[YamaT, Ushiba]
Abstract:
I tested the template files and automeasurement scripts for spectra and PLANT measurements.
Preparation of templates for spectra has been finished and they can be measured from the scripts.
Preparation of template for PLANT measurement is ongoing and now we can measure the mechanical transfer function of following DoFs from scripts:
IP{L,T,Y},BF{L,T,V,R,P,Y},{F0,F1,F2,F3,BF} GAS,MN{L,T,R,P,Y}.
Details:
We prepared template and automeasurement scripts for spectra measurements.
Measured data was stored at /kagra/Dropbox/Measurements/VIS/SPECTRA/{DIRNAME}/ with the name of SPE_{SUSNAME}_{STATE}_{SIGNALS}_{REFNUM}.xml.
{SUSNAME} is like ITMX, ETMX, and so on.
{STATE} is the guardian state when the measurement starts such as SAFE, ISOLATED, ALIGNED, and so on.
{SIGNALS} is classification of signals and currently I prepared IP, BF, GAS, PAYLOAD, and OPLEV.
{REFNUM} is a serial number of the measurement like 0001, 0002, and so on.
{DIRNAME} is a round down numbers of REFNUM like 0, 100, 200, and so on.
Also, we prepared template and automesurement scripts for TF measurement.
Measured data was stored at /kagra/Dropbox/Measurements/VIS/PLANT/{SUSNAME}/{DIRNUM}/ with the name of PLANT_{SUSNAME}_{STATE}_{STAGE}_{PORT}_{DOF}_{REFNUM}.xml.
{STAGE} is a stage we excite like IP, BF, F0, MN, and so on.
{PORT} is a excitation port like TEST and COILOUT.
{DOF} is a degrees of freedom we excite like L, T, V, ... or H1, H2, and so on.
I continue to run the script tonight and will report measurement results tomorrow.