Test for template files for spectra and PLANT measurement

[YamaT, Ushiba]

Abstract:
I tested the template files and automeasurement scripts for spectra and PLANT measurements.
Preparation of  templates for spectra has been finished and they can be measured from the scripts.
Preparation of template for PLANT measurement is ongoing and now we can measure the mechanical transfer function of following DoFs from scripts:
IP{L,T,Y},BF{L,T,V,R,P,Y},{F0,F1,F2,F3,BF} GAS,MN{L,T,R,P,Y}.

Details:
We prepared template and automeasurement scripts for spectra measurements.
Measured data was stored at /kagra/Dropbox/Measurements/VIS/SPECTRA/{DIRNAME}/ with the name of SPE_{SUSNAME}_{STATE}_{SIGNALS}_{REFNUM}.xml.
{SUSNAME} is like ITMX, ETMX, and so on.
{STATE} is the guardian state when the measurement starts such as SAFE, ISOLATED, ALIGNED, and so on.
{SIGNALS} is classification of signals and currently I prepared IP, BF, GAS, PAYLOAD, and OPLEV.
{REFNUM} is a serial number of the measurement like 0001, 0002, and so on.
{DIRNAME} is a round down numbers of REFNUM like 0, 100, 200, and so on.

Also, we prepared template and automesurement scripts for TF measurement.
Measured data was stored at /kagra/Dropbox/Measurements/VIS/PLANT/{SUSNAME}/{DIRNUM}/ with the name of PLANT_{SUSNAME}_{STATE}_{STAGE}_{PORT}_{DOF}_{REFNUM}.xml.
{STAGE} is a stage we excite like IP, BF, F0, MN, and so on.
{PORT} is a excitation port like TEST and COILOUT.
{DOF} is a degrees of freedom we excite like L, T, V, ... or H1, H2, and so on.

I continue to run the script tonight and will report measurement results tomorrow.

Comments to this report:
takafumi.ushiba - 12:39 Tuesday 26 October 2021 (18686) Print this report

I attached the screenshots of measure data for ITMX PLANT yesterday.
These data can be seen in the directry /kagra/Dropbox/Measurements/VIS/PLANT/ITMX/0/ as I explained in the original post.
For ETMX results can be seen in the directry /kagra/Dropbox/Measurements/VIS/PLANT/ETMX/0/ as well.

During the check of data, I found several templates have wrong reference, so I will fix them today.
Also , I found the data in PLANT_ETMX_STANDBY_IP_TEST_L_0001.xml was broken, so we cannot use it.
I'm not sure this problem due to my code or just failure of saving files due to other reasons, so I will again test it in this night.