Reports 1-1 of 1 Clear search Modify search
VIS (General)
satoru.ikeda - 12:04 Friday 06 August 2021 (17831) Print this report
Routine confirmation of DGS maintenance day

Routine confirmation for DGS maintenance day.

Stepper motor
 [Stepper motor]
  Checked if the power supply can be controlled by BIO.
  Checked if the script can be started.
  Confirmed that the limit switch installed is green.
 [Check result]
 ETMY:
  Power control: No problem
  Limit SW: currently all NG, but will be adjusted

 ITMY:
  Power control: No problem
  Limit SW: F0YAW is NG (known)

 Other than above: No problem

Release Sensor
 [Confirmation]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : Abnormal, others are OK
 

Images attached to this report
Non-image files attached to this report
Comments to this report:
satoru.ikeda - 13:19 Friday 20 August 2021 (17968) Print this report

Routine confirmation of DGS maintenance day(Aug.20)

Performed routine check of DGS maintenance day.
No problems other than known problems.

Stepper motor
 [Checked]
  Checked if the power supply can be controlled by BIO.
  Checked if Script can be started.
  Check that the limit switch installed is green.
 [Check result]
 ETMY:
  Power control: No problem
  Limit SW: currently all NG, but will be adjusted in the future (known)

 ITMY:
  Power control: No problem
  Limit SW: F0YAW is NG (known)

 Other than above: No problem

Release Sensor
 [Confirmation]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : Abnormal, no other problems (known)
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:09 Friday 27 August 2021 (18040) Print this report

Routine confirmation of DGS maintenance day(Aug.27)

Performed routine check of DGS maintenance day.
No problems other than known problems.

Stepper motor
 [Checked]
  Checked if the power supply can be controlled by BIO.
  Checked if Script can be started.
  Check that the limit switch installed is green.
 [Check result]
 ETMY:
  Power control: No problem
  Limit SW: currently all NG, but will be adjusted in the future (known)

 ITMY:
  Power control: No problem
  Limit SW: F0YAW is NG (known)

 Other than above: No problem

Release Sensor
 [Confirmation]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : Abnormal, no other problems (known)
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:23 Friday 03 September 2021 (18144) Print this report

Routine confirmation of DGS maintenance day(Sep.3)

Performed routine check of DGS maintenance day.
No problems other than known problems.

Stepper motor
 [Checked]
  Checked if the power supply can be controlled by BIO.
  Checked if Script can be started.
  Check that the limit switch installed is green.
 [Check result]
 ETMY:
  Power control: No problem
  Limit SW: currently all NG, but will be adjusted in the future (known)

 ITMY:
  Power control: No problem
  Limit SW: F0YAW is NG (known)

 Other than above: No problem

Release Sensor
 [Confirmation]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : Abnormal, no other problems (known)
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:10 Friday 10 September 2021 (18227) Print this report

Routine confirmation of DGS maintenance day (Sep.10)

Routine checks for DGS maintenance day (Sep.10) were performed.
There are no problems except for the known ones.

Stepper motor
 [Checked that the power supply can be controlled by BIO.]
  Checked if power can be controlled by BIO.
  Check if Script can be started.
  Check that the limit switch installed is green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]

 NG:
  ETMX: NG
  SR2(IM): NG
   => Rebooted and recovered.
  MCI,STM1,IMMT1,IMMT2:NG
  AF_WFS,POP_POM,REFL_WFS,POP1,STM2: NG
   => Confirmation only, no recovery work done.
 OK:
  ITMX,ITMY,ETMY
  BS(IM,BF),SRM(IM,BF),SR2(BF),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM
  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:57 Friday 17 September 2021 (18295) Print this report

Routine confirmation of DGS maintenance day (9/17)

Routine checks for DGS maintenance day (9/17) were performed.
There are no problems except for the known ones.

Stepper motor
 [Checked that the power supply can be controlled by BIO.]
  Checked if power can be controlled by BIO.
  Check if Script can be started.
  Check that the limit switch installed is green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]

 NG:
  BS_BF:NG
   => Rebooted and recovered.
  SR2_STM:NG
   => The power supply was almost disconnected, so I asked Hirata-san to plug it back in.
  MCI,STM1,IMMT1,IMMT2:NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ITMX,ITMY,ETMX,ETMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.
  

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:13 Friday 24 September 2021 (18347) Print this report

Routine confirmation of DGS maintenance day (9/24)

Routine checks for DGS maintenance day (9/24) were performed.
There are no problems except for the known ones.

