[ 0.000000] Initializing cgroup subsys cpuset [ 0.000000] Initializing cgroup subsys cpu [ 0.000000] Linux version 3.0.8 (controls@master) (gcc version 4.4.3 (Gentoo 4.4.3-r2 p1.2) ) #1 SMP Mon Jun 17 16:45:04 JST 2013 [ 0.000000] Command line: ip=dhcp root=/dev/nfs nfsroot=10.68.10.100:/diskless/root BOOT_IMAGE=kernel-3.0.8-cs [ 0.000000] BIOS-provided physical RAM map: [ 0.000000] BIOS-e820: 0000000000000000 - 000000000009ec00 (usable) [ 0.000000] BIOS-e820: 000000000009ec00 - 00000000000a0000 (reserved) [ 0.000000] BIOS-e820: 00000000000e0000 - 0000000000100000 (reserved) [ 0.000000] BIOS-e820: 0000000000100000 - 0000000078f0f000 (usable) [ 0.000000] BIOS-e820: 0000000078f0f000 - 000000007985f000 (reserved) [ 0.000000] BIOS-e820: 000000007985f000 - 0000000079d28000 (ACPI NVS) [ 0.000000] BIOS-e820: 0000000079d28000 - 0000000090000000 (reserved) [ 0.000000] BIOS-e820: 00000000fed1c000 - 00000000fed45000 (reserved) [ 0.000000] BIOS-e820: 00000000ff000000 - 0000000100000000 (reserved) [ 0.000000] BIOS-e820: 0000000100000000 - 0000001080000000 (usable) [ 0.000000] NX (Execute Disable) protection: active [ 0.000000] DMI 3.0 present. [ 0.000000] DMI: Supermicro SYS-5028R-WR/X10SRW-F, BIOS 3.1 06/06/2018 [ 0.000000] e820 update range: 0000000000000000 - 0000000000010000 (usable) ==> (reserved) [ 0.000000] e820 remove range: 00000000000a0000 - 0000000000100000 (usable) [ 0.000000] No AGP bridge found [ 0.000000] last_pfn = 0x1080000 max_arch_pfn = 0x400000000 [ 0.000000] MTRR default type: write-back [ 0.000000] MTRR fixed ranges enabled: [ 0.000000] 00000-9FFFF write-back [ 0.000000] A0000-BFFFF uncachable [ 0.000000] C0000-FFFFF write-protect [ 0.000000] MTRR variable ranges enabled: [ 0.000000] 0 base 000080000000 mask 3FFF80000000 uncachable [ 0.000000] 1 base 380000000000 mask 3FC000000000 uncachable [ 0.000000] 2 disabled [ 0.000000] 3 disabled [ 0.000000] 4 disabled [ 0.000000] 5 disabled [ 0.000000] 6 disabled [ 0.000000] 7 disabled [ 0.000000] 8 disabled [ 0.000000] 9 disabled [ 0.000000] x86 PAT enabled: cpu 0, old 0x7040600070406, new 0x7010600070106 [ 0.000000] last_pfn = 0x78f0f max_arch_pfn = 0x400000000 [ 0.000000] found SMP MP-table at [ffff8800000fce60] fce60 [ 0.000000] initial memory mapped : 0 - 20000000 [ 0.000000] Base memory trampoline at [ffff880000099000] 99000 size 20480 [ 0.000000] Using GB pages for direct mapping [ 0.000000] init_memory_mapping: 0000000000000000-0000000078f0f000 [ 0.000000] 0000000000 - 0040000000 page 1G [ 0.000000] 0040000000 - 0078e00000 page 2M [ 0.000000] 0078e00000 - 0078f0f000 page 4k [ 0.000000] kernel direct mapping tables up to 78f0f000 @ 1fffd000-20000000 [ 0.000000] init_memory_mapping: 0000000100000000-0000001080000000 [ 0.000000] 0100000000 - 1080000000 page 1G [ 0.000000] kernel direct mapping tables up to 1080000000 @ 78f0e000-78f0f000 [ 0.000000] ACPI: RSDP 00000000000f05b0 00024 (v02 SUPERM) [ 0.000000] ACPI: XSDT 000000007985f088 00094 (v01 01072009 AMI 00010013) [ 0.000000] ACPI: FACP 0000000079890b28 0010C (v05 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI Warning: FADT (revision 5) is longer than ACPI 2.0 version, truncating length 268 to 244 (20110413/tbfadt-288) [ 0.000000] ACPI: DSDT 000000007985f1b8 31970 (v02 SUPERM SMCI--MB 01072009 INTL 20091013) [ 0.000000] ACPI: FACS 0000000079d26f80 00040 [ 0.000000] ACPI: APIC 0000000079890c38 000AC (v03 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: FPDT 0000000079890ce8 00044 (v01 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: FIDT 0000000079890d30 0009C (v01 SUPERM SMCI--MB 01072009 AMI 00010013) [ 0.000000] ACPI: SPMI 0000000079890dd0 00041 (v05 SUPERM SMCI--MB 00000000 AMI. 00000000) [ 0.000000] ACPI: MCFG 0000000079890e18 0003C (v01 SUPERM SMCI--MB 01072009 MSFT 00000097) [ 0.000000] ACPI: UEFI 0000000079890e58 00042 (v01 SUPERM SMCI--MB 01072009 00000000) [ 0.000000] ACPI: NFIT 0000000079890ea0 18028 (v01 00000000 00000000) [ 0.000000] ACPI: WDDT 00000000798a8ec8 00040 (v01 SUPERM SMCI--MB 00000000 INTL 20091013) [ 0.000000] ACPI: SSDT 00000000798a8f08 17141 (v02 SUPERM PmMgt 00000001 INTL 20120913) [ 0.000000] ACPI: NITR 00000000798c0050 00071 (v02 SUPERM SMCI--MB 00000001 INTL 20091013) [ 0.000000] ACPI: SSDT 00000000798c00c8 0264C (v02 SUPERM SpsNm 00000002 INTL 20120913) [ 0.000000] ACPI: SSDT 00000000798c2718 00064 (v02 SUPERM SpsNvs 00000002 INTL 20120913) [ 0.000000] ACPI: PRAD 00000000798c2780 00102 (v02 SUPERM SMCI--MB 00000002 INTL 20120913) [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] No NUMA configuration found [ 0.000000] Faking a node at 0000000000000000-0000001080000000 [ 0.000000] Initmem setup node 0 0000000000000000-0000001080000000 [ 0.000000] NODE_DATA [000000107fffb000 - 000000107fffffff] [ 0.000000] [ffffea0000000000-ffffea0039bfffff] PMD -> [ffff88103f600000-ffff8810775fffff] on node 0 [ 0.000000] Zone PFN ranges: [ 0.000000] DMA 0x00000010 -> 0x00001000 [ 0.000000] DMA32 0x00001000 -> 0x00100000 [ 0.000000] Normal 0x00100000 -> 0x01080000 [ 0.000000] Movable zone start PFN for each node [ 0.000000] early_node_map[3] active PFN ranges [ 0.000000] 0: 0x00000010 -> 0x0000009e [ 0.000000] 0: 0x00000100 -> 0x00078f0f [ 0.000000] 0: 0x00100000 -> 0x01080000 [ 0.000000] On node 0 totalpages: 16748189 [ 0.000000] DMA zone: 56 pages used for memmap [ 0.000000] DMA zone: 5 pages reserved [ 0.000000] DMA zone: 3921 pages, LIFO batch:0 [ 0.000000] DMA32 zone: 14280 pages used for memmap [ 0.000000] DMA32 zone: 476999 pages, LIFO batch:31 [ 0.000000] Normal zone: 222208 pages used for memmap [ 0.000000] Normal zone: 16030720 pages, LIFO batch:31 [ 0.000000] ACPI: PM-Timer IO Port: 0x408 [ 0.000000] ACPI: Local APIC address 0xfee00000 [ 0.000000] ACPI: LAPIC (acpi_id[0x00] lapic_id[0x00] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x02] lapic_id[0x02] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x04] lapic_id[0x04] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x06] lapic_id[0x06] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x08] lapic_id[0x08] enabled) [ 0.000000] ACPI: LAPIC (acpi_id[0x0a] lapic_id[0x0a] enabled) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x00] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x02] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x04] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x06] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x08] high edge lint[0x1]) [ 0.000000] ACPI: LAPIC_NMI (acpi_id[0x0a] high edge lint[0x1]) [ 0.000000] ACPI: IOAPIC (id[0x01] address[0xfec00000] gsi_base[0]) [ 0.000000] IOAPIC[0]: apic_id 1, version 32, address 0xfec00000, GSI 0-23 [ 0.000000] ACPI: IOAPIC (id[0x02] address[0xfec01000] gsi_base[24]) [ 0.000000] IOAPIC[1]: apic_id 2, version 32, address 0xfec01000, GSI 24-47 [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 0 global_irq 2 dfl dfl) [ 0.000000] ACPI: INT_SRC_OVR (bus 0 bus_irq 9 global_irq 9 high level) [ 0.000000] ACPI: IRQ0 used by override. [ 0.000000] ACPI: IRQ2 used by override. [ 0.000000] ACPI: IRQ9 used by override. [ 0.000000] Using ACPI (MADT) for SMP configuration information [ 0.000000] SMP: Allowing 6 CPUs, 0 hotplug CPUs [ 0.000000] nr_irqs_gsi: 64 [ 0.000000] PM: Registered nosave memory: 000000000009e000 - 000000000009f000 [ 0.000000] PM: Registered nosave memory: 000000000009f000 - 00000000000a0000 [ 0.000000] PM: Registered nosave memory: 00000000000a0000 - 00000000000e0000 [ 0.000000] PM: Registered nosave memory: 00000000000e0000 - 0000000000100000 [ 0.000000] PM: Registered nosave memory: 0000000078f0f000 - 000000007985f000 [ 0.000000] PM: Registered nosave memory: 000000007985f000 - 0000000079d28000 [ 0.000000] PM: Registered nosave memory: 0000000079d28000 - 0000000090000000 [ 0.000000] PM: Registered nosave memory: 0000000090000000 - 00000000fed1c000 [ 0.000000] PM: Registered nosave memory: 00000000fed1c000 - 00000000fed45000 [ 0.000000] PM: Registered nosave memory: 00000000fed45000 - 00000000ff000000 [ 0.000000] PM: Registered nosave memory: 00000000ff000000 - 0000000100000000 [ 0.000000] Allocating PCI resources starting at 90000000 (gap: 90000000:6ed1c000) [ 0.000000] setup_percpu: NR_CPUS:64 nr_cpumask_bits:64 nr_cpu_ids:6 nr_node_ids:1 [ 0.000000] PERCPU: Embedded 25 pages/cpu @ffff88107fc00000 s69824 r8192 d24384 u262144 [ 0.000000] pcpu-alloc: s69824 r8192 d24384 u262144 alloc=1*2097152 [ 0.000000] pcpu-alloc: [0] 0 1 2 3 4 5 - - [ 0.000000] Built 1 zonelists in Zone order, mobility grouping on. Total pages: 16511640 [ 0.000000] Policy zone: Normal [ 0.000000] Kernel command line: ip=dhcp root=/dev/nfs nfsroot=10.68.10.100:/diskless/root BOOT_IMAGE=kernel-3.0.8-cs [ 0.000000] PID hash table entries: 4096 (order: 3, 32768 bytes) [ 0.000000] xsave/xrstor: enabled xstate_bv 0x7, cntxt size 0x340 [ 0.000000] Checking aperture... [ 0.000000] No AGP bridge found [ 0.000000] Calgary: detecting Calgary via BIOS EBDA area [ 0.000000] Calgary: Unable to locate Rio Grande table in EBDA - bailing! [ 0.000000] Memory: 65996128k/69206016k available (5398k kernel code, 2213260k absent, 996628k reserved, 5343k data, 628k init) [ 0.000000] SLUB: Genslabs=15, HWalign=64, Order=0-3, MinObjects=0, CPUs=6, Nodes=1 [ 0.000000] Hierarchical RCU implementation. [ 0.000000] NR_IRQS:4352 nr_irqs:1136 16 [ 0.000000] Extended CMOS year: 2000 [ 0.000000] Console: colour VGA+ 80x25 [ 0.000000] console [tty0] enabled [ 0.001000] Fast TSC calibration using PIT [ 0.002000] Detected 3599.825 MHz processor. [ 0.000001] Calibrating delay loop (skipped), value calculated using timer frequency.. 7199.65 BogoMIPS (lpj=3599825) [ 0.000685] pid_max: default: 32768 minimum: 301 [ 0.004165] Dentry cache hash table entries: 8388608 (order: 14, 67108864 bytes) [ 0.015632] Inode-cache hash table entries: 4194304 (order: 13, 33554432 bytes) [ 0.020575] Mount-cache hash table entries: 256 [ 0.020983] Initializing cgroup subsys cpuacct [ 0.021328] Initializing cgroup subsys freezer [ 0.021678] CPU: Physical Processor ID: 0 [ 0.022013] CPU: Processor Core ID: 0 [ 0.022356] mce: CPU supports 22 MCE banks [ 0.022717] CPU0: Thermal monitoring enabled (TM1) [ 0.023119] ACPI: Core revision 20110413 [ 0.039374] ..TIMER: vector=0x30 apic1=0 pin1=2 apic2=-1 pin2=-1 [ 0.049703] CPU0: Intel(R) Xeon(R) CPU E5-1650 v4 @ 3.60GHz stepping 01 [ 0.151101] Performance Events: no PEBS fmt2+, generic architected perfmon, Intel PMU driver. [ 0.151896] ... version: 3 [ 0.152233] ... bit width: 48 [ 0.152569] ... generic registers: 8 [ 0.152904] ... value mask: 0000ffffffffffff [ 0.153244] ... max period: 000000007fffffff [ 0.153582] ... fixed-purpose events: 3 [ 0.153919] ... event mask: 00000007000000ff [ 0.154325] Booting Node 0, Processors #1 [ 0.154454] smpboot cpu 1: start_ip = 99000 [ 0.245063] #2 [ 0.245128] smpboot cpu 2: start_ip = 99000 [ 0.335939] #3 [ 0.336004] smpboot cpu 3: start_ip = 99000 [ 0.426815] #4 [ 0.426880] smpboot cpu 4: start_ip = 99000 [ 0.517585] #5 Ok. [ 0.517919] smpboot cpu 5: start_ip = 99000 [ 0.608464] Brought up 6 CPUs [ 0.608798] Total of 6 processors activated (43194.14 BogoMIPS). [ 0.612358] kworker/u:0 used greatest stack depth: 5760 bytes left [ 0.612465] PM: Registering ACPI NVS region at 7985f000 (5017600 bytes) [ 0.612591] Time: 1:02:22 Date: 01/21/22 [ 0.612612] NET: Registered protocol family 16 [ 0.613867] ACPI FADT declares the system doesn't support PCIe ASPM, so disable it [ 0.614481] ACPI: bus type pci registered [ 0.614861] PCI: MMCONFIG for domain 0000 [bus 00-ff] at [mem 0x80000000-0x8fffffff] (base 0x80000000) [ 0.615478] PCI: MMCONFIG at [mem 0x80000000-0x8fffffff] reserved in E820 [ 0.624046] PCI: Using configuration type 1 for base access [ 0.628237] bio: create slab at 0 [ 0.634544] ACPI: EC: Look up EC in DSDT [ 0.649083] [Firmware Bug]: ACPI: BIOS _OSI(Linux) query ignored [ 0.713815] ACPI: Interpreter enabled [ 0.714152] ACPI: (supports S0 S4 S5) [ 0.714674] ACPI: BIOS offers _GTS [ 0.715008] ACPI: If "acpi.gts=1" improves suspend, please notify linux-acpi@vger.kernel.org [ 0.715622] ACPI: Using IOAPIC for interrupt routing [ 0.728459] ACPI: No dock devices found. [ 0.728796] PCI: Using host bridge windows from ACPI; if necessary, use "pci=nocrs" and report a bug [ 1.727501] ACPI: PCI Root Bridge [UNC0] (domain 0000 [bus ff]) [ 1.727899] pci 0000:ff:0b.0: [8086:6f81] type 0 class 0x000880 [ 1.727924] pci 0000:ff:0b.1: [8086:6f36] type 0 class 0x001101 [ 1.727945] pci 0000:ff:0b.2: [8086:6f37] type 0 class 0x001101 [ 1.727965] pci 0000:ff:0b.3: [8086:6f76] type 0 class 0x000880 [ 1.727987] pci 0000:ff:0c.0: [8086:6fe0] type 0 class 0x000880 [ 1.728008] pci 0000:ff:0c.1: [8086:6fe1] type 0 class 0x000880 [ 1.728027] pci 0000:ff:0c.2: [8086:6fe2] type 0 class 0x000880 [ 1.728047] pci 0000:ff:0c.3: [8086:6fe3] type 0 class 0x000880 [ 1.728069] pci 0000:ff:0c.4: [8086:6fe4] type 0 class 0x000880 [ 1.728089] pci 0000:ff:0c.5: [8086:6fe5] type 0 class 0x000880 [ 1.728111] pci 0000:ff:0f.0: [8086:6ff8] type 0 class 0x000880 [ 1.728131] pci 0000:ff:0f.1: [8086:6ff9] type 0 class 0x000880 [ 1.728152] pci 0000:ff:0f.4: [8086:6ffc] type 0 class 0x000880 [ 1.728173] pci 0000:ff:0f.5: [8086:6ffd] type 0 class 0x000880 [ 1.728193] pci 0000:ff:0f.6: [8086:6ffe] type 0 class 0x000880 [ 1.728214] pci 0000:ff:10.0: [8086:6f1d] type 0 class 0x000880 [ 1.728236] pci 0000:ff:10.1: [8086:6f34] type 0 class 0x001101 [ 1.728257] pci 0000:ff:10.5: [8086:6f1e] type 0 class 0x000880 [ 1.728276] pci 0000:ff:10.6: [8086:6f7d] type 0 class 0x001101 [ 1.728295] pci 0000:ff:10.7: [8086:6f1f] type 0 class 0x000880 [ 1.728315] pci 0000:ff:12.0: [8086:6fa0] type 0 class 0x000880 [ 1.728322] pci 0000:ff:12.0: reg 14: [mem 0x00000000-0x0000000f] [ 1.728326] pci 0000:ff:12.0: reg 18: [mem 0x00000000-0x0000003f] [ 1.728330] pci 0000:ff:12.0: reg 1c: [mem 0x00000000-0x0000000f] [ 1.728333] pci 0000:ff:12.0: reg 20: [mem 0x00000000-0x0000003f] [ 1.728337] pci 0000:ff:12.0: reg 24: [mem 0x00000000-0x0000000f] [ 1.728344] pci 0000:ff:12.1: [8086:6f30] type 0 class 0x001101 [ 1.728372] pci 0000:ff:13.0: [8086:6fa8] type 0 class 0x000880 [ 1.728401] pci 0000:ff:13.1: [8086:6f71] type 0 class 0x000880 [ 1.728431] pci 0000:ff:13.2: [8086:6faa] type 0 class 0x000880 [ 1.728460] pci 0000:ff:13.3: [8086:6fab] type 0 class 0x000880 [ 1.728489] pci 0000:ff:13.4: [8086:6fac] type 0 class 0x000880 [ 1.728516] pci 0000:ff:13.5: [8086:6fad] type 0 class 0x000880 [ 1.728542] pci 0000:ff:13.6: [8086:6fae] type 0 class 0x000880 [ 1.728564] pci 0000:ff:13.7: [8086:6faf] type 0 class 0x000880 [ 1.728588] pci 0000:ff:14.0: [8086:6fb0] type 0 class 0x000880 [ 1.728615] pci 0000:ff:14.1: [8086:6fb1] type 0 class 0x000880 [ 1.728644] pci 0000:ff:14.2: [8086:6fb2] type 0 class 0x000880 [ 1.728671] pci 0000:ff:14.3: [8086:6fb3] type 0 class 0x000880 [ 1.728697] pci 0000:ff:14.4: [8086:6fbc] type 0 class 0x000880 [ 1.728720] pci 0000:ff:14.5: [8086:6fbd] type 0 class 0x000880 [ 1.728742] pci 0000:ff:14.6: [8086:6fbe] type 0 class 0x000880 [ 1.728764] pci 0000:ff:14.7: [8086:6fbf] type 0 class 0x000880 [ 1.728787] pci 0000:ff:15.0: [8086:6fb4] type 0 class 0x000880 [ 1.728815] pci 0000:ff:15.1: [8086:6fb5] type 0 class 0x000880 [ 1.728843] pci 0000:ff:15.2: [8086:6fb6] type 0 class 0x000880 [ 1.728870] pci 0000:ff:15.3: [8086:6fb7] type 0 class 0x000880 [ 1.728899] pci 0000:ff:16.0: [8086:6f68] type 0 class 0x000880 [ 1.728925] pci 0000:ff:16.6: [8086:6f6e] type 0 class 0x000880 [ 1.728947] pci 0000:ff:16.7: [8086:6f6f] type 0 class 0x000880 [ 1.728970] pci 0000:ff:17.0: [8086:6fd0] type 0 class 0x000880 [ 1.728995] pci 0000:ff:17.4: [8086:6fb8] type 0 class 0x000880 [ 1.729017] pci 0000:ff:17.5: [8086:6fb9] type 0 class 0x000880 [ 1.729040] pci 0000:ff:17.6: [8086:6fba] type 0 class 0x000880 [ 1.729063] pci 0000:ff:17.7: [8086:6fbb] type 