Prometheus (green laser) was phase locked to the main laser!

[Enomoto, Midooka, Yokogawa]

We did phase lock a Prometheus to the main laser!!coolThe attached figure is the beatnote signal during control.

What we did;

  • put jumper pins in the Dsub-BNC Converter (DAC) chassis in order to ground the outside of BNC.
  • created filter bank so that the temperature of a Prometheus can be varied by offset.
  • Yesterday, the peak of the beatnote was -18 dBm, but it had dropped to about -30 dBm today. So, we raised the power of Prometheus side from about 3mW to 15mW so that the peak of the beatnote is -11dBm. (The phase frequency discriminator (PFD) requires a beatnote signal with a peak of -11dBm)
  • locked the beatnote at 40MHz. (This means the frequency of Prometheus was locked at 40MHz away from the main laser.)

Next;

  • We will measure OLTF.