Reports 1-1 of 1 Clear search Modify search
VIS (PR3)
fabian.arellano - 17:54 Thursday 07 October 2021 (18497) Print this report
Comment to In-vacuum cable health check at outer side of flanges. (18108)

With Hirata-san.

We fixed problems with BF Damper LVDT cables:

  • BF-H3,
    • Place: P2-3
    • Pins: 1,6
    • Symptom: the resistance was 21.6 Ohm, which is higher than expected.
    • Solution: We identified the problem was at the pins of the white extension cable connected directly to the LVDT.  When we moved it, the resistance changed by relatively large amounts. Hirata-san removed the problematic pins, put new ones and the resistance became stable with a value of 11.46 Ohm.
  • BF-V3
    • Place: P2-1
    • Pins: 1,6
    • Symptom: the resistance was 14.1 Ohm, which is slighly higher than the expected ~ 11 Ohm.
    • Solution: We identified a problem in a connector. When we moved it, the resistance changed by non-negligible amounts. Hirata-san removed the problematic pins and put new ones and the resistance became stable. However, its value remained at around 14.13 Ohm. This might not be a problem, but we will watch it in case glitches appear.
Search Help
×