Stepper motor
 [Checked that the power supply can be controlled by BIO.]
  Checked if power can be controlled by BIO.
  Check if Script can be started.
  Check that the limit switch installed is green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]

 NG:
  SR3_IM: NG
  ETMX: NG
   ETMY: NG => Both rebooted and came back.
  ETMY: NG
   => Can't connect to the rebooter either. Power disconnected? Unknown cause. Will check on Monday.
  SR2_STM: NG
   => The rebooter is not installed yet, so I will install it next week and get it back.

  MCI,STM1,IMMT1,IMMT2:NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:13 Monday 27 September 2021 (18356) Print this report

[Ikeda, Yasui-san, Nakagaki-san]

Two issues found during routine maintenance have been addressed.

ETMY: NG -> OK
 => Can't connect to the rebooter either. Was the power supply disconnected? Cause unknown. Will check on Monday. 
 
 [Investigation result]
  It was found that Picomotor and Picomotor's rebooter did not respond to ping during the regular maintenance on 9/27.
  In the subsequent investigation, it was found that the temperature control device did not respond to pings as well.
  When we checked the log of the temperature control device, we found that the connection was lost around 11:23 on September 20.
  When I checked the log of the temperature control device, I found that the connection had been lost around 11:23 a.m. on 9/20. The backbone LAN cable was plugged into the power supply port of the network SW (S2112636:GS108TV3) placed in the VIS mini rack.
   This LED was turned off and it was found to be unconnected.
 This network SW had an AC adapter and a LAN connected to the PoE power supply port.
   The network was restored by removing the AC adapter or connecting the AC adapter to a port other than the power supply port.
 [Details]
  The AC adapter was removed because it was found that PoE power supply was available.
   Confirmed that it is connected to the network.

SR2_STM: NG -> OK
 => The rebooter is not installed yet, so I will install it next week to get it back.
 => Installed a switch (S2113327) for power control in Picomotor of SR2_STM.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:18 Friday 01 October 2021 (18418) Print this report

Routine confirmation of DGS maintenance day (10/01)

Routine check for DGS maintenance day (10/01) was performed.
Two problems were found.
The limit switch of BS_F0YAW was in contact with both L and R.

The LAN of ETMY Pico and the temperature control device could not be connected.
 => I changed the power supply of the network SW to PoE on 9/27, but it recurred after that.

Stepper motor
 [Checked]
  Checked if the power can be controlled by BIO.
  Checked if Script can be started.
  Checked that the limit switch installed is green.
 [Check result]
  The limit switch of BS_F0YAW was abnormal because both L and R were in contact.
  => Confirmation required.
  No other problems.

Release Sensor
 [Confirmation]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  ETMY
   => Unable to access from LAN after 9/27 11:38.
    Will check on Monday.
  SR2_IM,SR2_STM
   => Both have been rebooted and recovered.

  MCI,STM1,IMMT1,IMMT2:NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ETMX,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(BF),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Control
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
 ETMY:NG
   => Unable to access from LAN after 9/27 11:38.
    Will check on Monday.
  Other than the above, everything was OK.
 

Images attached to this comment
Non-image files attached to this comment
naoatsu.hirata - 17:18 Tuesday 05 October 2021 (18459) Print this report

>Stepper motor

>[Check result]
> The limit switch of BS_F0YAW was abnormal because both L and R were in contact.
> => Confirmation required.

I connected the in-air cable, and confirmed limit switches work well.

Images attached to this comment
satoru.ikeda - 16:27 Wednesday 06 October 2021 (18479) Print this report

[Ikeda, Oshino-san].

About the network SW installed in EYV's VIS mini rack being turned off.
I asked Oshino-san to turn off and on the PoE power supply port (Port 17) to which the network SW of the VIS mini rack is connected.
(This was done at around 10:53 on 2021-09-27)
We decided to wait and see if the system works stably after the reboot.
Currently, as of 16:22, it is normal

Non-image files attached to this comment
satoru.ikeda - 16:28 Friday 08 October 2021 (18514) Print this report

Routine confirmation of DGS maintenance day (Oct.8)

Stepper motor
 [Contents of check]
  Checked if the power supply can be controlled by BIO.
  Check if Script can be started.
  Checked that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  No problem

  MCI,STM1,IMMT1,IMMT2: NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature regulator
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:51 Friday 15 October 2021 (18596) Print this report

