Temperature of the high power beam dump during HP IMC

The attahed files are the temperature of the high power beam dump at the PRM reflection.

The data logger started ~20mins after the IMC was locked with 22W input. The highest temperature was 45.5 deg C. The long term data is with the IMC with 3W input during the weekends. The IMC was unlocked at ~7am today and the temperature went down to the room temperature at that time.

I haven't connected this channel to the ADC yet.

Images attached to this report
Comments to this report:
kiwamu.izumi - 12:19 Tuesday 02 April 2019 (8542) Print this report

This seems like a good calorimeter. Good work.

masayuki.nakano - 15:39 Tuesday 02 April 2019 (8543) Print this report
Hi Kokeyama-san, Can you estimate the reaching temperature with the 20 W output from the IMC?