VAC (MCE)takashi.uchiyama - 16:39 Monday 25 March 2024 (28960)
Print this reportDia. 400 flange at the MCE trance port has been attached2024/03/25
Kimura, Sawada, Nakajima, mTakahashi, Uchiyama
We attached did. 400 flange at the MCE trance port. We aligned the flange using the laser leveler.
Images attached to this report
Comments to this report:
nobuhiro.kimura - 16:41 Wednesday 27 March 2024 (28988)
Print this report[Kimura, Sawada, Nakajima and mTakahashi] On 25 March, to eliminate a loose fastening bolt on the top flange of the MCE that was expected to cause a vacuum leak, the fastening bolt was loosened at one end and retightened by diagonal tightening. The tightening torque was 40 Nm, and the elastomer seal was reused.