Routine check on DGS maintenance day (Oct. 15)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  No problem

  MCI,STM1,IMMT1,IMMT2: NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Control
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Non-image files attached to this comment
satoru.ikeda - 17:39 Friday 22 October 2021 (18669) Print this report

Routine check for DGS maintenance day (Oct. 22)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  No problem

  MCI,STM1,IMMT1,IMMT2: NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature regulator
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:35 Friday 29 October 2021 (18738) Print this report

Routine check for DGS maintenance day (Oct. 29)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  No problem

  MCI,STM1,IMMT1,IMMT2: NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Control
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:19 Friday 05 November 2021 (18783) Print this report

Routine check for DGS maintenance day (11/05)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  SR3(BF), BS(IM)
   => Rebooted by rebooter.

  MCI,STM1,IMMT1,IMMT2:NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.
  
 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature regulator
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:45 Friday 12 November 2021 (18876) Print this report

Routine check for DGS maintenance day (11/12)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
 Known only

  MCI,STM1,IMMT1,IMMT2: NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
   => Confirmation only, no recovery work done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCF(MCO,MCI),MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature regulator
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:29 Friday 26 November 2021 (19016) Print this report

Routine check for DGS maintenance day (Nov. 26)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : abnormal, no other problems (known)

Picomotor
 [Checked]
  PingTest is performed.
 [Result]
 NG:
  SR3_IM, ITMX: NG
   => Rebooted and restored.

  MCI,STM1,IMMT1,IMMT2:NG
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1: NG
  MCF(MCO,MCI):NG => New NG friends this week
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
 MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed since it is ON only when used.

Temperature controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:39 Friday 03 December 2021 (19076) Print this report

Routine check for DGS maintenance day (12/03)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem
 However, ETMX is in use, so not confirmed yet.

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem
 ETMX_F1_1 : Abnormality disappeared as of last week (Nov.25 10:32:50 JST).
  They are replacing the flip cable.
 
Picomotor
 [check details]
  Performed PingTest
 [Check result]
  No problem (all NGs are known)

 NG:
  MCI,STM1,IMMT1,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed since it is ON only when used.

Temperature controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:55 Friday 10 December 2021 (19167) Print this report

Routine check for DGS maintenance day (Dec. 10)

Stepper motor
 [Checked if the power supply can be controlled by BIO.]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem.
 However, ETMX is not confirmed yet because it is in use.

Release Sensor
 [Confirmed]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem
 
Picomotor
 [check details]
  Performed PingTest
 [Check result]
  SR2_IM:NG
   =>Restarted and restored.

 NG:
  MCI,STM1,IMMT1,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE
  OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed since it is ON only when used.

Temperature controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:35 Friday 17 December 2021 (19265) Print this report

Routine check for DGS maintenance day (Dec. 17)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem.
 However, ETMX is not confirmed yet because it is in use.

Release Sensor
 [Confirmed]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG:
  MCI,STM1,,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:07 Friday 07 January 2022 (19391) Print this report

Routine check on DGS maintenance day (1/7)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem.

 The following settings were made.
  Set the software limit of ETMX and ITMX GAS.
  Enable the HW limit switch of SRM.

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG:
  ETMY (rebooted on 2022/1/6)
  PR2_IM
   => Restarted.

  MCI,STM1,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(BF),PR3(IM,BF)
  MCE,IMMT1,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature control
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision air conditioning
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 13:28 Friday 14 January 2022 (19468) Print this report

Routine check on DGS maintenance day (1/14)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG:
  MCI,STM1,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision air processer
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem
 

Images attached to this comment
satoru.ikeda - 14:58 Friday 21 January 2022 (19525) Print this report

Routine check for DGS maintenance day (1/21)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem.

 The following settings were made.
  Change the value of software limit of ETMX and ITMX GAS (E2213706-v3)

 The HW limit switches on the ETMX IP were all red because the cable had been unplugged during the leak test, but later checks showed that they were all green, so no problem.
  

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG: 
  MCI,STM1,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision air processer
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem

 

Images attached to this comment
satoru.ikeda - 17:02 Friday 28 January 2022 (19623) Print this report

Routine check for DGS maintenance day (1/28)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem(BS was in use, so we'll skip it this time.)

