI:6 CMCI:7 CMCI:9 CMCI:10 CMCI:11 CMCI:12 CMCI:17 CMCI:18 CMCI:19 CMCI:20 [ 113.933019] k1pemey0: Waiting for EPICS BURT 0 [ 113.933020] k1pemey0: BURT Restore Complete [ 113.933109] k1pemey0: Initialized servo control parameters. [ 113.934109] k1pemey0: DAQ Ex Min/Max = 1 28 [ 113.934110] k1pemey0: DAQ XEx Min/Max = 28 78 [ 113.934111] k1pemey0: DAQ Tp Min/Max = 10001 10082 [ 113.934112] k1pemey0: DAQ XTp Min/Max = 10082 10582 [ 113.934132] k1pemey0: Have 180 CDS epics integer and 24 USR epics integer channels [ 113.934134] k1pemey0: DAQ EPICS INT DATA is at 0xffffc90041026028 with size 816 [ 113.934135] k1pemey0: DAQ EPICS FLT DATA is at 0xffffc90041026358 [ 113.934137] k1pemey0: DAQ EPICS: Int = 204 Flt = 72 Filters = 297 Total = 573 Fast = 10 [ 113.934138] k1pemey0: DAQ EPICS: Number of Filter Module Xfers = 3 last = 27 [ 113.934139] k1pemey0: crc length epics = 2292 [ 113.934141] k1pemey0: xfer sizes = 1024 17 18164 18164 [ 113.934143] k1pemey0: Calling feCode() to initialize [ 113.934145] k1pemey0: waiting to sync 52416 [ 114.133633] k1pemey0: Synched 199680 [17367.894233] runscript.sh used greatest stack depth: 3656 bytes left [265747.127155] cksum used greatest stack depth: 3344 bytes left [18432363600.056070] k1pemey0: Setting stop_working_threads to 1 [18432363600.803363] k1pemey0: exiting from fe_code() [18432363601.055976] Will bring back CPU 5 [18432363602.056209] Booting Node 0 Processor 5 APIC 0x12 [18432363602.057324] smpboot cpu 5: start_ip = 99000 [18432363602.148903] Switched to NOHz mode on CPU #5 [18432363602.149392] Brought the CPU back up [18432363602.149393] k1pemey0: Just before returning from cleanup_module for k1pemey0 [18432363602.186037] k1caley: Setting stop_working_threads to 1 [18432363602.807874] k1caley: exiting from fe_code() [18432363603.185891] Will bring back CPU 4 [18432363604.186160] Booting Node 0 Processor 4 APIC 0x10 [18432363604.188180] smpboot cpu 4: start_ip = 99000 [18432363604.279814] Switched to NOHz mode on CPU #4 [18432363604.280161] Brought the CPU back up [18432363604.280162] k1caley: Just before returning from cleanup_module for k1caley [18432363604.327025] k1vistmsy: Setting stop_working_threads to 1 [18432363604.829515] k1vistmsy: exiting from fe_code() [18432363605.326801] Will bring back CPU 3 [18432363606.327048] Booting Node 0 Processor 3 APIC 0x6 [18432363606.329071] smpboot cpu 3: start_ip = 99000 [18432363606.420714] Switched to NOHz mode on CPU #3 [18432363606.421272] Brought the CPU back up [18432363606.421273] k1vistmsy: Just before returning from cleanup_module for k1vistmsy [18432363606.458084] k1tmsy: Setting stop_working_threads to 1 [18432363606.798770] k1tmsy: exiting from fe_code() [18432363607.457701] Will bring back CPU 2 [18432363608.457943] Booting Node 0 Processor 2 APIC 0x4 [18432363608.459945] smpboot cpu 2: start_ip = 99000 [18432363608.551624] Switched to NOHz mode on CPU #2 [18432363608.552175] Brought the CPU back up [18432363608.552176] k1tmsy: Just before returning from cleanup_module for k1tmsy [18432363608.764557] k1iopey0: Setting stop_working_threads to 1 [18432363608.793908] k1iopey0: exiting from fe_code() [18432363609.764441] Will bring back CPU 1 [18432363610.764849] Booting Node 0 Processor 1 APIC 0x2 [18432363610.766940] smpboot cpu 1: start_ip = 99000 [18432363610.858363] Switched to NOHz mode on CPU #1 [18432363610.858974] Brought the CPU back up [18432363610.858975] k1iopey0: Just before returning from cleanup_module for k1iopey0 [18432363621.074448] k1iopey0: startup time is 1320122499 [18432363621.074450] k1iopey0: cpu clock 3000056 [18432363621.074452] k1iopey0: EPICSM at 0x28900000 [18432363621.074453] k1iopey0: IPC at 0x2c98f000 [18432363621.074454] k1iopey0: IOMEM at 0x2c993000 size 0x33410 [18432363621.074456] k1iopey0: DAQSM at 0x1482a000 [18432363621.074457] k1iopey0: configured to use 7 cards [18432363621.074458] k1iopey0: Initializing PCI Modules [18432363621.074493] k1iopey0: ADC card on bus 19; device 4 prim 19 [18432363621.074494] k1iopey0: adc card on bus 19; device 4 prim 19 [18432363621.074508] k1iopey0: pci0 = 0xc7501000 [18432363621.074573] k1iopey0: pci2 = 0xc7500000 [18432363621.074579] k1iopey0: ADC I/O address=0xc7500000 0xffffc90013f8e000 [18432363621.074583] k1iopey0: BCR = 0x242e0 [18432363621.074595] k1iopey0: RAG = 0x117d8 [18432363621.074599] k1iopey0: BCR = 0x84260 [18432363621.502584] k1iopey0: SSC = 0x16 [18432363621.502587] k1iopey0: IDBC = 0x1f [18432363621.502595] k1iopey0: ADC card on bus 1b; device 0 prim 1b [18432363621.502596] k1iopey0: adc card on bus 1b; device 0 prim 1b [18432363621.502607] k1iopey0: pci0 = 0xc7401000 [18432363621.502615] k1iopey0: pci2 = 0xc7400000 [18432363621.502618] k1iopey0: ADC I/O address=0xc7400000 0xffffc90013f92000 [18432363621.502622] k1iopey0: BCR = 0x242e0 [18432363621.502635] k1iopey0: RAG = 0x117d8 [18432363621.502638] k1iopey0: BCR = 0x84260 [18432363621.930623] k1iopey0: SSC = 0x16 [18432363621.930626] k1iopey0: IDBC = 0x1f [18432363621.930637] k1iopey0: DAC card on bus 1f; device 4 prim 1f [18432363621.930638] k1iopey0: dac card on bus 1f; device 4 [18432363621.930649] k1iopey0: pci0 = 0xc7301000 [18432363621.930669] k1iopey0: dac pci2 = 0xc7300000 [18432363621.930673] k1iopey0: DAC I/O address=0xc7300000 0xffffc90013ff6000 [18432363621.930676] k1iopey0: DAC BCR = 0x30080 [18432363621.930799] k1iopey0: DAC BCR after init = 0x30080 [18432363621.930802] k1iopey0: DAC CSR = 0xffff [18432363621.930808] k1iopey0: DAC BOR = 0x3415 [18432363621.930816] k1iopey0: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [18432363621.930839] k1iopey0: DAC card on bus 21; device 4 prim 21 [18432363621.930840] k1iopey0: dac card on bus 21; device 4 [18432363621.930850] k1iopey0: pci0 = 0xc7201000 [18432363621.930857] k1iopey0: dac pci2 = 0xc7200000 [18432363621.930861] k1iopey0: DAC I/O address=0xc7200000 0xffffc90013ffe000 [18432363621.930864] k1iopey0: DAC BCR = 0x30080 [18432363621.930986] k1iopey0: DAC BCR after init = 0x30080 [18432363621.930989] k1iopey0: DAC CSR = 0xffff [18432363621.930996] k1iopey0: DAC BOR = 0x3415 [18432363621.931000] k1iopey0: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [18432363621.931022] k1iopey0: ADC card on bus 23; device 4 prim 23 [18432363621.931023] k1iopey0: adc card on bus 23; device 4 prim 23 [18432363621.931034] k1iopey0: pci0 = 0xc7101000 [18432363621.931040] k1iopey0: pci2 = 0xc7100000 [18432363621.931044] k1iopey0: ADC I/O address=0xc7100000 0xffffc90014002000 [18432363621.931048] k1iopey0: BCR = 0x242e0 [18432363621.931061] k1iopey0: RAG = 0x117d8 [18432363621.931064] k1iopey0: BCR = 0x84260 [18432363622.359051] k1iopey0: SSC = 0x16 [18432363622.359054] k1iopey0: IDBC = 0x1f [18432363622.359387] k1iopey0: Contec 1616 DIO card on bus 15; device 0 [18432363622.359391] k1iopey0: contec 1616 dio pci2 = 0x6001 [18432363622.359392] k1iopey0: contec 1616 diospace = 0x6000 [18432363622.359395] k1iopey0: contec dio pci2 card number= 0x0 [18432363622.359404] k1iopey0: Contec BO card on bus 17; device 0 [18432363622.359407] k1iopey0: contec dio pci2 = 0x5001 [18432363622.359408] k1iopey0: contec32L diospace = 0x5000 [18432363622.359412] k1iopey0: contec dio pci2 card number= 0xa [18432363622.359421] k1iopey0: 5565 RFM card on bus 85; device c [18432363622.366711] k1iopey0: RFM address is 0x4026531840x [18432363622.366713] k1iopey0: CSR address is 0xf8000000 [18432363622.366722] k1iopey0: Board id = 0x65 [18432363622.366725] k1iopey0: VMIC5565 set to single transfers [18432363622.366726] k1iopey0: VMIC5565 ROGUE MASTER 1 = OFF [18432363622.366728] k1iopey0: VMIC5565 ROGUE MASTER 0 = OFF [18432363622.366729] k1iopey0: VMIC5565 Memory size = 128MBytes [18432363622.366731] k1iopey0: DMA address is 0x4160753664x [18432363622.366736] k1iopey0: 5565DMA at 0xffffc90014006000 [18432363622.366737] k1iopey0: 5565 INTCR = 0x251723776x [18432363622.366739] k1iopey0: 5565 INTCR = 0x251723776x [18432363622.366741] k1iopey0: 5565 MODE = 0x132483x [18432363622.366742] k1iopey0: 5565 DESC = 0x9x [18432363622.366751] k1iopey0: TSYNC GPS card on bus 82; device 0 [18432363622.366754] k1iopey0: TSYNC PIC BASE 0 address = f8100000 [18432363622.366759] k1iopey0: Remapped 0xffffc90014008000 [18432363627.390722] k1iopey0: TSYNC receiving YEAR info [18432363627.390725] k1iopey0: date = 309 days 4:41:1320122505 [18432363627.390727] k1iopey0: bcd time = 1320122505 sec 615 milliseconds 89 microseconds 615084710 nanosec [18432363627.390728] k1iopey0: Board sync = 1 [18432363627.400725] k1iopey0: TSYNC receiving YEAR info [18432363627.400728] k1iopey0: date = 309 days 4:41:1320122505 [18432363627.400729] k1iopey0: bcd time = 1320122505 sec 625 milliseconds 102 microseconds 625098250 nanosec [18432363627.400730] k1iopey0: Board sync = 1 [18432363627.400732] k1iopey0: 9 PCI cards found [18432363627.400733] k1iopey0: *************************************************************************** [18432363627.400734] k1iopey0: 3 ADC cards found [18432363627.400735] k1iopey0: ADC 0 is a GSC_16AI64SSA module [18432363627.400736] k1iopey0: Channels = 64 [18432363627.400737] k1iopey0: Firmware Rev = 1 [18432363627.400737] [18432363627.400738] k1iopey0: ADC 1 is a GSC_16AI64SSA module [18432363627.400739] k1iopey0: Channels = 