Reports 1-1 of 1 Clear search Modify search
IOO (General)
naoki.aritomi - 16:58 Friday 30 November 2018 (7209) Print this report
Circuit for beam shutter solenoid driver worked
 
[Aritomi, Michimura]
 
We made circuits for beam shutter solenoid driver. 
The conceptual design is as follows.
https://gwdoc.icrr.u-tokyo.ac.jp/cgi-bin/private/DocDB/ShowDocument?docid=9262
 
They worked fine. In an attached movie, we are switching DAC 5V trigger.
Note that about 300 mA current is necessary to drive the solenoid.
 
We made circuits for beam shutter solenoid driver.
The conceptual design is as follows.
We made circuits for beam shutter solenoid driver.
The conceptual design is as follows.
Images attached to this report
Non-image files attached to this report
Comments to this report:
keiko.kokeyama - 22:34 Friday 30 November 2018 (7223) Print this report
Awesome video!!!!! Thank you so much