Reports 1-1 of 1 Clear search Modify search
MIF (General)
masayuki.nakano - 18:59 Friday 17 May 2019 (8898) Print this report
Comment to IR arm finesse measurement (8891)

[Keiko, Takaaki, Stefan, Masayuki]

The ETMY started to be warmed up today. We did ring-down measurement again, and found that the finesse got increased even at 33 K. The estimated finesse is 120, corresponds to the mirror loss of 1.1 %. We did several measurement and all of the fittings shows consistent value.

The low finesse might be because of the contamination on the mirror...??

Images attached to this comment