hirotaka.yuzurihara - 16:22 Thursday 20 January 2022 (19512) Print this report
Summary page update : Added microphones (EXA, EYA) in PEM tab

During working on data quality evaluation, I found that several microphones are missing on summary page. So, I added them on summary page.

And also I found the microphon at EYA booth has a strange spectrum, which looks like just ADC noise.

As I checked by Pastavi, it's happening from sometime in the period between 2021 April 1 and  2021 May 1.

 

Images attached to this report
Comments to this report:
takaaki.yokozawa - 12:41 Friday 21 January 2022 (19522) Print this report
I found that the ACO power supply was turned off, we turned ON this morning. Now it may work.
hirotaka.yuzurihara - 12:33 Monday 24 January 2022 (19540) Print this report

Yokozawa-san, thank you very much for the recovery.

Now the microphone at EYA looks working fine. (summary page)

Note that, for future worker, the microphone ( K1:PEM-MIC_EYA_BOOTH_EYA_Z_OUT_DQ ) and accelerometer on Pcal@EYA ( K1:PEM-ACC_EYA_TABLE_TX_Z_OUT_DQ, K1:PEM-ACC_EYA_TABLE_RX_Z_OUT_DQ ) were unavailable between 2021 April 1 and 2022 Jan 21.