strange behavior of PR3 optical lever

The optical lever of the PR3 showed strange behavior at 4/21 6:19:31 UTC.
The SUM fluctuation got larger suddenly, and the oplev control cannot engaged.

I attached the plot and spectra of the oplev signals. Blue curves are the current one and red curves are the ones of yesterday.

Images attached to this report
Comments to this report:
masayuki.nakano - 16:22 Sunday 21 April 2019 (8707) Print this report

Mmm, the signal came back. I guess the laser source for the oplev gets close to out of order.

Images attached to this comment
masayuki.nakano - 12:47 Monday 22 April 2019 (8712) Print this report

[GGG, Nakano]

We changed the laser module for the oplev of the PR3. Now the SUM signal is about 10000.

Images attached to this comment