VISのDAQチャンネルの整理 TOWER_MASTER, PAYLOAD_MASTERを変更しました。 変更したDAQチャンネルは次です。 [Tower] K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_LVDTINF_GAS_IN1 2048 -> 512 K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_LVDTINF_GAS_OUT 256 (New) K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_DAMP_GAS_IN1 2048 -> 1024 K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_DAMP_GAS_OUT 256 -> 256 K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_MASTER_OUT_GAS 512 (New) K1:VIS-{optic}_BF_DAMP_{L,T,Y,V,R,P,Y}_IN1* 2048 -> 1024 (Non Science Frame) K1:VIS-{optic}_BF_LVDTINF_{H1,H2,H3,V1,V2,V3}_IN1 512 (New) K1:VIS-{optic}_BF_LVDTINF_{H1,H2,H3,V1,V2,V3}_OUT 256 (New) K1:VIS-{optic}_BF_MASTER_OUT_{V1,V2,V3,H1,H2,H3} 512 (New) [Payload] K1:VIS-{optic}_IM_DRIVEALIGN_{L,P,Y}_OUT* 2048 -> 2048 (Non Science Frame) K1:VIS-{optic}_OSEMINF_{V1,V2,V3,H1,H2,H3}_IN1* 256 -> 1024 (Non Science Frame) K1:VIS-{optic}_OSEMINF_{V1,V2,V3,H1,H2,H3}_OUT 256 (New) K1:VIS-{optic}_OLDAMP_{L,P,Y}_IN1* 256 -> 1024 (Non Science Frame) K1:VIS-{optic}_OLDAMP_{L,P,Y}_OUT 256 (New) K1:VIS-{optic}_MASTERSWITCH_OUT_{V1,V2,V3,H1,H2,H3}* 2048 -> 2048 (None Science Frame) optic: Update: PRM Next Update: ETMX,ETMY,ITMX,ITMY,BS,SRM,SR2,SR3,PR2,PR3,MCI,MCE,MCO,IMMT1,IMMT2,OMMT1,OMMT2,OSTM k1visprmpnのインストール途中にK1PRM,K1LSC0,K1ASC0,K1SRMの復旧が必要になりました。 [問題点] k1visprmpを更新した際にモデルの再起動でハングした。 [復旧手順] 1.K1PRMの復旧作業を行いました。 K1PRMのDolphinをDisableしたあと、しばらくするとK1LSC0が道連れにFEのPCがハングしました。 K1PRMはWebInterfaceからrebootしました。 2.次にK1LSC0を復旧を合わせて行いました。 k1lsc0のDolphinをDisableを行う際にK1PRMの再起動途中であった為、DolphinのDisableプロセスがハングしました。 Yamamoto-sanがプロセスをkillして、K1PRMが起動後に再度実行すると正しくDiableできました。 この時点で、K1ALS0とK1SRMのDolphinの接続が切れました。 とりあえずK1LSC0をWebInterfaceから再起動を行いました。 再起動によりDolphinを認識しないケースがあり、2回ほどWebInterfaceから再起動しました。 3.次にK1ALS0にsshでログインしてコマンドから再起動(sudo shutdown -r now)しました。 しかし同様にDolphinを認識しないことがあり、再度WebInterfaceから再起動しました。 4.次にK1SRMにsshでログインしてコマンドから再起動しました。 こちらは1回で正常にDolphinを認識して、システム全体の復旧が完了しました。 停止していていた期間はおよそ10:45-12:15です。 --- Organizing DAQ channels for VIS TOWER_MASTER and PAYLOAD_MASTER have been changed. The DAQ channels that have been changed are [Tower]. K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_LVDTINF_GAS_IN1 2048 -> 512 K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_LVDTINF_GAS_OUT 256 (New) K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_DAMP_GAS_IN1 2048 -> 1024 K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_DAMP_GAS_OUT 256 -> 256 K1:VIS-{optic}_{F0,F1,F2,F3,SF,BF}_MASTER_OUT_GAS 512 (New) K1:VIS-{optic}_BF_DAMP_{L,T,Y,V,R,P,Y}_IN1* 2048 -> 1024 (Non Science Frame) K1:VIS-{optic}_BF_LVDTINF_{H1,H2,H3,V1,V2,V3}_IN1 512 (New) K1:VIS-{optic}_BF_LVDTINF_{H1,H2,H3,V1,V2,V3}_OUT 256 (New) K1:VIS-{optic}_BF_MASTER_OUT_{V1,V2,V3,H1,H2,H3} 512 (New) [Payload] K1:VIS-{optic}_IM_DRIVEALIGN_{L,P,Y}_OUT* 2048 -> 2048 (Non Science Frame) K1:VIS-{optic}_OSEMINF_{V1,V2,V3,H1,H2,H3}_IN1* 256 -> 1024 (Non Science Frame) K1:VIS-{optic}_OSEMINF_{V1,V2,V3,H1,H2,H3}_OUT 256 (New) K1:VIS-{optic}_OLDAMP_{L,P,Y}_IN1* 256 -> 1024 (Non Science Frame) K1:VIS-{optic}_OLDAMP_{L,P,Y}_OUT 256 (New) K1:VIS-{optic}_MASTERSWITCH_OUT_{V1,V2,V3,H1,H2,H3}* 2048 -> 2048 (None Science Frame) optic: Update: PRM Next Update: ETMX, ETMY, ITMX, ITMY, BS, SRM, SR2, SR3, PR2, PR3, MCI, MCE, MCO, IMMT1, IMMT2, OMMT1, OMMT2, OSTM During the installation of k1visprmpn, K1PRM, K1LSC0, K1ASC0, and K1SRM need to be restored. [Problems] When k1visprmp was updated, it hung at the restart of the model. [Recovery procedure]. 1. K1PRM recovery was performed. After disabling Dolphin in K1PRM, after a while, the FE PC hung with K1LSC0 in the way. I rebooted K1PRM from WebInterface. 2. Next, I tried to restore K1LSC0 as well. When I tried to disable Dolphin on k1lsc0, K1PRM was in the middle of rebooting and the Dolphin Disable process hung. When Yamamoto-san killed the process and ran it again after K1PRM started, it was able to disable Dolphin correctly. At this point, the Dolphin connection between K1ALS0 and K1SRM was broken. I restarted K1LSC0 from WebInterface. I had to restart K1LSC0 from the WebInterface twice because some of the reboots did not recognize Dolphin. 3. Next, I logged in to K1ALS0 via ssh and rebooted it via command (sudo shutdown -r now). However, Dolphin was not recognized in the same way, so I rebooted via WebInterface. 4. Next, I logged into K1SRM via ssh and rebooted via command. This time Dolphin was recognized successfully and the entire system was restored. The period when the system was down was approximately 10:45-12:15.