64 [18432363627.400740] k1iopey0: Firmware Rev = 545 [18432363627.400740] [18432363627.400741] k1iopey0: ADC 2 is a GSC_16AI64SSA module [18432363627.400742] k1iopey0: Channels = 64 [18432363627.400743] k1iopey0: Firmware Rev = 16 [18432363627.400743] [18432363627.400744] k1iopey0: *************************************************************************** [18432363627.400745] k1iopey0: 2 DAC cards found [18432363627.400746] k1iopey0: DAC 0 is a GSC_16AO16 module [18432363627.400747] k1iopey0: Channels = 16 [18432363627.400748] k1iopey0: Filters = None [18432363627.400748] k1iopey0: Output Type = Differential [18432363627.400749] k1iopey0: Firmware Rev = 18 [18432363627.400750] [18432363627.400751] k1iopey0: MASTER DAC SLOT 0 3 [18432363627.400751] k1iopey0: DAC 1 is a GSC_16AO16 module [18432363627.400752] k1iopey0: Channels = 16 [18432363627.400753] k1iopey0: Filters = None [18432363627.400753] k1iopey0: Output Type = Differential [18432363627.400754] k1iopey0: Firmware Rev = 18 [18432363627.400755] [18432363627.400755] k1iopey0: MASTER DAC SLOT 1 4 [18432363627.400756] k1iopey0: *************************************************************************** [18432363627.400758] k1iopey0: 0 DIO cards found [18432363627.400758] k1iopey0: *************************************************************************** [18432363627.400760] k1iopey0: 0 IIRO-8 Isolated DIO cards found [18432363627.400761] k1iopey0: *************************************************************************** [18432363627.400762] k1iopey0: 0 IIRO-16 Isolated DIO cards found [18432363627.400763] k1iopey0: *************************************************************************** [18432363627.400764] k1iopey0: 1 Contec 32ch PCIe DO cards found [18432363627.400765] k1iopey0: 1 Contec PCIe DIO1616 cards found [18432363627.400766] k1iopey0: 0 Contec PCIe DIO6464 cards found [18432363627.400767] k1iopey0: 2 DO cards found [18432363627.400768] k1iopey0: TDS controller 0 is at 0 [18432363627.400769] k1iopey0: Total of 7 I/O modules found and mapped [18432363627.400770] k1iopey0: *************************************************************************** [18432363627.400771] k1iopey0: 1 RFM cards found [18432363627.400773] k1iopey0: RFM 0 is a VMIC_5565 module with Node ID 48 [18432363627.400774] k1iopey0: address is 0xffffc90045080000 [18432363627.400775] k1iopey0: *************************************************************************** [18432363627.400776] k1iopey0: IRIG-B card found 2 [18432363627.400777] k1iopey0: *************************************************************************** [18432363627.400778] k1iopey0: Initializing space for daqLib buffers [18432363627.502411] CPU 1 is now offline [18432363627.502519] k1iopey0: Sync source = 4 [18432363627.502521] k1iopey0: Waiting for EPICS BURT Restore = 1 [18432363627.562167] k1iopey0: Waiting for EPICS BURT 0 [18432363627.562168] k1iopey0: BURT Restore Complete [18432363627.562177] k1iopey0: Initialized servo control parameters. [18432363627.563177] k1iopey0: DAQ Ex Min/Max = 1 3 [18432363627.563178] k1iopey0: DAQ XEx Min/Max = 3 53 [18432363627.563179] k1iopey0: DAQ Tp Min/Max = 10001 10007 [18432363627.563180] k1iopey0: DAQ XTp Min/Max = 10007 10507 [18432363627.563200] k1iopey0: Have 346 CDS epics integer and 0 USR epics integer channels [18432363627.563202] k1iopey0: DAQ EPICS INT DATA is at 0xffffc90028901028 with size 1384 [18432363627.563203] k1iopey0: DAQ EPICS FLT DATA is at 0xffffc90028901590 [18432363627.563204] k1iopey0: DAQ EPICS: Int = 346 Flt = 97 Filters = 22 Total = 465 Fast = 0 [18432363627.563206] k1iopey0: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [18432363627.563207] k1iopey0: crc length epics = 1860 [18432363627.563208] k1iopey0: xfer sizes = 4096 0 1860 1860 [18432363627.563210] k1iopey0: Calling feCode() to initialize [18432363627.563215] k1iopey0: ADC setup complete [18432363627.563216] k1iopey0: DAC setup complete [18432363627.563220] k1iopey0: writing BIO 0 [18432363627.643183] k1iopey0: writing DAC 0 [18432363627.643194] k1iopey0: writing DAC 1 [18432363627.643222] k1iopey0: Triggered the ADC [18432363638.784506] k1pemey0: startup time is 1320122517 [18432363638.784508] k1pemey0: cpu clock 3000056 [18432363638.784510] k1pemey0: EPICSM at 0x41025000 [18432363638.784511] k1pemey0: IPC at 0x2c98f000 [18432363638.784512] k1pemey0: IOMEM at 0x2c993000 size 0x33410 [18432363638.784513] k1pemey0: DAQSM at 0x248b2000 [18432363638.784514] k1pemey0: configured to use 2 cards [18432363638.784515] k1pemey0: Initializing PCI Modules [18432363638.784516] k1pemey0: 9 PCI cards found [18432363638.784517] k1pemey0: Found ADC at 0 0 [18432363638.784518] k1pemey0: Found ADC at 1 1 [18432363638.784519] k1pemey0: 2 PCI cards found [18432363638.784520] k1pemey0: *************************************************************************** [18432363638.784521] k1pemey0: 2 ADC cards found [18432363638.784522] k1pemey0: ADC 0 is a GSC_16AI64SSA module [18432363638.784523] k1pemey0: Channels = 64 [18432363638.784524] k1pemey0: Firmware Rev = 0 [18432363638.784524] [18432363638.784525] k1pemey0: ADC 1 is a GSC_16AI64SSA module [18432363638.784526] k1pemey0: Channels = 64 [18432363638.784527] k1pemey0: Firmware Rev = 1 [18432363638.784527] [18432363638.784528] k1pemey0: *************************************************************************** [18432363638.784529] k1pemey0: 0 DAC cards found [18432363638.784530] k1pemey0: *************************************************************************** [18432363638.784531] k1pemey0: 0 DIO cards found [18432363638.784532] k1pemey0: *************************************************************************** [18432363638.784533] k1pemey0: 0 IIRO-8 Isolated DIO cards found [18432363638.784534] k1pemey0: *************************************************************************** [18432363638.784535] k1pemey0: 0 IIRO-16 Isolated DIO cards found [18432363638.784536] k1pemey0: *************************************************************************** [18432363638.784538] k1pemey0: 0 Contec 32ch PCIe DO cards found [18432363638.784538] k1pemey0: 0 Contec PCIe DIO1616 cards found [18432363638.784539] k1pemey0: 0 Contec PCIe DIO6464 cards found [18432363638.784540] k1pemey0: 0 DO cards found [18432363638.784541] k1pemey0: *************************************************************************** [18432363638.784542] k1pemey0: 1 RFM cards found [18432363638.784543] k1pemey0: RFM 0 is a VMIC_0 module with Node ID 0 [18432363638.784544] k1pemey0: address is 0xffffc90045080000 [18432363638.784545] k1pemey0: *************************************************************************** [18432363638.784546] k1pemey0: Initializing space for daqLib buffers [18432363638.784548] k1pemey0: Epics burt restore is 0 [18432363639.784000] k1pemey0: Epics burt restore is 0 [18432363640.886180] CPU 5 is now offline [18432363640.886286] k1pemey0: Sync source = 8 [18432363640.886288] k1pemey0: Waiting for EPICS BURT Restore = 1 [18432363640.946230] k1pemey0: Waiting for EPICS BURT 0 [18432363640.946231] k1pemey0: BURT Restore Complete [18432363640.946317] k1pemey0: Initialized servo control parameters. [18432363640.947318] k1pemey0: DAQ Ex Min/Max = 1 28 [18432363640.947319] k1pemey0: DAQ XEx Min/Max = 28 78 [18432363640.947320] k1pemey0: DAQ Tp Min/Max = 10001 10082 [18432363640.947321] k1pemey0: DAQ XTp Min/Max = 10082 10582 [18432363640.947340] k1pemey0: Have 180 CDS epics integer and 24 USR epics integer channels [18432363640.947342] k1pemey0: DAQ EPICS INT DATA is at 0xffffc90041026028 with size 816 [18432363640.947343] k1pemey0: DAQ EPICS FLT DATA is at 0xffffc90041026358 [18432363640.947345] k1pemey0: DAQ EPICS: Int = 204 Flt = 72 Filters = 297 Total = 573 Fast = 10 [18432363640.947346] k1pemey0: DAQ EPICS: Number of Filter Module Xfers = 3 last = 27 [18432363640.947347] k1pemey0: crc length epics = 2292 [18432363640.947349] k1pemey0: xfer sizes = 1024 17 18164 18164 [18432363640.947351] k1pemey0: Calling feCode() to initialize [18432363640.947352] k1pemey0: waiting to sync 12096 [18432363641.761556] k1pemey0: Synched 814998 [18432363651.989517] k1caley: startup time is 1320122530 [18432363651.989519] k1caley: cpu clock 3000056 [18432363651.989521] k1caley: EPICSM at 0x3cf34000 [18432363651.989522] k1caley: IPC at 0x2c98f000 [18432363651.989523] k1caley: IOMEM at 0x2c993000 size 0x33410 [18432363651.989524] k1caley: DAQSM at 0x20890000 [18432363651.989525] k1caley: configured to use 3 cards [18432363651.989526] k1caley: Initializing PCI Modules [18432363651.989527] k1caley: 9 PCI cards found [18432363651.989528] k1caley: Found ADC at 0 0 [18432363651.989530] k1caley: Found DAC at 1 3 [18432363651.989531] k1caley: Found 32 DO CONTEC at 2 0x5000 [18432363651.989532] k1caley: 3 PCI cards found [18432363651.989533] k1caley: *************************************************************************** [18432363651.989534] k1caley: 1 ADC cards found [18432363651.989535] k1caley: ADC 0 is a GSC_16AI64SSA module [18432363651.989536] k1caley: Channels = 64 [18432363651.989537] k1caley: Firmware Rev = 0 [18432363651.989537] [18432363651.989538] k1caley: *************************************************************************** [18432363651.989539] k1caley: 