Reports 1-1 of 1 Clear search Modify search
VAC (MCE)
takashi.uchiyama - 16:39 Monday 25 March 2024 (28960) Print this report
Dia. 400 flange at the MCE trance port has been attached
2024/03/25

Kimura, Sawada, Nakajima, mTakahashi, Uchiyama

We attached did. 400 flange at the MCE trance port.
We aligned the flange using the laser leveler.
Images attached to this report
Comments to this report:
nobuhiro.kimura - 16:41 Wednesday 27 March 2024 (28988) Print this report
[Kimura, Sawada, Nakajima and mTakahashi]
On 25 March, to eliminate a loose fastening bolt on the top flange of the MCE that was expected to cause a vacuum leak, the fastening bolt was loosened at one end and retightened by diagonal tightening.
The tightening torque was 40 Nm, and the elastomer seal was reused.
Search Help
×

Warning

×