FCL (Air)
shinji.miyoki - 11:21 Tuesday 07 December 2021 (19105) Print this report
20.5 -> 19.5 for the temp setting of precision cooler near SR3

I have changed the temp setting from 20.5 to 19.5 for the precision cooler near SR3 to reduce the temp in the corner station. We will monitor the temp. 

Comments to this report:
shinji.miyoki - 15:24 Tuesday 07 December 2021 (19113) Print this report

Because there seems to be no serious rapid change of temp, I changed from 19.50 -> 19.00. (18.00 is the minimum setting temp for this precision cooler)

By the way, the hot water was abandoned from this precision cooler to the gutter in the corner station as the result of the heat exchange from the air to water. However, I noticed that this hot water heat up again the air in the corner station even if the hot water is mixed with cold water in the gutter, and even if most gutters were covered with concrete lids. I will ask Hayakawa-kun to abandon the hot water not in the same area but in the pre-room at least.