0 class 0x000880 [ 1.729089] pci 0000:ff:1e.0: [8086:6f98] type 0 class 0x000880 [ 1.729109] pci 0000:ff:1e.1: [8086:6f99] type 0 class 0x000880 [ 1.729130] pci 0000:ff:1e.2: [8086:6f9a] type 0 class 0x000880 [ 1.729150] pci 0000:ff:1e.3: [8086:6fc0] type 0 class 0x000880 [ 1.729155] pci 0000:ff:1e.3: reg 10: [mem 0x00000020-0x0000003f 64bit] [ 1.729171] pci 0000:ff:1e.4: [8086:6f9c] type 0 class 0x000880 [ 1.729194] pci 0000:ff:1f.0: [8086:6f88] type 0 class 0x000880 [ 1.729217] pci 0000:ff:1f.2: [8086:6f8a] type 0 class 0x000880 [ 1.729242] ACPI: PCI Interrupt Routing Table [\_SB_.UNC0._PRT] [ 1.730872] pci0000:ff: Requesting ACPI _OSC control (0x1d) [ 1.731994] pci0000:ff: ACPI _OSC control (0x15) granted [ 2.731814] ACPI: PCI Root Bridge [PCI0] (domain 0000 [bus 00-fe]) [ 2.732226] pci_root PNP0A08:00: host bridge window [io 0x0000-0x0cf7] [ 2.732576] pci_root PNP0A08:00: host bridge window [io 0x1000-0xffff] [ 2.732927] pci_root PNP0A08:00: host bridge window [mem 0x000a0000-0x000bffff] [ 2.733552] pci_root PNP0A08:00: host bridge window [mem 0xfedb0000-0xfedb000f] [ 2.734180] pci_root PNP0A08:00: host bridge window [mem 0xfedc0000-0xfedc000f] [ 2.734806] pci_root PNP0A08:00: host bridge window [mem 0x90000000-0xfbffbfff] [ 2.735439] pci 0000:00:00.0: [8086:6f00] type 0 class 0x000600 [ 2.735473] pci 0000:00:01.0: [8086:6f02] type 1 class 0x000604 [ 2.735499] pci 0000:00:01.0: PME# supported from D0 D3hot D3cold [ 2.735501] pci 0000:00:01.0: PME# disabled [ 2.735514] pci 0000:00:02.0: [8086:6f04] type 1 class 0x000604 [ 2.735539] pci 0000:00:02.0: PME# supported from D0 D3hot D3cold [ 2.735541] pci 0000:00:02.0: PME# disabled [ 2.735554] pci 0000:00:02.2: [8086:6f06] type 1 class 0x000604 [ 2.735580] pci 0000:00:02.2: PME# supported from D0 D3hot D3cold [ 2.735582] pci 0000:00:02.2: PME# disabled [ 2.735597] pci 0000:00:03.0: [8086:6f08] type 1 class 0x000604 [ 2.735622] pci 0000:00:03.0: PME# supported from D0 D3hot D3cold [ 2.735624] pci 0000:00:03.0: PME# disabled [ 2.735637] pci 0000:00:03.2: [8086:6f0a] type 1 class 0x000604 [ 2.735662] pci 0000:00:03.2: PME# supported from D0 D3hot D3cold [ 2.735664] pci 0000:00:03.2: PME# disabled [ 2.735678] pci 0000:00:05.0: [8086:6f28] type 0 class 0x000880 [ 2.735714] pci 0000:00:05.1: [8086:6f29] type 0 class 0x000880 [ 2.735752] pci 0000:00:05.2: [8086:6f2a] type 0 class 0x000880 [ 2.735787] pci 0000:00:05.4: [8086:6f2c] type 0 class 0x000800 [ 2.735792] pci 0000:00:05.4: reg 10: [mem 0xfaa17000-0xfaa17fff] [ 2.735835] pci 0000:00:11.0: [8086:8d7c] type 0 class 0x00ff00 [ 2.735925] pci 0000:00:16.0: [8086:8d3a] type 0 class 0x000780 [ 2.735941] pci 0000:00:16.0: reg 10: [mem 0xfaa16000-0xfaa1600f 64bit] [ 2.735985] pci 0000:00:16.0: PME# supported from D0 D3hot D3cold [ 2.735988] pci 0000:00:16.0: PME# disabled [ 2.736007] pci 0000:00:16.1: [8086:8d3b] type 0 class 0x000780 [ 2.736023] pci 0000:00:16.1: reg 10: [mem 0xfaa15000-0xfaa1500f 64bit] [ 2.736067] pci 0000:00:16.1: PME# supported from D0 D3hot D3cold [ 2.736069] pci 0000:00:16.1: PME# disabled [ 2.736094] pci 0000:00:1a.0: [8086:8d2d] type 0 class 0x000c03 [ 2.736112] pci 0000:00:1a.0: reg 10: [mem 0xfaa13000-0xfaa133ff] [ 2.736175] pci 0000:00:1a.0: PME# supported from D0 D3hot D3cold [ 2.736178] pci 0000:00:1a.0: PME# disabled [ 2.736194] pci 0000:00:1c.0: [8086:8d10] type 1 class 0x000604 [ 2.736238] pci 0000:00:1c.0: PME# supported from D0 D3hot D3cold [ 2.736241] pci 0000:00:1c.0: PME# disabled [ 2.736258] pci 0000:00:1c.2: [8086:8d14] type 1 class 0x000604 [ 2.736303] pci 0000:00:1c.2: PME# supported from D0 D3hot D3cold [ 2.736306] pci 0000:00:1c.2: PME# disabled [ 2.736322] pci 0000:00:1c.4: [8086:8d18] type 1 class 0x000604 [ 2.736367] pci 0000:00:1c.4: PME# supported from D0 D3hot D3cold [ 2.736370] pci 0000:00:1c.4: PME# disabled [ 2.736393] pci 0000:00:1d.0: [8086:8d26] type 0 class 0x000c03 [ 2.736411] pci 0000:00:1d.0: reg 10: [mem 0xfaa12000-0xfaa123ff] [ 2.736474] pci 0000:00:1d.0: PME# supported from D0 D3hot D3cold [ 2.736477] pci 0000:00:1d.0: PME# disabled [ 2.736496] pci 0000:00:1f.0: [8086:8d44] type 0 class 0x000601 [ 2.736589] pci 0000:00:1f.3: [8086:8d22] type 0 class 0x000c05 [ 2.736601] pci 0000:00:1f.3: reg 10: [mem 0xfaa11000-0xfaa110ff 64bit] [ 2.736619] pci 0000:00:1f.3: reg 20: [io 0x0580-0x059f] [ 2.736670] pci 0000:01:00.0: [1ad7:8000] type 0 class 0x001110 [ 2.736682] pci 0000:01:00.0: reg 10: [mem 0xfa900000-0xfa9001ff] [ 2.736770] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 2.737118] pci 0000:00:01.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.737120] pci 0000:00:01.0: bridge window [mem 0xfa900000-0xfa9fffff] [ 2.737123] pci 0000:00:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.737157] pci 0000:02:00.0: [10b5:8632] type 1 class 0x000604 [ 2.737170] pci 0000:02:00.0: reg 10: [mem 0xfa700000-0xfa71ffff] [ 2.737227] pci 0000:02:00.0: PME# supported from D0 D3hot D3cold [ 2.737230] pci 0000:02:00.0: PME# disabled [ 2.737261] pci 0000:00:02.0: PCI bridge to [bus 02-27] [ 2.737608] pci 0000:00:02.0: bridge window [io 0x5000-0xbfff] [ 2.737610] pci 0000:00:02.0: bridge window [mem 0xfa100000-0xfa7fffff] [ 2.737612] pci 0000:00:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.737679] pci 0000:03:01.0: [10b5:8632] type 1 class 0x000604 [ 2.737750] pci 0000:03:01.0: PME# supported from D0 D3hot D3cold [ 2.737753] pci 0000:03:01.0: PME# disabled [ 2.737787] pci 0000:03:02.0: [10b5:8632] type 1 class 0x000604 [ 2.737856] pci 0000:03:02.0: PME# supported from D0 D3hot D3cold [ 2.737860] pci 0000:03:02.0: PME# disabled [ 2.737892] pci 0000:03:03.0: [10b5:8632] type 1 class 0x000604 [ 2.737962] pci 0000:03:03.0: PME# supported from D0 D3hot D3cold [ 2.737965] pci 0000:03:03.0: PME# disabled [ 2.737997] pci 0000:03:04.0: [10b5:8632] type 1 class 0x000604 [ 2.738067] pci 0000:03:04.0: PME# supported from D0 D3hot D3cold [ 2.738071] pci 0000:03:04.0: PME# disabled [ 2.738102] pci 0000:03:05.0: [10b5:8632] type 1 class 0x000604 [ 2.738172] pci 0000:03:05.0: PME# supported from D0 D3hot D3cold [ 2.738176] pci 0000:03:05.0: PME# disabled [ 2.738224] pci 0000:02:00.0: PCI bridge to [bus 03-27] [ 2.738576] pci 0000:02:00.0: bridge window [io 0x5000-0xbfff] [ 2.738579] pci 0000:02:00.0: bridge window [mem 0xfa100000-0xfa6fffff] [ 2.738585] pci 0000:02:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.738638] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 2.738991] pci 0000:03:01.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.738995] pci 0000:03:01.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.739001] pci 0000:03:01.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.739055] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 2.739407] pci 0000:03:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.739410] pci 0000:03:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.739416] pci 0000:03:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.739470] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 2.739822] pci 0000:03:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.739826] pci 0000:03:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.739832] pci 0000:03:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.739901] pci 0000:07:00.0: [111d:8032] type 1 class 0x000604 [ 2.740001] pci 0000:07:00.0: PME# supported from D0 D3hot D3cold [ 2.740006] pci 0000:07:00.0: PME# disabled [ 2.740037] pci 0000:03:04.0: PCI bridge to [bus 07-16] [ 2.740388] pci 0000:03:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.740392] pci 0000:03:04.0: bridge window [mem 0xfa100000-0xfa6fffff] [ 2.740398] pci 0000:03:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.740475] pci 0000:08:02.0: [111d:8032] type 1 class 0x000604 [ 2.740583] pci 0000:08:02.0: PME# supported from D0 D3hot D3cold [ 2.740588] pci 0000:08:02.0: PME# disabled [ 2.740626] pci 0000:08:03.0: [111d:8032] type 1 class 0x000604 [ 2.740735] pci 0000:08:03.0: PME# supported from D0 D3hot D3cold [ 2.740740] pci 0000:08:03.0: PME# disabled [ 2.740779] pci 0000:08:04.0: [111d:8032] type 1 class 0x000604 [ 2.740888] pci 0000:08:04.0: PME# supported from D0 D3hot D3cold [ 2.740893] pci 0000:08:04.0: PME# disabled [ 2.740934] pci 0000:08:06.0: [111d:8032] type 1 class 0x000604 [ 2.741042] pci 0000:08:06.0: PME# supported from D0 D3hot D3cold [ 2.741047] pci 0000:08:06.0: PME# disabled [ 2.741086] pci 0000:08:07.0: [111d:8032] type 1 class 0x000604 [ 2.741194] pci 0000:08:07.0: PME# supported from D0 D3hot D3cold [ 2.741199] pci 0000:08:07.0: PME# disabled [ 2.741237] pci 0000:08:08.0: [111d:8032] type 1 class 0x000604 [ 2.741346] pci 0000:08:08.0: PME# supported from D0 D3hot D3cold [ 2.741351] pci 0000:08:08.0: PME# disabled [ 2.741391] pci 0000:08:0a.0: [111d:8032] type 1 class 0x000604 [ 2.741499] pci 0000:08:0a.0: PME# supported from D0 D3hot D3cold [ 2.741504] pci 0000:08:0a.0: PME# disabled [ 2.741543] pci 0000:08:0b.0: [111d:8032] type 1 class 0x000604 [ 2.741651] pci 0000:08:0b.0: PME# supported from D0 D3hot D3cold [ 2.741656] pci 0000:08:0b.0: PME# disabled [ 2.741712] pci 0000:07:00.0: PCI bridge to [bus 08-16] [ 2.742069] pci 0000:07:00.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.742075] pci 0000:07:00.0: bridge window [mem 0xfa100000-0xfa6fffff] [ 2.742084] pci 0000:07:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.742157] pci 0000:08:02.0: PCI bridge to [bus 09-09] [ 2.742513] pci 0000:08:02.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.742518] pci 0000:08:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.742528] pci 0000:08:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.742632] pci 0000:0a:00.0: [10b5:8111] type 1 class 0x000604 [ 2.742776] pci 0000:0a:00.0: supports D1 [ 2.742777] pci 0000:0a:00.0: PME# supported from D0 D1 D3hot [ 2.742784] pci 0000:0a:00.0: PME# disabled [ 2.742825] pci 0000:08:03.0: PCI bridge to [bus 0a-0b] [ 2.743180] pci 0000:08:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.743185] pci 0000:08:03.0: bridge window [mem 0xfa600000-0xfa6fffff] [ 2.743195] pci 0000:08:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.743338] pci 0000:0b:04.0: [10b5:9056] type 0 class 0x001180 [ 2.743387] pci 0000:0b:04.0: reg 10: [mem 0xfa601000-0xfa6011ff] [ 2.743427] pci 0000:0b:04.0: reg 18: [mem 0xfa600000-0xfa6001ff] [ 2.743662] pci 0000:0a:00.0: PCI bridge to [bus 0b-0b] [ 2.744015] pci 0000:0a:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.744022] pci 0000:0a:00.0: bridge window [mem 0xfa600000-0xfa6fffff] [ 2.744028] pci 0000:0a:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.744147] pci 0000:0c:00.0: [10b5:8111] type 1 class 0x000604 [ 2.744290] pci 0000:0c:00.0: supports D1 [ 2.744291] pci 0000:0c:00.0: PME# supported from D0 D1 D3hot [ 2.744298] pci 0000:0c:00.0: PME# disabled [ 2.744339] pci 0000:08:04.0: PCI bridge to [bus 0c-0d] [ 2.744711] pci 0000:08:04.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.744717] pci 0000:08:04.0: bridge window [mem 0xfa500000-0xfa5fffff] [ 2.744727] pci 0000:08:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.744871] pci 0000:0d:04.0: [10b5:9056] type 0 class 0x001180 [ 2.744920] pci 0000:0d:04.0: reg 10: [mem 0xfa501000-0xfa5011ff] [ 2.744961] pci 0000:0d:04.0: reg 18: [mem 0xfa500000-0xfa5001ff] [ 2.745198] pci 0000:0c:00.0: PCI bridge to [bus 0d-0d] [ 2.745549] pci 0000:0c:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.745556] pci 0000:0c:00.0: bridge window [mem 0xfa500000-0xfa5fffff] [ 2.745562] pci 0000:0c:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.745680] pci 0000:0e:00.0: [10b5:8111] type 1 class 0x000604 [ 2.745823] pci 0000:0e:00.0: supports D1 [ 2.745824] pci 0000:0e:00.0: PME# supported from D0 D1 D3hot [ 2.745831] pci 0000:0e:00.0: PME# disabled [ 2.745872] pci 0000:08:06.0: PCI bridge to [bus 0e-0f] [ 2.746227] pci 0000:08:06.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.746232] pci 0000:08:06.0: bridge window [mem 0xfa400000-0xfa4fffff] [ 2.746241] pci 0000:08:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.746386] pci 0000:0f:04.0: [10b5:9056] type 0 class 0x001180 [ 2.746435] pci 0000:0f:04.0: reg 10: [mem 0xfa401000-0xfa4011ff] [ 2.746476] pci 0000:0f:04.0: reg 18: [mem 0xfa400000-0xfa4001ff] [ 2.746712] pci 0000:0e:00.0: PCI bridge to [bus 0f-0f] [ 2.747064] pci 0000:0e:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.747070] pci 0000:0e:00.0: bridge window [mem 0xfa400000-0xfa4fffff] [ 2.747077] pci 0000:0e:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.747165] pci 0000:08:07.0: PCI bridge to [bus 10-10] [ 2.747519] pci 0000:08:07.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.747525] pci 0000:08:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.747534] pci 0000:08:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.747638] pci 0000:11:00.0: [10b5:8111] type 1 class 0x000604 [ 2.747781] pci 0000:11:00.0: supports D1 [ 2.747782] pci 0000:11:00.0: PME# supported from D0 D1 D3hot [ 2.747788] pci 0000:11:00.0: PME# disabled [ 2.747829] pci 0000:08:08.0: PCI bridge to [bus 11-12] [ 2.748183] pci 0000:08:08.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.748189] pci 0000:08:08.0: bridge window [mem 0xfa300000-0xfa3fffff] [ 2.748198] pci 0000:08:08.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.748340] pci 0000:12:04.0: [10b5:9056] type 0 class 0x000680 [ 2.748389] pci 0000:12:04.0: reg 10: [mem 0xfa301000-0xfa3011ff] [ 2.748429] pci 0000:12:04.0: reg 18: [mem 0xfa300000-0xfa3001ff] [ 2.748664] pci 0000:11:00.0: PCI bridge to [bus 12-12] [ 2.749017] pci 0000:11:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.749023] pci 0000:11:00.0: bridge window [mem 0xfa300000-0xfa3fffff] [ 2.749030] pci 0000:11:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.749147] pci 0000:13:00.0: [10b5:8111] type 1 class 0x000604 [ 2.749289] pci 0000:13:00.0: supports D1 [ 2.749290] pci 0000:13:00.0: PME# supported from D0 D1 D3hot [ 2.749296] pci 0000:13:00.0: PME# disabled [ 2.749337] pci 0000:08:0a.0: PCI bridge to [bus 13-14] [ 2.749692] pci 0000:08:0a.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.749697] pci 0000:08:0a.0: bridge window [mem 0xfa200000-0xfa2fffff] [ 2.749707] pci 0000:08:0a.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.749849] pci 0000:14:04.0: [10b5:9056] type 0 class 0x001180 [ 2.749898] pci 0000:14:04.0: reg 10: [mem 0xfa201000-0xfa2011ff] [ 2.749938] pci 0000:14:04.0: reg 18: [mem 0xfa200000-0xfa2001ff] [ 2.750173] pci 0000:13:00.0: PCI bridge to [bus 14-14] [ 2.750524] pci 0000:13:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.750530] pci 0000:13:00.0: bridge window [mem 0xfa200000-0xfa2fffff] [ 2.750537] pci 0000:13:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.750654] pci 0000:15:00.0: [10b5:8111] type 1 class 0x000604 [ 2.750797] pci 0000:15:00.0: supports D1 [ 2.750798] pci 0000:15:00.0: PME# supported from D0 D1 D3hot [ 2.750804] pci 0000:15:00.0: PME# disabled [ 2.750845] pci 0000:08:0b.0: PCI bridge to [bus 15-16] [ 2.751200] pci 0000:08:0b.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.751205] pci 0000:08:0b.0: bridge window [mem 0xfa100000-0xfa1fffff] [ 2.751215] pci 0000:08:0b.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.751358] pci 0000:16:04.0: [10b5:9056] type 0 class 0x001180 [ 2.751406] pci 0000:16:04.0: reg 10: [mem 0xfa101000-0xfa1011ff] [ 2.751447] pci 0000:16:04.0: reg 18: [mem 0xfa100000-0xfa1001ff] [ 2.751681] pci 0000:15:00.0: PCI bridge to [bus 16-16] [ 2.752032] pci 0000:15:00.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.752039] pci 0000:15:00.0: bridge window [mem 0xfa100000-0xfa1fffff] [ 2.752045] pci 0000:15:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.752213] pci 0000:17:00.0: [111d:8032] type 1 class 0x000604 [ 2.752313] pci 0000:17:00.0: PME# supported from D0 D3hot D3cold [ 2.752318] pci 0000:17:00.0: PME# disabled [ 2.752349] pci 0000:03:05.0: PCI bridge to [bus 17-27] [ 2.752698] pci 0000:03:05.0: bridge window [io 0x5000-0xbfff] [ 2.752702] pci 0000:03:05.