Reports 1-1 of 1 Clear search Modify search
CRY (Cryostat IX)
takafumi.ushiba - 11:10 Friday 03 August 2018 (5698) Print this report
Installation of the TM oplev viewports on IXC

[Yamada, Takahashi, Ushiba]

We finished installing the AR viewports on the IXC.
The torques are as follows:
5 Nm -> 10 Nm -> (one-day wait) -> 10 Nm

I put tapes near flanges, so you can find this information near flanges as well.
We have one more viewport for MN OpLev to install.
So, we will do it after closing the large flanges of IXC.

Comments to this report:
takafumi.ushiba - 15:38 Friday 03 August 2018 (5704) Print this report

We found that nominal torque for ICF152 flange is 15Nm.
So, we retighten them as follows:
15Nm -> 15Nm (so, total is 5Nm -> 10Nm -> 10Nm ->15 Nm -> 15Nm)

We also wrote serial numbers of the viewports on wiki page.