DGS (General)takahiro.yamamoto - 17:11 Wednesday 12 December 2018 (7347)
Print this reportKernel panic related with the BAD DAC on K1EY1 (not recovered yet...)[Fujii, Yamamoto]
We found the BAD DAC problem (DAC BCR = 0xffffff) on K1EY1.
So kernel panic occurred repeatedly.
After Fujii-kun removed the 1st DAC from the IO chassis, the real-time models can start.
(k1visetmy now runs with only 2 DACs.)
I will recover it tomorrow afternoon.
Comments to this report:
takahiro.yamamoto - 21:30 Thursday 13 December 2018 (7371)
Print this reportI cleaned up the PCIe terminal of the DAC card and reinstalled it in the K1EY1.
K1EY1 comes back online now and k1visetmy is running.