satoru.takano - 8:48 Wednesday 08 May 2024 (29416) Print this report
GR-IR coupling investigation

Ushiba, Tanaka, Takano

 

Abstract

We started to investigate the source of the strange coupling of ALS signal and IR REFL. We checked the slow DAQ of GrPDH of each arm with the shutter closed. We found that GrPDHX signal is noisier than GrPDHY above ~20 Hz, with many peaks and white noise floor,

and nonstationary peaks above 7 kHz were seen for both PDH signals.

 

Detail

For years we have suffered from the mysterious coupling between ALS signal and IR signal (ref: 11411). It might be due to a GND loop around REFL/POP/POS area and could be coupled to DARM sensitivity. To solve this issue once for all we started to investigate the source of this coupling.

 

First we suspected that some electronics for GrPDH might oscillate at some high frequency. To check the behaviour in high frequencies, we monitored the spectra of GrPDH slow DAQ, not at 16 kHz but at 64 kHz. Figure1 shows the spectra of GrPDHX and GrPDHY in terms of the input equivalent noise of the common mode servo. The spectra labelled noX are the measurements taken in different time and REF are the spectra with the input of the servo open electrically. It is certain that above 20 Hz the ADC noise is below the signal from the RFPD.

 

From these measurements we found these characteristics;

  • For GrPDHX the floor level is almost flat above 20 Hz, 6e-7 V/√Hz, whereas the floor level of GrPDHY has some weird frequency dependence. At 100 Hz GrPDHX is about two times larger than GrPDHY.
  • For GrPDHX many peaks are seen, at 60, 120, 180, 240, 300, 480 (power line), 68, 136, 234, 260 (mysterious) Hz.
  • For both spectra, many peaks are found above 7 kHz. The center frequency of these peaks also changes in time (measurement no2 was taken 5 min after no1 measurement).

Anyway, it seems that the condition of GrPDHX is worse than GrPDHY.

 

Next

We will check the spectra of the related electronics one by one in high frequencies. Especially, we are interested in

  • The original RF signal from RFPDs
  • The demodulated signal above 32 kHz to check whether RFPDs are oscilating or not
Images attached to this report
LAS (General)
shinji.miyoki - 20:30 Tuesday 07 May 2024 (29415) Print this report
Comment to PMC REFL BD replacenment (29405)

Tanaka, Miyoki, Uchiyama, Yuzu, Takase,

 

[Summary]

The stuck existed in the Adjuster BD.

[What we did]

After the STM2 cable cut and the STM1 cable fixing, we restarted the search for the stuck position in the water path in the BDs chiller path in the PSL room.

We replaced the Adjuster BD with 30W detectable power detector. Because the water tubes that are attached to the Adjuster BD were fixed on the ceiling metal mesh above around the center of the optical table, we scarcely could move the Adjuster BD just above the edge of the optical table.

At this position, we removed the yellow tube that directly went to the chiller return side above a water basket. We found there was almost no water in the yellow tube. When we injected air by using air duster can into this yellow tube, the return side had also slight water and air. In this sense, this yellow tube had no stuck.

After that, we checked the Adjuste BD itself. We injected air by using the air duster can to the water input where the transparent tube was connected (this tube came from the PMC BD), and checked whether the air could come out from the other side water input where the yellow tube was connected or not. Consequently, there was no airflow could path through the Adjuster BD even though I tried 3 times. After that, I retried the same air injection from the other side. The first trial failed to the air pass through. However, the second trial succeeded in letting the air pass through the BD with some dirty pieces as shown in the photo. After this first air conduction, all air injection trials have succeeded in passing through the BD. So we concluded that, at least this Adjuster BD had stuck.

After that, we injected air to the transparent tube that was connected to the PMC BD to check the airflow to the output side of the chiller through the shutter BD and several tubes. Then we obtained the expected airflow! So we concluded that there was no stuck in PMC BD and Shutter BD and their tubes.

Images attached to this comment
MIF (ASC)
hirose.chiaki - 19:54 Tuesday 07 May 2024 (29398) Print this report
Comment to Cabling for WFSf3 (29281)

After this klog I found to need one more input port, the all required number of ports for WFSf3 is 10 ports. 
I checked the IOO rack availability today and there were 10 ports available in the IOO0 rack and 1 port available in IOO1.

The following is a summary of the different information when compared to ADC/DAC channel assignment.