1 DAC cards found [18432363651.989540] k1caley: DAC 0 is a GSC_16AO16 module [18432363651.989540] k1caley: Channels = 64 [18432363651.989541] k1caley: Filters = None [18432363651.989542] k1caley: Firmware Rev = 3 [18432363651.989543] [18432363651.989543] k1caley: *************************************************************************** [18432363651.989544] k1caley: 0 DIO cards found [18432363651.989545] k1caley: *************************************************************************** [18432363651.989546] k1caley: 0 IIRO-8 Isolated DIO cards found [18432363651.989547] k1caley: *************************************************************************** [18432363651.989549] k1caley: 0 IIRO-16 Isolated DIO cards found [18432363651.989550] k1caley: *************************************************************************** [18432363651.989551] k1caley: 1 Contec 32ch PCIe DO cards found [18432363651.989552] k1caley: 0 Contec PCIe DIO1616 cards found [18432363651.989552] k1caley: 0 Contec PCIe DIO6464 cards found [18432363651.989553] k1caley: 1 DO cards found [18432363651.989554] k1caley: *************************************************************************** [18432363651.989555] k1caley: 1 RFM cards found [18432363651.989556] k1caley: RFM 0 is a VMIC_0 module with Node ID 0 [18432363651.989557] k1caley: address is 0xffffc90045080000 [18432363651.989558] k1caley: *************************************************************************** [18432363651.989559] k1caley: Initializing space for daqLib buffers [18432363651.989561] k1caley: Epics burt restore is 0 [18432363652.989054] k1caley: Epics burt restore is 0 [18432363654.091206] CPU 4 is now offline [18432363654.091312] k1caley: Sync source = 8 [18432363654.091313] k1caley: Waiting for EPICS BURT Restore = 1 [18432363654.151255] k1caley: Waiting for EPICS BURT 0 [18432363654.151256] k1caley: BURT Restore Complete [18432363654.151673] k1caley: Initialized servo control parameters. [18432363654.152674] k1caley: DAQ Ex Min/Max = 1 134 [18432363654.152675] k1caley: DAQ XEx Min/Max = 134 184 [18432363654.152676] k1caley: DAQ Tp Min/Max = 10001 10400 [18432363654.152677] k1caley: DAQ XTp Min/Max = 10400 10900 [18432363654.152697] k1caley: Have 164 CDS epics integer and 23 USR epics integer channels [18432363654.152699] k1caley: Have int mem hole after user 656 92 [18432363654.152700] k1caley: DAQ EPICS INT DATA is at 0xffffc9003cf35028 with size 748 [18432363654.152701] k1caley: DAQ EPICS FLT DATA is at 0xffffc9003cf35318 [18432363654.152703] k1caley: DAQ EPICS: Int = 187 Flt = 386 Filters = 1463 Total = 2036 Fast = 20 [18432363654.152704] k1caley: DAQ EPICS: Number of Filter Module Xfers = 4 last = 33 [18432363654.152705] k1caley: crc length epics = 8144 [18432363654.152707] k1caley: xfer sizes = 1024 32 33360 33360 [18432363654.152713] k1caley: Calling feCode() to initialize [18432363654.152714] k1caley: size of data block = 0x80000 [18432363654.152715] k1caley: Dolphin num = 0 at 0x0 and 0x0 [18432363654.152726] k1caley: Setting card local=0 global = 0 channel=0 dac usage [18432363654.152728] k1caley: Setting card local=0 global = 0 channel=4 dac usage [18432363654.152729] k1caley: Setting card local=0 global = 0 channel=5 dac usage [18432363654.152730] k1caley: Setting card local=0 global = 0 channel=6 dac usage [18432363654.152731] k1caley: Setting card local=0 global = 0 channel=7 dac usage [18432363654.152732] k1caley: Setting card local=0 global = 0 channel=8 dac usage [18432363654.152733] k1caley: waiting to sync 26432 [18432363654.748824] k1caley: Synched 596671 [18432363665.189226] k1vistmsy: startup time is 1320122543 [18432363665.189228] k1vistmsy: cpu clock 3000056 [18432363665.189230] k1vistmsy: EPICSM at 0x38e91000 [18432363665.189231] k1vistmsy: IPC at 0x2c98f000 [18432363665.189232] k1vistmsy: IOMEM at 0x2c993000 size 0x33410 [18432363665.189233] k1vistmsy: DAQSM at 0x1c86e000 [18432363665.189234] k1vistmsy: configured to use 8 cards [18432363665.189235] k1vistmsy: Initializing PCI Modules [18432363665.189236] k1vistmsy: 9 PCI cards found [18432363665.189237] k1vistmsy: Found ADC at 0 0 [18432363665.189238] k1vistmsy: Found ADC at 1 1 [18432363665.189239] k1vistmsy: Found ADC at 2 2 [18432363665.189240] k1vistmsy: Found DAC at 3 4 [18432363665.189241] k1vistmsy: 4 PCI cards found [18432363665.189243] k1vistmsy: ERROR **** Did not find correct number of cards! Expected 8 and Found 4 [18432363665.189244] k1vistmsy: *************************************************************************** [18432363665.189245] k1vistmsy: 3 ADC cards found [18432363665.189246] k1vistmsy: ADC 0 is a GSC_16AI64SSA module [18432363665.189247] k1vistmsy: Channels = 64 [18432363665.189247] k1vistmsy: Firmware Rev = 0 [18432363665.189248] [18432363665.189249] k1vistmsy: ADC 1 is a GSC_16AI64SSA module [18432363665.189250] k1vistmsy: Channels = 64 [18432363665.189251] k1vistmsy: Firmware Rev = 1 [18432363665.189251] [18432363665.189252] k1vistmsy: ADC 2 is a GSC_16AI64SSA module [18432363665.189253] k1vistmsy: Channels = 64 [18432363665.189253] k1vistmsy: Firmware Rev = 2 [18432363665.189254] [18432363665.189255] k1vistmsy: *************************************************************************** [18432363665.189256] k1vistmsy: 1 DAC cards found [18432363665.189256] k1vistmsy: DAC 0 is a GSC_16AO16 module [18432363665.189257] k1vistmsy: Channels = 64 [18432363665.189258] k1vistmsy: Filters = None [18432363665.189259] k1vistmsy: Firmware Rev = 4 [18432363665.189259] [18432363665.189260] k1vistmsy: *************************************************************************** [18432363665.189261] k1vistmsy: 0 DIO cards found [18432363665.189262] k1vistmsy: *************************************************************************** [18432363665.189263] k1vistmsy: 0 IIRO-8 Isolated DIO cards found [18432363665.189264] k1vistmsy: *************************************************************************** [18432363665.189266] k1vistmsy: 0 IIRO-16 Isolated DIO cards found [18432363665.189267] k1vistmsy: *************************************************************************** [18432363665.189268] k1vistmsy: 0 Contec 32ch PCIe DO cards found [18432363665.189269] k1vistmsy: 0 Contec PCIe DIO1616 cards found [18432363665.189270] k1vistmsy: 0 Contec PCIe DIO6464 cards found [18432363665.189270] k1vistmsy: 0 DO cards found [18432363665.189271] k1vistmsy: *************************************************************************** [18432363665.189272] k1vistmsy: 1 RFM cards found [18432363665.189274] k1vistmsy: RFM 0 is a VMIC_0 module with Node ID 0 [18432363665.189275] k1vistmsy: address is 0xffffc90045080000 [18432363665.189275] k1vistmsy: *************************************************************************** [18432363665.189277] k1vistmsy: Initializing space for daqLib buffers [18432363665.189278] k1vistmsy: Epics burt restore is 0 [18432363666.189111] k1vistmsy: Epics burt restore is 0 [18432363667.291249] CPU 3 is now offline [18432363667.291355] k1vistmsy: Sync source = 8 [18432363667.291356] k1vistmsy: Waiting for EPICS BURT Restore = 1 [18432363667.351298] k1vistmsy: Waiting for EPICS BURT 0 [18432363667.351300] k1vistmsy: BURT Restore Complete [18432363667.351509] k1vistmsy: Initialized servo control parameters. [18432363667.352509] k1vistmsy: DAQ Ex Min/Max = 20001 20066 [18432363667.352510] k1vistmsy: DAQ XEx Min/Max = 20066 20116 [18432363667.352511] k1vistmsy: DAQ Tp Min/Max = 30001 30196 [18432363667.352512] k1vistmsy: DAQ XTp Min/Max = 30196 30696 [18432363667.352533] k1vistmsy: Have 294 CDS epics integer and 42 USR epics integer channels [18432363667.352535] k1vistmsy: DAQ EPICS INT DATA is at 0xffffc90038e92028 with size 1344 [18432363667.352536] k1vistmsy: DAQ EPICS FLT DATA is at 0xffffc90038e92568 [18432363667.352538] k1vistmsy: DAQ EPICS: Int = 336 Flt = 283 Filters = 715 Total = 1334 Fast = 18 [18432363667.352539] k1vistmsy: DAQ EPICS: Number of Filter Module Xfers = 3 last = 65 [18432363667.352540] k1vistmsy: crc length epics = 5336 [18432363667.352542] k1vistmsy: xfer sizes = 128 113 14552 14552 [18432363667.352545] k1vistmsy: Calling feCode() to initialize [18432363667.352546] k1vistmsy: size of data block = 0x80000 [18432363667.352547] k1vistmsy: Dolphin num = 0 at 0x0 and 0x0 [18432363667.352551] k1vistmsy: Setting card local=0 global = 1 channel=8 dac usage [18432363667.352552] k1vistmsy: Setting card local=0 global = 1 channel=9 dac usage [18432363667.352553] k1vistmsy: Setting card local=0 global = 1 channel=11 dac usage [18432363667.352554] k1vistmsy: Setting card local=0 global = 1 channel=12 dac usage [18432363667.352555] k1vistmsy: Setting card local=0 global = 1 channel=13 dac usage [18432363667.352557] k1vistmsy: Setting card local=0 global = 1 channel=14 dac usage [18432363667.352558] k1vistmsy: waiting to sync 40320 [18432363667.736091] k1vistmsy: Synched 383905 [18432363678.393166] k1tmsy: startup time is 1320122556 [18432363678.393168] k1tmsy: cpu clock 3000056 [18432363678.393170] k1tmsy: EPICSM at 0x34e01000 [18432363678.393171] k1tmsy: IPC at 0x2c98f000 [18432363678.393172] k1tmsy: IOMEM at 0x2c993000 size 0x33410 [18432363678.393174] k1tmsy: DAQSM at 0x1884c000 [18432363678.393175] k1tmsy: