Reports 1-1 of 1 Clear search Modify search
VIS (OMM)
ryutaro.takahashi - 22:43 Wednesday 17 July 2019 (9555) Print this report
Confirmation of BB height

[Takahashi, Aso]

We confirmed the height of the breadboard (BB) in the OMMT/OMC chamber.

Measured distance between the floor level of OMMT chamber and the top of BB:

  • 1048.5mm (1048mm in design) in OMMT
  • 1059mm (1058mm in design) in OMC

The measured height was consistent with the design one within the measurement precision.

The floor level of OMC was heigher than the OMMT one by 3mm.

Comments to this report:
ryutaro.takahashi - 23:01 Wednesday 17 April 2024 (29262) Print this report

[Takahashi, Ikeda]

We confirmed the height of the breadboard (BB) in the OMC chamber. We measured the distance between the floor level of the OMC chamber and the top of BB with the laser leveler. The BB top was (135.5-80=55.5mm) higher than the 1000mm point from the floor. This height (1055.5mm) was consistent with the last confirmation (1058-3=1055mm).

Images attached to this comment
shinji.miyoki - 0:07 Thursday 18 April 2024 (29265) Print this report

Could you please tell us when is the last measurement? before the Noto earthquake?

ryutaro.takahashi - 8:36 Thursday 18 April 2024 (29270) Print this report

Please see the original report in 2019 (klog 9555).

Search Help
×

Warning

×