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.752708] pci 0000:03:05.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.752785] pci 0000:18:02.0: [111d:8032] type 1 class 0x000604 [ 2.752892] pci 0000:18:02.0: PME# supported from D0 D3hot D3cold [ 2.752898] pci 0000:18:02.0: PME# disabled [ 2.752935] pci 0000:18:03.0: [111d:8032] type 1 class 0x000604 [ 2.753043] pci 0000:18:03.0: PME# supported from D0 D3hot D3cold [ 2.753048] pci 0000:18:03.0: PME# disabled [ 2.753086] pci 0000:18:04.0: [111d:8032] type 1 class 0x000604 [ 2.753195] pci 0000:18:04.0: PME# supported from D0 D3hot D3cold [ 2.753200] pci 0000:18:04.0: PME# disabled [ 2.753240] pci 0000:18:06.0: [111d:8032] type 1 class 0x000604 [ 2.753347] pci 0000:18:06.0: PME# supported from D0 D3hot D3cold [ 2.753352] pci 0000:18:06.0: PME# disabled [ 2.753390] pci 0000:18:07.0: [111d:8032] type 1 class 0x000604 [ 2.753498] pci 0000:18:07.0: PME# supported from D0 D3hot D3cold [ 2.753503] pci 0000:18:07.0: PME# disabled [ 2.753541] pci 0000:18:08.0: [111d:8032] type 1 class 0x000604 [ 2.753650] pci 0000:18:08.0: PME# supported from D0 D3hot D3cold [ 2.753655] pci 0000:18:08.0: PME# disabled [ 2.753696] pci 0000:18:0a.0: [111d:8032] type 1 class 0x000604 [ 2.753804] pci 0000:18:0a.0: PME# supported from D0 D3hot D3cold [ 2.753809] pci 0000:18:0a.0: PME# disabled [ 2.753847] pci 0000:18:0b.0: [111d:8032] type 1 class 0x000604 [ 2.753955] pci 0000:18:0b.0: PME# supported from D0 D3hot D3cold [ 2.753960] pci 0000:18:0b.0: PME# disabled [ 2.754016] pci 0000:17:00.0: PCI bridge to [bus 18-27] [ 2.754386] pci 0000:17:00.0: bridge window [io 0x5000-0xbfff] [ 2.754392] pci 0000:17:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.754401] pci 0000:17:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.754504] pci 0000:19:00.0: [104c:8231] type 1 class 0x000604 [ 2.754641] pci 0000:19:00.0: supports D1 D2 [ 2.754683] pci 0000:18:02.0: PCI bridge to [bus 19-1a] [ 2.755036] pci 0000:18:02.0: bridge window [io 0xb000-0xbfff] [ 2.755042] pci 0000:18:02.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.755051] pci 0000:18:02.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.755172] pci 0000:1a:00.0: [1221:8632] type 0 class 0x000480 [ 2.755201] pci 0000:1a:00.0: reg 10: [io 0xb000-0xb01f] [ 2.755422] pci 0000:19:00.0: PCI bridge to [bus 1a-1a] [ 2.755777] pci 0000:19:00.0: bridge window [io 0xb000-0xbfff] [ 2.755783] pci 0000:19:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.755793] pci 0000:19:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.755880] pci 0000:18:03.0: PCI bridge to [bus 1b-1b] [ 2.756232] pci 0000:18:03.0: bridge window [io 0xfff000-0x0000] (disabled) [ 2.756237] pci 0000:18:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.756247] pci 0000:18:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.756353] pci 0000:1c:00.0: [104c:8240] type 1 class 0x000604 [ 2.756489] pci 0000:1c:00.0: supports D1 D2 [ 2.756535] pci 0000:18:04.0: PCI bridge to [bus 1c-1d] [ 2.756889] pci 0000:18:04.0: bridge window [io 0xa000-0xafff] [ 2.756894] pci 0000:18:04.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.756904] pci 0000:18:04.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.757027] pci 0000:1d:00.0: [1221:8682] type 0 class 0x000480 [ 2.757057] pci 0000:1d:00.0: reg 10: [io 0xa000-0xa01f] [ 2.757280] pci 0000:1c:00.0: PCI bridge to [bus 1d-1d] [ 2.757635] pci 0000:1c:00.0: bridge window [io 0xa000-0xafff] [ 2.757641] pci 0000:1c:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.757652] pci 0000:1c:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.757771] pci 0000:1e:00.0: [104c:8240] type 1 class 0x000604 [ 2.757907] pci 0000:1e:00.0: supports D1 D2 [ 2.757952] pci 0000:18:06.0: PCI bridge to [bus 1e-1f] [ 2.758305] pci 0000:18:06.0: bridge window [io 0x9000-0x9fff] [ 2.758310] pci 0000:18:06.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.758320] pci 0000:18:06.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.758445] pci 0000:1f:00.0: [1221:8682] type 0 class 0x000480 [ 2.758474] pci 0000:1f:00.0: reg 10: [io 0x9000-0x901f] [ 2.758698] pci 0000:1e:00.0: PCI bridge to [bus 1f-1f] [ 2.759052] pci 0000:1e:00.0: bridge window [io 0x9000-0x9fff] [ 2.759058] pci 0000:1e:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.759069] pci 0000:1e:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.759188] pci 0000:20:00.0: [104c:8240] type 1 class 0x000604 [ 2.759324] pci 0000:20:00.0: supports D1 D2 [ 2.759370] pci 0000:18:07.0: PCI bridge to [bus 20-21] [ 2.759724] pci 0000:18:07.0: bridge window [io 0x8000-0x8fff] [ 2.759729] pci 0000:18:07.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.759738] pci 0000:18:07.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.759862] pci 0000:21:00.0: [1221:8682] type 0 class 0x000480 [ 2.759891] pci 0000:21:00.0: reg 10: [io 0x8000-0x801f] [ 2.760114] pci 0000:20:00.0: PCI bridge to [bus 21-21] [ 2.760470] pci 0000:20:00.0: bridge window [io 0x8000-0x8fff] [ 2.760475] pci 0000:20:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.760486] pci 0000:20:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.760605] pci 0000:22:00.0: [104c:8240] type 1 class 0x000604 [ 2.760742] pci 0000:22:00.0: supports D1 D2 [ 2.760787] pci 0000:18:08.0: PCI bridge to [bus 22-23] [ 2.761141] pci 0000:18:08.0: bridge window [io 0x7000-0x7fff] [ 2.761146] pci 0000:18:08.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.761155] pci 0000:18:08.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.761279] pci 0000:23:00.0: [1221:8682] type 0 class 0x000480 [ 2.761309] pci 0000:23:00.0: reg 10: [io 0x7000-0x701f] [ 2.761532] pci 0000:22:00.0: PCI bridge to [bus 23-23] [ 2.761887] pci 0000:22:00.0: bridge window [io 0x7000-0x7fff] [ 2.761893] pci 0000:22:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.761904] pci 0000:22:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.762022] pci 0000:24:00.0: [104c:8231] type 1 class 0x000604 [ 2.762161] pci 0000:24:00.0: supports D1 D2 [ 2.762203] pci 0000:18:0a.0: PCI bridge to [bus 24-25] [ 2.762557] pci 0000:18:0a.0: bridge window [io 0x6000-0x6fff] [ 2.762562] pci 0000:18:0a.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.762572] pci 0000:18:0a.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.762694] pci 0000:25:00.0: [1221:8682] type 0 class 0x000480 [ 2.762723] pci 0000:25:00.0: reg 10: [io 0x6000-0x601f] [ 2.762946] pci 0000:24:00.0: PCI bridge to [bus 25-25] [ 2.763300] pci 0000:24:00.0: bridge window [io 0x6000-0x6fff] [ 2.763306] pci 0000:24:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.763317] pci 0000:24:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.763435] pci 0000:26:00.0: [104c:8231] type 1 class 0x000604 [ 2.763577] pci 0000:26:00.0: supports D1 D2 [ 2.763619] pci 0000:18:0b.0: PCI bridge to [bus 26-27] [ 2.763973] pci 0000:18:0b.0: bridge window [io 0x5000-0x5fff] [ 2.763979] pci 0000:18:0b.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.763988] pci 0000:18:0b.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.764110] pci 0000:27:00.0: [1221:86e2] type 0 class 0x000480 [ 2.764140] pci 0000:27:00.0: reg 10: [io 0x5000-0x501f] [ 2.764378] pci 0000:26:00.0: PCI bridge to [bus 27-27] [ 2.764731] pci 0000:26:00.0: bridge window [io 0x5000-0x5fff] [ 2.764737] pci 0000:26:00.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.764748] pci 0000:26:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.764902] pci 0000:28:00.0: [8086:032d] type 1 class 0x000604 [ 2.764933] pci 0000:28:00.0: PME# supported from D0 D3hot D3cold [ 2.764935] pci 0000:28:00.0: PME# disabled [ 2.764950] pci 0000:00:02.2: PCI bridge to [bus 28-29] [ 2.765293] pci 0000:00:02.2: bridge window [io 0xe000-0xefff] [ 2.765295] pci 0000:00:02.2: bridge window [mem 0xf0000000-0xf80fffff] [ 2.765298] pci 0000:00:02.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.765332] pci 0000:29:0c.0: [114a:5565] type 0 class 0x000280 [ 2.765343] pci 0000:29:0c.0: reg 10: [mem 0xf8001000-0xf80011ff] [ 2.765349] pci 0000:29:0c.0: reg 14: [io 0xe000-0xe0ff] [ 2.765356] pci 0000:29:0c.0: reg 18: [mem 0xf8000000-0xf800003f] [ 2.765362] pci 0000:29:0c.0: reg 1c: [mem 0xf0000000-0xf7ffffff] [ 2.765406] pci 0000:28:00.0: PCI bridge to [bus 29-29] [ 2.765752] pci 0000:28:00.0: bridge window [io 0xe000-0xefff] [ 2.765754] pci 0000:28:00.0: bridge window [mem 0xf0000000-0xf80fffff] [ 2.765757] pci 0000:28:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.765779] pci 0000:00:03.0: PCI bridge to [bus 2a-2a] [ 2.766123] pci 0000:00:03.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.766125] pci 0000:00:03.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.766128] pci 0000:00:03.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.766147] pci 0000:00:03.2: PCI bridge to [bus 2b-2b] [ 2.766491] pci 0000:00:03.2: bridge window [io 0xf000-0x0000] (disabled) [ 2.766493] pci 0000:00:03.2: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.766495] pci 0000:00:03.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.766527] pci 0000:00:1c.0: PCI bridge to [bus 2c-2c] [ 2.766872] pci 0000:00:1c.0: bridge window [io 0xf000-0x0000] (disabled) [ 2.766874] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff] (disabled) [ 2.766878] pci 0000:00:1c.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.766926] pci 0000:2d:00.0: [1a03:1150] type 1 class 0x000604 [ 2.767013] pci 0000:2d:00.0: supports D1 D2 [ 2.767014] pci 0000:2d:00.0: PME# supported from D0 D1 D2 D3hot D3cold [ 2.767018] pci 0000:2d:00.0: PME# disabled [ 2.767045] pci 0000:00:1c.2: PCI bridge to [bus 2d-2e] [ 2.767390] pci 0000:00:1c.2: bridge window [io 0xd000-0xdfff] [ 2.767393] pci 0000:00:1c.2: bridge window [mem 0xf9000000-0xfa0fffff] [ 2.767397] pci 0000:00:1c.2: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.767476] pci 0000:2e:00.0: [1a03:2000] type 0 class 0x000300 [ 2.767502] pci 0000:2e:00.0: reg 10: [mem 0xf9000000-0xf9ffffff] [ 2.767515] pci 0000:2e:00.0: reg 14: [mem 0xfa000000-0xfa01ffff] [ 2.767528] pci 0000:2e:00.0: reg 18: [io 0xd000-0xd07f] [ 2.767605] pci 0000:2e:00.0: supports D1 D2 [ 2.767606] pci 0000:2e:00.0: PME# supported from D0 D1 D2 D3hot D3cold [ 2.767610] pci 0000:2e:00.0: PME# disabled [ 2.767673] pci 0000:2d:00.0: PCI bridge to [bus 2e-2e] [ 2.768022] pci 0000:2d:00.0: bridge window [io 0xd000-0xdfff] [ 2.768026] pci 0000:2d:00.0: bridge window [mem 0xf9000000-0xfa0fffff] [ 2.768033] pci 0000:2d:00.0: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.768090] pci 0000:2f:00.0: [8086:1521] type 0 class 0x000200 [ 2.768103] pci 0000:2f:00.0: reg 10: [mem 0xfa820000-0xfa83ffff] [ 2.768122] pci 0000:2f:00.0: reg 18: [io 0xc020-0xc03f] [ 2.768131] pci 0000:2f:00.0: reg 1c: [mem 0xfa844000-0xfa847fff] [ 2.768190] pci 0000:2f:00.0: PME# supported from D0 D3hot D3cold [ 2.768193] pci 0000:2f:00.0: PME# disabled [ 2.768238] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.768260] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.768288] pci 0000:2f:00.1: [8086:1521] type 0 class 0x000200 [ 2.768301] pci 0000:2f:00.1: reg 10: [mem 0xfa800000-0xfa81ffff] [ 2.768320] pci 0000:2f:00.1: reg 18: [io 0xc000-0xc01f] [ 2.768329] pci 0000:2f:00.1: reg 1c: [mem 0xfa840000-0xfa843fff] [ 2.768388] pci 0000:2f:00.1: PME# supported from D0 D3hot D3cold [ 2.768391] pci 0000:2f:00.1: PME# disabled [ 2.768431] pci 0000:2f:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.768453] pci 0000:2f:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.768480] pci 0000:00:1c.4: PCI bridge to [bus 2f-2f] [ 2.768825] pci 0000:00:1c.4: bridge window [io 0xc000-0xcfff] [ 2.768828] pci 0000:00:1c.4: bridge window [mem 0xfa800000-0xfa8fffff] [ 2.768832] pci 0000:00:1c.4: bridge window [mem 0xfff00000-0x000fffff pref] (disabled) [ 2.768852] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0._PRT] [ 2.768936] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP03._PRT] [ 2.768950] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP03.BR79._PRT] [ 2.768966] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.RP05._PRT] [ 2.768995] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR1A._PRT] [ 2.769023] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR2A._PRT] [ 2.769052] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR2C._PRT] [ 2.769090] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR3A._PRT] [ 2.769122] ACPI: PCI Interrupt Routing Table [\_SB_.PCI0.BR3C._PRT] [ 2.769282] pci0000:00: Requesting ACPI _OSC control (0x1d) [ 2.769946] pci0000:00: ACPI _OSC control (0x15) granted [ 2.777524] ACPI: PCI Interrupt Link [LNKA] (IRQs 3 4 5 6 7 10 *11 12 14 15) [ 2.778622] ACPI: PCI Interrupt Link [LNKB] (IRQs 3 4 5 6 7 *10 11 12 14 15) [ 2.779717] ACPI: PCI Interrupt Link [LNKC] (IRQs 3 4 *5 6 10 11 12 14 15) [ 2.780750] ACPI: PCI Interrupt Link [LNKD] (IRQs *3 4 5 6 10 11 12 14 15) [ 2.781784] ACPI: PCI Interrupt Link [LNKE] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 2.783273] ACPI: PCI Interrupt Link [LNKF] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 2.784778] ACPI: PCI Interrupt Link [LNKG] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 2.786265] ACPI: PCI Interrupt Link [LNKH] (IRQs 3 4 5 6 7 10 11 12 14 15) *0, disabled. [ 2.787844] vgaarb: device added: PCI:0000:2e:00.0,decodes=io+mem,owns=io+mem,locks=none [ 2.788464] vgaarb: loaded [ 2.788802] vgaarb: bridge control possible 0000:2e:00.0 [ 2.789251] SCSI subsystem initialized [ 2.789674] libata version 3.00 loaded. [ 2.789786] usbcore: registered new interface driver usbfs [ 2.790151] usbcore: registered new interface driver hub [ 2.790523] usbcore: registered new device driver usb [ 2.791021] Advanced Linux Sound Architecture Driver Version 1.0.24. [ 2.791366] PCI: Using ACPI for IRQ routing [ 2.796125] PCI: pci_cache_line_size set to 64 bytes [ 2.796353] pci 0000:ff:1e.3: no compatible bridge window for [mem 0x00000020-0x0000003f 64bit] [ 2.797131] reserve RAM buffer: 000000000009ec00 - 000000000009ffff [ 2.797132] reserve RAM buffer: 0000000078f0f000 - 000000007bffffff [ 2.797289] cfg80211: Calling CRDA to update world regulatory domain [ 2.797819] pnp: PnP ACPI init [ 2.798159] ACPI: bus type pnp registered [ 2.798557] pnp 00:00: [bus ff] [ 2.798633] pnp 00:00: Plug and Play ACPI device, IDs PNP0a03 (active) [ 2.798745] pnp 00:01: [bus 00-fe] [ 2.798746] pnp 00:01: [io 0x0cf8-0x0cff] [ 2.798747] pnp 00:01: [io 0x0000-0x0cf7 window] [ 2.798748] pnp 00:01: [io 0x1000-0xffff window] [ 2.798749] pnp 00:01: [mem 0x000a0000-0x000bffff window] [ 2.798750] pnp 00:01: [mem 0xfedb0000-0xfedb000f window] [ 2.798751] pnp 00:01: [mem 0xfedc0000-0xfedc000f window] [ 2.798752] pnp 00:01: [mem 0x90000000-0xfbffbfff window] [ 2.798753] pnp 00:01: [mem 0x00000000 window] [ 2.798814] pnp 00:01: Plug and Play ACPI device, IDs PNP0a08 PNP0a03 (active) [ 2.798818] pnp 00:02: [mem 0xfec00000-0xfecfffff] [ 2.798843] pnp 00:02: Plug and Play ACPI device, IDs PNP0003 (active) [ 2.798851] pnp 00:03: [io 0x0000-0x000f] [ 2.798852] pnp 00:03: [io 0x0081-0x0083] [ 2.798852] pnp 00:03: [io 0x0087] [ 2.798853] pnp 00:03: [io 0x0089-0x008b] [ 2.798854] pnp 00:03: [io 0x008f] [ 2.798855] pnp 00:03: [io 0x00c0-0x00df] [ 2.798856] pnp 00:03: [dma 4] [ 2.798877] pnp 00:03: Plug and Play ACPI device, IDs PNP0200 (active) [ 2.798881] pnp 00:04: [io 0x0070-0x0071] [ 2.798882] pnp 00:04: [io 0x0074-0x0077] [ 2.798886] pnp 00:04: [irq 8] [ 2.798908] pnp 00:04: Plug and Play ACPI device, IDs PNP0b00 (active) [ 2.798914] pnp 00:05: [io 0x00f0] [ 