configured to use 3 cards [18432363678.393176] k1tmsy: Initializing PCI Modules [18432363678.393177] k1tmsy: 9 PCI cards found [18432363678.393178] k1tmsy: Found ADC at 0 0 [18432363678.393179] k1tmsy: Found ADC at 1 1 [18432363678.393180] k1tmsy: Found ADC at 2 2 [18432363678.393181] k1tmsy: 3 PCI cards found [18432363678.393182] k1tmsy: *************************************************************************** [18432363678.393184] k1tmsy: 3 ADC cards found [18432363678.393184] k1tmsy: ADC 0 is a GSC_16AI64SSA module [18432363678.393185] k1tmsy: Channels = 64 [18432363678.393186] k1tmsy: Firmware Rev = 0 [18432363678.393187] [18432363678.393187] k1tmsy: ADC 1 is a GSC_16AI64SSA module [18432363678.393188] k1tmsy: Channels = 64 [18432363678.393189] k1tmsy: Firmware Rev = 1 [18432363678.393190] [18432363678.393190] k1tmsy: ADC 2 is a GSC_16AI64SSA module [18432363678.393191] k1tmsy: Channels = 64 [18432363678.393192] k1tmsy: Firmware Rev = 2 [18432363678.393192] [18432363678.393193] k1tmsy: *************************************************************************** [18432363678.393194] k1tmsy: 0 DAC cards found [18432363678.393195] k1tmsy: *************************************************************************** [18432363678.393196] k1tmsy: 0 DIO cards found [18432363678.393197] k1tmsy: *************************************************************************** [18432363678.393199] k1tmsy: 0 IIRO-8 Isolated DIO cards found [18432363678.393200] k1tmsy: *************************************************************************** [18432363678.393201] k1tmsy: 0 IIRO-16 Isolated DIO cards found [18432363678.393202] k1tmsy: *************************************************************************** [18432363678.393203] k1tmsy: 0 Contec 32ch PCIe DO cards found [18432363678.393204] k1tmsy: 0 Contec PCIe DIO1616 cards found [18432363678.393205] k1tmsy: 0 Contec PCIe DIO6464 cards found [18432363678.393206] k1tmsy: 0 DO cards found [18432363678.393207] k1tmsy: *************************************************************************** [18432363678.393208] k1tmsy: 1 RFM cards found [18432363678.393209] k1tmsy: RFM 0 is a VMIC_0 module with Node ID 0 [18432363678.393210] k1tmsy: address is 0xffffc90045080000 [18432363678.393211] k1tmsy: *************************************************************************** [18432363678.393212] k1tmsy: Initializing space for daqLib buffers [18432363678.393214] k1tmsy: Epics burt restore is 0 [18432363679.393166] k1tmsy: Epics burt restore is 0 [18432363680.497224] CPU 2 is now offline [18432363680.497331] k1tmsy: Sync source = 8 [18432363680.497333] k1tmsy: Waiting for EPICS BURT Restore = 1 [18432363680.557274] k1tmsy: Waiting for EPICS BURT 0 [18432363680.557275] k1tmsy: BURT Restore Complete [18432363680.557427] k1tmsy: Initialized servo control parameters. [18432363680.558428] k1tmsy: DAQ Ex Min/Max = 1 49 [18432363680.558429] k1tmsy: DAQ XEx Min/Max = 49 99 [18432363680.558430] k1tmsy: DAQ Tp Min/Max = 10001 10145 [18432363680.558431] k1tmsy: DAQ XTp Min/Max = 10145 10645 [18432363680.558452] k1tmsy: Have 245 CDS epics integer and 28 USR epics integer channels [18432363680.558453] k1tmsy: Have int mem hole after CDS 980 112 [18432363680.558455] k1tmsy: Have mem holes after CDS 980 112 [18432363680.558455] Need to cpy ints twice - size 1 = 980 size 2 = 112 [18432363680.558457] k1tmsy: DAQ EPICS INT DATA is at 0xffffc90034e02028 with size 1092 [18432363680.558458] k1tmsy: DAQ EPICS FLT DATA is at 0xffffc90034e02470 [18432363680.558459] k1tmsy: DAQ EPICS: Int = 273 Flt = 70 Filters = 528 Total = 871 Fast = 21 [18432363680.558461] k1tmsy: DAQ EPICS: Number of Filter Module Xfers = 3 last = 48 [18432363680.558462] k1tmsy: crc length epics = 3484 [18432363680.558464] k1tmsy: xfer sizes = 1024 11 12188 12188 [18432363680.558467] k1tmsy: Calling feCode() to initialize [18432363680.558469] k1tmsy: size of data block = 0x80000 [18432363680.558470] k1tmsy: Dolphin num = 0 at 0x0 and 0x0 [18432363680.558472] k1tmsy: waiting to sync 54656 [18432363680.723356] k1tmsy: Synched 165044 [18432956855.262438] k1caley: Setting stop_working_threads to 1 [18432956856.208263] k1caley: exiting from fe_code() [18432956856.262117] Will bring back CPU 4 [18432956857.262350] Booting Node 0 Processor 4 APIC 0x10 [18432956857.278817] smpboot cpu 4: start_ip = 99000 [18432956857.370793] Brought the CPU back up [18432956857.370795] k1caley: Just before returning from cleanup_module for k1caley [18432956857.371025] Switched to NOHz mode on CPU #4 [18432956867.583711] k1caley: startup time is 1320716327 [18432956867.583713] k1caley: cpu clock 