Weekly maintenance on Jun. 19, 2019
[Miyakawa, Oshino, Yamamoto]

[09:00]
We requested IMC_DOWN state.

[~09:30]
All DAC outputs on k1imc0 are disabled.

[10:00~]
Front-End for k1imc0 was replaced.
Models were rebuilt for arranging CPU number.

[10:40]
k1imc0 was comes back online.

[~11:00]
Type-B models were in SAFE mode (by Fabian)

[11:00~]
Front-End for k1sr3 was replaced.
Models were rebuilt for arranging CPU number.

[11:30~]
k1bs, k1srm, k1als0, k1ioo1 were rebooted for enabling Dolphin.

[12:00]
daqd was restarted.


NOTE:
We applied burt snapshot at 8:40 for all related models.
We noticed following things.
- SHMEM connection between k1vissrmt and k1vissrmp is wrong.
- RMF1 connection between k1asc and k1vistmsy is wrong.
These are the problem on model files. Please fixed them.