2.798917] pnp 00:05: [irq 13] [ 2.798939] pnp 00:05: Plug and Play ACPI device, IDs PNP0c04 (active) [ 2.798943] pnp 00:06: [io 0x0061] [ 2.798965] pnp 00:06: Plug and Play ACPI device, IDs PNP0800 (active) [ 2.798978] pnp 00:07: [io 0x0500-0x057f] [ 2.798979] pnp 00:07: [io 0x0400-0x047f] [ 2.798980] pnp 00:07: [io 0x0092] [ 2.798981] pnp 00:07: [io 0x0010-0x001f] [ 2.798981] pnp 00:07: [io 0x0072-0x0073] [ 2.798982] pnp 00:07: [io 0x0080] [ 2.798985] pnp 00:07: [io 0x0084-0x0086] [ 2.798986] pnp 00:07: [io 0x0088] [ 2.798987] pnp 00:07: [io 0x008c-0x008e] [ 2.798988] pnp 00:07: [io 0x0090-0x009f] [ 2.798988] pnp 00:07: [io 0x0580-0x059f] [ 2.798989] pnp 00:07: [io 0x0600-0x061f] [ 2.798990] pnp 00:07: [io 0x0880-0x0883] [ 2.798991] pnp 00:07: [io 0x0800-0x081f] [ 2.798992] pnp 00:07: [mem 0xfed1c000-0xfed3ffff] [ 2.798993] pnp 00:07: [mem 0xfed45000-0xfed8bfff] [ 2.798994] pnp 00:07: [mem 0xff000000-0xffffffff] [ 2.798994] pnp 00:07: [mem 0xfee00000-0xfeefffff] [ 2.798995] pnp 00:07: [mem 0xfed12000-0xfed1200f] [ 2.798996] pnp 00:07: [mem 0xfed12010-0xfed1201f] [ 2.798997] pnp 00:07: [mem 0xfed1b000-0xfed1bfff] [ 2.799075] system 00:07: [io 0x0500-0x057f] has been reserved [ 2.799419] system 00:07: [io 0x0400-0x047f] has been reserved [ 2.799765] system 00:07: [io 0x0580-0x059f] has been reserved [ 2.800109] system 00:07: [io 0x0600-0x061f] has been reserved [ 2.800453] system 00:07: [io 0x0880-0x0883] has been reserved [ 2.800798] system 00:07: [io 0x0800-0x081f] has been reserved [ 2.801143] system 00:07: [mem 0xfed1c000-0xfed3ffff] has been reserved [ 2.801488] system 00:07: [mem 0xfed45000-0xfed8bfff] has been reserved [ 2.801836] system 00:07: [mem 0xff000000-0xffffffff] has been reserved [ 2.802181] system 00:07: [mem 0xfee00000-0xfeefffff] has been reserved [ 2.802527] system 00:07: [mem 0xfed12000-0xfed1200f] has been reserved [ 2.802874] system 00:07: [mem 0xfed12010-0xfed1201f] has been reserved [ 2.803220] system 00:07: [mem 0xfed1b000-0xfed1bfff] has been reserved [ 2.803566] system 00:07: Plug and Play ACPI device, IDs PNP0c02 (active) [ 2.803659] pnp 00:08: [io 0x0000-0xffffffffffffffff disabled] [ 2.803660] pnp 00:08: [io 0x0a00-0x0a0f] [ 2.803661] pnp 00:08: [io 0x0a10-0x0a1f] [ 2.803662] pnp 00:08: [io 0x0a20-0x0a2f] [ 2.803662] pnp 00:08: [io 0x0a30-0x0a3f] [ 2.803663] pnp 00:08: [io 0x0a40-0x0a4f] [ 2.803724] system 00:08: [io 0x0a00-0x0a0f] has been reserved [ 2.804068] system 00:08: [io 0x0a10-0x0a1f] has been reserved [ 2.804427] system 00:08: [io 0x0a20-0x0a2f] has been reserved [ 2.804772] system 00:08: [io 0x0a30-0x0a3f] has been reserved [ 2.805115] system 00:08: [io 0x0a40-0x0a4f] has been reserved [ 2.805458] system 00:08: Plug and Play ACPI device, IDs PNP0c02 (active) [ 2.805634] pnp 00:09: [io 0x0ca2] [ 2.805635] pnp 00:09: [io 0x0ca3] [ 2.805659] pnp 00:09: Plug and Play ACPI device, IDs IPI0001 (active) [ 2.805978] pnp: PnP ACPI: found 10 devices [ 2.806319] ACPI: ACPI bus type pnp unregistered [ 2.812765] Switching to clocksource acpi_pm [ 2.813141] PCI: max bus depth: 6 pci_try_num: 7 [ 2.813517] Switched to NOHz mode on CPU #0 [ 2.813598] Switched to NOHz mode on CPU #4 [ 2.813604] Switched to NOHz mode on CPU #1 [ 2.813630] Switched to NOHz mode on CPU #2 [ 2.813662] Switched to NOHz mode on CPU #5 [ 2.813667] Switched to NOHz mode on CPU #3 [ 2.815710] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.815724] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.815738] pci 0000:2f:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.815751] pci 0000:2f:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.815757] pci 0000:ff:12.0: BAR 2: can't assign mem (size 0x40) [ 2.816101] pci 0000:ff:12.0: BAR 4: can't assign mem (size 0x40) [ 2.816446] pci 0000:ff:1e.3: BAR 0: trying firmware assignment [mem 0x00000020-0x0000003f 64bit] [ 2.817071] pci 0000:ff:1e.3: BAR 0: [mem 0x00000020-0x0000003f 64bit] conflicts with reserved [mem 0x00000000-0x0000ffff] [ 2.817700] pci 0000:ff:1e.3: BAR 0: can't assign mem (size 0x20) [ 2.818044] pci 0000:ff:12.0: BAR 1: can't assign mem (size 0x10) [ 2.818388] pci 0000:ff:12.0: BAR 3: can't assign mem (size 0x10) [ 2.818736] pci 0000:ff:12.0: BAR 5: can't assign mem (size 0x10) [ 2.819084] pci 0000:00:1c.4: BAR 15: assigned [mem 0x90000000-0x900fffff 64bit pref] [ 2.819708] pci 0000:00:01.0: PCI bridge to [bus 01-01] [ 2.820050] pci 0000:00:01.0: bridge window [io disabled] [ 2.820393] pci 0000:00:01.0: bridge window [mem 0xfa900000-0xfa9fffff] [ 2.820745] pci 0000:00:01.0: bridge window [mem pref disabled] [ 2.821092] pci 0000:03:05.0: BAR 14: can't assign mem (size 0x200000) [ 2.821437] pci 0000:03:05.0: BAR 15: can't assign mem pref (size 0x200000) [ 2.821787] pci 0000:03:01.0: BAR 14: can't assign mem (size 0x200000) [ 2.822132] pci 0000:03:01.0: BAR 15: can't assign mem pref (size 0x200000) [ 2.822478] pci 0000:03:01.0: BAR 13: can't assign io (size 0x1000) [ 2.822828] pci 0000:03:01.0: PCI bridge to [bus 04-04] [ 2.823170] pci 0000:03:01.0: bridge window [io disabled] [ 2.823522] pci 0000:03:01.0: bridge window [mem disabled] [ 2.823867] pci 0000:03:01.0: bridge window [mem pref disabled] [ 2.824215] pci 0000:03:02.0: PCI bridge to [bus 05-05] [ 2.824578] pci 0000:03:02.0: bridge window [io disabled] [ 2.824923] pci 0000:03:02.0: bridge window [mem disabled] [ 2.825268] pci 0000:03:02.0: bridge window [mem pref disabled] [ 2.825621] pci 0000:03:03.0: PCI bridge to [bus 06-06] [ 2.825963] pci 0000:03:03.0: bridge window [io disabled] [ 2.826308] pci 0000:03:03.0: bridge window [mem disabled] [ 2.826657] pci 0000:03:03.0: bridge window [mem pref disabled] [ 2.827006] pci 0000:08:02.0: PCI bridge to [bus 09-09] [ 2.827347] pci 0000:08:02.0: bridge window [io disabled] [ 2.827701] pci 0000:08:02.0: bridge window [mem disabled] [ 2.828048] pci 0000:08:02.0: bridge window [mem pref disabled] [ 2.828400] pci 0000:0a:00.0: PCI bridge to [bus 0b-0b] [ 2.828746] pci 0000:0a:00.0: bridge window [io disabled] [ 2.829097] pci 0000:0a:00.0: bridge window [mem 0xfa600000-0xfa6fffff] [ 2.829447] pci 0000:0a:00.0: bridge window [mem pref disabled] [ 2.829805] pci 0000:08:03.0: PCI bridge to [bus 0a-0b] [ 2.830146] pci 0000:08:03.0: bridge window [io disabled] [ 2.830500] pci 0000:08:03.0: bridge window [mem 0xfa600000-0xfa6fffff] [ 2.830849] pci 0000:08:03.0: bridge window [mem pref disabled] [ 2.831202] pci 0000:0c:00.0: PCI bridge to [bus 0d-0d] [ 2.831548] pci 0000:0c:00.0: bridge window [io disabled] [ 2.831898] pci 0000:0c:00.0: bridge window [mem 0xfa500000-0xfa5fffff] [ 2.832248] pci 0000:0c:00.0: bridge window [mem pref disabled] [ 2.832607] pci 0000:08:04.0: PCI bridge to [bus 0c-0d] [ 2.832948] pci 0000:08:04.0: bridge window [io disabled] [ 2.833297] pci 0000:08:04.0: bridge window [mem 0xfa500000-0xfa5fffff] [ 2.833652] pci 0000:08:04.0: bridge window [mem pref disabled] [ 2.834004] pci 0000:0e:00.0: PCI bridge to [bus 0f-0f] [ 2.842183] pci 0000:0e:00.0: bridge window [io disabled] [ 2.842538] pci 0000:0e:00.0: bridge window [mem 0xfa400000-0xfa4fffff] [ 2.842888] pci 0000:0e:00.0: bridge window [mem pref disabled] [ 2.843242] pci 0000:08:06.0: PCI bridge to [bus 0e-0f] [ 2.843588] pci 0000:08:06.0: bridge window [io disabled] [ 2.843937] pci 0000:08:06.0: bridge window [mem 0xfa400000-0xfa4fffff] [ 2.844286] pci 0000:08:06.0: bridge window [mem pref disabled] [ 2.844663] pci 0000:08:07.0: PCI bridge to [bus 10-10] [ 2.845003] pci 0000:08:07.0: bridge window [io disabled] [ 2.845352] pci 0000:08:07.0: bridge window [mem disabled] [ 2.845703] pci 0000:08:07.0: bridge window [mem pref disabled] [ 2.846055] pci 0000:11:00.0: PCI bridge to [bus 12-12] [ 2.846396] pci 0000:11:00.0: bridge window [io disabled] [ 2.846751] pci 0000:11:00.0: bridge window [mem 0xfa300000-0xfa3fffff] [ 2.847101] pci 0000:11:00.0: bridge window [mem pref disabled] [ 2.847459] pci 0000:08:08.0: PCI bridge to [bus 11-12] [ 2.847800] pci 0000:08:08.0: bridge window [io disabled] [ 2.848148] pci 0000:08:08.0: bridge window [mem 0xfa300000-0xfa3fffff] [ 2.848501] pci 0000:08:08.0: bridge window [mem pref disabled] [ 2.848852] pci 0000:13:00.0: PCI bridge to [bus 14-14] [ 2.849193] pci 0000:13:00.0: bridge window [io disabled] [ 2.849548] pci 0000:13:00.0: bridge window [mem 0xfa200000-0xfa2fffff] [ 2.849898] pci 0000:13:00.0: bridge window [mem pref disabled] [ 2.850251] pci 0000:08:0a.0: PCI bridge to [bus 13-14] [ 2.850597] pci 0000:08:0a.0: bridge window [io disabled] [ 2.850945] pci 0000:08:0a.0: bridge window [mem 0xfa200000-0xfa2fffff] [ 2.851294] pci 0000:08:0a.0: bridge window [mem pref disabled] [ 2.851651] pci 0000:15:00.0: PCI bridge to [bus 16-16] [ 2.851992] pci 0000:15:00.0: bridge window [io disabled] [ 2.852342] pci 0000:15:00.0: bridge window [mem 0xfa100000-0xfa1fffff] [ 2.852697] pci 0000:15:00.0: bridge window [mem pref disabled] [ 2.853051] pci 0000:08:0b.0: PCI bridge to [bus 15-16] [ 2.853392] pci 0000:08:0b.0: bridge window [io disabled] [ 2.853747] pci 0000:08:0b.0: bridge window [mem 0xfa100000-0xfa1fffff] [ 2.854096] pci 0000:08:0b.0: bridge window [mem pref disabled] [ 2.854468] pci 0000:07:00.0: PCI bridge to [bus 08-16] [ 2.854808] pci 0000:07:00.0: bridge window [io disabled] [ 2.855156] pci 0000:07:00.0: bridge window [mem 0xfa100000-0xfa6fffff] [ 2.855510] pci 0000:07:00.0: bridge window [mem pref disabled] [ 2.855861] pci 0000:03:04.0: PCI bridge to [bus 07-16] [ 2.856201] pci 0000:03:04.0: bridge window [io disabled] [ 2.856551] pci 0000:03:04.0: bridge window [mem 0xfa100000-0xfa6fffff] [ 2.856896] pci 0000:03:04.0: bridge window [mem pref disabled] [ 2.857245] pci 0000:19:00.0: PCI bridge to [bus 1a-1a] [ 2.857593] pci 0000:19:00.0: bridge window [io 0xb000-0xbfff] [ 2.857942] pci 0000:19:00.0: bridge window [mem disabled] [ 2.858288] pci 0000:19:00.0: bridge window [mem pref disabled] [ 2.858645] pci 0000:18:02.0: PCI bridge to [bus 19-1a] [ 2.858987] pci 0000:18:02.0: bridge window [io 0xb000-0xbfff] [ 2.859336] pci 0000:18:02.0: bridge window [mem disabled] [ 2.859687] pci 0000:18:02.0: bridge window [mem pref disabled] [ 2.860039] pci 0000:18:03.0: PCI bridge to [bus 1b-1b] [ 2.860379] pci 0000:18:03.0: bridge window [io disabled] [ 2.860732] pci 0000:18:03.0: bridge window [mem disabled] [ 2.861078] pci 0000:18:03.0: bridge window [mem pref disabled] [ 2.861433] pci 0000:1c:00.0: PCI bridge to [bus 1d-1d] [ 2.861776] pci 0000:1c:00.0: bridge window [io 0xa000-0xafff] [ 2.862125] pci 0000:1c:00.0: bridge window [mem disabled] [ 2.862475] pci 0000:1c:00.0: bridge window [mem pref disabled] [ 2.862828] pci 0000:18:04.0: PCI bridge to [bus 1c-1d] [ 2.863170] pci 0000:18:04.0: bridge window [io 0xa000-0xafff] [ 2.863524] pci 0000:18:04.0: bridge window [mem disabled] [ 2.863870] pci 0000:18:04.0: bridge window [mem pref disabled] [ 2.864222] pci 0000:1e:00.0: PCI bridge to [bus 1f-1f] [ 2.864585] pci 0000:1e:00.0: bridge window [io 0x9000-0x9fff] [ 2.864934] pci 0000:1e:00.0: bridge window [mem disabled] [ 2.865280] pci 0000:1e:00.0: bridge window [mem pref disabled] [ 2.865637] pci 0000:18:06.0: PCI bridge to [bus 1e-1f] [ 2.865979] pci 0000:18:06.0: bridge window [io 0x9000-0x9fff] [ 2.866328] pci 0000:18:06.0: bridge window [mem disabled] [ 2.866679] pci 0000:18:06.0: bridge window [mem pref disabled] [ 2.867030] pci 0000:20:00.0: PCI bridge to [bus 21-21] [ 2.867373] pci 0000:20:00.0: bridge window [io 0x8000-0x8fff] [ 2.867727] pci 0000:20:00.0: bridge window [mem disabled] [ 2.868074] pci 0000:20:00.0: bridge window [mem pref disabled] [ 2.868430] pci 0000:18:07.0: PCI bridge to [bus 20-21] [ 2.868773] pci 0000:18:07.0: bridge window [io 0x8000-0x8fff] [ 2.869122] pci 0000:18:07.0: bridge window [mem disabled] [ 2.869472] pci 0000:18:07.0: bridge window [mem pref disabled] [ 2.869823] pci 0000:22:00.0: PCI bridge to [bus 23-23] [ 2.870166] pci 0000:22:00.0: bridge window [io 0x7000-0x7fff] [ 2.870520] pci 0000:22:00.0: bridge window [mem disabled] [ 2.870866] pci 0000:22:00.0: bridge window [mem pref disabled] [ 2.871218] pci 0000:18:08.0: PCI bridge to [bus 22-23] [ 2.871566] pci 0000:18:08.0: bridge window [io 0x7000-0x7fff] [ 2.871915] pci 0000:18:08.0: bridge window [mem disabled] [ 2.872261] pci 0000:18:08.0: bridge window [mem pref disabled] [ 2.872616] pci 0000:24:00.0: PCI bridge to [bus 25-25] [ 2.872959] pci 0000:24:00.0: bridge window [io 0x6000-0x6fff] [ 2.873308] pci 0000:24:00.0: bridge window [mem disabled] [ 2.873659] pci 0000:24:00.0: bridge window [mem pref disabled] [ 2.874011] pci 0000:18:0a.0: PCI bridge to [bus 24-25] [ 2.874353] pci 0000:18:0a.0: bridge window [io 0x6000-0x6fff] [ 2.874722] pci 0000:18:0a.0: bridge window [mem disabled] [ 2.875067] pci 0000:18:0a.0: bridge window [mem pref disabled] [ 2.875423] pci 0000:26:00.0: PCI bridge to [bus 27-27] [ 2.875766] pci 0000:26:00.0: bridge window [io 0x5000-0x5fff] [ 2.876114] pci 0000:26:00.0: bridge window [mem disabled] [ 2.876464] pci 0000:26:00.0: bridge window [mem pref disabled] [ 2.876816] pci 0000:18:0b.0: PCI bridge to [bus 26-27] [ 2.877158] pci 0000:18:0b.0: bridge window [io 0x5000-0x5fff] [ 2.877512] pci 0000:18:0b.0: bridge window [mem disabled] [ 2.877857] pci 0000:18:0b.0: bridge window [mem pref disabled] [ 2.878208] pci 0000:17:00.0: PCI bridge to [bus 18-27] [ 2.878555] pci 0000:17:00.0: bridge window [io 0x5000-0xbfff] [ 2.878904] pci 0000:17:00.0: bridge window [mem disabled] [ 2.879249] pci 0000:17:00.0: bridge window [mem pref disabled] [ 2.879606] pci 0000:03:05.0: PCI bridge to [bus 17-27] [ 2.879946] pci 0000:03:05.0: bridge window [io 0x5000-0xbfff] [ 2.880292] pci 0000:03:05.0: bridge window [mem disabled] [ 2.880641] pci 0000:03:05.0: bridge window [mem pref disabled] [ 2.880987] pci 0000:02:00.0: PCI bridge to [bus 03-27] [ 2.881329] pci 0000:02:00.0: bridge window [io 0x5000-0xbfff] [ 2.881679] pci 0000:02:00.0: bridge window [mem 0xfa100000-0xfa6fffff] [ 2.882025] pci 0000:02:00.0: bridge window [mem pref disabled] [ 2.882372] pci 0000:00:02.0: PCI bridge to [bus 02-27] [ 2.882717] pci 0000:00:02.0: bridge window [io 0x5000-0xbfff] [ 2.883060] pci 0000:00:02.0: bridge window [mem 0xfa100000-0xfa7fffff] [ 2.883410] pci 0000:00:02.0: bridge window [mem pref disabled] [ 2.883753] pci 0000:28:00.0: PCI bridge to [bus 29-29] [ 2.884094] pci 0000:28:00.0: bridge window [io 0xe000-0xefff] [ 2.884458] pci 0000:28:00.0: bridge window [mem 0xf0000000-0xf80fffff] [ 2.884802] pci 0000:28:00.0: bridge window [mem pref disabled] [ 2.885147] pci 0000:00:02.2: PCI bridge to [bus 28-29] [ 2.885492] pci 0000:00:02.2: bridge window [io 0xe000-0xefff] [ 2.885835] pci 0000:00:02.2: bridge window [mem 0xf0000000-0xf80fffff] [ 2.886179] pci 0000:00:02.2: bridge window [mem pref disabled] [ 2.886527] pci 0000:00:03.0: PCI bridge to [bus 2a-2a] [ 2.886867] pci 0000:00:03.0: bridge window [io disabled] [ 2.887209] pci 0000:00:03.0: bridge window [mem disabled] [ 2.887555] pci 0000:00:03.0: bridge window [mem pref disabled] [ 2.887898] pci 0000:00:03.2: PCI bridge to [bus 2b-2b] [ 2.888237] pci 0000:00:03.2: bridge window [io disabled] [ 2.888584] pci 0000:00:03.2: bridge window [mem disabled] [ 2.888927] pci 0000:00:03.2: bridge window [mem pref disabled] [ 2.889270] pci 0000:00:1c.0: PCI bridge to [bus 2c-2c] [ 2.889615] pci 0000:00:1c.0: bridge window [io disabled] [ 2.889958] pci 0000:00:1c.0: bridge window [mem disabled] [ 2.890300] pci 0000:00:1c.0: bridge window [mem pref disabled] [ 2.890650] pci 0000:2d:00.0: PCI bridge to [bus 2e-2e] [ 2.890992] pci 0000:2d:00.0: bridge window [io 0xd000-0xdfff] [ 2.891337] pci 0000:2d:00.0: bridge window [mem 0xf9000000-0xfa0fffff] [ 2.891689] pci 0000:2d:00.0: bridge window [mem pref disabled] [ 2.892036] pci 0000:00:1c.2: PCI bridge to [bus 2d-2e] [ 2.892381] pci 0000:00:1c.2: bridge window [io 0xd000-0xdfff] [ 2.892726] pci 0000:00:1c.2: bridge window [mem 0xf9000000-0xfa0fffff] [ 2.893070] pci 0000:00:1c.2: bridge window [mem pref disabled] [ 2.893434] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893447] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893461] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893474] pci 0000:2f:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893488] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893501] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893515] pci 0000:2f:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893528] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893542] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893555] pci 0000:2f:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893569] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893582] pci 0000:2f:00.0: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.893583] pci 0000:2f:00.0: BAR 7: assigned [mem 0x90000000-0x9001ffff 64bit pref] [ 2.894212] pci 0000:2f:00.0: BAR 7: set to [mem 0x90000000-0x9001ffff 64bit pref] (PCI address [0x90000000-0x9001ffff]) [ 2.894849] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.894862] pci 0000:2f:00.0: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.894863] pci 0000:2f:00.0: BAR 10: assigned [mem 0x90020000-0x9003ffff 64bit pref] [ 2.895484] pci 0000:2f:00.0: BAR 10: set to [mem 0x90020000-0x9003ffff 64bit pref] (PCI address [0x90020000-0x9003ffff]) [ 2.896115] pci 0000:2f:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.896128] pci 0000:2f:00.1: reg 184: [mem 0x00000000-0x00003fff 64bit pref] [ 2.896129] pci 0000:2f:00.1: BAR 7: assigned [mem 0x90040000-0x9005ffff 64bit pref] [ 2.896750] pci 0000:2f:00.1: BAR 7: set to [mem 0x90040000-0x9005ffff 64bit pref] (PCI address [0x90040000-0x9005ffff]) [ 2.897384] pci 0000:2f:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.897398] pci 0000:2f:00.1: reg 190: [mem 0x00000000-0x00003fff 64bit pref] [ 2.897399] pci 0000:2f:00.1: BAR 10: assigned [mem 0x90060000-0x9007ffff 64bit pref] [ 2.898014] pci 0000:2f:00.1: BAR 10: set to [mem 0x90060000-0x9007ffff 64bit pref] (PCI address [0x90060000-0x9007ffff]) [ 2.898638] pci 0000:00:1c.4: PCI bridge to [bus 2f-2f] [ 2.898977] pci 0000:00:1c.4: bridge window [io 0xc000-0xcfff] [ 2.899319] pci 0000:00:1c.4: bridge window [mem 0xfa800000-0xfa8fffff] [ 2.899667] pci 0000:00:1c.4: bridge window [mem 0x90000000-0x900fffff 64bit pref] [ 2.900291] pci 0000:00:01.0: PCI INT A -> GSI 26 (level, low) -> IRQ 26 [ 2.900639] pci 0000:00:01.0: setting latency timer to 64 [ 2.900644] pci 0000:00:02.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 2.900988] pci 0000:00:02.0: setting latency timer to 64 [ 2.900992] pci 0000:02:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 2.901336] pci 0000:02:00.0: setting latency timer to 64 [ 2.901343] pci 0000:03:01.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 2.901693] pci 0000:03:01.0: setting latency timer to 64 [ 2.901700] pci 0000:03:02.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 2.902044] pci 0000:03:02.0: setting latency timer to 64 [ 2.902053] pci 0000:03:03.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 2.902401] pci 0000:03:03.0: setting latency timer to 64 [ 2.902407] pci 0000:03:04.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 2.902751] pci 0000:03:04.0: setting latency timer to 64 [ 2.902761] pci 0000:07:00.0: setting latency timer to 64 [ 2.902773] pci 0000:08:02.0: setting latency timer to 64 [ 2.902785] pci 0000:08:03.0: setting latency timer to 64 [ 2.902795] pci 0000:0a:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 2.903143] pci 0000:0a:00.0: setting latency timer to 64 [ 2.903155] pci 0000:08:04.0: setting latency timer to 64 [ 2.903165] pci 0000:0c:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 2.903520] pci 0000:0c:00.0: setting latency timer to 64 [ 2.903532] pci 0000:08:06.0: setting latency timer to 64 [ 2.903543] pci 0000:0e:00.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 2.903890] pci 0000:0e:00.0: setting latency timer to 64 [ 2.903902] pci 0000:08:07.0: setting latency timer to 64 [ 2.903914] pci 0000:08:08.0: setting latency timer to 64 [ 2.903924] pci 0000:11:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 2.904270] pci 0000:11:00.0: setting latency timer to 64 [ 2.904282] pci 0000:08:0a.0: setting latency timer to 64 [ 2.904293] pci 0000:13:00.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 2.912426] pci 0000:13:00.0: setting latency timer to 64 [ 2.912438] pci 0000:08:0b.0: setting latency timer to 64 [ 2.912449] pci 0000:15:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 2.912796] pci 0000:15:00.0: setting latency timer to 64 [ 2.912803] pci 0000:03:05.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 2.913148] pci 0000:03:05.0: setting latency timer to 64 [ 2.913158] pci 0000:17:00.0: setting latency timer to 64 [ 2.913170] pci 0000:18:02.0: setting latency timer to 64 [ 2.913183] pci 0000:19:00.0: setting latency timer to 64 [ 2.913194] pci 0000:18:03.0: setting latency timer to 64 [ 2.913206] pci 0000:18:04.0: setting latency timer to 64 [ 2.913219] pci 0000:1c:00.0: setting latency timer to 64 [ 2.913231] pci 0000:18:06.0: setting latency timer to 64 [ 2.913244] pci 0000:1e:00.0: setting latency timer to 64 [ 2.913256] pci 0000:18:07.0: setting latency timer to 64 [ 2.913269] pci 0000:20:00.0: setting latency timer to 64 [ 2.913281] pci 0000:18:08.0: setting latency timer to 64 [ 2.913294] pci 0000:22:00.0: setting latency timer to 64 [ 2.913306] pci 0000:18:0a.0: setting latency timer to 64 [ 2.913319] pci 0000:24:00.0: setting latency timer to 64 [ 2.913331] pci 0000:18:0b.0: setting latency timer to 64 [ 2.913347] pci 0000:26:00.0: setting latency timer to 64 [ 2.913352] pci 0000:00:02.2: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 2.913694] pci 0000:00:02.2: setting latency timer to 64 [ 2.913698] pci 0000:28:00.0: setting latency timer to 64 [ 2.913703] pci 0000:00:03.0: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 2.914045] pci 0000:00:03.0: setting latency timer to 64 [ 2.914048] pci 0000:00:03.2: PCI INT A -> GSI 40 (level, low) -> IRQ 40 [ 2.914393] pci 0000:00:03.2: setting latency timer to 64 [ 2.914399] pci 0000:00:1c.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 2.914742] pci 0000:00:1c.0: setting latency timer to 64 [ 2.914747] pci 0000:00:1c.2: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 2.915090] pci 0000:00:1c.2: setting latency timer to 64 [ 2.915098] pci 0000:2d:00.0: setting latency timer to 64 [ 2.915102] pci 0000:00:1c.4: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 2.915448] pci 0000:00:1c.4: setting latency timer to 64 [ 2.915451] pci_bus 0000:00: resource 4 [io 0x0000-0x0cf7] [ 2.915452] pci_bus 0000:00: resource 5 [io 0x1000-0xffff] [ 2.915453] pci_bus 0000:00: resource 6 [mem 0x000a0000-0x000bffff] [ 2.915454] pci_bus 0000:00: resource 7 [mem 0xfedb0000-0xfedb000f] [ 2.915455] pci_bus 0000:00: resource 8 [mem 0xfedc0000-0xfedc000f] [ 2.915456] pci_bus 0000:00: resource 9 [mem 0x90000000-0xfbffbfff] [ 2.915457] pci_bus 0000:01: resource 1 [mem 0xfa900000-0xfa9fffff] [ 2.915458] pci_bus 0000:02: resource 0 [io 0x5000-0xbfff] [ 2.915459] pci_bus 0000:02: resource 1 [mem 0xfa100000-0xfa7fffff] [ 2.915460] pci_bus 0000:03: resource 0 [io 0x5000-0xbfff] [ 2.915461] pci_bus 0000:03: resource 1 [mem 0xfa100000-0xfa6fffff] [ 2.915463] pci_bus 0000:07: resource 1 [mem 0xfa100000-0xfa6fffff] [ 2.915464] pci_bus 0000:08: resource 1 [mem 0xfa100000-0xfa6fffff] [ 2.915465] pci_bus 0000:0a: resource 1 [mem 0xfa600000-0xfa6fffff] [ 2.915466] pci_bus 0000:0b: resource 1 [mem 0xfa600000-0xfa6fffff] [ 2.915467] pci_bus 0000:0c: resource 1 [mem 0xfa500000-0xfa5fffff] [ 2.915468] pci_bus 0000:0d: resource 1 [mem 0xfa500000-0xfa5fffff] [ 2.915469] pci_bus 0000:0e: resource 1 [mem 0xfa400000-0xfa4fffff] [ 2.915470] pci_bus 0000:0f: resource 1 [mem 0xfa400000-0xfa4fffff] [ 2.915471] pci_bus 0000:11: resource 1 [mem 0xfa300000-0xfa3fffff] [ 2.915472] pci_bus 0000:12: resource 1 [mem 0xfa300000-0xfa3fffff] [ 2.915473] pci_bus 0000:13: resource 1 [mem 0xfa200000-0xfa2fffff] [ 2.915474] pci_bus 0000:14: resource 1 [mem 0xfa200000-0xfa2fffff] [ 2.915475] pci_bus 0000:15: resource 1 [mem 0xfa100000-0xfa1fffff] [ 2.915476] pci_bus 0000:16: resource 1 [mem 0xfa100000-0xfa1fffff] [ 2.915477] pci_bus 0000:17: resource 0 [io 0x5000-0xbfff] [ 2.915478] pci_bus 0000:18: resource 0 [io 0x5000-0xbfff] [ 2.915479] pci_bus 0000:19: resource 0 [io 0xb000-0xbfff] [ 2.915480] pci_bus 0000:1a: resource 0 [io 0xb000-0xbfff] [ 2.915481] pci_bus 0000:1c: resource 0 [io 0xa000-0xafff] [ 2.915482] pci_bus 0000:1d: resource 0 [io 0xa000-0xafff] [ 2.915483] pci_bus 0000:1e: resource 0 [io 0x9000-0x9fff] [ 2.915483] pci_bus 0000:1f: resource 0 [io 0x9000-0x9fff] [ 2.915484] pci_bus 0000:20: resource 0 [io 0x8000-0x8fff] [ 2.915485] pci_bus 0000:21: resource 0 [io 0x8000-0x8fff] [ 2.915486] pci_bus 0000:22: resource 0 [io 0x7000-0x7fff] [ 2.915487] pci_bus 0000:23: resource 0 [io 0x7000-0x7fff] [ 2.915488] pci_bus 0000:24: resource 0 [io 0x6000-0x6fff] [ 2.915489] pci_bus 0000:25: resource 0 [io 0x6000-0x6fff] [ 2.915490] pci_bus 0000:26: resource 0 [io 0x5000-0x5fff] [ 2.915491] pci_bus 0000:27: resource 0 [io 0x5000-0x5fff] [ 2.915492] pci_bus 0000:28: resource 0 [io 0xe000-0xefff] [ 2.915493] pci_bus 0000:28: resource 1 [mem 0xf0000000-0xf80fffff] [ 2.915494] pci_bus 0000:29: resource 0 [io 0xe000-0xefff] [ 2.915495] pci_bus 0000:29: resource 1 [mem 0xf0000000-0xf80fffff] [ 2.915496] pci_bus 0000:2d: resource 0 [io 0xd000-0xdfff] [ 2.915497] pci_bus 0000:2d: resource 1 [mem 0xf9000000-0xfa0fffff] [ 2.915498] pci_bus 0000:2e: resource 0 [io 0xd000-0xdfff] [ 2.915499] pci_bus 0000:2e: resource 1 [mem 0xf9000000-0xfa0fffff] [ 2.915500] pci_bus 0000:2f: resource 0 [io 0xc000-0xcfff] [ 2.915501] pci_bus 0000:2f: resource 1 [mem 0xfa800000-0xfa8fffff] [ 2.915502] pci_bus 0000:2f: resource 2 [mem 0x90000000-0x900fffff 64bit pref] [ 2.915516] NET: Registered protocol family 2 [ 2.916086] IP route cache hash table entries: 524288 (order: 10, 4194304 bytes) [ 2.917409] TCP established hash table entries: 524288 (order: 11, 8388608 bytes) [ 2.919148] TCP bind hash table entries: 65536 (order: 8, 1048576 bytes) [ 2.919633] TCP: Hash tables configured (established 524288 bind 65536) [ 2.919975] TCP reno registered [ 2.920368] UDP hash table entries: 32768 (order: 8, 1048576 bytes) [ 2.920914] UDP-Lite hash table entries: 32768 (order: 8, 1048576 bytes) [ 2.921452] NET: Registered protocol family 1 [ 2.921841] RPC: Registered named UNIX socket transport module. [ 2.922181] RPC: Registered udp transport module. [ 2.922524] RPC: Registered tcp transport module. [ 2.922862] RPC: Registered tcp NFSv4.1 backchannel transport module. [ 2.923270] pci 0000:00:1a.0: EHCI: BIOS handoff [ 2.939350] pci 0000:00:1d.0: EHCI: BIOS handoff [ 2.955428] pci 0000:19:00.0: TI XIO2000a quirk detected; secondary bus fast back-to-back transfers disabled [ 2.956095] pci 0000:24:00.0: TI XIO2000a quirk detected; secondary bus fast back-to-back transfers disabled [ 2.956724] pci 0000:26:00.0: TI XIO2000a quirk detected; secondary bus fast back-to-back transfers disabled [ 2.957360] pci 0000:2e:00.0: Boot video device [ 2.957366] PCI: CLS 64 bytes, default 64 [ 2.957387] PCI-DMA: Using software bounce buffering for IO (SWIOTLB) [ 2.957730] Placing 64MB software IO TLB between ffff880074f0f000 - ffff880078f0f000 [ 2.958343] software IO TLB at phys 0x74f0f000 - 0x78f0f000 [ 3.070360] HugeTLB registered 2 MB page size, pre-allocated 0 pages [ 3.072686] VFS: Disk quotas dquot_6.5.2 [ 3.073064] Dquot-cache hash table entries: 512 (order 0, 4096 bytes) [ 3.073841] Installing knfsd (copyright (C) 1996 okir@monad.swb.de). [ 3.074394] msgmni has been set to 32768 [ 3.074984] Block layer SCSI generic (bsg) driver version 0.4 loaded (major 253) [ 3.075608] io scheduler noop registered [ 3.075943] io scheduler deadline registered [ 3.076320] io scheduler cfq registered (default) [ 3.076841] pcieport 0000:00:01.0: setting latency timer to 64 [ 3.076861] pcieport 0000:00:01.0: irq 64 for MSI/MSI-X [ 3.076904] pcieport 0000:00:02.0: setting latency timer to 64 [ 3.076920] pcieport 0000:00:02.0: irq 65 for MSI/MSI-X [ 3.076963] pcieport 0000:00:02.2: setting latency timer to 64 [ 3.076978] pcieport 0000:00:02.2: irq 66 for MSI/MSI-X [ 3.077019] pcieport 0000:00:03.0: setting latency timer to 64 [ 3.077034] pcieport 0000:00:03.0: irq 67 for MSI/MSI-X [ 3.077076] pcieport 0000:00:03.2: setting latency timer to 64 [ 3.077099] pcieport 0000:00:03.2: irq 68 for MSI/MSI-X [ 3.077141] pcieport 0000:00:1c.0: setting latency timer to 64 [ 3.077168] pcieport 0000:00:1c.0: irq 69 for MSI/MSI-X [ 3.077224] pcieport 0000:00:1c.2: setting latency timer to 64 [ 3.077250] pcieport 0000:00:1c.2: irq 70 for MSI/MSI-X [ 3.077307] pcieport 0000:00:1c.4: setting latency timer to 64 [ 3.077333] pcieport 0000:00:1c.4: irq 71 for MSI/MSI-X [ 3.077395] pcieport 0000:02:00.0: setting latency timer to 64 [ 3.077439] pcieport 0000:02:00.0: irq 72 for MSI/MSI-X [ 3.077522] pcieport 0000:03:01.0: setting latency timer to 64 [ 3.077567] pcieport 0000:03:01.0: irq 73 for MSI/MSI-X [ 3.077665] pcieport 0000:03:02.0: setting latency timer to 64 [ 3.077710] pcieport 0000:03:02.0: irq 74 for MSI/MSI-X [ 3.077788] pcieport 0000:03:03.0: setting latency timer to 64 [ 3.077832] pcieport 0000:03:03.0: irq 75 for MSI/MSI-X [ 3.077911] pcieport 0000:03:04.0: setting latency timer to 64 [ 3.077956] pcieport 0000:03:04.0: irq 76 for MSI/MSI-X [ 3.078035] pcieport 0000:03:05.0: setting latency timer to 64 [ 3.078080] pcieport 0000:03:05.0: irq 77 for MSI/MSI-X [ 3.078193] pcieport 0000:07:00.0: setting latency timer to 64 [ 3.078310] pcieport 0000:08:02.0: setting latency timer to 64 [ 3.078396] pcieport 0000:08:02.0: irq 78 for MSI/MSI-X [ 3.078496] pcieport 0000:08:03.0: setting latency timer to 64 [ 3.078581] pcieport 0000:08:03.0: irq 79 for MSI/MSI-X [ 3.078683] pcieport 0000:08:04.0: setting latency timer to 64 [ 3.078769] pcieport 0000:08:04.0: irq 80 for MSI/MSI-X [ 3.078870] pcieport 0000:08:06.0: setting latency timer to 64 [ 3.078956] pcieport 0000:08:06.0: irq 81 for MSI/MSI-X [ 3.079057] pcieport 0000:08:07.0: setting latency timer to 64 [ 3.079150] pcieport 0000:08:07.0: irq 82 for MSI/MSI-X [ 3.079253] pcieport 0000:08:08.0: setting latency timer to 64 [ 3.079338] pcieport 0000:08:08.0: irq 83 for MSI/MSI-X [ 3.079441] pcieport 0000:08:0a.0: setting latency timer to 64 [ 3.079526] pcieport 0000:08:0a.0: irq 84 for MSI/MSI-X [ 3.079630] pcieport 0000:08:0b.0: setting latency timer to 64 [ 3.079715] pcieport 0000:08:0b.0: irq 85 for MSI/MSI-X [ 3.079838] pcieport 0000:17:00.0: setting latency timer to 64 [ 3.079955] pcieport 0000:18:02.0: setting latency timer to 64 [ 3.080040] pcieport 0000:18:02.0: irq 86 for MSI/MSI-X [ 3.080146] pcieport 0000:18:03.0: setting latency timer to 64 [ 3.080231] pcieport 0000:18:03.0: irq 87 for MSI/MSI-X [ 3.080333] pcieport 0000:18:04.0: setting latency timer to 64 [ 3.080418] pcieport 0000:18:04.0: irq 88 for MSI/MSI-X [ 3.080520] pcieport 0000:18:06.0: setting latency timer to 64 [ 3.080605] pcieport 0000:18:06.0: irq 89 for MSI/MSI-X [ 3.080708] pcieport 0000:18:07.0: setting latency timer to 64 [ 3.080793] pcieport 0000:18:07.0: irq 90 for MSI/MSI-X [ 3.080897] pcieport 0000:18:08.0: setting latency timer to 64 [ 3.080983] pcieport 0000:18:08.0: irq 91 for MSI/MSI-X [ 3.081091] pcieport 0000:18:0a.0: setting latency timer to 64 [ 3.081176] pcieport 0000:18:0a.0: irq 92 for MSI/MSI-X [ 3.081278] pcieport 0000:18:0b.0: setting latency timer to 64 [ 3.081363] pcieport 0000:18:0b.0: irq 93 for MSI/MSI-X [ 3.081706] input: Power Button as /devices/LNXSYSTM:00/device:00/PNP0C0C:00/input/input0 [ 3.082331] ACPI: Power Button [PWRB] [ 3.082703] input: Power Button as /devices/LNXSYSTM:00/LNXPWRBN:00/input/input1 [ 3.083324] ACPI: Power Button [PWRF] [ 3.083763] ACPI: acpi_idle registered with cpuidle [ 3.088292] Serial: 8250/16550 driver, 4 ports, IRQ sharing enabled [ 3.155254] Non-volatile memory driver v1.3 [ 3.155593] Linux agpgart interface v0.103 [ 3.156070] [drm] Initialized drm 1.1.0 20060810 [ 3.156411] [drm:i915_init] *ERROR* drm/i915 can't work without intel_agp module! [ 3.158049] brd: module loaded [ 3.158884] loop: module loaded [ 3.159664] e1000: Intel(R) PRO/1000 Network Driver - version 7.3.21-k8-NAPI [ 3.160014] e1000: Copyright (c) 1999-2006 Intel Corporation. [ 3.160392] e1000e: Intel(R) PRO/1000 Network Driver - 1.3.10-k2 [ 3.160734] e1000e: Copyright(c) 1999 - 2011 Intel Corporation. [ 3.161121] Intel(R) Gigabit Ethernet Network Driver - version 3.0.6-k2 [ 3.161466] Copyright (c) 2007-2011 Intel Corporation. [ 3.161836] igb 0000:2f:00.0: PCI INT A -> GSI 16 (level, low) -> IRQ 16 [ 3.162196] igb 0000:2f:00.0: setting latency timer to 64 [ 3.162460] igb 0000:2f:00.0: irq 94 for MSI/MSI-X [ 3.162463] igb 0000:2f:00.0: irq 95 for MSI/MSI-X [ 3.162465] igb 0000:2f:00.0: irq 96 for MSI/MSI-X [ 3.162468] igb 0000:2f:00.0: irq 97 for MSI/MSI-X [ 3.162470] igb 0000:2f:00.0: irq 98 for MSI/MSI-X [ 3.162473] igb 0000:2f:00.0: irq 99 for MSI/MSI-X [ 3.162475] igb 0000:2f:00.0: irq 100 for MSI/MSI-X [ 3.162494] igb 0000:2f:00.0: 0 vfs allocated [ 3.214375] igb 0000:2f:00.0: Intel(R) Gigabit Ethernet Network Connection [ 3.214721] igb 0000:2f:00.0: eth0: (PCIe:5.0Gb/s:Width x4) ac:1f:6b:b2:c3:50 [ 3.215154] igb 0000:2f:00.0: eth0: PBA No: 050B00-000 [ 3.215496] igb 0000:2f:00.0: Using MSI-X interrupts. 