MIF (General)takahiro.yamamoto - 4:05 Tuesday 19 November 2019 (11627)
Print this reportTurning ON dewhitening filter for ETMY[Nakano, Miyoki, Yokozawa, Yamada, Yamamoto]
We tried to turned ON the dewhitening filter for the TM stage of ETMY.
But there is no efficient improvement (See red and green curve on attachment 1).
After then we planned to turn ON the dewhitening filter also for the TM stage of BS because MICH noise becomes closing to the current DARM sensitivity (See red and magenta curve on attachment 2).
But anti-dewhitening filter was not turned ON on the COILOUTF filter bank.
In the case that the BIO cable connected with the coil driver, filter modules 1-3, 6-8 should be turned ON such as SRM. But on the BS model, they are not turned ON (See attachment 3).
According to lscpi command, 3 BIO cards are already installed on k1bs.
So we need to check the cable connection in the mine.