nami.uchikata - 11:37 Tuesday 19 December 2023 (28010) Print this report
Omicron triggers at System B
I have produced Omicron triggers for the strain channel for the O4a period at System B.
They are available at
/home/detchar/triggers/K1/CAL_CS_PROC_DARM_STRAIN_DBL_DQ_OMICRON

There some failed segments that exceed the trigger rate 10000 Hz.
Even if I raise the threshold value, Omicron still fails for those segments.
The figures are examples of such segments, we see strange behaviors in Spectrogram and Q-transform (Pastavi).
Images attached to this report
Comments to this report:
nami.uchikata - 14:50 Thursday 25 April 2024 (29328) Print this report
It seems the failure is caused by glitches from the IPC error.
I have already made segments that excludes the IPC error segments from the science mode.
/home/detchar/Segments/K1-GRD_SCIENCE_MODE_NO_IPC_ERROR