6 rx queue(s), 6 tx queue(s) [ 3.216141] igb 0000:2f:00.1: PCI INT B -> GSI 17 (level, low) -> IRQ 17 [ 3.216492] igb 0000:2f:00.1: setting latency timer to 64 [ 3.216736] igb 0000:2f:00.1: irq 101 for MSI/MSI-X [ 3.216738] igb 0000:2f:00.1: irq 102 for MSI/MSI-X [ 3.216741] igb 0000:2f:00.1: irq 103 for MSI/MSI-X [ 3.216743] igb 0000:2f:00.1: irq 104 for MSI/MSI-X [ 3.216746] igb 0000:2f:00.1: irq 105 for MSI/MSI-X [ 3.216749] igb 0000:2f:00.1: irq 106 for MSI/MSI-X [ 3.216751] igb 0000:2f:00.1: irq 107 for MSI/MSI-X [ 3.216768] igb 0000:2f:00.1: 0 vfs allocated [ 3.271514] igb 0000:2f:00.1: Intel(R) Gigabit Ethernet Network Connection [ 3.271868] igb 0000:2f:00.1: eth1: (PCIe:5.0Gb/s:Width x4) ac:1f:6b:b2:c3:51 [ 3.272293] igb 0000:2f:00.1: eth1: PBA No: 050B00-000 [ 3.272636] igb 0000:2f:00.1: Using MSI-X interrupts. 6 rx queue(s), 6 tx queue(s) [ 3.273289] e100: Intel(R) PRO/100 Network Driver, 3.5.24-k2-NAPI [ 3.273633] e100: Copyright(c) 1999-2006 Intel Corporation [ 3.274063] sky2: driver version 1.28 [ 3.274509] console [netcon0] enabled [ 3.274854] netconsole: network logging started [ 3.275303] ehci_hcd: USB 2.0 'Enhanced' Host Controller (EHCI) Driver [ 3.275648] ehci_hcd: block sizes: qh 112 qtd 96 itd 192 sitd 96 [ 3.275662] ehci_hcd 0000:00:1a.0: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 3.276024] ehci_hcd 0000:00:1a.0: setting latency timer to 64 [ 3.276026] ehci_hcd 0000:00:1a.0: EHCI Host Controller [ 3.276376] drivers/usb/core/inode.c: creating file 'devices' [ 3.276383] drivers/usb/core/inode.c: creating file '001' [ 3.276417] ehci_hcd 0000:00:1a.0: new USB bus registered, assigned bus number 1 [ 3.277045] ehci_hcd 0000:00:1a.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 3.277048] ehci_hcd 0000:00:1a.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 3.277058] ehci_hcd 0000:00:1a.0: support lpm [ 3.277066] ehci_hcd 0000:00:1a.0: debug port 2 [ 3.277408] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 3.281286] ehci_hcd 0000:00:1a.0: cache line size of 64 is not supported [ 3.281287] ehci_hcd 0000:00:1a.0: supports USB remote wakeup [ 3.281298] ehci_hcd 0000:00:1a.0: irq 18, io mem 0xfaa13000 [ 3.281643] ehci_hcd 0000:00:1a.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 3.285520] ehci_hcd 0000:00:1a.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 3.290765] ehci_hcd 0000:00:1a.0: USB 2.0 started, EHCI 1.00 [ 3.291138] usb usb1: default language 0x0409 [ 3.291146] usb usb1: udev 1, busnum 1, minor = 0 [ 3.291149] usb usb1: New USB device found, idVendor=1d6b, idProduct=0002 [ 3.291512] usb usb1: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 3.292132] usb usb1: Product: EHCI Host Controller [ 3.292473] usb usb1: Manufacturer: Linux 3.0.8 ehci_hcd [ 3.292820] usb usb1: SerialNumber: 0000:00:1a.0 [ 3.293207] usb usb1: usb_probe_device [ 3.293208] usb usb1: configuration #1 chosen from 1 choice [ 3.293211] usb usb1: adding 1-0:1.0 (config #1, interface 0) [ 3.293241] hub 1-0:1.0: usb_probe_interface [ 3.293242] hub 1-0:1.0: usb_probe_interface - got id [ 3.293243] hub 1-0:1.0: USB hub found [ 3.293583] hub 1-0:1.0: 2 ports detected [ 3.293929] hub 1-0:1.0: standalone hub [ 3.293929] hub 1-0:1.0: no power switching (usb 1.0) [ 3.293930] hub 1-0:1.0: individual port over-current protection [ 3.293931] hub 1-0:1.0: power on to power good time: 20ms [ 3.293933] hub 1-0:1.0: local power source is good [ 3.293935] hub 1-0:1.0: trying to enable port power on non-switchable hub [ 3.293944] drivers/usb/core/inode.c: creating file '001' [ 3.293987] ehci_hcd 0000:00:1d.0: PCI INT C -> GSI 18 (level, low) -> IRQ 18 [ 3.294340] ehci_hcd 0000:00:1d.0: setting latency timer to 64 [ 3.294342] ehci_hcd 0000:00:1d.0: EHCI Host Controller [ 3.294688] drivers/usb/core/inode.c: creating file '002' [ 3.294720] ehci_hcd 0000:00:1d.0: new USB bus registered, assigned bus number 2 [ 3.295344] ehci_hcd 0000:00:1d.0: reset hcs_params 0x200002 dbg=2 cc=0 pcc=0 ordered !ppc ports=2 [ 3.295347] ehci_hcd 0000:00:1d.0: reset hcc_params 36881 caching frame 1024 64 bit addr [ 3.295354] ehci_hcd 0000:00:1d.0: support lpm [ 3.295362] ehci_hcd 0000:00:1d.0: debug port 2 [ 3.295703] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 3.299568] ehci_hcd 0000:00:1d.0: cache line size of 64 is not supported [ 3.299569] ehci_hcd 0000:00:1d.0: supports USB remote wakeup [ 3.299572] ehci_hcd 0000:00:1d.0: irq 18, io mem 0xfaa12000 [ 3.299921] ehci_hcd 0000:00:1d.0: reset command 0080002 (park)=0 ithresh=8 period=1024 Reset HALT [ 3.303802] ehci_hcd 0000:00:1d.0: init command 0010001 (park)=0 ithresh=1 period=1024 RUN [ 3.309735] ehci_hcd 0000:00:1d.0: USB 2.0 started, EHCI 1.00 [ 3.310099] usb usb2: default language 0x0409 [ 3.310107] usb usb2: udev 1, busnum 2, minor = 128 [ 3.310110] usb usb2: New USB device found, idVendor=1d6b, idProduct=0002 [ 3.310471] usb usb2: New USB device strings: Mfr=3, Product=2, SerialNumber=1 [ 3.311092] usb usb2: Product: EHCI Host Controller [ 3.311432] usb usb2: Manufacturer: Linux 3.0.8 ehci_hcd [ 3.311778] usb usb2: SerialNumber: 0000:00:1d.0 [ 3.312157] usb usb2: usb_probe_device [ 3.312158] usb usb2: configuration #1 chosen from 1 choice [ 3.312160] usb usb2: adding 2-0:1.0 (config #1, interface 0) [ 3.312188] hub 2-0:1.0: usb_probe_interface [ 3.312188] hub 2-0:1.0: usb_probe_interface - got id [ 3.312189] hub 2-0:1.0: USB hub found [ 3.312528] hub 2-0:1.0: 2 ports detected [ 3.312874] hub 2-0:1.0: standalone hub [ 3.312874] hub 2-0:1.0: no power switching (usb 1.0) [ 3.312875] hub 2-0:1.0: individual port over-current protection [ 3.312876] hub 2-0:1.0: power on to power good time: 20ms [ 3.312878] hub 2-0:1.0: local power source is good [ 3.312879] hub 2-0:1.0: trying to enable port power on non-switchable hub [ 3.312887] drivers/usb/core/inode.c: creating file '001' [ 3.312947] ohci_hcd: USB 1.1 'Open' Host Controller (OHCI) Driver [ 3.313291] ohci_hcd: block sizes: ed 80 td 96 [ 3.313325] uhci_hcd: USB Universal Host Controller Interface driver [ 3.313740] usbcore: registered new interface driver usblp [ 3.314082] Initializing USB Mass Storage driver... [ 3.314453] usbcore: registered new interface driver usb-storage [ 3.314803] USB Mass Storage support registered. [ 3.315170] usbcore: registered new interface driver libusual [ 3.315610] i8042: PNP: No PS/2 controller found. Probing ports directly. [ 3.316825] i8042: No controller found [ 3.317192] mousedev: PS/2 mouse device common for all mice [ 3.317668] rtc_cmos 00:04: RTC can wake from S4 [ 3.318096] rtc_cmos 00:04: rtc core: registered rtc_cmos as rtc0 [ 3.318462] rtc0: alarms up to one month, y3k, 114 bytes nvram [ 3.318997] device-mapper: ioctl: 4.20.0-ioctl (2011-02-02) initialised: dm-devel@redhat.com [ 3.319655] cpuidle: using governor ladder [ 3.320001] cpuidle: using governor menu [ 3.320340] EFI Variables Facility v0.08 2004-May-17 [ 3.321409] usbcore: registered new interface driver usbhid [ 3.321756] usbhid: USB HID core driver [ 3.322308] ALSA device list: [ 3.322644] No soundcards found. [ 3.323031] Netfilter messages via NETLINK v0.30. [ 3.323382] nf_conntrack version 0.5.0 (16384 buckets, 65536 max) [ 3.323813] ctnetlink v0.93: registering with nfnetlink. [ 3.324374] TCP cubic registered [ 3.324721] Initializing XFRM netlink socket [ 3.325200] NET: Registered protocol family 10 [ 3.325957] IPv6 over IPv4 tunneling driver [ 3.326557] NET: Registered protocol family 17 [ 3.326913] Registering the dns_resolver key type [ 3.327342] PM: Hibernation image not present or could not be loaded. [ 3.328886] Magic number: 6:610:3 [ 3.393299] ADDRCONF(NETDEV_UP): eth0: link is not ready [ 3.393651] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 3.393653] hub 1-0:1.0: port 1: status 0501 change 0001 [ 3.454139] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001803 0 ACK POWER sig=j CSC CONNECT [ 3.454141] hub 2-0:1.0: port 1: status 0501 change 0001 [ 3.455693] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 3.493462] hub 1-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 3.493472] hub 1-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 3.544643] ehci_hcd 0000:00:1a.0: port 1 high speed [ 3.544649] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 3.595292] usb 1-1: new high speed USB device number 2 using ehci_hcd [ 3.646483] ehci_hcd 0000:00:1a.0: port 1 high speed [ 3.646490] ehci_hcd 0000:00:1a.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 3.709269] ehci_hcd 0000:00:1a.0: set dev address 2 for port 1 [ 3.709274] ehci_hcd 0000:00:1a.0: LPM: no device attached [ 3.709520] usb 1-1: udev 2, busnum 1, minor = 1 [ 3.709523] usb 1-1: New USB device found, idVendor=8087, idProduct=800a [ 3.709894] usb 1-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 3.710303] usb 1-1: usb_probe_device [ 3.710304] usb 1-1: configuration #1 chosen from 1 choice [ 3.710412] usb 1-1: adding 1-1:1.0 (config #1, interface 0) [ 3.710446] hub 1-1:1.0: usb_probe_interface [ 3.710447] hub 1-1:1.0: usb_probe_interface - got id [ 3.710448] hub 1-1:1.0: USB hub found [ 3.710886] hub 1-1:1.0: 6 ports detected [ 3.711239] hub 1-1:1.0: standalone hub [ 3.711240] hub 1-1:1.0: individual port power switching [ 3.711241] hub 1-1:1.0: individual port over-current protection [ 3.711242] hub 1-1:1.0: Single TT [ 3.711243] hub 1-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 3.711244] hub 1-1:1.0: power on to power good time: 0ms [ 3.711510] hub 1-1:1.0: local power source is good [ 3.711511] hub 1-1:1.0: enabling power on all ports [ 3.712264] drivers/usb/core/inode.c: creating file '002' [ 3.712281] hub 2-0:1.0: state 7 ports 2 chg 0002 evt 0000 [ 3.712284] hub 2-0:1.0: port 1, status 0501, change 0000, 480 Mb/s [ 3.763299] ehci_hcd 0000:00:1d.0: port 1 high speed [ 3.763305] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 3.812745] hub 1-1:1.0: port 6: status 0101 change 0001 [ 3.813947] usb 2-1: new high speed USB device number 2 using ehci_hcd [ 3.865141] ehci_hcd 0000:00:1d.0: port 1 high speed [ 3.865146] ehci_hcd 0000:00:1d.0: GetStatus port:1 status 001005 0 ACK POWER sig=se0 PE CONNECT [ 3.911806] usb 1-1: link qh256-0001/ffff881078936580 start 1 [1/0 us] [ 3.927926] ehci_hcd 0000:00:1d.0: set dev address 2 for port 1 [ 3.927931] ehci_hcd 0000:00:1d.0: LPM: no device attached [ 3.928176] usb 2-1: udev 2, busnum 2, minor = 129 [ 3.928179] usb 2-1: New USB device found, idVendor=8087, idProduct=8002 [ 3.928548] usb 2-1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 3.928955] usb 2-1: usb_probe_device [ 3.928957] usb 2-1: configuration #1 chosen from 1 choice [ 3.929049] usb 2-1: adding 2-1:1.0 (config #1, interface 0) [ 3.929082] hub 2-1:1.0: usb_probe_interface [ 3.929082] hub 2-1:1.0: usb_probe_interface - got id [ 3.929083] hub 2-1:1.0: USB hub found [ 3.929545] hub 2-1:1.0: 8 ports detected [ 3.929897] hub 2-1:1.0: standalone hub [ 3.929897] hub 2-1:1.0: individual port power switching [ 3.929898] hub 2-1:1.0: individual port over-current protection [ 3.929899] hub 2-1:1.0: Single TT [ 3.929900] hub 2-1:1.0: TT requires at most 8 FS bit times (666 ns) [ 3.929901] hub 2-1:1.0: power on to power good time: 0ms [ 3.930172] hub 2-1:1.0: local power source is good [ 3.930175] hub 2-1:1.0: enabling power on all ports [ 3.931175] drivers/usb/core/inode.c: creating file '002' [ 3.931181] hub 1-1:1.0: state 7 ports 6 chg 0040 evt 0000 [ 3.931295] hub 1-1:1.0: port 6, status 0101, change 0000, 12 Mb/s [ 3.941906] hub 1-1:1.0: port 6 not reset yet, waiting 10ms [ 3.957720] Refined TSC clocksource calibration: 3599.998 MHz. [ 3.958080] Switching to clocksource tsc [ 4.003686] usb 1-1.6: new high speed USB device number 3 using ehci_hcd [ 4.014666] hub 1-1:1.0: port 6 not reset yet, waiting 10ms [ 4.030639] hub 2-1:1.0: port 1: status 0101 change 0001 [ 4.088925] usb 1-1.6: udev 3, busnum 1, minor = 2 [ 4.088928] usb 1-1.6: New USB device found, idVendor=0557, idProduct=7000 [ 4.089287] usb 1-1.6: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 4.089970] usb 1-1.6: usb_probe_device [ 4.089971] usb 1-1.6: configuration #1 chosen from 1 choice [ 4.090047] usb 1-1.6: adding 1-1.6:1.0 (config #1, interface 0) [ 4.090073] hub 1-1.6:1.0: usb_probe_interface [ 4.090074] hub 1-1.6:1.0: usb_probe_interface - got id [ 4.090075] hub 1-1.6:1.0: USB hub found [ 4.090544] hub 1-1.6:1.0: 4 ports detected [ 4.090888] hub 1-1.6:1.0: standalone hub [ 4.090889] hub 1-1.6:1.0: ganged power switching [ 4.090890] hub 1-1.6:1.0: global over-current protection [ 4.090890] hub 1-1.6:1.0: Single TT [ 4.090891] hub 1-1.6:1.0: TT requires at most 8 FS bit times (666 ns) [ 4.090892] hub 1-1.6:1.0: power on to power good time: 0ms [ 4.091167] hub 1-1.6:1.0: local power source is lost (inactive) [ 4.091168] hub 1-1.6:1.0: no over-current condition exists [ 4.091169] hub 1-1.6:1.0: enabling power on all ports [ 4.091689] drivers/usb/core/inode.c: creating file '003' [ 4.091695] hub 1-1:1.0: state 7 ports 6 chg 0000 evt 0040 [ 4.131447] usb 2-1: link qh256-0001/ffff881078936680 start 1 [1/0 us] [ 4.131462] hub 2-1:1.0: state 7 ports 8 chg 0002 evt 0000 [ 4.131612] hub 2-1:1.0: port 1, status 0101, change 0000, 12 Mb/s [ 4.142466] hub 2-1:1.0: port 1 not reset yet, waiting 10ms [ 4.191511] hub 1-1.6:1.0: port 1: status 0101 change 0001 [ 4.204373] usb 2-1.1: new low speed USB device number 3 using ehci_hcd [ 4.216350] hub 2-1:1.0: port 1 not reset yet, waiting 10ms [ 4.291193] usb 1-1.6: link qh256-0001/ffff881078936780 start 2 [1/0 us] [ 4.293607] usb 2-1.1: skipped 1 descriptor after interface [ 4.293610] usb 2-1.1: skipped 1 descriptor after interface [ 4.294103] usb 2-1.1: default language 0x0409 [ 4.298223] usb 2-1.1: udev 3, busnum 2, minor = 130 [ 4.298226] usb 2-1.1: New USB device found, idVendor=0557, idProduct=2221 [ 4.298596] usb 2-1.1: New USB device strings: Mfr=1, Product=2, SerialNumber=3 [ 4.299223] usb 