Reports 1-1 of 1 Clear search Modify search
VIS (SR3)
yoshinori.fujii - 19:51 Tuesday 24 July 2018 (5598) Print this report
setting for SR3-OpLev

Akutsu-san, Kozu-kun, Eleonora, Fujii

We installed the following 2 stages and 2 viewports for OpLev system of SR3 suspension:
-VQ4717_Oplev TX * #1, with M8*20 * #6
-VQ4935_Oplev RX * #1, with M12*(long..) * #4     
-viewport for technoport oplev (ICF152) * #2, ID: sn-19/sn-20

I note that: 
-The screws to lock the VQ4935_Oplev RX might have to have washers.
-Now one PQD stage for an angular OpLev and its clamp are placed at a SR3-booth table (outside).
What is missing is to be confirmed soon.

Images attached to this report
Comments to this report:
tomotada.akutsu - 7:16 Wednesday 25 July 2018 (5601) Print this report

About the SR-oplev

Again in the SR-oplev, as the case of the BS's one, the optical beam should be launched in the vertical direction with some launching tilts; what a f**cking design, you will be in a nightmare of the mixture of DoFs soon.

About the SR-oplev TX stand

  1. As shown in the drawings I've sent to Fujii-kun (later I'd like to upload to jgwdoc), and as I said, please put the usual black breadboard (from Narahara) on the stand top. Be noted that the contact surfaces of the both sides (the top surface of the stand top and the bottom surface of the breadboard) do not have dust... please wipe them.
  2. Using three stud bolts under the stand top, you can tune the horizontalness of the located breadboard on it. Please use some bubble levels to check the horizontalness.

Abour the SR-oplev RX island

As the same case as in the TX stand, please put the Narahara breadboard on it.

 

About the GigE Camera

Please ask Kokeyama-san to attach the camera stage for ICF152 viewport in the opposite side of the oplev setup.