  • IOO0, ADC0, ch8-ch12: Cables unplugged. There is still a filter for Refcav monitor on the model. (FIG1, FIG2)
  • IOO0, ADC1, ch20-ch23: "MCL DMD I&Q" cable is plugged in. No corresponding signal was found in k1IOO0.
  • IOO1, ADC1, ch20-ch23: "MZM DC SERBO ADC" cable is plugged in. No corresponding signal was found in k1IOO0.

To reduce electrical noise at the ADC, I need to avoid cabling across the rack. Now I have the following as a plan for the ADC inputs for WFSf3.

  1. Plug the ADC into the 10 available input ports in the IOO0 rack.
    → In that case, we need to consider whether to clean up or leave the Refcav monitor filters that remain in the model. I cannot decide now if Refcav will be reinstalled in KAGRA in the future.
  2. Add a new ADC to the IOO1 rack to supplement the 8inputs. Also plug it into one empty input on IOO1. Also unplug one unused port on IOO1 and plug it in.
    →However, when cleaning up unused filters and unused signals in the ADC of the IOO1 rack, we need to confirm that we are not reading those signals in the Guardian. 
    The MZM, ISS, and ALS signals are coming to the ADC in the IOO1 rack. At the moment, there is a proposal to use the input port of the ADC used for MZM since MZM is unlikely to be used in the immediate future, and also a proposal to borrow the QPDB of ISS since it is not in use.

I discussed these issues with Yamamoto-san and Ikeda-san.
We have no idea if we will need MZM and Refcav in the future, so we think Plan 2 is appropriate.

Images attached to this comment
LAS (General)
shinji.miyoki - 18:43 Tuesday 07 May 2024 (29406) Print this report
Comment to PMC REFL BD replacenment (29405)

From around 14:00, Ushiba-kun tried to LSC lock of IMC and it suceeded. However, ASC did not work even though it seemed to work in the morning time. After several checks of IMMT1 trans and so on, he suspected the laser beam was hidden by something at somewhere. Finally, we found the aluminum foil between IFI and IMMT was shading the beam! The aluminum foils inside seemed to roll inside because of no fixing and its rolling seemed to shade the beam.

Ushiba-kun, Hitrata-san and I fixed this nasty aluminum foil coveres. After that the IMC lock with LSC and ASC was successfully done.

VAC (PR2)
takashi.uchiyama - 16:55 Tuesday 07 May 2024 (29413) Print this report
The top chamber of PR2 has been closed
2024/05/07

Kimura, mTakahashi, Sawada, Nakajima, Uchiyama

We closed the top chamber of PR2.

We found that a pushing bolt was left at the flange between the body and the top. The bolt could not be pull out.
We checked that The edge of the bolt reach the flange surface or not. It dose not reach.
So we left it.
LAS (General)
hirotaka.yuzurihara - 16:51 Tuesday 07 May 2024 (29414) Print this report
Comment to PMC REFL BD replacenment (29405)
Images attached to this comment
IOO (IFI)
takafumi.ushiba - 16:38 Tuesday 07 May 2024 (29410) Print this report
Comment to STM2 cable cut (29407)

Attached picture shows the current situation inside the IFI chamber.
STM2 pico cables are cut just below the heat-shurink tubes and tied at the STM2 pole with peek tie (red circle in the picture: sorry but cables themselves cannot be seen because they are on the behind of STM2 pole.).
STM1 pico cables are fixed on the optical table with aluminum clamp by M6 screw with vent hole (yellow circle in the picture).

Images attached to this comment
VAC (PR3)
takashi.uchiyama - 16:37 Tuesday 07 May 2024 (29412) Print this report
The top chamber of PR3 has been closed
2024/05/07

Kimura, mTakahashi, Sawada, Nakajima, Uchiyama

We closed the top chamber of PR3.
VAC (PRM)
takashi.uchiyama - 16:36 Tuesday 07 May 2024 (29411) Print this report
The top chamber of PRM has been closed
2024/05/07

Kimura, mTakahashi, Sawada, Nakajima, Uchiyama

We closed the top chamber of PRM.
VAC (General)
tatsuki.washimi - 16:21 Tuesday 07 May 2024 (29404) Print this report
4pi photos inside the IFI, IMM, PRM chambers (2024-05-07)
LAS (bKAGRA laser)
shinji.miyoki - 16:12 Tuesday 07 May 2024 (29392) Print this report
Comment to Laser down again (29388)

The tube connection information is https://klog.icrr.u-tokyo.ac.jp/osl/?r=22249.