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG: 
  MCI,STM1,IMMT2
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision Air Processer
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:19 Friday 04 February 2022 (19687) Print this report

Routine check for DGS maintenance day (Feb. 4)

Stepper motor
 [Check contents]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Check that the limit switch installed is green.
 [Check result]
  No problem (BS was in use, so it was not used this time)

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Control
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision air Processer
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:42 Friday 18 February 2022 (19836) Print this report

Stepper motor
 [Check contents]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Check that the limit switch installed is green.
 [Check result]
  No problem (BS was in use, so it was not used this time)

Release Sensor
 [Checked]
 Confirmed that the Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision air Processer
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 11:05 Friday 25 February 2022 (19893) Print this report

Routine check for DGS maintenance day (Feb. 25)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO.
  Check if the script can be started.
  Confirmed that the limit switch installed is in Green.
 [Check result]
  No problem (ITMY was in use, so it was not used this time)

Release Sensor
 [Confirmed that the Release Sensor is 0.]
 Confirmed that Release Sensor is 0. 1: Seated
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Checked]
  Ping Test is performed.
 [Check result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not confirmed because it is ON only when used.

Temperature Controller
 [Checked]
 Check if the temperature acquisition is working properly.

 [Check result]
  No problem

Precision air Processer
 [Checked]
 Is the temperature acquisition function working properly?

 [Check result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 10:35 Friday 04 March 2022 (19977) Print this report

Routine check for DGS maintenance day(May.4) 

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that the script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem (ITMY was in use, so it was not used this time)

Release Sensor
 [Contents to be checked]
 Confirmation that Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 11:06 Friday 11 March 2022 (20054) Print this report

Routine check on DGS maintenance day (Mar.11)

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that the script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem
  
Release Sensor
 [Contents to be checked].
 Confirm Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 13:44 Friday 18 March 2022 (20154) Print this report

Routine check on DGS maintenance day (3/18)

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that the script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem
  
Release Sensor
 [Contents to be checked].
 Confirm Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,REFL_WFS,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM

  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 10:24 Friday 25 March 2022 (20228) Print this report

Routine check on DGS maintenance day (3/25)

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that the script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem
  
Release Sensor
 [Contents to be checked].
 Confirm Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem
  SDF(20.0->23.0) of K1:AIR-CENTER_SRX1_S1 is ACCEPTED.
 

Images attached to this comment
satoru.ikeda - 14:57 Friday 01 April 2022 (20330) Print this report

Routine check on DGS maintenance day (4/1)

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem
  
Release Sensor
 [Contents to be checked].
 Confirm Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,,OM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:28 Friday 08 April 2022 (20416) Print this report

Routine checks on DGS maintenance day (4/8)

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that the script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem
  
Release Sensor
 [Contents to be checked].
 Confirm Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF,STM),SR3(IM,BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS, (new check item)POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator(new check item):
 (Check details)
 Is there a ping response?
 Are all EPICS channels live?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm]

 [Check result].
 X and Y PLLs are working properly.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:22 Friday 15 April 2022 (20499) Print this report

Routine check on DGS maintenance day (4/15)

Stepper motor
 [Check details]
  Check if power supply can be controlled by BIO
  Confirmation that the script can be started
  Check that the limit switches installed are green.
 [Result]
  No problem
  
Release Sensor
 [Contents to be checked].
 Confirm Release Sensor is 0, 1: Seated
 [Confirmation Result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation details]
  Perform PingTest
 [Result]
  Known only

 NG: 
  ETMX,SR2(IM,STM),SR3(IM)
   => It had been hanging for a while. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery work was performed.

 OK:
  ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(BF),SR3(BF)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS, (new check item)POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature Controller
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

Precision Air Processer
 [Check details]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator:
 (Check details)
 Is there a ping response?
 Are all EPICS channels live?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm],[ALS FG]-[Xarm],[Yarm].
 [Check result].
 X and Y PLLs are working properly.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:51 Friday 22 April 2022 (20554) Print this report

Routine check on DGS maintenance day (4/22)

Stepper motor
 [Checked]
  Check if power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  ETMX
   => Hung for a long time. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS, (new check item)POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used.

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] ・Is the temperature acquisition working properly?
  No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation) ・Is there a ping response?
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:13 Friday 13 May 2022 (20722) Print this report

DGS maintenance day (5/13) regular checks

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  ETMY, BS(IM,BF),SR2(IM,STM),SR3(IM)
   => Hung for a long time. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS, (new check item)POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used.

