fabian.arellano - 13:45 Tuesday 19 May 2020 (14401) Print this report
Comment to IP does not move towards the set point. (14381)

In case you don't see the picture attached please click here: entry 14401.

Further investigation about the origin of the event suggests the cause was not an earthquake. The description of the picture is as follows:

  • The SR2 event happened at 23:42 UTC on May 7th when there's no earthquake.
  • The seismometer in the BS area clearly shows a perturbation at 00:33 UTC on May 8th, but nothing at 23:42 UTC on the 7th.
  • The perturbation mesured by the seismometer affected the feedback in SR3 IP.
  • Such perturbtion was likely the earthquake which happened southeast of Honshu island. See this report.

There will be a report in the VIS General section about this event, please stay tuned.