Precisely speaking, Chiller output -> transparent tube -> Shutter BD -> yellow tube -> PMC REFL BD -> transparent tube -> Adjuster BD -> yellow tube -> Chiller return.

So, 

  • remove the transparent tube at adjuster BD, then check the water flow.
    • If OK, the adjuster BD and its downstream yellow tube have stuck.
    • If no flow, the stuck point is at upstream.
      • remove the yellow tube at PMC REFL BD
        • If OK, the PMC REFL BD and its downstream transparent tube have stuck.
        • If no, the stuck point is at upstream: Shutter BD and its upstream yellow/downstream transparent tube.

By the way, do you know why the water-cooling type beam dumper was selected? The air cooling type beam dumper for 50W and 150W is enough for our purpose.

LAS (General)
shinji.miyoki - 16:10 Tuesday 07 May 2024 (29405) Print this report
PMC REFL BD replacenment

[miyoki, tanaka, yuzu, takase]

We replaced the PMC REFL BD with the 50W detectable power meter. the PMC REFL BD was just reset at other place near the original position on the same optical table in the PSL room.

Adter that, Tanaka-kun set the FB laser power at 10W to investigated the lock of PMC and IMC. PMC and IMC was successfully locked, and ASC seemed to work because the IMC output increased after angaging.

At the same time, the cleaning in the water vessel of the original chiller was done.

Comments to this report:
hirotaka.yuzurihara - 16:51 Tuesday 07 May 2024 (29414) Print this report
Images attached to this comment
shinji.miyoki - 18:43 Tuesday 07 May 2024 (29406) Print this report

From around 14:00, Ushiba-kun tried to LSC lock of IMC and it suceeded. However, ASC did not work even though it seemed to work in the morning time. After several checks of IMMT1 trans and so on, he suspected the laser beam was hidden by something at somewhere. Finally, we found the aluminum foil between IFI and IMMT was shading the beam! The aluminum foils inside seemed to roll inside because of no fixing and its rolling seemed to shade the beam.

Ushiba-kun, Hitrata-san and I fixed this nasty aluminum foil coveres. After that the IMC lock with LSC and ASC was successfully done.

shinji.miyoki - 20:30 Tuesday 07 May 2024 (29415) Print this report

Tanaka, Miyoki, Uchiyama, Yuzu, Takase,

 

[Summary]

The stuck existed in the Adjuster BD.

[What we did]

After the STM2 cable cut and the STM1 cable fixing, we restarted the search for the stuck position in the water path in the BDs chiller path in the PSL room.

We replaced the Adjuster BD with 30W detectable power detector. Because the water tubes that are attached to the Adjuster BD were fixed on the ceiling metal mesh above around the center of the optical table, we scarcely could move the Adjuster BD just above the edge of the optical table.

At this position, we removed the yellow tube that directly went to the chiller return side above a water basket. We found there was almost no water in the yellow tube. When we injected air by using air duster can into this yellow tube, the return side had also slight water and air. In this sense, this yellow tube had no stuck.

After that, we checked the Adjuste BD itself. We injected air by using the air duster can to the water input where the transparent tube was connected (this tube came from the PMC BD), and checked whether the air could come out from the other side water input where the yellow tube was connected or not. Consequently, there was no airflow could path through the Adjuster BD even though I tried 3 times. After that, I retried the same air injection from the other side. The first trial failed to the air pass through. However, the second trial succeeded in letting the air pass through the BD with some dirty pieces as shown in the photo. After this first air conduction, all air injection trials have succeeded in passing through the BD. So we concluded that, at least this Adjuster BD had stuck.

After that, we injected air to the transparent tube that was connected to the PMC BD to check the airflow to the output side of the chiller through the shutter BD and several tubes. Then we obtained the expected airflow! So we concluded that there was no stuck in PMC BD and Shutter BD and their tubes.

Images attached to this comment
IOO (IFI)
shinji.miyoki - 16:06 Tuesday 07 May 2024 (29407) Print this report
STM2 cable cut

[Ushiba, Hirata, Tanaka, Miyoki]

After the recovery of the IMC LSC ASC control, ushiba-kun checked the infkuence of the cable touch for the STM2 on the IMMT1/2 trans and pop forward etc.

According to Ushiba-kun opinion, the alignment of the STM2 seemed to be sensitive to the weight load of the cables, not the trembling of the cables themselves. When he lifted up the cables, the STM2 alignment moved temporally, but came bacck to the original position even after stopping to lift up. This implies that we can keep these cables if we can properly fix them on the optical table of the pole. However, it seemed to be quite difficult to perform such thing without mialignment of the STM2 mirror. So we decided that we cut these cables below the pin connections.