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?
  No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
  ・Is there a ping response?
  Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 20:16 Friday 20 May 2022 (20819) Print this report

DGS Regular maintenance day (5/20) 

Stepper motor
 [Check the motor.]
  Check if power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  PR2(IM),SR3(BF)
   => It was hung and recovered.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Checked only, no recovery work was done.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,STM)
  PRM(IM,BF),PR2(BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS, (new check item)POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used.

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] ・Is the temperature acquisition working properly?
  No problem

Precision air conditioning
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation) ・Is there a ping response?
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

Images attached to this comment
satoru.ikeda - 13:52 Thursday 26 May 2022 (20896) Print this report

DGS Regular maintenance day(5/26)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  ETMX
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation) ・Is there a ping response?
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:55 Friday 03 June 2022 (21013) Print this report

DGS Regular maintenance day(6/3)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  ETMY,SR2_IM
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 12:52 Friday 10 June 2022 (21095) Print this report

DGS Regular maintenance day(6/10)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  SR2_IM,PR3_IM
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:10 Friday 17 June 2022 (21170) Print this report

DGS Regular maintenance day(6/17)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
ITMX is suspended for maintenance at other locations.
  
Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  ETMY, PR3(IM),BS(BF)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 21:46 Friday 24 June 2022 (21274) Print this report

DGS Regular maintenance day(6/24)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  BS(IM)
   => Hang. Not Recovery.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:51 Friday 01 July 2022 (21354) Print this report

DGS Regular maintenance day(7/1)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  BS(IM)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:21 Friday 08 July 2022 (21431) Print this report

DGS Regular maintenance day(7/8)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  BS(BF), PR3(IM)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
satoru.ikeda - 13:10 Friday 22 July 2022 (21569) Print this report

DGS Regular maintenance day(7/22)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  ETMX(BF), PR3(IM)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
satoru.ikeda - 16:48 Friday 29 July 2022 (21653) Print this report

DGS Regular maintenance day(7/29)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  SR3(IM)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:14 Friday 05 August 2022 (21715) Print this report

DGS Regular maintenance day(8/5)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  SR3(IM)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:30 Friday 19 August 2022 (21832) Print this report

DGS Regular maintenance day(8/19)

All TestPoints were cleared before maintenance.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  SR2(IM),ETMY
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 13:49 Friday 26 August 2022 (21918) Print this report

DGS Regular maintenance day(8/26)

All TestPoints were cleared before maintenance.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG: 
  SR2(IM),SR2(STM),PR3(IM)
   => Hang. Rebooted.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:20 Friday 09 September 2022 (22054) Print this report

DGS Regular maintenance day(9/9)

All TestPoints were cleared before maintenance.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:   
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:29 Friday 16 September 2022 (22135) Print this report

DGS Regular maintenance day(9/17)

All TestPoints were cleared before maintenance.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  ITMX is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  BS(BF)
   => Hung, rebooted and recovered.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:13 Friday 30 September 2022 (22278) Print this report

DGS Regular maintenance day(9/30)

All TestPoints were cleared before maintenance.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  BS(BF),SR2(IM)
   => Hung, rebooted and recovered.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:23 Friday 07 October 2022 (22406) Print this report

DGS Regular maintenance day(10/07)

All TestPoints were cleared before maintenance.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  BS(BF),SR2(IM)
   => Hung, rebooted and recovered.
  
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
satoru.ikeda - 13:38 Friday 14 October 2022 (22506) Print this report

DGS Regular maintenance day(10/14)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  PR3(IM)
  => Hang, reboot and recover
    
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0 and 1 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:33 Friday 21 October 2022 (22616) Print this report

DGS Regular maintenance day(10/21)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:11 Friday 28 October 2022 (22721) Print this report

DGS Regular maintenance day(10/28)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  BS(BF) : Hang, returned
 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:30 Friday 04 November 2022 (22793) Print this report

DGS Regular maintenance day(11/4)

First cleared TP to 0.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  BS(IM),ETMY: Hang, rebooted
 
  MCI,STM1,
  AS_WFS,POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.