2-1.1: Product: UC-10KM V1.3.124 [ 4.299569] usb 2-1.1: Manufacturer: ATEN [ 4.299914] usb 2-1.1: SerialNumber: USB Composite device [ 4.300302] usb 2-1.1: usb_probe_device [ 4.300303] usb 2-1.1: configuration #1 chosen from 1 choice [ 4.301842] usb 2-1.1: adding 2-1.1:1.0 (config #1, interface 0) [ 4.303272] usbhid 2-1.1:1.0: usb_probe_interface [ 4.303275] usbhid 2-1.1:1.0: usb_probe_interface - got id [ 4.307748] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.1/2-1.1:1.0/input/input2 [ 4.308398] usb 2-1.1: link qh8-0601/ffff881078936880 start 2 [1/2 us] [ 4.308469] generic-usb 0003:0557:2221.0001: input,hidraw0: USB HID v1.10 Keyboard [ATEN UC-10KM V1.3.124] on usb-0000:00:1d.0-1.1/input0 [ 4.309111] usb 2-1.1: adding 2-1.1:1.1 (config #1, interface 1) [ 4.310260] usbhid 2-1.1:1.1: usb_probe_interface [ 4.310262] usbhid 2-1.1:1.1: usb_probe_interface - got id [ 4.314378] input: ATEN UC-10KM V1.3.124 as /devices/pci0000:00/0000:00:1d.0/usb2/2-1/2-1.1/2-1.1:1.1/input/input3 [ 4.315114] generic-usb 0003:0557:2221.0002: input,hidraw1: USB HID v1.10 Mouse [ATEN UC-10KM V1.3.124] on usb-0000:00:1d.0-1.1/input1 [ 4.323750] drivers/usb/core/inode.c: creating file '003' [ 4.323757] hub 1-1.6:1.0: state 7 ports 4 chg 0002 evt 0002 [ 4.323929] hub 1-1.6:1.0: port 1, status 0101, change 0000, 12 Mb/s [ 4.405184] usb 1-1.6.1: new low speed USB device number 4 using ehci_hcd [ 4.506647] usb 1-1.6.1: skipped 1 descriptor after interface [ 4.506651] usb 1-1.6.1: skipped 1 descriptor after interface [ 4.506654] usb 1-1.6.1: udev 4, busnum 1, minor = 3 [ 4.506657] usb 1-1.6.1: New USB device found, idVendor=0557, idProduct=2419 [ 4.507019] usb 1-1.6.1: New USB device strings: Mfr=0, Product=0, SerialNumber=0 [ 4.507701] usb 1-1.6.1: usb_probe_device [ 4.507702] usb 1-1.6.1: configuration #1 chosen from 1 choice [ 4.507771] usb 1-1.6.1: adding 1-1.6.1:1.0 (config #1, interface 0) [ 4.507801] usbhid 1-1.6.1:1.0: usb_probe_interface [ 4.507802] usbhid 1-1.6.1:1.0: usb_probe_interface - got id [ 4.508126] input: HID 0557:2419 as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.6/1-1.6.1/1-1.6.1:1.0/input/input4 [ 4.508769] usb 1-1.6.1: link qh8-0601/ffff881078936a80 start 3 [1/2 us] [ 4.508835] generic-usb 0003:0557:2419.0003: input,hidraw2: USB HID v1.00 Keyboard [HID 0557:2419] on usb-0000:00:1a.0-1.6.1/input0 [ 4.509482] usb 1-1.6.1: adding 1-1.6.1:1.1 (config #1, interface 1) [ 4.509514] usbhid 1-1.6.1:1.1: usb_probe_interface [ 4.509515] usbhid 1-1.6.1:1.1: usb_probe_interface - got id [ 4.510359] input: HID 0557:2419 as /devices/pci0000:00/0000:00:1a.0/usb1/1-1/1-1.6/1-1.6.1/1-1.6.1:1.1/input/input5 [ 4.511078] generic-usb 0003:0557:2419.0004: input,hidraw3: USB HID v1.00 Mouse [HID 0557:2419] on usb-0000:00:1a.0-1.6.1/input1 [ 4.511717] drivers/usb/core/inode.c: creating file '004' [ 6.995370] igb: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 6.997124] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 7.006942] Sending DHCP requests . [ 7.086219] igb: eth0 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 7.088240] ADDRCONF(NETDEV_CHANGE): eth0: link becomes ready [ 9.945338] ., OK [ 9.956324] IP-Config: Got DHCP answer from 10.68.10.100, my address is 10.68.10.201 [ 10.002491] IP-Config: Complete: [ 10.002835] device=eth0, addr=10.68.10.201, mask=255.255.255.0, gw=10.68.10.1, [ 10.003375] host=k1ex1, domain=kagra.icrr.u-tokyo.ac.jp, nis-domain=(none), [ 10.004062] bootserver=10.68.10.100, rootserver=10.68.10.100, rootpath= [ 10.004962] md: Waiting for all devices to be available before autodetect [ 10.005314] md: If you don't use raid, use raid=noautodetect [ 10.005789] md: Autodetecting RAID arrays. [ 10.006133] md: Scanned 0 and added 0 devices. [ 10.006487] md: autorun ... [ 10.006829] md: ... autorun DONE. [ 10.011366] VFS: Mounted root (nfs filesystem) readonly on device 0:14. [ 10.012437] Freeing unused kernel memory: 628k freed [ 10.012886] Write protecting the kernel read-only data: 10240k [ 10.014462] Freeing unused kernel memory: 724k freed [ 10.017144] Freeing unused kernel memory: 1368k freed [ 10.107095] hostname used greatest stack depth: 4120 bytes left [ 10.135251] awk used greatest stack depth: 4088 bytes left [ 10.159724] mount.nfs used greatest stack depth: 3848 bytes left [ 10.896505] runscript.sh used greatest stack depth: 3776 bytes left [ 11.244027] igb 0000:2f:00.1: changing MTU from 1500 to 9000 [ 11.340949] ADDRCONF(NETDEV_UP): eth1: link is not ready [ 11.371338] Open-MX 1.5.3 initializing... [ 11.371689] Open-MX: attaching interfaces listed in 'eth1'... [ 11.372032] Open-MX: Attaching Ethernet interface 'eth1' as #0, MTU=9000 [ 11.372379] Open-MX: Interface 'eth1' is PCI device '0000:2f:00.1' managed by driver 'igb' [ 11.372998] Open-MX: attached 1 interfaces [ 11.373397] Open-MX initialized [ 14.789168] igb: eth1 NIC Link is Up 1000 Mbps Full Duplex, Flow Control: RX [ 14.792988] ADDRCONF(NETDEV_CHANGE): eth1: link becomes ready [ 17.119108] eth0: no IPv6 routers present [ 24.994781] eth1: no IPv6 routers present [ 32.646771] Spectracom GPS card on bus 1; device 0 [ 32.647145] pci 0000:01:00.0: PCI INT A -> GSI 26 (level, low) -> IRQ 26 [ 32.647496] TSYNC PIC BASE 0 address = fa900000 [ 32.647869] Remapped 0xffffc90023994000 [ 37.667151] TSYNC receiving YEAR info [ 37.667488] date = 321 days 1: 5:1326762356 [ 37.667825] bcd time = 1326762356 sec 642 milliseconds 891 microseconds 642888590 nanosec [ 37.668437] Board sync = 1 [ 37.678760] TSYNC receiving YEAR info [ 37.679097] date = 21 days 1: 5:1326762356 [ 37.679434] bcd time = 1326762356 sec 654 milliseconds 518 microseconds 654515450 nanosec [ 37.680047] Board sync = 1 [ 47.971700] k1iopex1: startup time is 1326762366 [ 47.971702] k1iopex1: cpu clock 3599825 [ 47.971703] k1iopex1: EPICSM at 0x23996000 [ 47.971900] k1iopex1: IPC at 0x27a26000 [ 47.971901] k1iopex1: IOMEM at 0x27a2a000 size 0x33410 [ 47.971902] k1iopex1: DAQSM at 0x17903000 [ 47.971902] k1iopex1: configured to use 13 cards [ 47.971903] k1iopex1: Initializing PCI Modules [ 47.971917] k1iopex1: ADC card on bus b; device 4 prim b [ 47.971918] k1iopex1: adc card on bus b; device 4 prim b [ 47.971948] pci 0000:0b:04.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 47.975727] k1iopex1: pci0 = 0xfa601000 [ 47.975751] k1iopex1: pci2 = 0xfa600000 [ 47.975755] k1iopex1: ADC I/O address=0xfa600000 0xffffc900170b6000 [ 47.975759] k1iopex1: BCR = 0x84060 [ 47.975773] k1iopex1: RAG = 0x117d8 [ 47.975777] k1iopex1: BCR = 0x84260 [ 48.403519] k1iopex1: SSC = 0x16 [ 48.403523] k1iopex1: IDBC = 0x1f [ 48.403529] k1iopex1: DAC card on bus d; device 4 prim d [ 48.403530] k1iopex1: dac card on bus d; device 4 [ 48.403541] pci 0000:0d:04.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 48.407248] k1iopex1: pci0 = 0xfa501000 [ 48.407255] k1iopex1: dac pci2 = 0xfa500000 [ 48.407258] k1iopex1: DAC I/O address=0xfa500000 0xffffc900170ba000 [ 48.407262] k1iopex1: DAC BCR = 0x810 [ 48.407387] k1iopex1: DAC BCR after init = 0x30080 [ 48.407390] k1iopex1: DAC CSR = 0xffff [ 48.407397] k1iopex1: DAC BOR = 0x3415 [ 48.407402] k1iopex1: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [ 48.407428] k1iopex1: ADC card on bus f; device 4 prim f [ 48.407429] k1iopex1: adc card on bus f; device 4 prim f [ 48.407439] pci 0000:0f:04.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 48.411160] k1iopex1: pci0 = 0xfa401000 [ 48.411166] k1iopex1: pci2 = 0xfa400000 [ 48.411169] k1iopex1: ADC I/O address=0xfa400000 0xffffc900170be000 [ 48.411172] k1iopex1: BCR = 0x84060 [ 48.411187] k1iopex1: RAG = 0x117d8 [ 48.411190] k1iopex1: BCR = 0x84260 [ 48.838943] k1iopex1: SSC = 0x16 [ 48.838946] k1iopex1: IDBC = 0x1f [ 48.838961] k1iopex1: DAC card on bus 12; device 4 prim 12 [ 48.838961] k1iopex1: dac card on bus 12; device 4 [ 48.838973] pci 0000:12:04.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 48.842688] k1iopex1: pci0 = 0xfa301000 [ 48.842699] k1iopex1: dac pci2 = 0xfa300000 [ 48.842702] k1iopex1: DAC I/O address=0xfa300000 0xffffc900170c2000 [ 48.842706] k1iopex1: DAC BCR = 0x810 [ 48.842832] k1iopex1: DAC BCR after init = 0x30080 [ 48.842836] k1iopex1: DAC CSR = 0xffff [ 48.842842] k1iopex1: DAC BOR = 0x3415 [ 48.842847] k1iopex1: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [ 48.842872] k1iopex1: DAC card on bus 14; device 4 prim 14 [ 48.842873] k1iopex1: dac card on bus 14; device 4 [ 48.842883] pci 0000:14:04.0: PCI INT A -> GSI 37 (level, low) -> IRQ 37 [ 48.846616] k1iopex1: pci0 = 0xfa201000 [ 48.846628] k1iopex1: dac pci2 = 0xfa200000 [ 48.846631] k1iopex1: DAC I/O address=0xfa200000 0xffffc900170c6000 [ 48.846635] k1iopex1: DAC BCR = 0x810 [ 48.846758] k1iopex1: DAC BCR after init = 0x30080 [ 48.846762] k1iopex1: DAC CSR = 0xffff [ 48.846769] k1iopex1: DAC BOR = 0x3415 [ 48.846773] k1iopex1: set_8111_prefetch: subsys=0x8111; vendor=0x10b5 [ 48.846798] k1iopex1: ADC card on bus 16; device 4 prim 16 [ 48.846799] k1iopex1: adc card on bus 16; device 4 prim 16 [ 48.846809] pci 0000:16:04.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 48.850535] k1iopex1: pci0 = 0xfa101000 [ 48.850544] k1iopex1: pci2 = 0xfa100000 [ 48.850547] k1iopex1: ADC I/O address=0xfa100000 0xffffc900170ca000 [ 48.850550] k1iopex1: BCR = 0x84060 [ 48.850565] k1iopex1: RAG = 0x117d8 [ 48.850568] k1iopex1: BCR = 0x84260 [ 49.278313] k1iopex1: SSC = 0x16 [ 49.278317] k1iopex1: IDBC = 0x1f [ 49.278344] k1iopex1: Contec 6464 DIO card on bus 1d; device 0 [ 49.278358] pci 0000:1d:00.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 49.289551] k1iopex1: contec 6464 dio pci2 = 0xa001 [ 49.289552] k1iopex1: contec32L diospace = 0xa000 [ 49.289556] k1iopex1: contec dio pci2 card number= 0x0 [ 49.289556] k1iopex1: contec32H diospace = 0xa004 [ 49.289557] k1iopex1: Contec 6464 DIO card on bus 1f; device 0 [ 49.289564] pci 0000:1f:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 49.291597] k1iopex1: contec 6464 dio pci2 = 0x9001 [ 49.291598] k1iopex1: contec32L diospace = 0x9000 [ 49.291601] k1iopex1: contec dio pci2 card number= 0x0 [ 49.291602] k1iopex1: contec32H diospace = 0x9004 [ 49.291603] k1iopex1: Contec 6464 DIO card on bus 21; device 0 [ 49.291610] pci 0000:21:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 49.293641] k1iopex1: contec 6464 dio pci2 = 0x8001 [ 49.293642] k1iopex1: contec32L diospace = 0x8000 [ 49.293645] k1iopex1: contec dio pci2 card number= 0x0 [ 49.293646] k1iopex1: contec32H diospace = 0x8004 [ 49.293646] k1iopex1: Contec 6464 DIO card on bus 23; device 0 [ 49.293653] pci 0000:23:00.0: PCI INT A -> GSI 36 (level, low) -> IRQ 36 [ 49.295683] k1iopex1: contec 6464 dio pci2 = 0x7001 [ 49.295684] k1iopex1: contec32L diospace = 0x7000 [ 49.295687] k1iopex1: contec dio pci2 card number= 0x0 [ 49.295688] k1iopex1: contec32H diospace = 0x7004 [ 49.295689] k1iopex1: Contec 6464 DIO card on bus 25; device 0 [ 49.295695] pci 0000:25:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 49.297729] k1iopex1: contec 6464 dio pci2 = 0x6001 [ 49.297729] k1iopex1: contec32L diospace = 0x6000 [ 49.297734] k1iopex1: contec dio pci2 card number= 0x0 [ 49.297734] k1iopex1: contec32H diospace = 0x6004 [ 49.297739] k1iopex1: Contec 1616 DIO card on bus 1a; device 0 [ 49.297745] pci 0000:1a:00.0: PCI INT A -> GSI 38 (level, low) -> IRQ 38 [ 49.299778] k1iopex1: contec 1616 dio pci2 = 0xb001 [ 49.299778] k1iopex1: contec 1616 diospace = 0xb000 [ 49.299782] k1iopex1: contec dio pci2 card number= 0x0 [ 49.299787] k1iopex1: Contec BO card on bus 27; device 0 [ 49.299793] pci 0000:27:00.0: PCI INT A -> GSI 32 (level, low) -> IRQ 32 [ 49.301487] k1iopex1: contec dio pci2 = 0x5001 [ 49.301487] k1iopex1: contec32L diospace = 0x5000 [ 49.301491] k1iopex1: contec dio pci2 card number= 0x0 [ 49.301496] k1iopex1: 5565 RFM card on bus 29; device c [ 49.301506] pci 0000:29:0c.0: PCI INT A -> GSI 34 (level, low) -> IRQ 34 [ 49.308518] k1iopex1: RFM address is 0x4026531840x [ 49.308519] k1iopex1: CSR address is 0xf8000000 [ 49.308526] k1iopex1: Board id = 0x65 [ 49.308528] k1iopex1: VMIC5565 set to single transfers [ 49.308529] k1iopex1: VMIC5565 ROGUE MASTER 1 = OFF [ 49.308531] k1iopex1: VMIC5565 ROGUE MASTER 0 = OFF [ 49.308532] k1iopex1: VMIC5565 Memory size = 128MBytes [ 49.308533] k1iopex1: DMA address is 0x4160753664x [ 49.308536] k1iopex1: 5565DMA at 0xffffc900170ce000 [ 49.308538] k1iopex1: 5565 INTCR = 0x251724032x [ 49.308539] k1iopex1: 5565 INTCR = 0x251723776x [ 49.308540] k1iopex1: 5565 MODE = 0x132483x [ 49.308542] k1iopex1: 5565 DESC = 0x1x [ 49.308545] k1iopex1: TSYNC GPS card on bus 1; device 0 [ 49.308548] k1iopex1: TSYNC PIC BASE 0 address = fa900000 [ 49.308552] k1iopex1: Remapped 0xffffc900170d0000 [ 54.323736] k1iopex1: TSYNC receiving YEAR info [ 54.323739] k1iopex1: date = 21 days 1: 6:1326762373 [ 54.323740] k1iopex1: bcd time = 1326762373 sec 325 milliseconds 310 microseconds 325306050 nanosec [ 54.323741] k1iopex1: Board sync = 1 [ 54.333731] k1iopex1: TSYNC receiving YEAR info [ 54.333733] k1iopex1: date = 21 days 1: 6:1326762373 [ 54.333734] k1iopex1: bcd time = 1326762373 sec 335 milliseconds 320 microseconds 335316230 nanosec [ 54.333735] k1iopex1: Board sync = 1 [ 54.333735] k1iopex1: 20 PCI cards found [ 54.333736] k1iopex1: *************************************************************************** [ 54.333737] k1iopex1: 3 ADC cards found [ 54.333738] k1iopex1: ADC 0 is a GSC_16AI64SSA module [ 54.333738] k1iopex1: Channels = 64 [ 54.333739] k1iopex1: Firmware Rev = 1 [ 54.333739] [ 54.333740] k1iopex1: ADC 1 is a GSC_16AI64SSA module [ 54.333740] k1iopex1: Channels = 64 [ 54.333741] k1iopex1: Firmware Rev = 1 [ 54.333741] [ 54.333742] k1iopex1: ADC 2 is a GSC_16AI64SSA module [ 54.333742] k1iopex1: Channels = 64 [ 54.333743] k1iopex1: Firmware Rev = 1 [ 54.333743] [ 54.333744] k1iopex1: *************************************************************************** [ 54.333744] k1iopex1: 3 DAC cards found [ 54.333745] k1iopex1: DAC 0 is a GSC_16AO16 module [ 54.333746] k1iopex1: Channels = 16 [ 54.333746] k1iopex1: Filters = None [ 54.333747] k1iopex1: Output Type = Differential [ 54.333747] k1iopex1: Firmware Rev = 8 [ 54.333748] [ 54.333748] k1iopex1: MASTER DAC SLOT 0 3 [ 54.333749] k1iopex1: DAC 1 is a GSC_16AO16 module [ 54.333749] k1iopex1: Channels = 16 [ 54.333750] k1iopex1: Filters = None [ 54.333750] k1iopex1: Output Type = Differential [ 54.333751] k1iopex1: Firmware Rev = 8 [ 54.333751] [ 54.333752] k1iopex1: MASTER DAC SLOT 1 4 [ 54.333752] k1iopex1: DAC 2 is a GSC_16AO16 module [ 54.333753] k1iopex1: Channels = 16 [ 54.333753] k1iopex1: Filters = None [ 54.333754] k1iopex1: Output Type = Differential [ 54.333754] k1iopex1: Firmware Rev = 8 [ 54.333755] [ 54.333755] k1iopex1: MASTER DAC SLOT 2 5 [ 54.333756] k1iopex1: *************************************************************************** [ 54.333757] k1iopex1: 0 DIO cards found [ 54.333757] k1iopex1: *************************************************************************** [ 54.333758] k1iopex1: 0 IIRO-8 Isolated DIO cards found [ 54.333759] k1iopex1: *************************************************************************** [ 54.333760] k1iopex1: 0 IIRO-16 Isolated DIO cards found [ 54.333760] k1iopex1: *************************************************************************** [ 54.333761] k1iopex1: 1 Contec 32ch PCIe DO cards found [ 54.333762] k1iopex1: 1 Contec PCIe DIO1616 cards found [ 54.333763] k1iopex1: 10 Contec PCIe DIO6464 cards found [ 54.333763] k1iopex1: 12 DO cards found [ 54.333764] k1iopex1: TDS controller 0 is at 10 [ 54.333765] k1iopex1: Total of 18 I/O modules found and mapped [ 54.333765] k1iopex1: *************************************************************************** [ 54.333766] k1iopex1: 1 RFM cards found [ 54.333767] k1iopex1: RFM 0 is a VMIC_5565 module with Node ID 9 [ 54.333768] k1iopex1: address is 0xffffc90027e80000 [ 54.333768] k1iopex1: *************************************************************************** [ 54.333769] k1iopex1: IRIG-B card found 2 [ 54.333770] k1iopex1: *************************************************************************** [ 54.333771] k1iopex1: Initializing space for daqLib buffers [ 54.434991] CPU 1 is now offline [ 54.435071] k1iopex1: Sync source = 4 [ 54.435072] k1iopex1: Waiting for EPICS BURT Restore = 1 [ 54.494967] k1iopex1: Waiting for EPICS BURT 0 [ 54.494968] k1iopex1: BURT Restore Complete [ 54.494971] k1iopex1: Initialized servo control parameters. [ 54.495970] k1iopex1: DAQ Ex Min/Max = 1 3 [ 54.495971] k1iopex1: DAQ XEx Min/Max = 3 53 [ 54.495972] k1iopex1: DAQ Tp Min/Max = 10001 10007 [ 54.495972] k1iopex1: DAQ XTp Min/Max = 10007 10507 [ 54.495983] k1iopex1: Have 395 CDS epics integer and 0 USR epics integer channels [ 54.495984] k1iopex1: Have int mem hole after CDS 1580 0 [ 54.495985] k1iopex1: DAQ EPICS INT DATA is at 0xffffc90023997028 with size 1580 [ 54.495986] k1iopex1: DAQ EPICS FLT DATA is at 0xffffc90023997658 [ 54.495987] k1iopex1: DAQ EPICS: Int = 395 Flt = 97 Filters = 22 Total = 514 Fast = 0 [ 54.495988] k1iopex1: DAQ EPICS: Number of Filter Module Xfers = 3 last = 2 [ 54.495989] k1iopex1: crc length epics = 2056 [ 54.495990] k1iopex1: xfer sizes = 4096 0 2056 2056 [ 54.495991] k1iopex1: Calling feCode() to initialize [ 54.495994] k1iopex1: ADC setup complete [ 54.495996] k1iopex1: DAC setup complete [ 54.495999] k1iopex1: writing BIO 10 [ 54.575890] k1iopex1: writing DAC 0 [ 54.575901] k1iopex1: writing DAC 1 [ 54.575912] k1iopex1: writing DAC 2 [ 54.575930] k1iopex1: Triggered the ADC [ 65.240135] k1visetmxt: startup time is 1326762384 [ 65.240137] k1visetmxt: cpu clock 3599825 [ 65.240138] k1visetmxt: EPICSM at 0x2fe81000 [ 65.240139] k1visetmxt: IPC at 0x27a26000 [ 65.240140] k1visetmxt: IOMEM at 0x27a2a000 size 0x33410 [ 65.240141] k1visetmxt: DAQSM at 0x1b925000 [ 65.240141] k1visetmxt: configured to use 16 cards [ 65.240142] k1visetmxt: Initializing PCI Modules [ 65.240143] k1visetmxt: 20 PCI cards found [ 65.240144] k1visetmxt: Found ADC at 0 0 [ 65.240144] k1visetmxt: Found ADC at 1 1 [ 65.240145] k1visetmxt: Found ADC at 2 2 [ 65.240146] k1visetmxt: Found DAC at 3 3 [ 65.240146] k1visetmxt: Found DAC at 4 5 [ 65.240147] k1visetmxt: Found 6464 DIN CONTEC at 8 0xa000 index 0 [ 65.240148] k1visetmxt: Found 6464 DOUT CONTEC at 13 0xa000 index 0 [ 65.240149] k1visetmxt: Found 6464 DIN CONTEC at 5 0xa004 index 1 [ 65.240150] k1visetmxt: Found 6464 DOUT CONTEC at 10 0xa004 index 1 [ 65.240151] k1visetmxt: Found 6464 DIN CONTEC at 9 0x9000 index 2 [ 65.240152] k1visetmxt: Found 6464 DOUT CONTEC at 14 0x9000 index 2 [ 65.240153] k1visetmxt: Found 6464 DIN CONTEC at 6 0x9004 index 3 [ 65.240153] k1visetmxt: Found 6464 DOUT CONTEC at 11 0x9004 index 3 [ 65.240155] k1visetmxt: Found 6464 DIN CONTEC at 7 0x6004 index 9 [ 65.240155] k1visetmxt: Found 6464 DOUT CONTEC at 12 0x6004 index 9 [ 65.240156] k1visetmxt: Found 32 DO CONTEC at 15 0x5000 [ 65.240157] k1visetmxt: 16 PCI cards found [ 65.240158] k1visetmxt: *************************************************************************** [ 65.240159] k1visetmxt: 3 ADC cards found [ 65.240159] k1visetmxt: ADC 0 is a GSC_16AI64SSA module [ 65.240160] k1visetmxt: Channels = 64 [ 65.240161] k1visetmxt: Firmware Rev = 0 [ 65.240161] [ 65.240161] k1visetmxt: ADC 1 is a GSC_16AI64SSA module [ 65.240162] k1visetmxt: Channels = 64 [ 65.240162] k1visetmxt: Firmware Rev = 1 [ 65.240163] [ 65.240163] k1visetmxt: ADC 2 is a GSC_16AI64SSA module [ 65.240164] k1visetmxt: Channels = 64 [ 65.240164] k1visetmxt: Firmware Rev = 2 [ 65.240165] [ 65.240165] k1visetmxt: *************************************************************************** [ 65.240166] k1visetmxt: 2 DAC cards found [ 65.240167] k1visetmxt: DAC 0 is a GSC_16AO16 module [ 65.240167] k1visetmxt: Channels = 64 [ 65.240168] k1visetmxt: Filters = None [ 65.240168] k1visetmxt: Firmware Rev = 3 [ 65.240169] [ 65.240169] k1visetmxt: DAC 1 is a GSC_16AO16 module [ 65.240170] k1visetmxt: Channels = 64 [ 65.240170] k1visetmxt: Filters = None [ 65.240171] k1visetmxt: Firmware Rev = 5 [ 65.240171] [ 65.240172] k1visetmxt: *************************************************************************** [ 65.240172] k1visetmxt: 0 DIO cards found [ 65.240173] k1visetmxt: *************************************************************************** [ 65.240174] k1visetmxt: 0 IIRO-8 Isolated DIO cards found [ 65.240175] k1visetmxt: *************************************************************************** [ 65.240176] k1visetmxt: 0 IIRO-16 Isolated DIO cards found [ 65.240176] k1visetmxt: *************************************************************************** [ 65.240177] k1visetmxt: 1 Contec 32ch PCIe DO cards found [ 65.240178] k1visetmxt: 0 Contec PCIe DIO1616 cards found [ 65.240178] k1visetmxt: 10 Contec PCIe DIO6464 cards found [ 65.240179] k1visetmxt: 11 DO cards found [ 65.240180] k1visetmxt: *************************************************************************** [ 65.240181] k1visetmxt: 1 RFM cards found [ 65.240181] k1visetmxt: RFM 0 is a VMIC_0 module with Node ID 0 [ 65.240182] k1visetmxt: address is 0xffffc90027e80000 [ 65.240183] k1visetmxt: *************************************************************************** [ 65.240184] k1visetmxt: Initializing space for daqLib buffers [ 65.240184] k1visetmxt: Epics burt restore is 0 [ 66.239214] k1visetmxt: Epics burt restore is 0 [ 67.238649] k1visetmxt: Epics burt restore is 0 [ 68.340104] CPU 2 is now offline [ 68.340166] k1visetmxt: Sync source = 8 [ 68.340168] k1visetmxt: Waiting for EPICS BURT Restore = 1 [ 68.400063] k1visetmxt: Waiting for EPICS BURT 0 [ 68.400064] k1visetmxt: BURT Restore Complete [ 68.400265] k1visetmxt: Initialized servo control parameters. [ 68.401265] k1visetmxt: DAQ Ex Min/Max = 20001 20216 [ 68.401266] k1visetmxt: DAQ XEx Min/Max = 20216 20266 [ 68.401266] k1visetmxt: DAQ Tp Min/Max = 30001 30646 [ 68.401267] k1visetmxt: DAQ XTp Min/Max = 30646 31146 [ 68.401280] k1visetmxt: Have 343 CDS epics integer and 144 USR epics integer channels [ 68.401281] k1visetmxt: Have int mem hole after CDS 1372 576 [ 68.401283] k1visetmxt: Have mem holes after CDS 1372 576 [ 68.401283] Need to cpy ints twice - size 1 = 1372 size 2 = 576 [ 68.401284] k1visetmxt: DAQ EPICS INT DATA is at 0xffffc9002fe82028 with size 1948 [ 68.401285] k1visetmxt: DAQ EPICS FLT DATA is at 0xffffc9002fe827c8 [ 68.401286] k1visetmxt: DAQ EPICS: Int = 487 Flt = 967 Filters = 2365 Total = 3819 Fast = 164 [ 68.401287] k1visetmxt: DAQ EPICS: Number of Filter Module Xfers = 5 last = 15 [ 68.401288] k1visetmxt: crc length epics = 15276 [ 68.401290] k1visetmxt: xfer sizes = 128 312 40044 40044 [ 68.401297] k1visetmxt: Initial state of contec6464 number 0 = 0x0 [ 68.401301] k1visetmxt: Initial state of contec6464 number 1 = 0x0 [ 68.401304] k1visetmxt: Initial state of contec6464 number 2 = 0x0 [ 68.401308] k1visetmxt: Initial state of contec6464 number 3 = 0x0 [ 68.401311] k1visetmxt: Initial state of contec6464 number 9 = 0x0 [ 68.401315] k1visetmxt: Calling feCode() to initialize [ 68.401317] k1visetmxt: size of data block = 0x80000 [ 68.401318] k1visetmxt: Dolphin num = 0 at 0x0 and 0x0 [ 68.401320] k1visetmxt: Setting card local=0 global = 0 channel=0 dac usage [ 68.401321] k1visetmxt: Setting card local=0 global = 0 channel=1 dac usage [ 68.401322] k1visetmxt: Setting card local=0 global = 0 channel=2 dac usage [ 68.401323] k1visetmxt: Setting card local=0 global = 0 channel=3 dac usage [ 68.401324] k1visetmxt: Setting card local=0 global = 0 channel=4 dac usage [ 68.401324] k1visetmxt: Setting card local=0 global = 0 channel=5 dac usage [ 68.401325] k1visetmxt: Setting card local=0 global = 0 channel=6 dac usage [ 68.401326] k1visetmxt: Setting card local=0 global = 0 channel=7 dac usage [ 68.401327] k1visetmxt: Setting card local=0 global = 0 channel=8 dac usage [ 68.401328] k1visetmxt: Setting card local=0 global = 0 channel=9 dac usage [ 68.401328] k1visetmxt: Setting card local=0 global = 0 channel=10 dac usage [ 68.401329] k1visetmxt: Setting card local=0 global = 0 channel=12 dac usage [ 68.401330] k1visetmxt: Setting card local=0 global = 0 channel=13 dac usage [ 68.401331] k1visetmxt: Setting card local=0 global = 0 channel=14 dac usage [ 68.401332] k1visetmxt: Setting card local=1 global = 2 channel=4 dac usage [ 68.401333] k1visetmxt: Setting card local=1 global = 2 channel=5 dac usage [ 68.401334] k1visetmxt: Setting card local=1 global = 2 channel=6 dac usage [ 68.401334] k1visetmxt: waiting to sync 27776 [ 68.975715] k1visetmxt: Synched 575437 [ 79.435863] k1visetmxp: startup time is 1326762398 [ 79.435864] k1visetmxp: cpu clock 3599825 [ 79.435866] k1visetmxp: EPICSM at 0x33f9e000 [ 79.435866] k1visetmxp: IPC at 0x27a26000 [ 79.435867] k1visetmxp: IOMEM at 0x27a2a000 size 0x33410 [ 79.435868] k1visetmxp: DAQSM at 0x1f947000 [ 79.435869] k1visetmxp: configured to use 16 cards [ 79.435869] k1visetmxp: Initializing PCI Modules [ 79.435870] k1visetmxp: 20 PCI cards found [ 79.435871] k1visetmxp: Found ADC at 0 0 [ 79.435871] k1visetmxp: Found ADC at 1 1 [ 79.435872] k1visetmxp: Found ADC at 2 2 [ 79.435873] k1visetmxp: Found DAC at 3 3 [ 79.435873] k1visetmxp: Found DAC at 4 4 [ 79.435874] k1visetmxp: Found DAC at 5 5 [ 79.435875] k1visetmxp: Found 6464 DIN CONTEC at 8 0x8000 index 4 [ 79.435876] k1visetmxp: Found 6464 DOUT CONTEC at 13 0x8000 index 4 [ 79.435877] k1visetmxp: Found 6464 DIN CONTEC at 6 0x8004 index 5 [ 79.435878] k1visetmxp: Found 6464 DOUT CONTEC at 11 0x8004 index 5 [ 79.435879] k1visetmxp: Found 6464 DIN CONTEC at 9 0x7000 index 6 [ 79.435880] k1visetmxp: Found 6464 DOUT CONTEC at 14 0x7000 index 6 [ 79.435880] k1visetmxp: Found 6464 DIN CONTEC at 7 0x7004 index 7 [ 79.435881] k1visetmxp: Found 6464 DOUT CONTEC at 12 0x7004 index 7 [ 79.435882] k1visetmxp: Found 6464 DIN CONTEC at 10 0x6000 index 8 [ 79.435883] k1visetmxp: Found 6464 DOUT CONTEC at 15 0x6000 index 8 [ 79.435884] k1visetmxp: 16 PCI cards found [ 79.435885] k1visetmxp: *************************************************************************** [ 79.435886] k1visetmxp: 3 ADC cards found [ 79.435886] k1visetmxp: ADC 0 is a GSC_16AI64SSA module [ 79.435887] k1visetmxp: Channels = 64 [ 79.435888] k1visetmxp: Firmware Rev = 0 [ 79.435888] [ 79.435888] k1visetmxp: ADC 1 is a GSC_16AI64SSA module [ 79.435889] k1visetmxp: Channels = 64 [ 79.435890] k1visetmxp: Firmware Rev = 1 [ 79.435890] [ 79.435890] k1visetmxp: ADC 2 is a GSC_16AI64SSA module [ 79.435891] k1visetmxp: Channels = 64 [ 79.435891] k1visetmxp: Firmware Rev = 2 [ 79.435892] [ 79.435892] k1visetmxp: *************************************************************************** [ 79.435893] k1visetmxp: 3 DAC cards found [ 79.435894] k1visetmxp: DAC 0 is a GSC_16AO16 module [ 79.435894] k1visetmxp: Channels = 64 [ 79.435895] k1visetmxp: Filters = None [ 79.435895] k1visetmxp: Firmware Rev = 3 [ 79.435896] [ 79.435896] k1visetmxp: DAC 1 is a GSC_16AO16 module [ 79.435897] k1visetmxp: Channels = 64 [ 79.435897] k1visetmxp: Filters = None [ 79.435898] k1visetmxp: Firmware Rev = 4 [ 79.435898] [ 79.435899] k1visetmxp: DAC 2 is a GSC_16AO16 module [ 79.435899] k1visetmxp: Channels = 64 [ 79.435900] k1visetmxp: Filters = None [ 79.435900] k1visetmxp: Firmware Rev = 5 [ 79.435900] [ 79.435901] k1visetmxp: *************************************************************************** [ 79.435902] k1visetmxp: 0 DIO cards found [ 79.435902] k1visetmxp: *************************************************************************** [ 79.435903] k1visetmxp: 0 IIRO-8 Isolated DIO cards found [ 79.435904] k1visetmxp: *************************************************************************** [ 79.435905] k1visetmxp: 0 IIRO-16 Isolated DIO cards found [ 79.435906] k1visetmxp: *************************************************************************** [ 79.435907] k1visetmxp: 0 Contec 32ch PCIe DO cards found [ 79.435907] k1visetmxp: 0 Contec PCIe DIO1616 cards found [ 79.435908] k1visetmxp: 10 Contec PCIe DIO6464 cards found [ 79.435909] k1visetmxp: 10 DO cards found [ 79.435909] k1visetmxp: *************************************************************************** [ 79.435910] k1visetmxp: 1 RFM cards found [ 79.435911] k1visetmxp: RFM 0 is a VMIC_0 module with Node ID 0 [ 79.435912] k1visetmxp: address is 0xffffc90027e80000 [ 79.435912] k1visetmxp: *************************************************************************** [ 79.435913] k1visetmxp: Initializing space for daqLib buffers [ 79.435914] k1visetmxp: Epics burt restore is 0 [ 80.434991] k1visetmxp: Epics burt restore is 0 [ 81.434428] k1visetmxp: Epics burt restore is 0 [ 82.535874] CPU 3 is now offline [ 82.535940] k1visetmxp: Sync source = 8 [ 82.535942] k1visetmxp: Waiting for EPICS BURT Restore = 1 [ 82.595838] k1visetmxp: Waiting for EPICS BURT 0 [ 82.595839] k1visetmxp: BURT Restore Complete [ 82.596062] k1visetmxp: Initialized servo control parameters. [ 82.597062] k1visetmxp: DAQ Ex Min/Max = 1 262 [ 82.597062] k1visetmxp: DAQ XEx Min/Max = 262 312 [ 82.597063] k1visetmxp: DAQ Tp Min/Max = 10001 10784 [ 82.597064] k1visetmxp: DAQ XTp Min/Max = 10784 11284 [ 82.597077] k1visetmxp: Have 392 CDS epics integer and 166 USR epics integer channels [ 82.597078] k1visetmxp: DAQ EPICS INT DATA is at 0xffffc90033f9f028 with size 2232 [ 82.597079] k1visetmxp: DAQ EPICS FLT DATA is at 0xffffc90033f9f8e0 [ 82.597080] k1visetmxp: DAQ EPICS: Int = 558 Flt = 993 Filters = 2871 Total = 4422 Fast = 202 [ 82.597081] k1visetmxp: DAQ EPICS: Number of Filter Module Xfers = 5 last = 61 [ 82.597082] k1visetmxp: crc length epics = 17688 [ 82.597085] k1visetmxp: xfer sizes = 1024 52 53720 53720 [ 82.597092] k1visetmxp: Initial state of contec6464 number 4 = 0x0 [ 82.597096] k1visetmxp: Initial state of contec6464 number 5 = 0x0 [ 82.597099] k1visetmxp: Initial state of contec6464 number 6 = 0x0 [ 82.597103] k1visetmxp: Initial state of contec6464 number 7 = 0x0 [ 82.597106] k1visetmxp: Initial state of contec6464 number 8 = 0x0 [ 82.597107] k1visetmxp: Calling feCode() to initialize [ 82.597111] k1visetmxp: size of data block = 0x80000 [ 82.597112] k1visetmxp: Dolphin num = 0 at 0x0 and 0x0 [ 82.597114] k1visetmxp: Setting card local=1 global = 1 channel=0 dac usage [ 82.597115] k1visetmxp: Setting card local=1 global = 1 channel=1 dac usage [ 82.597115] k1visetmxp: Setting card local=1 global = 1 channel=2 dac usage [ 82.597116] k1visetmxp: Setting card local=1 global = 1 channel=3 dac usage [ 82.597117] k1visetmxp: Setting card local=1 global = 1 channel=4 dac usage [ 82.597118] k1visetmxp: Setting card local=1 global = 1 channel=5 dac usage [ 82.597119] k1visetmxp: Setting card local=1 global = 1 channel=6 dac usage [ 82.597120] k1visetmxp: Setting card local=1 global = 1 channel=7 dac usage [ 82.597120] k1visetmxp: Setting card local=1 global = 1 channel=8 dac usage [ 82.597121] k1visetmxp: Setting card local=1 global = 1 channel=9 dac usage [ 82.597122] k1visetmxp: Setting card local=1 global = 1 channel=10 dac usage [ 82.597123] k1visetmxp: Setting card local=1 global = 1 channel=11 dac usage [ 82.597124] k1visetmxp: Setting card local=1 global = 1 channel=12 dac usage [ 82.597125] k1visetmxp: Setting card local=1 global = 1 channel=13 dac usage [ 82.597125] k1visetmxp: Setting card local=1 global = 1 channel=14 dac usage [ 82.597126] k1visetmxp: Setting card local=1 global = 1 channel=15 dac usage [ 82.597127] k1visetmxp: waiting to sync 42048 [ 82.954036] k1visetmxp: Synched 357565 [ 125.511848] cksum used greatest stack depth: 3344 bytes left