While, not so remarkable influence of the cable touch on the STM1 was observed. This is maybe because the a part of cables were winding on the optical table and their weight seemed not to pull the STM1, then they fell to the bottom of the vacuum chamber. So we decided to fix the cables by aluminum clamps on the optical table with a kapton sheet for protection.

Comments to this report:
takafumi.ushiba - 16:38 Tuesday 07 May 2024 (29410) Print this report

Attached picture shows the current situation inside the IFI chamber.
STM2 pico cables are cut just below the heat-shurink tubes and tied at the STM2 pole with peek tie (red circle in the picture: sorry but cables themselves cannot be seen because they are on the behind of STM2 pole.).
STM1 pico cables are fixed on the optical table with aluminum clamp by M6 screw with vent hole (yellow circle in the picture).

Images attached to this comment
DetChar (General)
shoichi.oshino - 15:55 Tuesday 07 May 2024 (29408) Print this report
Add shindo plots on SummaryPage
As requested from Washimi-san, I added shindo plots on SummaryPage.
You can see from GIF tab --> shindo page.
VIS (PRM)
takaaki.yokozawa - 13:03 Tuesday 07 May 2024 (29402) Print this report
Visual check PRM oplev
[YokozaWashimi]

We performed the visual check of PRM oplev.
It seems healthy.
Images attached to this report
VIS (IMM)
takaaki.yokozawa - 13:02 Tuesday 07 May 2024 (29401) Print this report
Visual check IMMT2
[YokozaWashimi]

We performed the visual check of IMMT2 oplev.
It seems healthy.
Images attached to this report
VIS (IMM)
takaaki.yokozawa - 13:02 Tuesday 07 May 2024 (29400) Print this report
Visual check IMMT1 oplev
[YokozaWashimi]

We performed the visual check of IMMT1 oplev.
It seems healthy.
Images attached to this report
PEM (Center)
tatsuki.washimi - 19:14 Monday 06 May 2024 (29399) Print this report
Comment to IFI Sack hammering (29357)

I estimated the transfer function from the base plate vibration to the optical table vibration, by
TF(impact@base -> ACC@table) / TF(impact@base -> ACC@base)

I also did the same calculation for the Ground (z) ->Table case, but the results became over 1 for many frequencies. I need to investigate whether my analysis is correct or not...

Images attached to this comment
DGS (General)
takahiro.yamamoto - 19:34 Sunday 05 May 2024 (29397) Print this report
Comment to MEDM time machine is available (29302)
The time machine code was modified as follows.
1. '.*_OUTMON' defined by cdsFilt (filterbank) blocks show past values of '.*_OUTPUT'.
2. '.*_OUTMON' defined by cdsEpicsOutput blocks show their past values.
(This modification doesn't affect to MEDM showing current values.)

-----
A channel name as '.*_OUTMON is used by one of the output monitor of the filterbank which is NOT recorded by DAQ. So the original (LIGO's) code of the time machine ignores '.*_OUTMON' and shows them as a white square. Unfortunately, many MEDM screens use '.*_OUTMON' instead of '.*_OUTPUT' or '.*_OUT16' in the KAGRA case. And also, some models define channels named as '.*_OUTMON by cdsEpicsOutput blocks which are DAQ-ed channels. Because of such KAGRA's situation, the time machine hadn't been useful for the MEDM screens displaying such '.*_OUTMON' channels.

Possible solutions
'.*_OUTMON' defined by cdsFilt blocks can monitor the output of filter modules even when the OUT_SW of the filter bank is off, but such a function is likely to be used by only a few experts. So almost all '.*_OUTPUT' on current MEDM screens had better to replaced as '.*_OUTPUT'.

'.*_OUTMON' for cdsEpicsOutput may be better to be renamed other name because many tools regard '.*_OUTMON' as a non-DAQ-ed channel.