Images attached to this comment
satoru.ikeda - 14:18 Friday 11 November 2022 (22890) Print this report

DGS Regular maintenance day(11/4)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS is suspended for maintenance at other locations.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:58 Friday 18 November 2022 (22962) Print this report

DGS Regular maintenance day(11/18)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  This week was skipped due to other work priorities.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 18:58 Friday 25 November 2022 (23036) Print this report

DGS Regular maintenance day(11/18)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 11:13 Friday 02 December 2022 (23102) Print this report

DGS Regular maintenance day(12/2)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:31 Friday 09 December 2022 (23192) Print this report

DGS Regular maintenance day(12/9)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 18:11 Friday 16 December 2022 (23270) Print this report

DGS Regular maintenance day(12/16)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:30 Friday 23 December 2022 (23351) Print this report

DGS Regular maintenance day(12/23)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:51 Friday 06 January 2023 (23481) Print this report

DGS Regular maintenance day(1/6)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  SR2 GAS and IP do not turn on when BIO is turned on

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR2(IM) : Not restored today due to other work priorities

  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 11:55 Tuesday 10 January 2023 (23504) Print this report

Investigated a problem found during Jan.6 maintenance where the StepperMotor in SR2 would not turn on.

Problem
Ping error on both GAS and IP of SR2

Confirmation Result
BIO connection was normal. Fig. 1
When the BIO was turned on and off, the LEDs on the Stepper switched normally to the On and Off states. Fig.2
The LED on the network switch of the VIS mini-rack was always on when the Stepper was turned on.Fig.3
It blinks when it is normal. Other Ports were blinking.

Coping
Turned on the power of the network SW again (because it is PoE power supply, unplugged and plugged in the LAN of Port.1).

Confirmation
Confirmed that the SW was blinking.
Turned on the Stepper's BIO and confirmed the connection from the script.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:47 Friday 13 January 2023 (23564) Print this report

DGS Regular maintenance day(1/13)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:32 Friday 20 January 2023 (23659) Print this report

DGS Regular maintenance day(1/20)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POP_POM,POS_POM,POM1
  MCF(MCO,MCI)
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:27 Friday 27 January 2023 (23723) Print this report

DGS Regular maintenance day(1/27)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:49 Friday 03 February 2023 (23829) Print this report

DGS Regular maintenance day(2/3)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  PR0(PRM_GAS,PR3_GAS):NG
   => Network SW was abnormal. Recovered.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:43 Friday 10 February 2023 (23922) Print this report

DGS Regular maintenance day(2/10)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 and 2 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:36 Friday 24 February 2023 (24143) Print this report

DGS Regular maintenance day(2/24)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
  BS not confirmed because it was used.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 13:22 Friday 10 March 2023 (24348) Print this report

DGS Regular maintenance day(3/10)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem
   Both GAS and IP of BS and SRM had stopped pinging.
   I asked Nakagaki-San to turn on the network SW in the VIS rack again.
   The LED of the stepper driver on the network switch was not blinking. It remained lit.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:43 Friday 17 March 2023 (24452) Print this report

DGS Regular maintenance day(3/10)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 9:47 Friday 24 March 2023 (24522) Print this report

DGS Regular maintenance day(3/24)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problem

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:16 Friday 31 March 2023 (24627) Print this report

DGS Regular maintenance day(3/31)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  Both ITMY IP and GAS had problems connecting, restored.
  No other problems.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 10:51 Friday 07 April 2023 (24710) Print this report

DGS Regular maintenance day(4/7)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problems.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
satoru.ikeda - 13:09 Friday 21 April 2023 (24912) Print this report

DGS Regular maintenance day(4/21)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problems.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 11:22 Friday 12 May 2023 (25210) Print this report

DGS Regular maintenance day(5/12)

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problems.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  SR3(IM)
  => Recovered.
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:02 Tuesday 23 May 2023 (25347) Print this report

DGS Regular maintenance day(5/23)

Final confirmation just before O4a.

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  No problems.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 9:20 Tuesday 30 May 2023 (25436) Print this report

DGS Regular maintenance day(5/30)

Confirmation during O4a

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  Lock loss when turned on, also no off-loading this week, so no confirmation is foregone.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 9:24 Tuesday 06 June 2023 (25519) Print this report

DGS Regular maintenance day(6/6)

Confirmation during O4a

Stepper motor
 [Checked]
  Check if the power supply can be controlled by BIO
  Check if the script can be started
  Checked that the limit switches installed are green.
 [Check result]
  Lock loss when turned on, also no off-loading this week, so no confirmation is foregone.

Release Sensor
 [Checked the Release Sensor.]
 Checked that Release Sensor is 0, 1: Seated.
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Confirmation]
  PingTest is performed.
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Checked]
 Is the temperature acquisition working properly?

