LOG-IN
Displaying report 1-1 of 1.
IOO (General)
Print this report.
masayuki.nakano - 00:43, Friday 16 November 2018 (7010)Get code to link to this report
FSS and IMC UGF adjustment

The UGSs of the FSS and the IMC loop were adjusted. Adjusted UGFs and the phase margins are as below;

 FSS: 83 kHz, 34 deg
 IMC: 22 kHz, 45 deg

The OLGs are attached. Actually, the UGF of the FSS is not high enough...frown But, for the XARM commissioning, it would be fine.

Images attached to this report
7010_20181115164249_olg.png 7010_20181115164305_olg.png