Because these better solutions seems to require large modifications of real-time models and MEDM screens and much longer time, I modified the treatment of '.*_OUTMON in the time machine code.
DGS (General)
shoichi.oshino - 16:50 Sunday 05 May 2024 (29396) Print this report
Comment to Preparation of DGS maintenance (29350)
I restarted backup process of opt directory on k1bck0.
VAC (General)
shoichi.oshino - 15:15 Sunday 05 May 2024 (29395) Print this report
Comment to deactivation of vacuum alerts for IX, EX, and EY (28517)
I activated VAC alert for IX and EX with the threshold of 1e-4 Pa.
DGS (General)
shoichi.oshino - 14:27 Sunday 05 May 2024 (29394) Print this report
Kernel update on k1detfs0
I updated the kernel on k1detfs0 to the latest version.
LAS (bKAGRA laser)
shinji.miyoki - 8:43 Sunday 05 May 2024 (29393) Print this report
Comment to Laser down again (29388)

We found small metal pieces in the water vessel of the chiller. These metal pieces might come from inside the beam dumper as remnants after making a water path by milling.

LAS (bKAGRA laser)
shinji.miyoki - 8:19 Sunday 05 May 2024 (29391) Print this report
Comment to Laser down again (29388)

[Tanaka, Yamamoto, Yuzurihara, (miyoki, uchiyama: remote)]

[Summary]

There seems to be a stuck in the water circulation path for the beam dumpers(BDs). So these beam dumpers were not cooled by water from the chiller. As a result, the temp at the beam dumper at the REFL increased, then the interlock was triggered by its thermometer.

[What we did]

Firstly, we checked the water chiller for the beam dumper. The water level was slightly lower (The top of the metal circulating tube inside the water vessel was slightly above the water level). The chiller itself was on, and the temp setting was 15C(OK). At this moment we did not check whether the water was circulated or not.

Secondly, we checked the interlock box near the entrance door of the PSL  room. We found the interlock was activated with a red LED light. Thirdly, we checked the sealing of the thermometer on the back of the beam dump. The contact of the thermometer seemed to be good.

Then we reset the interlock successfully. After that, we confirmed that the warning message in the FB control application has not vanished and the temp shows ~50C. Then we closed the application and restarted it. The warning has vanished. However, the temp showed ~3C and it became ~ 50C again after pushing the enable button in the application. So, we closed the application again, and made off/on procedure for the FB laser amp itself. After starting the application, the temp showed ~20C and we could keep this temp after enabling the FB laser.

We increased the current to obtain 10W output.

After that, we started the investigation again on the water chiller system for BDs. Tanaka-kun noticed that the air bubble in the water tube did not flow at all. Also he touched the REFL beam dumper and he sensed relatively hot. Then we suspected that there was no water flow in the chiller system. We tried on and off the chiller. Tanaka-kun noticed that the air bubble position shifted a little bit every on/off action and that the tube itself showed a little bit of trembling. However, we could not realize the smooth flow of the air bubble.  Then we checked whether there was returning water flow just before the chiller or not even if the chiller seemed to try to flow water (We sensed some vibration in the chiller itself after pushing the pumping enable button). Then we confirmed that no water returning.

Firstly, we suspected there was something wrong in the chiller itself. So we replaced the chiller with a new one. However, there was also no returning water from the path in the PSL room. To check the chiller itself, we replaced the tube for going from the chiller to the PSL room with a new one, and checked whether there was water output or not. Then we got water flow output. So we concluded that there seemed to be a stuck in the tube-path for BDs in the PSL room.

Because stuck search in the PSL room is a hard work, we gave up today's recovery work.

The FB laser amp was left to be stopped. The seed IR was on.

[to do]

To check the stuck in the tube path in the PSL room, we need to 

  • change from OBS mode to Working mode for the PSL room for the long activities.
  • remove all parts on the tube path including BDs not to spoil the PSL room with water
  • check the stuck point in each part.

If we want to recover the FB at 20W output temporally, we can put air cooling type power meters (50W max and 150W max that we have) instead of these water cooling type beam dumpers. In this case, the interlock system will be temporarily disabled.

 

 

DGS (General)
takahiro.yamamoto - 22:12 Friday 03 May 2024 (29390) Print this report
Digital system came back online
This is recovery work from the trouble on klog#29361.
Digital system finally came back online. Now awgtpman also works fine.

-----
When I copied the NFS region (/opt) in order to salvage files, some file permissions were probably copied incompletely. rsync -a by root copies both permissions and owner but rsync -a by controls copies only permissions. Errors on file permission seem to make some delays which causes time out on launching awgtpman.

Now the copied disk by root is mounted at /opt, the copied disk by controls is mounted at /mnt/backup_controls, and original (partially broken) disk is mounted at /mnt/original.
Latest safe.snap is salvaged on /opt. Yesterday's changes except SDF exist only in /mnt/backup_controls. After cheking all files in /mnt/backup_controls, it should be removed and one more backup disk copied by root must be created.