3000056 [18432956867.583715] k1caley: EPICSM at 0x3cf34000 [18432956867.583716] k1caley: IPC at 0x2c98f000 [18432956867.583717] k1caley: IOMEM at 0x2c993000 size 0x33410 [18432956867.583718] k1caley: DAQSM at 0x20890000 [18432956867.583719] k1caley: configured to use 3 cards [18432956867.583721] k1caley: Initializing PCI Modules [18432956867.583722] k1caley: 9 PCI cards found [18432956867.583723] k1caley: Found ADC at 0 0 [18432956867.583724] k1caley: Found DAC at 1 3 [18432956867.583725] k1caley: Found 32 DO CONTEC at 2 0x5000 [18432956867.583727] k1caley: 3 PCI cards found [18432956867.583728] k1caley: *************************************************************************** [18432956867.583729] k1caley: 1 ADC cards found [18432956867.583730] k1caley: ADC 0 is a GSC_16AI64SSA module [18432956867.583731] k1caley: Channels = 64 [18432956867.583732] k1caley: Firmware Rev = 0 [18432956867.583732] [18432956867.583733] k1caley: *************************************************************************** [18432956867.583734] k1caley: 1 DAC cards found [18432956867.583735] k1caley: DAC 0 is a GSC_16AO16 module [18432956867.583736] k1caley: Channels = 64 [18432956867.583737] k1caley: Filters = None [18432956867.583737] k1caley: Firmware Rev = 3 [18432956867.583738] [18432956867.583739] k1caley: *************************************************************************** [18432956867.583740] k1caley: 0 DIO cards found [18432956867.583741] k1caley: *************************************************************************** [18432956867.583742] k1caley: 0 IIRO-8 Isolated DIO cards found [18432956867.583743] k1caley: *************************************************************************** [18432956867.583744] k1caley: 0 IIRO-16 Isolated DIO cards found [18432956867.583745] k1caley: *************************************************************************** [18432956867.583747] k1caley: 1 Contec 32ch PCIe DO cards found [18432956867.583747] k1caley: 0 Contec PCIe DIO1616 cards found [18432956867.583748] k1caley: 0 Contec PCIe DIO6464 cards found [18432956867.583749] k1caley: 1 DO cards found [18432956867.583750] k1caley: *************************************************************************** [18432956867.583751] k1caley: 1 RFM cards found [18432956867.583752] k1caley: RFM 0 is a VMIC_0 module with Node ID 0 [18432956867.583753] k1caley: address is 0xffffc90045080000 [18432956867.583754] k1caley: *************************************************************************** [18432956867.583755] k1caley: Initializing space for daqLib buffers [18432956867.583757] k1caley: Epics burt restore is 0 [18432956868.583036] k1caley: Epics burt restore is 0 [18432956869.689760] CPU 4 is now offline [18432956869.689869] k1caley: Sync source = 8 [18432956869.689870] k1caley: Waiting for EPICS BURT Restore = 1 [18432956869.749812] k1caley: Waiting for EPICS BURT 0 [18432956869.749813] k1caley: BURT Restore Complete [18432956869.750231] k1caley: Initialized servo control parameters. [18432956869.751232] k1caley: DAQ Ex Min/Max = 1 134 [18432956869.751233] k1caley: DAQ XEx Min/Max = 134 184 [18432956869.751234] k1caley: DAQ Tp Min/Max = 10001 10400 [18432956869.751235] k1caley: DAQ XTp Min/Max = 10400 10900 [18432956869.751255] k1caley: Have 164 CDS epics integer and 23 USR epics integer channels [18432956869.751256] k1caley: Have int mem hole after user 656 92 [18432956869.751258] k1caley: DAQ EPICS INT DATA is at 0xffffc9003cf35028 with size 748 [18432956869.751259] k1caley: DAQ EPICS FLT DATA is at 0xffffc9003cf35318 [18432956869.751260] k1caley: DAQ EPICS: Int = 187 Flt = 386 Filters = 1463 Total = 2036 Fast = 20 [18432956869.751262] k1caley: DAQ EPICS: Number of Filter Module Xfers = 4 last = 33 [18432956869.751263] k1caley: crc length epics = 8144 [18432956869.751265] k1caley: xfer sizes = 1024 32 33360 33360 [18432956869.751270] k1caley: Calling feCode() to initialize [18432956869.751272] k1caley: size of data block = 0x80000 [18432956869.751273] k1caley: Dolphin num = 0 at 0x0 and 0x0 [18432956869.751282] k1caley: Setting card local=0 global = 0 channel=0 dac usage [18432956869.751283] k1caley: Setting card local=0 global = 0 channel=4 dac usage [18432956869.751284] k1caley: Setting card local=0 global = 0 channel=5 dac usage [18432956869.751285] k1caley: Setting card local=0 global = 0 channel=6 dac usage [18432956869.751287] k1caley: Setting card local=0 global = 0 channel=7 dac usage [18432956869.751288] k1caley: Setting card local=0 global = 0 channel=8 dac usage [18432956869.751289] k1caley: waiting to sync 36928 [18432956870.186435] k1caley: Synched 435568