Reports 1-1 of 1 Clear search Modify search
VIS (General)
tomohiro.yamada - 17:42 Tuesday 04 June 2019 (9077) Print this report
Coil balancing
[Yamada]
Coil-force balancing was partially done.
- MN coil balancing for EX was done.
- IM coil balancing for EX H1-3 and EY H1-3 were done.
- TM coil balancing for EX, EY and IX were done.
 
 
EX
EY
IX
IY
MN
Done
Not Yet
Not Yet
Not Yet
IM
H1-3: Done
V1-3: Not Yet
H1-3: Done
V1-3: Not Yet
Not Yet
Not Yet
TM
Done
Done
Done
Not Yet
Note: I postponed to balance MN V2 due to geometrical position and sensors.
 
Balancing frequency:
MNY&P: 0.02 Hz
IMY: 5 Hz
TMY:5 Hz, TMP: 8.5 Hz
 
Comparison between before and after balancing will be reported later.
Balancing scheme is quite simple fortunately, however we need more time for remaining balancing.