Reports 1-1 of 1 Clear search Modify search
VIS (IX)
lucia.trozzo - 16:19 Saturday 06 April 2019 (8564) Print this report
ITMX healthy check after pump down

The pump down of ITMX is finish on  April 4th and I started to check the transfer functionsof the tower part.

I measured the following transfer functions:

  • IP: L (pic1), T (pic2), Y (pic3)
  • BF: L (pic4), T (pic5), Y (pic6)
  • GAS filters: F1 (pic7), F2 (pic8), F3 (pic9), BF (pic10).

All stages looks to be healthy: now all damping controls are turned on.

Images attached to this report
Comments to this report:
kouseki.miyo - 13:25 Friday 02 July 2021 (17366) Print this report

BF is here.

Images attached to this comment