Reports 1-1 of 1 Clear search Modify search
VIS (General)
tomohiro.yamada - 1:01 Tuesday 19 November 2019 (11623) Print this report
Coherence between cryopayloads' damp signal and DARM

[Yamada]

Related to #11522 and #11571.

As reported in #11522, damping filters contribute DARM. So we made roll-off frequency low in cryopayload damping filters (ETMY, ITMX, ITMY, except for BP filtes, ), #11571.

I compared 3 periods: Nov. 13th 22:04:00 (no roll off), Nov.13th 23:15:00 (ETMX_MN_MNOLDAMP_P roll off) and Nov.17th 22:32:00(all filtes for ETMY, ITMX, ITMY roll off).

Comparing Nov.13th 22:04:00 and 23:15:00, we can cleary see reduction of contribution of damping filter in DARM signal.

Comparing Nov. 13th 23:15:00 and Nov. 17th 22:32:00, we can see reduction of coherences, however, the effect was unvisible in DARM signal.

Images attached to this report
Comments to this report:
takaaki.yokozawa - 3:24 Tuesday 19 November 2019 (11626) Print this report

I also checked for BS, SR2, SR3.

Images attached to this comment
Search Help
×

Warning

×