 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Check Contents]
 Is the temperature acquisition working properly?

 [Result]
  No problem

FunctionGenerator
 (Confirmation)
 Is there a ping response?
 Are all EPICS channels alive?
  [sitemap]-[Commissioning]-[ALS FG]-[Xarm],[Yarm].
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Confirmation)
 Check if it is possible to login to the control PC.
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 10:58 Tuesday 13 June 2023 (25589) Print this report

DGS Regular maintenance day(6/13)

Confirmation during O4a
Since the confirmation details are the same as last week, we omit the description.

Stepper motor
[Check result]
Lock loss when turned on, also no off-loading this week, so no confirmation is foregone.

Release Sensor
[Check result]
ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
[Result]
Only known

NG:
MCI,STM1,
POS_POM,POM1
=> Confirmation only, no recovery operation was performed.

OK:
ETMX,ETMY,ITMX,ITMY
BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
POP_POM, MCF(MCO,MCI)
PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
[Check result]
Is the temperature acquisition working properly?
=> No problem

Precision air Processer
[Result]
No problem

FunctionGenerator
[Check result]
X and Y PLLs are working properly.

HWP control PC
(Result)
Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 9:16 Tuesday 20 June 2023 (25646) Print this report

DGS Regular maintenance day(6/20)

Confirmation during O4a

Stepper motor
 [Check result]
  Lock loss when turned on, also no off-loading this week, so no confirmation is foregone.

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:52 Friday 07 July 2023 (25898) Print this report

DGS Regular maintenance day(7/7)

Stepper motor
 [Check result] 
  SR3 could not be turned on.
  PRM and PR3 were in use and not tested.
 

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 12:43 Friday 21 July 2023 (26056) Print this report

DGS Regular maintenance day(7/21)

Stepper motor
 [Check result]
  SR3 could not be turned on.
     => Recovered.

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:36 Friday 28 July 2023 (26126) Print this report

DGS Regular maintenance day(7/28)

Stepper motor
 [Check result]
  No problem

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 14:44 Friday 04 August 2023 (26203) Print this report

DGS Regular maintenance day(8/4)

Stepper motor
 [Check result]
  No problem

   Skip SRM, PRM

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:11 Friday 25 August 2023 (26482) Print this report

DGS Regular maintenance day(8/25)

Stepper motor
 [Check result]
  No problem

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 15:31 Friday 01 September 2023 (26584) Print this report

DGS Regular maintenance day(9/1)

Stepper motor
 [Check result]
  No problem

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 16:22 Friday 08 September 2023 (26697) Print this report

DGS Regular maintenance day(9/8)

Stepper motor
 [Check result]
  Skiped

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.
 

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 12:46 Friday 15 September 2023 (26772) Print this report

DGS Regular maintenance day(9/15)

Stepper motor
 [Check result]
 => No problem

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 17:51 Friday 22 September 2023 (26863) Print this report

DGS Regular maintenance day(9/22)

Stepper motor
 [Check result]
  Skiped

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
satoru.ikeda - 13:10 Friday 17 November 2023 (27653) Print this report

DGS Regular maintenance day(11/17)

Stepper motor
 [Check result]
  No problem

Release Sensor
 [Check result]
 ETMX, ETMY, ITMX, ITMY : No problem

Picomotor
 [Result]
  Only known

 NG:
  MCI,STM1,
  POS_POM,POM1
   => Confirmation only, no recovery operation was performed.

 OK:
  ETMX,ETMY,ITMX,ITMY
  BS(IM,BF),SRM(IM,BF),SR2(IM,BF),SR3(IM,BF,STM)
  PRM(IM,BF),PR2(IM,BF),PR3(IM,BF)
  MCE,IMMT1,IMMT2,OMMT1,OMMT2,OSTM
  REFL_WFS,POP,POP2,POS,POS2,POP_WFS,AS_WFS
  POP_POM, MCF(MCO,MCI)
  PCAL(EX1,EX2,EY1,EY2):Not checked because it is ON only when used

Temperature controller
 [Check result] 
  Is the temperature acquisition working properly?
  => No problem

Precision air Processer
 [Result]
  No problem

FunctionGenerator
 [Check result]
 X and Y PLLs are working properly.

HWP control PC
 (Result) 
 Both k1hwp0, 1 , 2, 3 and 4 are OK.

Images attached to this comment
Non-image files attached to this comment
Search Help
×